ATLANTIS is a 1997 research vessel. The Coast Guard has recorded 27 inspections since 2016, most recently in June 2026, along with 21 deficiencies and 3 operational controls.
Records from 2016 to 2026. Most recent: inspection, 28 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it3304 - Regulatory (Subpart C or D), Gross Ton 3180 - Convention (Subpart B), Gross Ton 2251 - Displacement, Gross Ton 2247 - Regulatory (Subpart C or D), Net Ton 954 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
Conduct an inspection of the outside of the ship's bottom to the satisfaction of the authorized ACP RO. Vessel ran aground and shall conduct an inspection to prove hull integrity and proper running gear function by next port.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 July 2026
Resolution: ACP-RO Attended satisfactory underwater hull inspection
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2025Resolved
Vessel is not compliant with video and audio surveillance requirements outlined in 46 USC 4901. Vessel is authorized to verified to install equipment at requested May 2025 maintenance period. Vessel is not authorized to operate after that date without compliance.
Action required: 705 - Other - as specified
Resolved 29 May 2025
Resolution: A surveillance system in compliance with 46 USC 4901 has been installed. System was satisfactorily inspected and tested with attending USCG marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 November 2024Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control.
Vessel is operating on an unapproved Period Safety Test Procedure (PSTP), there is a statement of understanding from class. Coast Guard Inspectors observed several issued with the submitted PSTP and crew noted these observation and will make edits. This deficiency will remain open until class approves PSTP that the vessel submitted on 01SEPT2024.
Action required: 705 - Other - as specified
Resolved 3 July 2025
Resolution: Received approval letter from ABS and statement from CHENG that all tests were performed in presence of ABS surveyors.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 December 2023Resolved
11104- Rescue Boats- Each rescue boat and ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Vessel required to replace degraded reflective tape on the rescue boat.
46 CFR 185.604
16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 December 2023
Resolution: Vessel submitted pictures of newly added retro tape.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 December 2023Resolved
07105-Opening in Fire-Resistant Division-Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. Cable penetration insulation was found removed in emergency generator room. Vessel required to replace packing to the satisfaction of the marine inspector.
16 C
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2024
Resolution: Vessel provided photo documentation showing rox blox reinstalled accordingly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 December 2023Resolved
13108 - Operation of Machinery - ll marine engineering details, such as boilers, pressure vessels, main and auxiliary machinery, piping, valves, and fittings, shall be designed, constructed, and installed in accordance with the provisions of this subchapter F. Vessel bow thruster failed to operate due to undetermined cause resulting in the failure to supply power to the system for propulsion. Vessel required to submit documentation to our office attesting to the return of the bow thruster to full operation
46 CFR 50.01-10
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2024
Resolution: 09Jan2024: Provided technician report showing rectified electrical supply returning full operation of bow thruster.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 September 2022Resolved
The release mechanism shall be so designed that the door will automatically close in the event of disruption of the control system or central power supply.
MI observed 03 fire doors which did not latch closed when the release mechanism was activated ( doors: 1-71-2, 02 galley doors 01-46-1).
74 SOLAS (97) II-2/ 30.4.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 5 October 2022
Resolution: Deficiency accepted by class. Finding number 971.1 issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2022Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though on of the essential auxiliaries becomes inoperative.
MI observed no Critical Parts List onboard.
74 SOLAS (04) II-1/26.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 5 October 2022
Resolution: Deficiency accepted by class. Finding number 972.1 issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2022Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
MI observed Oiler life jacket light inoperable.
74 SOLAS (14) III/20.2
Action required: 10 - Deficiency Rectified
Due 23 September 2022
Resolved 23 September 2022
Resolution: Life Jacket light replaced.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 September 2022Resolved
Oil fuel pipes, which if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 liters and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned.
MI observed inoperable shut-off valve.
74 SOLAS (97) II-2/15.2.5
Action required: 10 - Deficiency Rectified
Due 23 September 2022
Resolved 23 September 2022
Resolution: Fuel shut-off valve operational.
The condition of the ship shall be maintained to conform with the provisions of the present regulations.
MI observed the Port escape from emergency steering did not dogged completely. The Starboard was unable to be opened from the steering compartment.
74 SOLAS (14) I/11 (a)
Action required: 10 - Deficiency Rectified
Due 23 September 2022
Resolved 23 September 2022
Resolution: Door adjusted to dog completely.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 September 2022Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization. Samples from all foam concentrates carried on board and subject them to the periodical control tests iaw MSC/Circ. 670.
The foam analysis servicing report was expired.
74 SOLAS (97) II-2/ 9
MSC/Circ. 670
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 5 October 2022
Resolution: Deficiency accepted by class. Finding number 976 issued.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 June 2022Resolved
All lifesaving appliances and arrangements shall be in compliance with 46 CFR Subchapter W. Newly installed engine on rescue boat is not an approved engine model. Replace with authorized engine model and / or approved rescue boat meeting 46 CFR 160.156.
46 CFR 188.27-1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 3 November 2022
Resolution: Vessel has letter for engine approval see vessel documents
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 July 2021Resolved
46 CFR 189.55-1(d)
Fire control. (1) General arrangement plans showing for each deck the control stations, the various fire sections enclosed by fire resisting bulkheads, the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to different compartments and decks and the ventilation system including location of ventilation shutdowns, positions of dampers and the number identifying each system.
Inspect all fire screen doors IAW the approved fire control plan and correct all doors that do not fully close automatically.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2021
Resolved 12 July 2021
Resolution: Cleared by RO.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 July 2021Resolved
46 CFR 113.25-10
In a space described in 113.25-9(a), where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general alarm signal.
Actuation of general alarm contactor resulted in flashing green light in engine room. Correct and demonstrate actuation of flashing red light upon general alarm activation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2021
Resolved 26 July 2021
Resolution: Cleared by RO.
Your vessel must undergo a periodic inspection within 3 months before or after the second or third anniversary (06OCT2021) of the date of your vessel's COI. The later date of this window was 06JAN20 for the 2019 inspection. Vessel is directed to transit directly to home port and conduct no operations en route. Make vessel available for periodic inspection (scheduled with MSD Cape Cod for 26MAR20) prior to operations.
Action required: 705 - Other - as specified
Resolved 26 March 2020
Resolution: Vessel conducted an annual inspection with ABS
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 March 2019Resolved
Ready means of Escape. Provide proper operation of the four (4) main deck emergency escape scuttles from the engineering spaces. Hatches found stuck closed and unable to be opened by attending inspectors. 74SOLAS(97)II-2/45
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 March 2019
Resolved 22 March 2019
Resolution: ABS witnessed sat operation of all engineering space escape hatches. SF3603731 #899
Vessel shall satisfactorily demonstrate operation of the port and stbd azimuthing drive units. 74SOLAS(04)II-1/29,30,31
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2019
Resolved 22 March 2019
Resolution: ABS witnessed sat operation of both Z drives. SF3603731 #862
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 March 2019Resolved
Provide adequate closure for 2" wire pass-through into
the E/R emergency escape trunk on the port side main
deck. 74SOLAS(04)II-1/3-1
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 8 March 2019
Resolved 22 March 2019
Resolution: Witnessed sat closure by ABS. SF3603731 #861
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 March 2019Resolved
Prove satisfactory operation of the damage control locker vent closure devices. Ship unable to close two 3"
vent covers at the damage control locker. 74SOLAS(97)II-2/2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2019
Resolved 22 March 2019
Resolution: Witnessed sat closure by ABS. SF3603731 #861
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 March 2019Resolved
Machinery space bilge alarm did not provide audible alarm on bridge. Corrected during inspection. 74SOLAS(04)II-1/51
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 7 March 2019
Resolved 7 March 2019
Resolution: Crew fixed during inspection.