Inspection history · 15
1 March 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7404093
30 April 2021
Administrative Inspection · Load Line/Change of Employment · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7186637
10 November 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7126828
7 July 2020
In-Service Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7018157
21 February 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6932352
29 August 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6798485
18 June 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6447776
11 June 2018
Deficiency Check · Drydock Exam · Periodic Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6441293
5 March 2018
Initial Construction-Excluding Oversight · In-Service Inspection · Plan Review (Other than "T") · Administrative Inspection · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6371475
7 December 2017
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6320974
4 October 2017
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6277456
9 March 2017
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6102013
7 September 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5996684
18 August 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5977399
20 May 2016
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5892814
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 August 2020
Resolved
Where the operating rods pass through a deck, gastight stuffing boxes shall be fitted. Multiple reach rod stuffing boxes were identified as unsecured and ullage gaskets found to deteriorated. All cargo tanks shall be verified as gas tight by attending MI prior to the onload of any cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2022
Resolution: Vessel scrapped on 01JUN2021 in Brownsville, TX.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 August 2020
Resolved
Grade B or C liquids. Cargo tanks in which Grade B or C liquids are to be transported shall be fitted with either individual pressure-vacuum relief valves which shall extend to a reasonable height above the weather deck or shall be fitted with a venting system consisting of branch vent lines connected to a vent header which shall extend to a reasonable height above the weather deck and be fitted with a flame arrester or a pressure-vacuum relief valve. All cargo tank PV valve shall be tested to verify proper lifting setting on both pressure and vacuum sides prior to the onload of any cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2022
Resolution: Vessel scrapped on 01JUN2021 in Brownsville, TX.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 September 2019
Resolved
All pressure vessels must be provided with protective devices. 1st Stage Heater for main propulsion does not have relief valve installed. Install pressure relief valve downstream and tag open valve between heat exchanger and Pressure relief valve until it can be properly installed.
46 CFR 54.15-5 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2019
Resolved 1 October 2019
Resolution: Safety Relief Valve installed on 1st stage heater.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 September 2019
Resolved
Anesthetics, drugs, and medicines must be stowed and dispensed in accordance with the DHHS Publication No. (PHS) 84-2024. Medical locker in hospital space contained expired medicine. Remove all expired medicine.
46 CFR 147.105
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 September 2019
Resolved 1 October 2019
Resolution: Expired medicine removed and replaced.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 5 March 2018
Resolved
VESSEL FOUND WITH UPWARDS OF A DOZEN HOLES IN THE INERT GAS SUPPLY PIPING. VESSEL SHALL NOT USE THE INTERT GAS SYSTEM UNTIL PROPER REPAIRS ARE MADE. 46 CFR 32.53-10 (b)
*voluntary compliance IAW MARAD/USCG MOU
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2018
Resolution: item cleared during dry dock exam ACT#6441293
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 5 March 2018
Resolved
VESSEL FOUND WITH HOLES IN BOTH PORT AND STBD CARGO MANIFOLD CONTAINMENTS. VESSEL SHALL NOT TRANSFER OIL OR HAZARDOUS MATERIAL WITHOUT PROPER CONTAINMENTS IN PLACE.33 CFR 155.310
*voluntary compliance IAW MARAD/USCG MOU
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2018
Resolution: item cleared during dry dock exam ACT#6441293
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 5 March 2018
Resolved
VESSELS INERT GAS SYSTEM DECK SEAL FOUND HEAVILY DETERIORATED AND HOLED. VESSEL SHALL CONDUCT PROPER REPAIRS PRIOR TO USING THE INERT GAS SYSTEM. 46 CFR 32.53-10 (b)
*voluntary compliance IAW MARAD/USCG MOU
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2018
Resolution: item cleared during dry dock exam ACT#6441293
Construction/Loadline › Structures › Ventilators
Issued 5 March 2018
Resolved
VESSEL FOUND WITH SOFT PATCHES ON THE #2 PUMP ROOM SUPPLY FAN DUCT & PEDESTAL. VESSEL SHALL ENSURE PROPER REPAIRS ARE CONDUCTED PRIOR TO LOADING/DISCHARGING FLAMMABLE/COMBUSTABLE LIQUIDS. 46 CFR 170.005(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2018
Resolution: item cleared during dry dock exam ACT#6441293
Fire Fighting › Fixed Deck Foam System › Piping
Issued 5 March 2018
Resolved
VESSEL FOUND WITH FIBERGLASS PATCH ON THE FIRE MAIN AT STATION . VESSEL SHALL CONDUCT PERMANENT REPAIRS AT THE UPCOMING DRY-DOCK. 46 CFR 31.10-18(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 August 2018
Resolution: item cleared during dry dock exam ACT#6441293
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2018
Resolved
DURING THE INTERNAL STRUCTURAL EXAM, FOUND THE FOLLOWING AREAS IN NEED OF REPAIR: -MAIN DECK SCUPPER HOLED AT FR.69-70 PORT SIDE
-DEEP PIT FOUND IN #2C BOTTOM PLATE AT FR.93-94 BETWEEN THE 2ND AND 3RD LONGITUDINALS STBD FROM CENTER
-DEEP PITS FOUND IN #3C BOTTOM PLATE AT FR.92-93 BETWEEN THE 1ST AND 2RD LONGITUDINALS STBD FROM CENTER
-ACCESS LADDER TO #1 PORT WBT DEEP TANK WASTED
-DETERIORATED PLATING IDENTIFIED AT STBD SEA CHEST IN THE ENGINE ROOM AT FR. 45-46
-PORT SIDE SHELL PLATING AT FR.34-41 PORT BETWEEN TANK TOP AND 4TH STRINGER CORRODED PAST ALLOWABLE LIMIT
-STBD SIDE SHELL PLATING AT FR.39-41 & 44-46 NEAR SEA CHEST IN THE ENGINE ROOM CORRODED PAST ALLOWABLE LIMIT
-STBD SIDE SHELL PLATING AT FR.49-55 IN THE FIRE ROOM NEAR TANK TOP CORRODED PAST ALLOWABLE LIMIT
-PORT SIDE SHELL PLATING AT FR.55-58 IN THE FIRE ROOM NEAR TANK TOP CORRODED PAST ALLOWABLE LIMIT
-PORT SIDE SHELL PLATING AT FR.17-18 CORRODED PAST ALLOWABLE LIMIT-STBD SIDE SHELL PLATING AT FR.18-20 CORRODED PAST ALLOWABLE LIMIT 46 CFR 31.10-21(c)
Action required: 705 - Other - as specified
Resolved 3 August 2018
Resolution: item cleared during dry dock exam ACT#6441293
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2018
Resolved
TO COMPLETE INTERNAL STRUCTURAL EXAM, THE FOLLOWING AREAS NEED TO BE ENTERED AND INSPECTED;
-AFT PEAK TANK
-7C TANK
-PUMP ROOM BOTTOM PLATING
46 CFR 31.10-21
Action required: 705 - Other - as specified
Resolved 3 August 2018
Resolution: item cleared during dry dock exam ACT#6441293
Fire Fighting › Fire Main › Condition
Issued 18 August 2016
Resolved
Secure leaking from fire pump overboard relief valve packing.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 9 March 2017
Resolution: Packing replaced, tested pump.
Fire Fighting › Combustible Materials › Insulation
Issued 18 August 2016
Resolved
Re-fasten lagging on steam drain in main space near g/s fire pump.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 9 March 2017
Resolution: Lagging re-fastened.
Construction/Loadline › Hull › Bracket
Issued 18 August 2016
Resolved
Weld bracket for bilge injection valve mount.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 9 March 2017
Resolution: Bracket welded.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 18 August 2016
Resolved
Properly secure all high pressure cylinders in machinery spaces.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 9 March 2017
Resolution: Cylinder brackets provided.
Construction/Loadline › Structures › Deck Plating
Issued 18 August 2016
Resolved
Repair wasted deck plate in port forward lower deck main space overhead.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 5 September 2019
Resolution: Verified there was no wasted deck plate in this area.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 August 2016
Resolved
Provide metallic ties for wire runs on bulkhead near aux diesel generator.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 9 March 2017
Resolution: Metallic ties provided.
Documentation › Logs/Records › Oil Record Book
Issued 18 August 2016
Resolved
Sign page 49 or Oil Record Book.
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 9 March 2017
Resolution: ORB signed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 August 2016
Resolved
Repair damaged deck rail at the starboard bow
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 9 March 2017
Resolution: Rails repaired.