MAURY USCG vessel records
← All vessels

MATSONIA

MATSONIA is a 1973 freight ship. The Coast Guard has recorded 52 inspections since 2016, most recently in January 2024, along with 71 deficiencies, 3 operational controls and 12 casualty investigations between 2003 and 2024.

Records from 2003 to 2024. Most recent: inspection, 23 January 2024.

Built
1973
Last inspected
23 January 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 January 2024
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7334204
Flag
UNITED STATES
Maury page id
psix-47759

Documentation record

Tonnage as PSIX records it19301 - Regulatory (Subpart C or D), Gross Ton
33095 - Convention (Subpart B), Gross Ton
13002 - Regulatory (Subpart C or D), Net Ton
13218 - Convention (Subpart B), Net Ton
22244 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 52

23 January 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7916062
13 December 2021 Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7373273
1 January 2020 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6893197
23 December 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6878265
23 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6819357
4 September 2019 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6804218
7 June 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6706338
30 May 2019 Periodic Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6700349
23 May 2019 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6691764
16 May 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6686592
10 April 2019 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6659874
21 February 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6630595
20 February 2019 Administrative Inspection · Damage Survey · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6629814
14 February 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6629007
21 November 2018 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6585133
13 November 2018 Deficiency Check · Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6579861
10 October 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6564020
19 April 2018 Deadweight Survey · Deficiency Check · ACP Additional Oversight – Risk Assessment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6395500
4 April 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6384832
28 February 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6363226
27 February 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6364969
26 February 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6362053
22 February 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6362844
21 February 2018 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6359972
21 February 2018 Damage Survey · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6386955
31 January 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6351543
11 October 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6285952
10 October 2017 MTSA/ISPS Verification · Deficiency Check · Re-Inspection · ACP COI Oversight · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6285125
20 August 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6340036
4 July 2017 Drydock Exam · ACP Additional Oversight – Risk Assessment · Internal Structural Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6197392
2 June 2017 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6163550
25 May 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6155819
15 April 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6126679
13 April 2017 Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6126607
15 January 2017 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6071837
13 January 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6072220
28 December 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6063299
26 December 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6062471
24 December 2016 Examination of Repairs · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6062065
9 December 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6056638
19 October 2016 Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6241692
28 July 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5956180
28 July 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5963323
8 July 2016 Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5934493
14 June 2016 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5908099
26 April 2016 Damage Survey · ACP Periodic Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5863410
19 March 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5836409
11 March 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5833060
3 February 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5830409
2 February 2016 Damage Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5809018
15 January 2016 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5798339
7 January 2016 ACP Annual Oversight
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5793350

Deficiency record · 71

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 December 2019 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulations XI-1/1. The crew of the vessel observed water coming from the top of the #3B port double bottom ballast tank during the vessel's last voyage from Honolulu to Oakland. On further investigation, a hole approximately 3 inches long was found in cargo hold number 3 on the portside near the bilge well. It is on the lower level of this two level tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 December 2019
Resolution: Referred to Class
10 - Safety of Navigation › N/A - No Subsystem › Automatic radar plotting aid (ARPA)
Issued 23 September 2019 Resolved
An automatic radar plotting aid (ARPA) shall be fitted on ships constructed before September 1, 1984, that are not tankers, if of 15,000 gross tonnage and upwards, by September 1, 1988. [name withheld] reported all three radars are not receiving gyro input signals and the ARPA is not operating as originally designed and approved by the Administration. The Master's standing orders require the Officer in Charge of the Navigation Watch (OINW) to manually input the gyro heading in the ARPA for overall system functionality. Provide a technicians service report to attest to the repair and functionality of the vessel's ARPA as originally designed and approved by the Administration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2019
Resolved 4 October 2019
Resolution: Received a technician report attesting to repairs. Received a class surveyor report from the RO attesting to the repair and functionality of the three radar units.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 30 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Noted five areas with holes in the garage decks on the aft end of the vessel. On the 01 and 02 decks there are five holed locations (three on the 01 deck and two on the 02 deck). Holes range in size from 2 to 6 inches and are located near the rail stanchion on the forward side of the garage. Affect temporary repairs within 30 days and permanent repairs at next drydock. SOLAS 74 I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 6 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The #2 fuel nozzle insert fitting on the starboard boiler is leaking water. Repair leak by date specified. SOLAS 74 I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 6 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 30 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. 'Closed' indicator light on the bridge console for the watertight door was inoperable. Demonstrate proper operation of light. SOLAS 74 I/11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Resolution: Crew replaced bulb.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 30 May 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Steering pump failure indicator light on the bridge console was inoperable. Demonstrate proper operation of light. SOLAS 74 I/11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Resolution: Bulb replaced.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 February 2019 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Based on damage discovered in the #4S Deep Tank, internal inspection of the mirror tank #4P is required. Clean and certify safe for entry #4P Deep Tank to allow for internal inspection by attending marine inspector. 74 SOLAS (14 Cons.) I/11
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2019
Resolution: Tank was sufficiently cleaned and inspection did not reveal any damage/fractures.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 February 2019 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. CO2 line leading from the ramp down to the lower auto deck is holed after it penetrates the bulkhead on the #2 car deck into the storage area. Affect permanent repairs to holed CO2 line to the satisfaction of attending marine inspector. 74 SOLAS (14 Cons.) I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2019
Resolution: Witnessed satisfactory repair to CO2 line.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 February 2019 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Fire dampers on #2 car deck were missing adequate securing devices. Fire dampers for ventilation closure 100 were missing washers and cotter pins, fire damper for ventilation closure 102 was secured with a bent and excessively unthreaded bolt. Repair dampers to the satisfaction of attending marine inspector. 74 SOLAS (97 Cons.) II-1/16.9
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2019
Resolution: Verified proper repairs to dampers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 13 November 2018 Resolved
Maintenance, testing, and inspections of lifesaving appliances shall be carried out having due regard to ensuring reliability of such appliances. Port lifeboat davit foundation bolts found heavily wasted and portions of the foundation supports holed. Vessel shall renew wasted bolts and repair support damage IAW OEM guidance. 74 SOLAS 2014 Cons. III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2018 Resolved
After any survey, no change shall be made in the machinery covered by the survey without the sanction of the administration. Vessel found with alterations made to oil cooler piping systems on both feed water pumps without approval from USCG or class. Vessel shall obtain approval and prove proper operation of the new piping. 74 SOLAS 2014 Cons. I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 November 2018 Resolved
The company should establish procedures and plans for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Vessel found not complying with SMS procedures or good marine practices on lock-out/tag-out. Company shall conduct an internal audit focusing on lock-out/tag-out policies and procedures to ensure the safety of the crew and vessel. 33 CFR 96.100 ISM Code Part A/7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 30 November 2018
Resolution: Received Matson internal audit dated 11-29-18 with findings and action taken.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 13 November 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel found with inoperable general alarm bell in the steering space. 74 SOLAS 2014 Cons. I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 November 2018 Resolved
Spaces containing highly flammable stores shall be so situated as to minimize the danger to crew in case of a fire. Vessel found with flammable liquids improperly stored in the steering gear space. Vessel shall ensure flammable stores are relocated to a paint locker. 60 SOLAS Ch.II/46
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 13 November 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Ships steam piping found missing insulation in various locations throughout creating burn hazard to crew. Crew shall renew missing insulation. 74 SOLAS 2014 Cons. I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Support bracket for aux steam line on lower level stbd side of the stack is unsecured, crew shall ensure support is secured to prevent undue stress to piping. 74 SOLAS 2014 Cons. I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2018 Resolved
After any survey, no change shall be made in the machinery covered by the survey without the sanction of the administration. Vessel found with epoxy soft patch on steam piping flange just aft of the main circulating pump. Vessel shall repair to the satisfaction of class. 74 SOLAS 2014 Cons. I/11(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 November 2018 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the un-pierced bulkhead and weathertight when closed. The watertight door leading from the galley reefer onto the main deck has a 2 inch hole at the bottom of the frame. Affect proper repairs to maintain watertight integrity. ICLL ANN I/12.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 November 2018 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Fire damper for boatswain’s stores on port side main deck and gear locker on port side boat deck are inoperable and are to be repaired. 74 SOLAS 2014 Cons. I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 November 2018 Resolved
A duplicate set of fire control plans shall be permanently stored in prominently marked weather-tight enclosure outside the deck house. Deck canister for fire control plan on port side ladder leading up from the main deck is seized closed. Perform servicing on canister to ensure it is immediately accessible. 74 SOLAS 14 Cons. II-2/15.2.4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2018 Resolved
Firefighting systems and appliances shall be maintained ready for use. Stbd lifeboat fire extinguisher found undercharged. (replacement delivered during inspection) 74 SOLAS 14 Cons. II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2018
Resolved 13 November 2018
Resolution: Replacement extinguisher delivered to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 13 November 2018 Resolved
Maintenance, testing, and inspections of lifesaving appliances shall be carried out having due regard to ensuring reliability of such appliances. Vessels port side davit anchors for the lifeboat falls found heavily wasted. Vessel shall renew anchor brackets in keeping with manufactures guidelines and conduct satisfactory weight test. 74 SOLAS 2014 Cons. III/20.3.1
Action required: 15 - Rectify deficiencies by next port
Due 20 November 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 13 November 2018 Resolved
Maintenance, testing, and inspections of lifesaving appliances shall be carried out having due regard to ensuring reliability of such appliances. Vessel stbd lifeboat davit foundation found with wastage. Vessel shall remove excess scale/paint to allow for inspection of foundation to ensure continued reliability. 74 SOLAS 2014 Cons. III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 20 November 2018
Resolved 4 December 2018
Resolution: Added to ABS Survey for correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 October 2018 Resolved
Starboard Davit for life boat wire rope sheave blocks weld failed, resulting in damage to the wire rope.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 October 2018
Resolved 11 October 2018
Resolution: Repaired and wire rope replaced.
Lifesaving › Lifeboat › Propulsion Engine
Issued 19 April 2018 Resolved
All lifesaving appliances shall be kept in working order and available for immediate use before the ship leaves port. Vessel's motor lifeboat was unable to start in the presence of the attending MI.
Action required: 10 - Deficiency Rectified
Due 19 April 2018
Resolved 19 April 2018
Resolution: Lift pump for the fuel system was replaced and engine tested and operated in water under load in the prescence of the attending MI.
Engineering › Steam Boiler (propulsion) › Gauge Glass
Issued 19 April 2018 Resolved
Each boiler is to have at least two means of indicating the water level. The stbd boiler upper gauge glass is obscured and unable to be read. The port outboard gauge glasses are leaking and out of commission.
Action required: 10 - Deficiency Rectified
Due 19 April 2018
Resolved 19 April 2018
Resolution: Gauge glasses were replaced and tested in teh rpescence of the attending MI.
Engineering › Sea-water System (primary cooling) › Pump
Issued 19 April 2018 Resolved
After any survey of the ship has been completed, no change shall be made to the machinery covered by the survey without sanction of the Administration. Aft circulation pump for main condenser shaft seal is leaking excessively. Renew shaft packing on pump and reduce salt water discharge from pump into bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 1 June 2018
Resolution: Rectification confirmed by attending surveyor [name withheld]3506071 OSR 1636.
Fire Fighting › Fire Hydrants › Condition
Issued 19 April 2018 Resolved
After any survey of the ship has been completed, no change shall be made to the equipment covered by the survey without the sanction of the administration. The #14 and #19 fire station have areas of severe corrosion on the piping. Vessel is to gauge ppiping and provide prosposal for repair or remediation of corrosion areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 1 June 2018
Resolution: Rectification confirmed by attending surveyor [name withheld]3506071 OSR 1631.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 19 April 2018 Resolved
After any survey of the ship has been completed, no change shall be made to the equipment covered by the survey without the sanction of the administration. The winch control cabinet covers in the bosun stores are currently being maintained in a closed position by ratchet straps and rope. Vessel is to secure panels and access doors to satisfaction of attending MI or ACS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 3 May 2018
Resolution: Rectification confirmed by attending surveyor [name withheld]3492975 OSR 1623
Engineering › Steam System (main) › Lagging/Insulation
Issued 19 April 2018 Resolved
After any survey of the ship has been completed, no change shall be made to the equipment covered by the survey without the sanction of the administration. Vessel is missing lagging on flange to evap live steam inlet and the valve bonnet on stbd boiler aft. Vessel is to install lagging to prevent hazards to engine personnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 3 May 2018
Resolution: Rectification confirmed by attending surveyor [name withheld]3492975 OSR 1621
Electrical › Electric Supply System (service) › Cable
Issued 19 April 2018 Resolved
After any survey of the ship has been completed, no change shall be made to the equipment covered by the survey without the sanction of the administration. Stbd winch disconnect switch box on main deck has split electrical stuffing tube and severely corrode conduit to switch box. Renew stuffing tube and conduit to the satisfaction of the attending MI or ACS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 3 May 2018
Resolution: Rectification confirmed by attending surveyor [name withheld]3492975 OSR 1620
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 21 February 2018 Resolved
In accordance with the vessel's submitted mediation plan to minimize any oil loss from the vessel's forward strut seal and the vsl's monitoring plan while underway, the vessel may proceed to Honolulu and return to Oakland to effect permanent repairs (OOA 06 March 18).
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 9 March 2018
Resolution: 3 lip seals replaced IAW manufactures instructions and overseen by ABS. See ABS report SF3464880 for details.
Engineering › Steam System (main) › Piping Drain
Issued 1 November 2017 Resolved
Crop and renew holed section of boiler blowdown pipe downstream of skin valve. SOLAS (2014 Consolidated) I-11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2017
Resolution: SF3406844/1502
Engineering › Steam System (main) › Piping
Issued 1 November 2017 Resolved
Repair leaking high pressure gauge piping on inboard feedwater pump.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1250
Engineering › Feedwater/Condensate Water System › Pump
Issued 1 November 2017 Resolved
Repair water leak from jacking bold on outboard feedwater pump.
Action required: 705 - Other - as specified
Resolved 16 November 2017
Resolution: SF3413702/1521
Engineering › Steam Turbine (auxiliary) › Coupling
Issued 1 November 2017 Resolved
Repair leak from cover of high speed coupling on outboard SSTDG.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1514
Engineering › Steam Boiler (propulsion) › Water Level Indicator
Issued 1 November 2017 Resolved
Repair leak on inboard steam drum sight glass for stbd boiler.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1519
Engineering › Steam System (auxiliary) › Piping
Issued 1 November 2017 Resolved
Determine extent of leaks and make repairs to aux steam line leading to evaporator.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1504
Engineering › Steam Boiler (propulsion) › Air Register
Issued 18 October 2017 Resolved
Re-fasten port forced draft fan linkage. SOLAS (2014 Consolidated) I-11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2017
Resolution: SF3406844/1512
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 October 2017 Resolved
Re-attach linkage for EDG fire damper, prove proper operation. SOLAS (2014 Consolidated) I-11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2017
Resolution: SF3406844/1511
Engineering › Steam Boiler (propulsion) › Water Level Indicator
Issued 18 October 2017 Resolved
Make manual steam drum water level indicators readable. SOLAS (2014 Consolidated) I-11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2017
Resolution: SF3413202/1519
Engineering › Steam System (main) › Lagging/Insulation
Issued 18 October 2017 Resolved
Replace missing lagging on inboard feedwater pump. SOLAS (2014 Consolidated) I-11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2017
Resolution: SF3413702/1521
Engineering › Steering Gear System › Pump
Issued 18 October 2017 Resolved
Make steering system available for inspection/testing following repairs for excessive vibration. 46CFR91.25-10
Action required: 705 - Other - as specified
Resolved 19 October 2017
Resolution: Steering tests sat.
Engineering › Steam System (main) › Piping Drain
Issued 18 October 2017 Resolved
Prove repairs of port sootblower drain with operational test.
Action required: 705 - Other - as specified
Resolved 19 October 2017
Resolution: SF3399445/1491
Engineering › Steam System (main) › Piping
Issued 18 October 2017 Resolved
Prove proper operation of port economizer following repairs.
Action required: 705 - Other - as specified
Resolved 19 October 2017
Resolution: SF3399445/1489
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 October 2017 Resolved
Update lock-out, tag-out log.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1522
Engineering › Steam System (main) › Piping Drain
Issued 18 October 2017 Resolved
Repair leaking main condensor drain pipe.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1508
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 October 2017 Resolved
Repair wasted step in between main condensor pumps.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1495
Engineering › Steam System (main) › Lagging/Insulation
Issued 18 October 2017 Resolved
Re-attach loose lagging on DC heater.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1509
Engineering › Bilge Water Management System › Pump
Issued 18 October 2017 Resolved
Make #2 aux engineering nuisance bilge water pump operable.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1513
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 October 2017 Resolved
Re-attach remote reach rod for fuel oil valve in main space.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1512
Engineering › Steam System (main) › Lagging/Insulation
Issued 18 October 2017 Resolved
Survey main space for missing, unserviceable, and loose lagging, develop plan to repair.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1509
Operations/Management › Pollution › Retention of Oily Mixture
Issued 18 October 2017 Resolved
Remove excess oil under SSTDG's.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1514
Engineering › Steam Boiler (propulsion) › Piping
Issued 18 October 2017 Resolved
Adjust packing on port main steam stop to prevent excessive steam leaking.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1515
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 October 2017 Resolved
Replace weeping exterior fuel oil valve for EDG.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1510
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 October 2017 Resolved
Test motorized lifeboat fuel tank to dertermine how excessive water was found inside the tank, make repairs as necessary.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1516
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 18 October 2017 Resolved
Provide records of periodic automation testing being completed within the last year.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1496
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 October 2017 Resolved
Repair all damaged cargo hatch fire dampers. (ILLC 1966 Reg 16(4))
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1495
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 October 2017 Resolved
Stow lifeboat equipment in port and starboard lifeboats that does not interfere with operations. (1960 SOLAS III/12)
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1517
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 18 October 2017 Resolved
Properly seal multiple cat-5 cable wire penetrations going through the deck of the port fan room. (1960 SOLAS II/38(a))
Action required: 705 - Other - as specified
Resolved 19 October 2017
Resolution: SF3399445/1495
Electrical › Lighting (service) › Lighting Fixture
Issued 18 October 2017 Resolved
Repair electrical lamp and outlet in Stock Tender Room #2. (1960 SOLAS II/27(a)(v))
Action required: 705 - Other - as specified
Resolved 19 October 2017
Resolution: SF3399445/1495
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 18 October 2017 Resolved
Repair broken latch on boiler casing door on the galley deck. (1960 SOLAS II/38(d))
Action required: 705 - Other - as specified
Resolved 19 October 2017
Resolution: SF3399445/1494
Lifesaving › Immersion Suits › General
Issued 18 October 2017 Resolved
Ensure each crew member has an appropriately sized immersion suit for use. (2014 SOLAS III/32.3.2)
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: SF3413702/1518
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 10 October 2017 Resolved
Make vessel available for boiler automation testing by a USCG Marine Inspector during a [name withheld] port call.
Action required: 705 - Other - as specified
Resolved 1 November 2017
Resolution: Testing satisfactory. SF3406844/1496
Engineering › Sea-water System (primary cooling) › Pump
Issued 10 October 2017 Resolved
Tighten packing on main condensor fwd pump to slow excessive leaking.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1495
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 October 2017 Resolved
Provide appropriate blank for main electrical panel opening.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: SF3406844/1495
Engineering › Steering Gear System › Rudder Bearing
Issued 28 December 2016 Resolved
Lower rudder bearing seal is leaking. Found improper seal materials/installation.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2016
Resolution: Packing replaced as per ship's drawing. 4 3/4/x3/4" packing and 1 1x3/4" neoprene seal. Witnessed op test, all sat.
Engineering › Steering Gear System › Ram Seal
Issued 24 December 2016 Resolved
Make repairs to the packing gland and the removal of oil from the rudder stock void prior to leaving next US port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 December 2016
Resolved 30 December 2016
Resolution: Seal Replaced
Engineering › Thrusters › Seal
Issued 28 July 2016 Resolved
Secure hydraulic lines to bow thruster until repair at next drydock to prevent oil leaking into water. 46CFR91.30-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 30 May 2019
Resolution: Bow thruster space was sealed up and completely secured.
Engineering › Sea-water System (primary cooling) › Valve
Issued 2 February 2016 Resolved
Ensure proper operations of vessel's propulsion system. Provide a class report detailing causative factors of the propulsion casualty and the completed repairs enacted. The discharge valve for the fwd circ pump is normally kept open, however it was in the closed position and therefore there was no water flow for the condenser, which ultimately caused the loss of propulsion. 33CFR160.111
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2016
Resolved 3 February 2016
Resolution: ABS attended vessel with Marine Inspectors and IO's. Class report issued, see docs.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 2 February 2016 Resolved
MATSON CORPORATION SHALL CONDUCT AN INTERNAL AUDIT OF THE SS MATSONIA'S SMS RELATED TO SEC 7 OF THE ISM CODE. SPECIFICALLY, THE COMPANY SHALL REVIEW PROCEDURES, PLANS AND INSTRUCTIONS FOR KEY SHIPBOARD OPERATIONS. ISM CODE PART A/7.
Condition: Invalid
Due 3 May 2016
Resolved 29 April 2016
Resolution: The company contracted KIM ESTES to conduct an Independent ISM Aiduit.

Casualty record · 12

9 June 2003Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2001502
14 January 2004Routine · role: Subject to Marine Inspection · activity 1984408
19 December 2005Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 5 injured · activity 2555856
25 September 2014Routine · role: Suspected Pollution Source · activity 4995200
3 February 2016Routine · role: Involved in a Marine Casualty · activity 5830409
28 July 2016Routine · role: Acknowledged Pollution Source · activity 5963323
26 December 2016Routine · role: Alleged Pollution Source · activity 6062471
20 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6340036
22 February 2018Routine · role: Involved in a Marine Casualty · activity 6362844
14 February 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6629007
21 February 2019Routine · role: Involved in a Marine Casualty · activity 6630595
23 January 2024Routine · role: Involved in a Marine Casualty · activity 7916062
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record