MAURY USCG vessel records
← All vessels

SIGNET COURAGEOUS

Built
2008
Last inspected
23 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 23 July 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 15 calendar years (2008–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9430507
WDK6790
932689
Flag
UNITED STATES
Maury page id
psix-932689

Documentation record

Registered dimensions (L × B × D)91.5 ft × 40.0 ft × 17.4 ft
Registered tonnagegross 293 / net 108
ITC dimensions (L × B × D)91.5 ft × 40.0 ft × 17.4 ft
ITC tonnagegross 456 / net 136
BuilderJM MARTINAC SHIPBUILDING CORP · TACOMA, WA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPASCAGOULA, MS
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 15 October 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it456 - Convention (Subpart B), Gross Ton
293 - Regulatory (Subpart C or D), Gross Ton
136 - Convention (Subpart B), Net Ton
108 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 26 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 26

23 July 2026 COI Inspection · Vessel Attendance · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8433876
28 July 2025 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8228036
6 November 2024 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8031489
31 August 2024 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7993187
15 February 2024 Administrative Inspection · TPO Audit
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7878740
2 March 2022 ISM SMC Audit
Administrative · Commandant (CG-CVC) · Activity 7625423
3 August 2021 Initial Certification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7235685
16 June 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6978480
17 December 2018 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6599135
26 November 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6587572
9 November 2018 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6578268
9 November 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6580886
11 September 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6265103
12 May 2017 Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6144743
7 September 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5996684
12 November 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6320429
25 August 2015 Deficiency Check · MTSA Verification · Administration
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5228688
3 May 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5117935
20 August 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4704674
26 July 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4392433
18 February 2012 Type not recorded
No type recorded · Maritime Safety & Security Team Seattle (91101) · Activity 4253104
17 May 2010 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3740624
5 April 2010 Industry Initiated Exam · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3709477
20 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3683008
27 February 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3439947
5 August 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3304261

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 July 2026 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. During testing of remote fuel shutoff valves, the starboard side day tank and double bottom fuel tank both experienced failures of remote shutoff mechanical components rendering them non-operational.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 July 2026
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 2 March 2022 Resolved
The SMS should include procedures ensuring that nonconformities, accidents and hazardous situations are reported to the Company, investigated and analyzed with the objective of improving safety and pollution prevention. The USCG issued a 835 to the vessel on 03 August 2021 referencing Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing in case of fire. Both port and stbd engine room ventilation closures/closing devices were found inoperable. The 835 was closed out by USCG on 05 August on 2021. No objective evidence was provided that the vessel nor the company had included this deficiency in their NCR tracking date to prevent future occurrence. Further there is no procedure in the SMSM to instruct Master/Crew to forward the USCG issued 835 to DPA & Concerned Department. ISM Clause : 9.1
Action required: 705 - Other - as specified
Due 2 April 2023
Resolved 1 April 2022
Resolution: CAP accepted.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 March 2022 Resolved
10.1 The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules & regulations and with any additional requirements, which may be established by the Company. 10.2. In meeting these requirements the Company should ensure that: 10.2.1 inspections are held at appropriate intervals; 10.2.2 any nonconformity is reported with its possible cause, if known; 10.2.3 appropriate corrective action is taken; 10.2.4 records of these activities are maintained. SMSM: 10.1 Maintenance. Evidence: The vessel raised a work repair request on 03 June 2021 for Repairs to the Bridge window. The Repair Requisition was approved by the company but its still in open state and pending repairs to date. Further no action was taken by the company to initiate a Management of Change (MOC) to extend or address a approximate timeline for completion of the repairs. Nature of Non-Conformance: The requirements of maintaining repairs in proper time frame was not followed. ISM Clause : 10.2
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 1 April 2022
Resolution: CAP accepted by RO.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 August 2021 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing in case of fire. Both port and stbd engine room ventilation closures/closing devices were found inoperable. Repair or replace to the satisfaction of a marine inspector. 46 CFR 144.605
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2021
Resolution: Crew repaired ventilation closures and completed operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 November 2018 Resolved
Diagnose and repair issue preventing generator from taking an electrical load.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2018
Resolution: Replaced water pump on #1 SSDG. Replaced ECMI and F/O Pmp on #2 SSDG. Both SSDG's took load with no incidents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 November 2018 Resolved
The crew of each towing vessel must demonstrate the ability to operate the primary and auxiliary machinery and electrical systems for which they are responsible, and to do so under normal and emergency conditions. The automation system that activates the secondary generator upon loss of power of the primary generator is nonfunctional; system requires repair to function as designed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2018
Resolution: (1) Main switchboard breaker charge motor assembly was replaced. (2) A loose connection on a blocking diode in the PLC input circuit was re-connected by the service technician. (3) A loose faulty fuse was replaced by service technician.

Recorded names · 1

PACIFIC STAR (2008–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.