NATCHEZ

NATCHEZ is a 1975 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 2016, most recently in June 2026, along with 21 deficiencies and 2 casualty investigations between 2019 and 2022.

Records from 2016 to 2026. Most recent: inspection, 22 June 2026.

Built
1975
Last inspected
22 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WZC8491
Flag
UNITED STATES
Maury page id
psix-48316

Documentation record

Registered dimensions (L × B × D)236.0 ft × 40.0 ft × 7.9 ft
Registered tonnagegross 1,384 / net 1,384
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERGERON MACHINE SHOP,INC · BRAITHWAITE, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionSteam Reciprocating
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1384 - Regulatory (Subpart C or D), Gross Ton
1384 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

49 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; 1 vessel inspected with it, by name and date; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT FRANK Freight Barge · MISLE 219334 · 12 September 2019 · activity 6809808

Inspection history · 49

22 June 2026 SIP Inspection/Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8430516
13 January 2026 COI Inspection · Construction Oversight · SIP Inspection/Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8295421
16 December 2025 SIP Inspection/Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8286270
30 July 2025 SIP Inspection/Audit · MTSA Verification · COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8198278
21 May 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8140692
26 February 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8085472
6 November 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8031343
20 August 2024 In-Service Inspection · SIP Inspection/Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7961383
29 May 2024 SIP Inspection/Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7923840
4 April 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7889977
5 February 2024 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7679365
6 February 2023 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7632796
22 November 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7598348
27 May 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7459972
4 May 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7443621
4 May 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7443985
16 February 2022 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7397136
1 December 2021 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7360477
17 August 2021 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7289349
13 May 2021 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7196707
1 March 2021 Administrative Inspection · MTSA Verification · Examination of Repairs · Damage Survey · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7148108
17 February 2021 COI Inspection · SIP Inspection/Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7141599
4 December 2020 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7108178
31 August 2020 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7036435
28 May 2020 Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6962473
24 February 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6917554
27 January 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6896652
25 November 2019 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6862188
12 September 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6809808
22 August 2019 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6792259
15 May 2019 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6697105
13 February 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6791783
12 February 2019 Damage Survey · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6624997
22 January 2019 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6613586
30 November 2018 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6589886
27 August 2018 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6524526
29 May 2018 SIP Inspection/Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6423573
8 May 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6409893
4 January 2018 MTSA Verification · Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam · COI Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6332079
24 October 2017 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6294087
28 July 2017 SIP Inspection/Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226320
21 April 2017 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6146271
4 January 2017 Drydock Exam · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6065697
14 December 2016 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6058686
26 October 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6030025
19 October 2016 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6033112
21 July 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5949305
16 April 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5860203
5 January 2016 Examination of Repairs · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5791027

Deficiency record · 21

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2022 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter (H). On May 3, 2022, a fire occurred within the generator room resulting in significant damage to the machinery, electrical equipment, wiring, and structural fire protection within the surrounding area. Prior to repairs and the installation of new machinery and electrical equipment plans shall be provided to Marine Safety Center for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2023
Resolved 9 November 2023
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 February 2021 Resolved
The vessel is currently in a layup status for Boiler Repairs (Port Boiler) and Boiler Replace3ment on STBD Boiler along with some upper deck repairs. Prior to getting the vessel underway, complete the replacement of the STBD Boiler and repairs to the PORT Boiler. Complete all required inspection intervals to the satisfaction of the USCG Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 9 November 2023
Resolution: Completed
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 February 2021 Resolved
2.Currently all life rafts certificates have expired, vessel in maintenance period so prior to getting the vessel underway provide current life raft servicing reports.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2021
Resolved 9 November 2023
Resolution: Completed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 February 2021 Resolved
3. Current fire protection report from [name withheld] has deficiencies that require correction, Galley equipment will not shut down upon activation of the fire protection. Correct prior to operating the galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 9 November 2023
Resolution: Completed
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 February 2021 Resolved
4.No drills were witnessed today due to vessel in maintenance period, prior to carrying passengers, drills must be witnessed by the USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2021
Resolved 8 November 2023
Resolution: Completed
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 May 2020 Resolved
An abandon-ship drill and a fire drill, as described in 199.180, must be conducted on each passenger vessel at least weekly. Drills could not be conducted due to lack of crew on board resulting from local Covid-19 restrictions. Conduct drills IAW 46 CFR 199.180, and provide SIP documentation/associated logs to satisfaction of CG Marine Inspector prior to movement. 46 CFR 199.250(a) 46 CFR 199.180 46 CFR 78.17-50
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 June 2020
Resolution: Witnessed drills.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 May 2020 Resolved
If a survival craft is recovered by electric power, the electrical installation, including the electric power-operated boat winch, must meet the requirements in subchapter J of this chapter. If a survival craft is recovered by any means using power, including a portable power source, safety devices must be provided that automatically cut off the power before the davit arms or falls reach the stops in order to avoid overstressing the falls or davits, unless the motor is designed to prevent such overstressing. Provide proof of manufacturer-installed winch safety device, or install safety device & test to satisfaction of CG Marine Inspector prior to movement. 46 CFR 199.153(k)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 June 2020
Resolution: Witnessed installed safety devices.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 May 2020 Resolved
Each item of survival equipment with an expiration date must be replaced during the annual inspection if the expiration date has passed. Rescue boat wire bridles have no markings or documentation to prove maximum static load and servicing. Correct to satisfaction of CG Marine Inspector prior to movement. 46 CFR 199.190(f)(3)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 June 2020
Resolution: Verified inspection & testing of bridles.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 May 2020 Resolved
Items of equipment, which are in use on vessels, previously approved by the Commandant but not complying with the latest specification requirements may be continued in use so long as they are maintained in good and serviceable condition to the satisfaction of the Officer in Charge, Marine Inspection, until replacement is deemed necessary by such officer or as specified in the regulations. Hot water heater installation in crew galley/dishwashing service area has significant corrosion to electronics housing and vessel bottom. Replace hot water heater with new/serviceable unit or electrically isolate and tag-out system to satisfaction of CG Marine Inspector within 14 days.
Action required: 705 - Other - as specified
Resolved 10 June 2020
Resolution: Verified relief valve replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 February 2020 Resolved
Doors, other than those which are normally locked shall be of the self closing type against a 3 and 1/2 degree list. Upon arriving at the vessel there were issues with the port and starboard doors admidships on the 2nd deck and with the starboard foward door on the 2nd deck. These were rectified while inspectors were onboard. There is remains an issue with the portside door leading to the engine room. This issue needs to be corrected by the end of the next maintenance period.
Action required: 705 - Other - as specified
Due 19 February 2020
Resolved 9 November 2023
Resolution: Completed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 February 2020 Resolved
Ships position shall be continuously and automatically provided to all relevant radio communication equipment. The ship's position and MMSI number for the vessel were not currently displaying on either VHF reciever. (46 CFR 80.1083(f))
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2020
Resolved 19 February 2020
Resolution: Vessel has linked both VHF units to MMSI numbers and GPS units.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2018 Resolved
The vessel is not in compliance fully with 46CFR Part 16.230 (a)Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: under 16.230 (a)(3) which requires random drug testing for personnel who are "specifically assigned the duties of warning, mustering, assembling, assisting, or controlling the movement of passengers during emergencies." The definition of Crew Member is under 46CFR 16.105 under crew member (#2). Provide a proposal to make the vessel in compliance with these requirements. The proposal will need to be to our office by Friday 31 August 2018. Once proposal has been received and accepted the above will need to be complied with within 14 days.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 31 August 2018
Resolved 5 September 2018
Resolution: 33 additional stewards staff now in the drug testing program.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 May 2018 Resolved
Provide fire control plan for vessel to confirm boundary on portside of galley with opening in bulkhead.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 5 June 2018
Resolution: A-0 boundary restored at the portside galley bulkhead opening with installation of a closed window.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 May 2018 Resolved
Clearly mark CO2 pull station for paint locker aft of galley
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 6 June 2018
Resolution: CO2 station marked
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 29 May 2018 Resolved
Repair or replace reeefer aft of the galley. Remove all stowed equipment and goods on top of galley equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 6 June 2018
Resolution: Equipment properly stowed and reefer repaired.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 May 2018 Resolved
Relabel distribution board panel in galley with new equipment installed (ie. Reefer and hot box)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 6 June 2018
Resolution: Panel board labeled with new equipment.
Construction/Loadline › Structures › Deck Plating
Issued 26 February 2018 Resolved
Newly installed deck covering in galley does not have appropriate documentation showing it meets the requirements of NVIC 9-97 (CH-1) 2.2.1. Provide sufficient documnetation to attending MI.
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 6 March 2018
Resolution: Rcvd appropriate documentation flooring in galley. See narative for additional details.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 26 February 2018 Resolved
Several Lifejackets found with insufficient Retroreflective material. Correct to satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 5 March 2018
Resolution: Verified lifejackets had sufficient retroreflective material.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 February 2018 Resolved
Life Jacket stowage lockers rigged in such a way as to impede the release of Lifejackets and a portion of the cable broke during the course of our test. x2 stowage lockers still need to be re-rigged, required vessel to complete modifications to include new cables prior to 12Mar18.
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 5 March 2018
Resolution: New rigging installed and verified by attending MI.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 14 December 2016 Resolved
During response to small fire in storage locker. ID'd damage to electrical wiring (2 cables along beam) w/in space. Completely replace wiring w/ equivalent marine grade wiring to the damaged nonvital lighting system after properly locking/tagging system according to ship's safety procedures. Fix prior to use.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 14 December 2016
Resolution: Bluewater electric replaced 10 ft of braided CG approved Marine Grade wiring for the damaged overhead lighting in the storage locker to the satisfaction of CG Marine Inspector.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 December 2016 Resolved
Pump out bilges free of excess oily/water prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2016
Resolved 14 December 2016
Resolution: Bilge space w/in compartment pumped and cleaned to satisfaction of CG Marine Inspector.

Casualty record · 2

13 February 2019Routine · role: Involved in a Marine Casualty · activity 6791783
4 May 2022Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7443985
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.