MAURY USCG vessel records
← All vessels

GEORGE WATSON

Built
1996
Last inspected
4 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 May 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9112727
443610
Flag
UNITED STATES
Maury page id
psix-443610

Documentation record

Registered dimensions (L × B × D)911.7 ft × 105.8 ft × 89.1 ft
Registered tonnagegross 72,718 / net 21,815
ITC dimensions (L × B × D)911.7 ft × 105.8 ft × 89.1 ft
ITC tonnagegross 72,718 / net 21,815
BuilderGENERAL DYNAMICS, NATIONAL STEEL AND SHIPBUILDING COMPANY · SAN DIEGO, CA, UNITED STATES · built 1996
Hull materialSteel
PropulsionGas Turbine
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72718 - Convention (Subpart B), Gross Ton
21815 - Convention (Subpart B), Net Ton
26287 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 62 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SSG EDWARD A CARTER JR Freight Ship · MISLE 34118 · 16 January 2025 · activity 8101444CORNHUSKER STATE Freight Ship · MISLE 46269 · 16 January 2025 · activity 8101444SCOTT TURECAMO Towing Vessel · MISLE 476323 · 16 January 2025 · activity 8101444

Inspection history · 62

4 May 2026 Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8358174
23 January 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8300590
12 November 2025 MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8262531
19 August 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8210636
2 August 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8236681
10 July 2025 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8182444
5 February 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8104214
21 January 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8067073
16 January 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8101444
10 January 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8060832
30 December 2024 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8052994
4 December 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042950
2 October 2024 Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8012902
12 April 2024 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7893973
24 December 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7842398
15 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7791928
31 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7801504
27 August 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7895580
6 July 2023 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7734380
6 April 2023 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7663656
5 April 2023 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7675764
22 October 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7584263
30 August 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7547948
21 April 2022 ACP COI Oversight · Re-Inspection · ACP Drydock Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7435255
21 April 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7436022
19 October 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7335663
18 August 2021 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7293936
29 July 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7271308
8 March 2021 ACP Periodic Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7169300
3 November 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7088659
22 February 2020 Annual Inspection · ACP Annual Oversight · Ballast Water Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6883115
20 November 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6858889
23 October 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6840817
2 October 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6826010
29 July 2019 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6765635
18 March 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6644161
7 March 2019 Ballast Water Examination · MTSA Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6629376
6 March 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6637061
6 March 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7018287
13 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6579941
13 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6583204
13 November 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6584103
8 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6577925
5 November 2018 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6574502
2 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6573140
28 October 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6570038
15 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6563061
3 October 2018 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6554315
25 September 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6548671
12 September 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6539101
13 June 2018 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6443521
8 May 2018 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6409962
7 May 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6423296
1 February 2018 ACP COI Oversight · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6352486
6 December 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6319634
8 June 2017 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6338371
9 May 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6142000
28 March 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6132634
16 December 2016 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6137443
28 June 2016 Deficiency Check · Drydock Exam · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5955976
10 February 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5813291
27 January 2016 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5798101

Deficiency record · 23

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 October 2024 Resolved
All life saving appliances and arrangements shall comply with the applicable requirements of the Code. The launching mechanism shall be arranged that it may be actuated by one person from a position on the ship's deck and from a position within the survival craft. The launching mechanism to be actuated by a person inside of the survival craft was found uninstalled and laying outside of the #1 lifeboat. The crew re-installed it into the lifeboat prior to the completion of the inspection. SOLAS 74 (2004 cons.) Reg 34 LSA Code Ch VI 6.1.2.2
Action required: 10 - Deficiency Rectified
Due 11 October 2024
Resolved 11 October 2024
Resolution: The crew re-installed it into the lifeboat prior to the completion of the inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 10 October 2024 Resolved
The company and the ship shall comply with the requirements of the ISM Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. The various tasks should be assigned defined and assigned by qualified personnel. MI observed a fire detector isolated on the fire detection system bridge panel. The following was identified through additonal discussions with the crew members: the company has not not established written procedures or checklists using the onboard safety management system for when fire detectors are isolated from the detection system and the crew or contractors are performing maintenance onboard. The crew will verbally pass any fire detection isolation to the bridge watchstander and use an unofficial green logbook, however, there is no written procedure for this. The onboard unofficial verbal procedures for isolating the fire detection system fail to include: notification to the master when isolating single or multiple detectors from the fire detection panel, notifying the master whent the isolation is complete, establishing a fire watch/additional fire fighting precautions for the space/section when the system is isolated. SOLAS 74 (2020 cons.) Ch IX Reg 3.1 ISM Code Part A, 7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2024
Resolved 17 October 2024
Resolution: Received ABS report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 10 October 2024 Resolved
The company and the ship shall comply with the requirements of the ISM Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish and maintain procedures to control all documents and data which are relevant to the safety management system. The company should ensure that valid documents are available at all relevant locations, changes to documents are reviewed and approved by authorized personnel, and obsolete documents are promptly removed. The onboard safety management system referred as SQMS requires the crew to use the program "Watchkeeper v 3.51" in order to log STCW work/rest hours. The controlled document in the SQMS that refers to this program is MAN-056-Compliance. MI requested to review the Watchkeeper program and identified that the license expired. The crew are unable to use this program as per the SQMS and document MAN-056-Compliance is still valid or has not been revised in the SQMS. SOLAS 74 (2020 cons.) Ch IX Reg 3.1 ISM Code Part A 11.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 17 October 2024
Resolution: Received ABS Report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 October 2024 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of cargo ships, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and 9.6. The following Class A fire doors were found with hold backs: galley doors 01-107-3, fwd paint locker door 2-10-2, stairwell door located at frame 85 3-20-0, and the compacted trash storeroom door. The door between the scullery and galley was found with a fan electrical cord installed in between the two spaces which prevents the door from closing. SOLAS 74 (2004 cons.) Ch. II-2 Reg 9.2.3.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2024
Resolved 17 October 2024
Resolution: Received ABS report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 10 October 2024 Resolved
Ventilator openings shall be provided with weather tight closing appliances. The ventilator located on the A deck at frame 18 was found heavily corroded and mis-alligned with the gasket, preventing it from closing or dogging down. The ventilator is marked as 1-18-1. ICLL 1966 Ch. 1 Reg 19.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2024
Resolved 17 October 2024
Resolution: Received ABS report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 October 2024 Resolved
Each power-operated sliding watertight door shall be provided with an individual hand-operated mechanism. It shall be possible to open and close the door by hand at the door itself from both sides. The handle for the WTD manual operation, fwd of the door, located at 5-86-2 was missing during the inspection. The crew constructed a new handle after the inspector departed the vessel. The manual operation of the WTD using the new handle was not witnessed by the [name withheld] 74 (2004 cons.) Ch II-1 Reg 25-9.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2024
Resolved 17 October 2024
Resolution: Received ABS report.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 October 2024 Resolved
Fire-fighter's outfits shall comply with the Fire Safety Systems Code. A firefighter’s outfit (ensembles) shall consist of axe with a handle provided with high-voltage insulation. In accordance with MSC/USCG MOA dated 22AUG2024, Annex III – Modification of Standards, 5.c, vessel was unable to produce two or four axes per fireman’s ensembles. SOLAS 74 (2004 cons.) Ch. II-2 Reg 10.1 FSS Code 3.2.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 17 October 2024
Resolution: ABS report received.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 2 October 2024 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. A crew member used a damage control hose for fire fighting during the fire drill. The damage contorl hose has a different thread than the fire hoses and nozzles. The crew member was unable to thread a fire nozzle on the damage control hose and after several minutes, a different crew member brought another fire hose to replace the damage control hose. The crew member was provided additional training by the officers onboard after the drill was completed. SOLAS 74 (2004 cons.) Ch. II-2 Reg 15.2.2.1
Action required: 10 - Deficiency Rectified
Due 11 October 2024
Resolved 11 October 2024
Resolution: The crew member was provided additional training by the officers onboard after the drill was completed.
09 - Working and Living Conditions › 091 - Living Conditions › Provisions quality
Issued 2 October 2024 Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should ensure that the policy is implemented and maintained at all levels of the organization both ship based as well as shore based. Numerous food stores on board were found to be passed their labeled expiry date with no documentation provided either extending their lifecycle or deeming them unfit for human consumption per NAVSUP P-486, Vol I, Rev 9 Food Service Management. SOLAS 74 (2020 cons.) Ch IX Reg 3.1 ISM (2018) Part A/2.2; MSC – USCG MOA 2024 – Annex III/5 (MSC-ACP)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2024
Resolved 17 October 2024
Resolution: Received ABS report.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 6 April 2023 Resolved
Vessel reported a hole in the bottom of the centerline oily water holding tank. The hole has been plugged with a 2" plug. Vessel is to conduct permanent repairs IAW ABS requirements.
Action required: 705 - Other - as specified
Due 14 April 2023
Resolved 15 April 2023
Resolution: ABS attended and issued work order 5780956
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 August 2022 Resolved
The condition of the ship shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Numerous numbers of the overboard swing check scuppers on the RO/RO decks above the bulkhead decks are stuck in place and are not able to swing. Prior to carrying cargo ensure that the overboard swing check scuppers are all operating freely.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 9 August 2022 Resolved
A training manual shall be provided in each recreation room or in each crew cabin there is no SOLAS Training Manual in “Supercargo Pers Lounge” 01-124-2 provide a SOLAS Training Manual.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 August 2022 Resolved
Fire-fighting systems shall be readily available for immediate use. Fire station FM V-52/FM CO V 2-85-2 is blocked by racks of steel. Clear an access to the fire station and make ready for immediate use.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 August 2022
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 August 2022 Resolved
The in-line proportioners (aerator) still have duct tape around the screens on B-Deck as fire-fighting systems shall be readily available for immediate use, remove all the tape.
Action required: 10 - Deficiency Rectified
Resolved 9 August 2022
Resolution: Tape removed while onboard
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner, the starboard emergency light by fire station #18 has a damage junction box. Make proper repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2022 Resolved
The deck light above vent opening by location 1-45-4 has a mounting that is broken make proper repairs so the so installation will not to cause injury when handled or touched in the normal manner.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: #5391834 OSR 1358
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 7 March 2019 Resolved
Make proper notifications to RO reguarding OCM casulty for the machinery OCM.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 29 March 2019
Resolution: Received confirmation from the vessels Master that the OCM was calibrated and a certificate of calibrarion was issued on 29MAR19 by Tyrner Desighs, NAG Marine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 March 2019 Resolved
Replace grab line for life buoys with approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2019
Resolved 20 March 2019
Resolution: Recieved confirmation from ABS surveyor that all grab lines were replaced with the apporved type.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 7 March 2019 Resolved
Properly document all required entries on vessels confined space entry forms in accordance with the vessels SMS.
Action required: 10 - Deficiency Rectified
Due 7 March 2019
Resolved 7 March 2019
Resolution: The vessels Chief Mate made all corrections and will provide training to the crew on proper entries being logged. A corrective action report will be submitted to the company.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 8 May 2018 Resolved
Prove proper operation of anchor windlasses #3 and #4.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2018
Resolved 10 May 2018
Resolution: Rec'd tech reports and class report.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 8 May 2018 Resolved
Prove proper operation of port CPP
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2018
Resolved 10 May 2018
Resolution: Rec'd tech report and prelim class report.
Engineering › Shafting/Propeller Arrangements › Thrust Shaft
Issued 16 December 2016 Resolved
Vessel is operating with reduced propulsion (one siezed shaft) and is required to have the assistance of two tugs while transiting inside the Sector Hampton Roads Regulated Navigation Area (RNA). One tug must be of 3000 horsepower or more; & the other must be of 2000 horsepower or more. Cite: 33 CFR 160.111(c)
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 31 January 2018
Resolution: Vessel completed dry dock and shaft repair under ABS supervision. ABS conducted sea trials from 02-05 Feb 18 with no deficiencies.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 February 2016 Resolved
The vessels crew was unable to properly operate the OWS. Prove proper operation of OWS to the satisfaction of Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 10 February 2016
Resolution: Witnessed operational test, all sat

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.