Records from 1988 to 2026. Most recent: inspection, 7 May 2026.
Inspection history · 113
7 May 2026
Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8368093
10 December 2025
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8281742
22 October 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8256524
23 June 2025
Appeal
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 8165067
6 May 2025
Appeal
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8133083
19 March 2025
Deficiency Check · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8092423
5 March 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8088755
16 January 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8101444
15 October 2024
Type not recorded
No type recorded · Activities Europe · Activity 8022045
23 August 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7987448
12 July 2024
ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7954217
11 July 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7972521
11 July 2024
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8004713
9 May 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8006247
27 August 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7780064
3 March 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7647716
6 February 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7634967
8 November 2022
MTSA/ISPS Verification · ACP COI Oversight · COI Inspection · ACP Drydock Oversight · Re-Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7591885
2 November 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7587258
8 February 2022
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7386691
27 August 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7296565
23 February 2021
ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7142991
23 February 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7146371
20 January 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7127804
17 September 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7060307
17 January 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6891598
9 January 2020
Annual Inspection · ACP Annual Oversight · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6884239
6 January 2020
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6883196
20 September 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6815984
19 September 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6816019
21 August 2019
ISM SMC Audit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6790786
30 January 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6616270
20 November 2017
Administrative Inspection · COI Inspection · Special · ACP Drydock Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6301422
11 September 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6264063
20 July 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6229890
19 December 2016
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6061810
8 February 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5811520
16 December 2015
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5786911
2 December 2015
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5770236
8 February 2012
ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4243519
2 February 2011
ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3943605
16 March 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3702970
19 January 2010
ACP Periodic Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3665804
12 February 2009
ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3416813
6 December 2007
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3110725
26 October 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3087677
23 February 2007
ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2876585
23 February 2006
ACP Annual Oversight · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2592575
20 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2363067
17 May 2005
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2362105
18 January 2005
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2276514
7 January 2005
ACP Annual Oversight · MTSA Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2272516
6 January 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2278646
3 June 2004
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2087468
12 March 2004
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2023360
12 February 2004
Annual Inspection · ACP COI Oversight
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2003232
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996188
30 October 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1939279
24 January 2003
ACP COI Oversight
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1734909
27 November 2002
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1711571
26 February 2002
In-Service Inspection · Damage Survey · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1492956
5 November 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1076108
6 June 2001
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1076856
22 September 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1054302
3 May 2000
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1412104
1 March 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 93358
14 February 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 817395
22 October 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 791593
4 October 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1198004
14 July 1999
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1395235
24 February 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 136830
3 February 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 791123
10 September 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 800239
5 May 1998
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1450154
6 October 1997
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1398756
25 June 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 777374
12 May 1997
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1400571
25 November 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 869480
10 October 1996
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 841867
22 July 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1087002
16 May 1996
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1448760
7 January 1995
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1449743
30 October 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 87394
12 October 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 216993
16 September 1994
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 870377
5 May 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 858297
2 May 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 859050
1 May 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 130229
26 April 1994
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1358381
7 April 1993
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1145525
13 July 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1249331
19 June 1992
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 944383
15 April 1992
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 467708
15 April 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1267235
11 April 1992
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 953454
22 January 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943690
10 November 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 941105
3 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243720
19 September 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247581
5 September 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940828
5 August 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247019
18 June 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308099
11 June 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1328216
27 May 1991
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944049
29 April 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 40816
3 April 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926651
25 February 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1238214
13 February 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1216984
5 September 1990
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 899962
5 September 1990
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1236035
19 April 1990
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1213783
15 July 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 892105
12 April 1988
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1326599
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 22 October 2025
Resolved
All equipment to which this chapter applies shall be of a type approved by the Administration. Equipment for which the source of energy is intended to be user-replaceable should be provided with a dedicated primary battery for use in the event of a distress situation. This battery should be equipped with a non-replaceable seal to indicate that it has not been used. The three portable two-way VHF radio backup batteries were found without a seal on the package or battery.
74 SOLAS(24) IV/14.5
MSC.515(105)/12.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2025
Resolution: Received RO preliminary report.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2025
Resolved
A power-driven vessel underway shall exhibit: A second masthead light abaft of and higher than the forward one. Vessel's second masthead light redundant filament was inoperable and signaling a broken circuit on the navigational light panel on bridge.
33 CFR 83.23(a)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Multiple portable fire extinguisher brackets throughout the vessel were found to be of the wrong type for the installed extinguishers.
74 SOLAS (24) II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 October 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Bridge wing life buoys did not have the manufacturer recommended 13-foot lanyard for smoke float on port and stbd side.
74 SOLAS (24) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 22 October 2025
Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall: illustrate the purpose of controls and the procedures for operating the appliance and give relevant instructions or warnings. Port bridge wing life raft operating instruction placard is illegible.
74 SOLAS(24) III/9.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a pinhole leak for the saltwater feedline valve.
74 SOLAS (24) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 October 2025
Resolved
The following fire protection systems shall be kept in good order so as to be ensure their required performance if a fire occurs: fire detection and fire alarm systems. Heat Detector in the ECR is melted.
74 SOLAS (24) II-2/14.2.1.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 October 2025
Resolved
Fire-Fighting systems and appliances shall be kept in good working order and readily available for immediate use. Failed valve in Fire Station No. 30 caused water to flow into stored fire hose when fire main was charged.
74 SOLAS (24) II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Water, pipes, tanks
Issued 22 October 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Potable water hydro tank had a hole from wastage and soft patch applied.
74 SOLAS (24) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 22 October 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Lagging was slid down and not properly installed on main steam line flange on port boiler.
74 SOLAS (24) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Received RO preliminary report.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 October 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Starboard life boat brake release cable was damaged and not installed properly. Corrected on the spot.
74 SOLAS (24) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 3 May 2026
Resolution: Release cable fed back into lifeboat properly. Verified correction. See MISLE.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 March 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The primary CO2 system for the cargo holds and engine room had 20+ high pressure bottles with loose flex hose fittings. 74 SOLAS (20) II-2/14.2.1.2; 17a
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2025
Resolved 27 March 2025
Resolution: Accept by RO.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 March 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The CO2 system for the aft paint locker had one of the three high pressure bottles with a loose hose fitting.74 SOLAS(20) II-2/14.2.1.2; 17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 March 2025
Resolved
A vessel engaged in commercial service that does not carry passengers, shall record in a logbook information on all access and use of the vessel’s master key control system, including dates and times of access; the room or location accessed; and the name and rank of the crew member that used the master key. There were missing records between crew changes and a crew member needed master key access to their own room, but there was no record of the incident. 49 U.S.C. 3106(a)(3); 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 27 March 2025
Resolution: Missing records were located on board and reviewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 March 2025
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. The portside lifeboat safety harness (seat belt) at the operating station is broken. 74 SOLAS (20) III/20.2, 16/a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 19 March 2025
Resolved
For ships constructed before 1 July 2004, the Continuous Synopsis Record shall, at least, provide the history of the ship as from 1 July 2004. Continuous Synopsis Record number seven is missing and could not be located while on board. 74 SOLAS (20) IX-1/5.2.2; 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 27 March 2025
Resolution: Provided copy of CSR #7 to OIC and CM.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 19 March 2025
Resolved
The certificates and records of equipment shall be drawn up in the form corresponding to the models given in the appendix to the annex to the present Convention. The record of equipment for Safety [name withheld] states the life rafts accommodate 73 persons, however the current compliment accommodates 74 persons. 74 SOLAS (20) I/15; 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 March 2025
Resolved
The following tests and inspections shall be carried out weekly and a report of the inspection shall be entered in the log-book: all engines in lifeboats shall be run for a total period of not less than 3 min. During this period of time, it should be demonstrated that the gear box and gear box train are engaging satisfactorily. The lifeboat manufacturer manual states not to engage the propeller when out of the water, contradicting the required weekly engine and gearbox tests. 74 SOLAS (20) III/20.6.2; 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 8 May 2025
Resolution: Accept by RO. Vessel received updated instruction from mfg. Verified w/ surveyor that lifeboats can be ran per 74 SOLAS (20') III/20.6 for 3 min. w/ engaging prop w/ no issues.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 March 2025
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. The starboard side lifeboat has a leak coming through a cable penetration above the control station. 74 SOLAS (20) III/20.2; 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 March 2025
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. The portside lifeboat has a crack in the fiberglass in the fwd upper corner of the interior portside access hatch. 74 SOLAS (20) III/20.2; 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Two portholes in FWD house on STBD side has a temp repair consisting of a nonwatertight wooden insert in the Radio Operator and Master’s office windows running portable A/C exhaust and an electrical extension cord between decks. 74 SOLAS (20) I/11(a); 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 15 April 2025
Resolution: Accepted by ABS, rectification was returning the portholes back to original construction.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The FWD house on the portside main deck has a supply vent closure (2-36-2) with ceased hinges and dogs. 74 SOLAS (20) I/11(a); 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 15 April 2025
Resolution: Accepted by ABS. Supply vent closure (2-36-2) with seized hinges and dogs were freed and vent was confirmed to fully close and secure to the satisfaction of the attending surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 March 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The AFFF canisters in the SSDG space are from 1993 and no records are available to attest to the shelf life of the fire-fighting agent. Additionally, one of the canisters is cracked. 74 SOLAS (20) II-2 /14.1.1; 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The critical gauges above the console in main control are out of their calibration dates. 74 SOLAS (20 ) I/11(a); 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The aft bulkhead in the FWD pump room is heavily deteriorated in multiple areas and showing signs of potential holes. 74 SOLAS (20) I/11(a); 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The CGMI observed six disconnected reach rods to the ballast system in the FWD pump room rendering them inoperable. 74 SOLAS (20) I/11(a); 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 19 March 2025
Resolved
Each operation of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed. Oil record entries from July 2024 to present day are inaccurate due to entries not fully being recorded. For the movement of oily water, the code 15 is used, but not the corresponding action associated with code 15. MARPOL 73/78 (22) I/17.4; 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 27 March 2025
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 March 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The port side fiddley access door self-closing device is inoperable. 74 SOLAS (20) II-2/14.1.1; 10c
Action required: 10 - Deficiency Rectified
Due 19 March 2025
Resolved 19 March 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2025
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for its COI annual inspection.
46CFR91.27-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2025
Resolution: Vessel completed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 July 2024
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency fire pump could not supply water. 74 SOLAS (20)II-2/14.2.1.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 12 July 2024
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Portable fire extinguishers in the STBD lifeboat were not serviced. 74 SOLAS (20) III/20.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 July 2024
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Life rafts were not on board. 74 SOLAS (20) III/20.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 July 2024
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Line throwing appliances were not assembled with rockets. 74 SOLAS (20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 12 July 2024
Resolved
Oil filtering equipment shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when oil content of the effluent exceeds 15ppm. The vessel’s crew was unable to show proper operation of OCM per manufacturers test procedures. MARPOL Annex I/3.14.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 July 2024
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Cracked welds were found in both the port and STBD lifeboats on the door frames. Props for both port and STBD lifeboats were striking nozzle when put into gear. 74 SOLAS (20) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 July 2024
Resolved
Stowage locations for lifesaving equipment shall be marked with the symbols in accordance with the recommendations of the organization indicating the devices stowed in that location for that purpose. The number of devices shall also be indicated. Lifesaving equipment stowage in ECR was not marked appropriately. 74 SOLAS (20) III/20.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 18 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. FWD Quarters AC vent panel breaker switch broken. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 18 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. 120V on emergency bus showed an active ground displaying on ground device located on the main switch board. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 12 July 2024
Resolved
All lifesaving appliances shall be ready for immediate use.
Lifesaving appliances and equipment are stowed off station.
Rectify prior to activation. 74 SOLAS (20) III/20.2
Action required: 705 - Other - as specified
Resolved 17 July 2024
Resolution: Observed lifesaving appliances was in proper location based on fire safety plan.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 12 July 2024
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. STBD lifeboat davit had a total failure of the clutch and was unable to retrieve lifeboat. 74 SOLAS (20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship will remain fit to proceed to sea. Found junction box hanging from broken supports in cargo hold #2. 74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 February 2022
Resolution: Accepted as a condition of ACS under finding #5146621.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 February 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship will remain fit to proceed to sea. High pressure CO2 bottle set #50's flexible hose was kinked. Provide servicing report from qualified servicing agency to satisfaction of RO. 74SOLAS(20)I/11(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 February 2022
Resolution: Accepted as a condition of ACS under finding #5146621.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 8 February 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat thermal protective aids' approved packaging was deteriorated and torn. 74SOLAS(20)III/20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 February 2022
Resolution: Accepted as a condition of ACS under finding #5146621.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 8 February 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship will remain fit to proceed to sea. Vessel's paint locker supply ventilation, paint locker natural ventilation, and linen locker natural ventilation were unable to be closed. 74SOLAS(20)I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 8 February 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 8 February 2022
Resolved
Found lifeboat #1's flashlight was not FM 1014 standard; vessel found authorized flashlight, corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 February 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 8 February 2022
Resolved
Found lifeboat #1's signaling lamp cable spliced and covered in electrical tape; corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 8 February 2022
Resolution: Corrected on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 February 2022
Resolved
One oxygen bottle was tied to bulkhead; corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 8 February 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 February 2021
Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Starboard lifeboat inoperable.
74 SOLAS (14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 February 2021
Resolved
All life saving appliances shall be in working order and ready for immediate use. Port lifeboat hull seam leaking.
74 SOLAS (14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 3 March 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 February 2021
Resolved
In the vertical direction, such spaces, including those behind linings of stairways, trunks etc shall be closed at each deck. MCT in deck between Captain's Cabin and bridge is unsealed.
60 SOLAS II D/49cii
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 3 March 2021
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 23 February 2021
Resolved
Condition after survey, ship and equipment shall be maintained to conform with the present regulations. Bridge audible power failure alarm inoperable.
74 SOLAS (14) I/11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 3 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2021
Resolved
Condition after survey, ship and equipment shall be maintained to conform with the present regulations. Found hole in lower engine room port forward breaker panel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 3 March 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 February 2021
Resolved
Condition after survey, ship and equipment shall be maintained to conform with the present regulations. Found pinhole leak in bilge ballast pipe.
Action required: 10 - Deficiency Rectified
Resolved 23 February 2021
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 January 2020
Resolved
Upon activation vessel must conduct abandon ship, fire, and security drills to the satisfaction of the attending Marine inspector. 74 SOLAS (14) III/19. ISPS XI-2/4
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 10 January 2020
Resolved 17 September 2020
Resolution: Vessel completed drills; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 January 2020
Resolved
Vessel does not keep up to date charts and publications due to ROS status. Vessel must provide publications and charts to CG marine inspector upon activation. 33 CFR 164.33
Action required: 60 - Rectify deficiencies prior to movement
Due 10 January 2020
Resolved 17 September 2020
Resolution: Vessel has up to date charts and pubs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 January 2020
Resolved
Upon activation vessel is to provide MMCs for all crew members when vessel is fully crewed in accordance with COI manning to the satisfaction of the cg marine inspector. STCW
Action required: 60 - Rectify deficiencies prior to movement
Due 10 January 2020
Resolved 17 September 2020
Resolution: Vessel has manning for activation IAW COI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 January 2020
Resolved
Each lifeboat shall be launched and maneuvered in water by its assigned operating crew at least once every three months during abandon ship drill. Both lifeboats were not launched due to mooring arrangements.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 January 2020
Resolved 17 September 2020
Resolution: Vessel launched the STBD lifeboat; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 January 2020
Resolved
Ship and equipment shall be maintained to conform with the present regulations. Fire damper for STBD crane generator exhaust room is not closing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 14 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 9 January 2020
Resolved
Ship and equipment shall be maintained to conform with the present regulations. Port and STBD embarkation ladders are damaged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 14 January 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 January 2020
Resolved
Ship and equipment shall be maintained to conform with the present regulations. Provide fire servicing report.
Action required: 10 - Deficiency Rectified
Due 23 January 2020
Resolved 10 January 2020
Resolution: Vessel provided satisfactory report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020
Resolved
Ship and equipment shall be maintained to conform with the present regulations.Heat pads attached to various motors in machinery space are spliced to extension cords. Insulate splices to the satisfacion of RO.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 14 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020
Resolved
Ship and equipment shall be maintained to conform with the present regulations. Three soft patches installed below condenser. Provide approval documentation from class to CG Marine Inspector
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 17 January 2020
Resolution: Recieved ABS report number 4090503 stating the "soft patches" were approved for the ballast system in 2016 and are approved STRAUB COUPLINGS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 January 2020
Resolved
Ship and equipment shall be maintained to conform with the present regulations. Sealing and wastage on salt water condenser piping. Mechanically clean and provide gaging report to RO.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 19 February 2021
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 30 January 2019
Resolved
Upon activation vessel must conduct abandon ship, fire, and security drills to the satisfaction of the attending CG Marine Inspector. 74 SOLAS (14) III/19 & ISPS XI-2/4
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Drills conducted, All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 January 2019
Resolved
Vessel does not keep up to date publications and charts due to ROS status. Vessel must provide publications and charts to CG Marine Inpsector prior to ativation.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: New Charts and Pubs are onboard
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 30 January 2019
Resolved
Upon activation vessel is to provide MMCs for all crew members when vessel is fully crewed in accordance with COI manning to satisfaction of the attending CG Marine Inspector. STCW
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Vessel was manned appropriately according to COI and WQSB.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 January 2019
Resolved
Each lifeboat shall be launched and maneuvered in the water by its assigned operating crew at least once every three months during an abandon ship drill. Port lifeboat was not launched due to mooring arrangements. 74 SOLAS (14) III/3.4.3
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Port Lifeboat was launched when vessel moved to Cheatum Annex.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 30 January 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons aboard. Echo depth sounder indicating a low battery alarm. 74 SOLAS (14) I/11(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 February 2019
Resolution: Cleared by ABS Report # NN3627051
Fire Fighting › Fire Main › Valves
Issued 2 December 2015
Resolved
Found fire main bleeder valve from main fire pump leaking at the bottom of the valve body. Repair or replace valve to the satisfaction of the attending class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2015
Resolution: Received email and picture from ABS Class Surveyor attesting to the replacement of the valve.
Fire Fighting › Fire Main › Condition
Issued 2 December 2015
Resolved
Found pinhole leaks in fire main piping from emergency fire pump within forward pump room. Crop and renew piping to the satisfaction of the attending class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2015
Resolution: Received email and picture from ABS Class Surveyor attesting to the replacement of the corroded section of piping.
Navigation › Piloting/Steering › Marine Charts
Issued 2 December 2015
Resolved
Vessel does not have up-to-date charts and navigation publications. Provide up-to-date charts and navigation publications to the satisfaction of the attending USCG Marine Inspector, prior to activation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2017
Resolution: Qualified Marine Inspector witness satisfactory Charts and NAV PUB's.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 December 2015
Resolved
Vessel is currently in ROS status and unable to conduct drills. Conduct fire and abandon ship drills to the satisfaction of the attending USCG Marine Inspector prior to activation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2017
Resolution: Qualified Marine Inspector witnessed satisfactory Fire and Abandon ship drills. Due to the vessels location it was not able to lower Lifeboats, once underway the vessel is to send proof of lowering the lifeboats.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 2 December 2015
Resolved
Vessel is currently in ROS status with reduced crew. Provide valid MMCs for crew members to the satisfaction of the attending USCG Marine Inspector prior to activation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2017
Resolution: Qualified Marine Inspector witnessed valid MMC's for crew members. The vessel met its manning requirements.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 February 2012
Resolved
Prove proper manning and documentation when activated out of ROS status.
Action required: 705 - Other - as specified
Resolved 13 November 2012
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 February 2012
Resolved
Conduct fire drill and abandon ship drill to satisfaction of CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 13 November 2012
Lifesaving › Lifeboat › Propeller
Issued 8 February 2012
Resolved
Port and stbd lifeboat propellers are contacting shroud at bottom and have damaged shroud. These must be repaired to the satisfaction of classification society IAW SOLAS 74/78 III/20.2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2012
Resolved 13 November 2012
Lifesaving › Lifeboat › Markings
Issued 8 February 2012
Resolved
Relabel port & stbd lifeboat, IAW SOLAS 74/78 III/34, and the LSA Code 4.4.9. to the satisfaction of classification society.
Action required: 705 - Other - as specified
Due 31 December 2012
Resolved 8 February 2012
Personnel › Certificates/Documents/Licenses › License, Master
Issued 2 February 2011
Resolved
Vessel in ROS status, upon activation all crew members shall provide proof of license, TWIC, STCW.
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 8 February 2012
Resolution: Closed out and reissued at ACP annual 2/8/2012.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 2 February 2011
Resolved
Vessel in ROS status, prove proper manning in accordance with COI and conduct fire and boat drills.
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 8 February 2012
Resolution: Closed out and reissued at ACP annual 2/8/2012.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 24 February 2009
Resolved
Prove safe manning prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2009
Resolution: Crew documentation all sat.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 February 2009
Resolved
Perform fire and boat drills prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2009
Resolution: Successfully performed drills.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 December 2007
Resolved
smoke detecter gunked up from shipyard work; cleaned and retested sat.
Condition: Improper/Lack of Maintenance
Due 14 December 2007
Resolved 14 December 2007
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 6 December 2007
Resolved
Hospital space accessibility limited due to it being used to store immersion suits (extra). Removed from space and restowed.
Condition: Placed in Improper Service
Due 14 December 2007
Resolved 14 December 2007
Operations/Management › Drills/Instruction › Fire
Issued 23 February 2006
Resolved
Upon activation, and prior to departure, conduct fire and abandon ship/boat drills.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 December 2006
Resolved 14 December 2007
Communications › Alarms/Indicators › General Alarm
Issued 7 January 2005
Resolved
Provide visual general alarms throughout the main machinery space to the satisfaction of the attending class surveyor.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2005
Resolved 12 January 2005
Resolution: Cleared by ABS. A revolving red light had been connected to the general alarm system over the steam turbines.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 February 2004
Resolved
Provide original lisences, STCW certificates and MMD cards, then demonstrate a fire and boat drill prior to getting underway.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 7 January 2005
Navigation › Collision/Grounding Avoidance
Issued 12 February 2004
Resolved
Demonstrate the ability to print echo depth sounder info IAW 33 CFR 164. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 12 March 2004
Resolution: cleared based on ABS report
Engineering › Steering Gear System
Issued 12 February 2004
Resolved
Demonstrate proper operation of audible and visual steering gear power failure alarms located on the bridge. LEGACY COMPONENT DESC: alarm panel
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 12 March 2004
Resolution: Cleared based on ABS report
Documentation › Safety/Response Plans/Programs
Issued 12 February 2004
Resolved
Post the ABS approved colorized version of the fire control/safety plan. Remove all other versions of the fire/safety LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 12 March 2004
Resolution: Cleared base on ABS report.
Construction/Loadline › Structures
Issued 26 February 2002
Resolved
Crack port side between the 1 deep fuel tank and forepeake ballast tank. CrackStrb side between the 1 deep fuel tank and the 1 cargo tank(use for storeing veesl equipment. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 11 July 2002
Lifesaving
Issued 3 May 2000
Resolved
AT NEXT VESSEL ACTIVATION, CONDUCT FIRE AND BOAT DRILLS WITH ENTIRE CREW. BOAT DRILL SHOULD BE CONDUCTED WITH PORT BOAT SINCE VESSEL IS NORMALLY MOORED STARBOARD SIDE.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Documentation
Issued 14 July 1999
Resolved
UPDATE FIRE/SAFETY PLAN AND SUBMIT TO COAST GUARD FOR APPROVAL
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Lifesaving
Issued 10 September 1998
Resolved
AT NEXT VESSEL ACTIVATION, CONDUCT FIRE AND BOAT DRILLS WITH ENTIRE CREW. BOAT DRILL SHOULD BE CONDUCTED WITH PORT BOAT SINCE VESSEL IS NORMALLY MOORED STARBOARD SIDE TO.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Lifesaving
Issued 5 May 1998
Resolved
AT EARLIEST OPPORTUNITY OR NEXT VESSEL ACTIVATION, CONDUCT A FIRE DRILL ANDABANDONSHIP DRILL USING PORT LIFEBOAT.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Construction/Loadline
Issued 12 May 1997
Resolved
ADJUST ALL WATERTIGHT SCUTTLES. CROP AND RENEW, WHERE NEEDED, DOG ENCLOSURES IN SCUTTLE EXPANSION TRUNKS. TO BE COMPLETED BY NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Lifesaving
Issued 12 May 1997
Resolved
PROVIDE TWO (2) EYE WASHES FOR PORT & STBD LIFEBOATS, FIRST AID KITS.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Construction/Loadline
Issued 16 May 1996
Resolved
CROP AND RENEW WASTED VENT LINE FROM TANK TOP TO 4 INCH TRANSITION LINE IN #1 PORT DOUBLE BOTTOM.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Fire Fighting
Issued 16 May 1996
Resolved
MAKE PERMANENT REPAIRS TO PORT FIREMAIN AT FOWARD FIREMAIN CUTOUT VALVE.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
CROP OUT AND RENEW ALL WASTED SHIPS LADDER FOUNDATIONS
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Electrical
Issued 16 May 1996
Resolved
PROVIDED ALL ELECTRICAL DISTRIBUTION PANELS WITH LEDGER CARDS.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Construction/Loadline
Issued 16 May 1996
Resolved
REPACK OR REPLACE ENGINEROOM SLUDGE PUMP
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Construction/Loadline
Issued 16 May 1996
Resolved
CLEAR ALL FEED PUMP DECK DRAINS IN ENGINEROOM.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Documentation
Issued 16 May 1996
Resolved
PROVIDE COPY OF CURRENT CARGO GEAR SAFETY CERTIFICATE.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Fire Fighting
Issued 16 May 1996
Resolved
REPLACE UPPER MOTOR BEARING ON FORWARD FIRE PUMP.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Electrical
Issued 16 May 1996
Resolved
CLEAN OUT CONTACTS ON ALL SHIPS MOTOR CONTROLLERS AND PROVIDE WIRE DIAGRAMSFOR SAME.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Electrical
Issued 16 May 1996
Resolved
INSTALL EXPLOSION PROOF LIGHT GLOBES IN ENGINEERS PAINT LOCKER. ALL ABOVE REQUIREMENTS ARE TO BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Construction/Loadline
Issued 16 May 1996
Resolved
CROP OUT AND RENEW PITTED AFTER BULKHEAD IN LOWER FORWARD PUMPROOM.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Electrical
Issued 16 May 1996
Resolved
REPLACE ALL BROKEN LATCHES ON ELECTRICAL DISTRIBUTION PANELS.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Engineering
Issued 5 May 1994
Resolved
MAKE MAIN ENGINE AVAILABLE FOR INSPECTION AND OPERATIONAL TESTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Construction/Loadline
Issued 5 May 1994
Resolved
MAKE AREA IN WAY OF STRUCTURAL DAMAGE TO HULL AVAILABLE FOR INSPECTION BY AMARINE INSPECTOR PRIOR TO VESSEL DEPARTING PORT._x001C_ _x001C_
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Construction/Loadline
Issued 2 May 1994
Resolved
Make vessel available for inspection prior to it leaving the port.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Engineering
Issued 26 April 1994
Resolved
DEMONSTRATE PROPER OPERATION OF THE FLAME FAILURE ALARMS AND SHUTDOWN FOR THE PORT AND STARBOARD BOILERS.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Electrical
Issued 26 April 1994
Resolved
INSTALL WIRING PROPERLY AND SECURE COVER TO ELECTRICAL CONNECTION BOX IN THE MAIN CO2 ROOM JUST ABOVE THE WATERTIGHT DOOR.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Unknown
Issued 26 April 1994
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE SOUND POWERED PHONE IN THE FORWARD PUMP ROOM.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Engineering
Issued 26 April 1994
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF #1, #2, AND #3 MAIN FEED PUMP REGULATORS ( GOVERNOR CONTROL ).
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Engineering
Issued 26 April 1994
Resolved
.PACK LEAKY STEAM STOP VALVE, NO. 1 MAIN FEED PUMP.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Engineering
Issued 26 April 1994
Resolved
REPAIR/CLEAR AND DEMONSTRATE PROPER OPERATION OF THE FOLLOWING ALARMS (FALSE ALARMS). (A)PORT SPRHTR OUTLET PRESS HI-LO. (B) STBD SPRHTR OUTLET TEMP HI. (C) F/O TEMP STBD BOILER LOW. (D) STBD BOILER SMOKING.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Engineering
Issued 26 April 1994
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE STATUS INDICATOR LIGHTS (RUN/STOP) IN THE CONSOLE FOR FEED PUMPS #1, #2. AND #3.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Deck/Cargo
Issued 7 April 1993
Resolved
REPAIR THE FWD AND AFT MOORING WINCHES AND CONDUCT OPERATIONAL TEST TO THE_x001C_SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Deck/Cargo
Issued 7 April 1993
Resolved
CORRECT TEMPORARY REPAIR TO CARGO HOLD VENTILATION BREAKER; PROPERLY WIRE THE CARGO HOLD BREAKER TO THE SWITCH BOARD IN THE SPACE PROVIDED VICE BEHIND THE SWITCHBOARD. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Engineering
Issued 19 June 1992
Resolved
REPLACE SOOT BLOWER PIPING ASSEMBLY, BOTH BOILERS, WITH AN ASSEMBLY WELDED WITH CG APPROVED WELDING PROCEDURES OR PROVE PROCEDURES USED TO THE SATISFACTION OF [name withheld].
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Documentation
Issued 19 June 1992
Resolved
PROVIDE FLANGE AND VALVE CERTIFICATES FOR CG APPROVAL.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Deck/Cargo
Issued 10 November 1991
Resolved
PROVE PROPER OPERATION OF AFT MOORING WINCHES .
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Documentation
Issued 10 November 1991
Resolved
PROVIDE AND MAINTAIN AN OIL RECORD BOOK IAW 33 CFR 151.25.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Electrical
Issued 10 November 1991
Resolved
PROVIDE PROPER BATTERY BOXES AND CORROSION RESISTANT LININGS FOR BATTERY_x001C_ BANKS IN BOTH FORWARD AND AFT BATTERY LOCKERS IAW 46 CFR 111.15.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Engineering
Issued 10 November 1991
Resolved
CLEAN AND/OR REPLACE TORN FLAME SCREENS.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Engineering
Issued 10 November 1991
Resolved
PROVIDE ADEQUATE FIXED OR PORTABLE CONTAINMENT FOR FUEL OIL & DIESEL OIL VENTS PORTSIDE AFT HOUSE .
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Fire Fighting
Issued 10 November 1991
Resolved
PROVIDE REQUIRED HYDROSTATIC TESTING OF CO2 CYLINDER IN FORWARD PAINT _x001C_ LOCKER AND O2 CYLINDERS IN EMERGENCY EQUIPMENT LOCKERS.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Fire Fighting
Issued 10 November 1991
Resolved
PROPERLY MOUNT FIRE EXTINGUISHER IN LOWER BOSN' STORES.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Electrical
Issued 10 November 1991
Resolved
PROVIDE AND INSTALL A FAN FOR THE PORT ENGINE ROOM VENTILATION SHAFT.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Electrical
Issued 10 November 1991
Resolved
PROPERLY WIRE THE ENGINE ROOM SUPPLY FAN BREAKER AND THE CARGO HOLD VENTILATION BREAKER.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Deck/Cargo
Issued 10 November 1991
Resolved
PROVE PROPER OPERATION OF THE RELIEF VALVE FOR THE #2 STARTING AIR RECEIVERFOR THE DIESEL GENERATORS.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Navigation
Issued 10 November 1991
Resolved
PROVE PROPER OPERATION OF THE LOW LEVEL SUMP ALARM FOR THE STBD STEERING GEAR MOTOR.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Lifesaving
Issued 10 November 1991
Resolved
INSTALL 406 EPRIB WITHIN 30 DAYS OF RECEIPT _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Fire Fighting
Issued 10 November 1991
Resolved
PROVIDE FIXED AND SEMI-PORTABLE FIRE SYSTEM SERVICE CERTIFICATE.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Electrical
Issued 10 November 1991
Resolved
PROVIDE ACCEPTABLE MATTING BEHIND THE DIESEL GENERATOR SWITCHBOARD.
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Engineering
Issued 19 September 1991
Resolved
PROVE PROPER OPERATION OF MAIN STEAM STOP AND THROTTLE VALVES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Accommodation/Occupational Safety
Issued 19 September 1991
Resolved
PROVE PROPER OPERATION OF SHIPS SERVICE AIR COMPRESSOR. THIS REQUIREMENT MAY BE CLEARED BY SUBMITTING A STATEMENT TO [name withheld] ENGINEER THAT AIR COMPRESSOR'S REPAIRED AND OPERATING PROPERLY.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Engineering
Issued 19 September 1991
Resolved
PROVE PROPER OPERATION OF PORT SIDE ENGINE SUPPLY FAN SYSTEM. THIS REQUIREMENT MAY BE CLEARED BY SUBMITTING A STATEMENT TO [name withheld] ENGINEER THAT SYSTEM IS REPAIRED AND OPERATING PROPERLY.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Engineering
Issued 5 September 1991
Resolved
PROVE PROPER OPERATION OF HIGH PRESSURE EXTRACTION BLEED VALVE. OPERATION MUST BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Engineering
Issued 5 August 1991
Resolved
PROVIDE TO THE [name withheld] A COPY OF ALL ABS DAMAGE AND REPAIR REPORTS TO HEAD STEAM VALVE CHEST. REFERENCE CASREP 041415 Z AUG 91.
Condition: Unknown
Due 5 August 1991
Resolved 5 August 1991
Fire Fighting
Issued 27 May 1991
Resolved
REPACK SHAFT ON EMERGENCY FIRE PUMP.
Condition: Unknown
Due 27 May 1991
Resolved 27 May 1991
Fire Fighting
Issued 27 May 1991
Resolved
REPAIR OPERATING CONTROLS OF SEA SUCTION VALVE FOR EMERGENCY FIRE PUMP AND PROVE REMOTE OPERATION OF SAME.
Condition: Unknown
Due 27 May 1991
Resolved 27 May 1991
Engineering
Issued 27 May 1991
Resolved
PROVIDE COPIES OF ALL ABS REPORTS AND CERTIFICATES RELATING TO HIGH SPEED TURBINE REPAIRS TO [name withheld] AS RECEIVED FROM ABS.
Condition: Unknown
Due 27 May 1991
Resolved 27 May 1991
Construction/Loadline
Issued 12 April 1988
Resolved
MAKE PERMANENT REPAIRS TO LONGITUDINAL BULKHEAD, LONGITUDINAL SUPPORTS, SHELL STIFFENERS, SWASH BULKHEADS AND STRINGERS IN #1 & #2 P/S DEEP TANKS AS OUTLINED IN ENCLOSURE 1 (MARAD REPAIR SPECIFICATIONS) OF MARAD CONVERSION TAC-6 LETTER DATED 18MAR88.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Navigation
Issued 12 April 1988
Resolved
OBTAIN CERTIFICATE OF COMPLIANCE FROM [name withheld] DISTRICTFOR THE AFTER MASTHEAD LIGHT DUE TO HORIZONTAL ARC BLOCKAGE OF LIGHT VISIBILITY BY THE VESSEL'S GANTRY CRANES.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Electrical
Issued 12 April 1988
Resolved
PROVIDE FOR EACH CRANE GENERATOR PRIME MOVER AN OVERSPEED DEVICE THAT IS INDEPENDENT OF THE NORMAL OPERATING GOVERNOR AS DEFINED IN 46CFR111.12-1(B)AND PROVE SATISFACTORY OPERATION OF THE SAME.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988