MAURY USCG vessel records
← All vessels

JOHN JAMES AUDUBON

JOHN JAMES AUDUBON is a 1982 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in July 2022, along with 20 deficiencies — 2 with no resolution recorded — and 1 operational control, 1 with no removal date recorded.

Records from 2016 to 2022. Most recent: inspection, 8 July 2022.

Built
1982
Last inspected
8 July 2022
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 July 2022
Operational controls 1 with no removal date recorded
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE8037
Flag
UNITED STATES
Maury page id
psix-53693

Documentation record

Registered dimensions (L × B × D)102.6 ft × 32.0 ft × 8.9 ft
Registered tonnagegross 98 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLIBERTY ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

8 July 2022 Examination of Repairs · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7498178
4 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215433
22 July 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7013356
22 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6957793
13 May 2019 Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6683422
20 December 2018 Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601042
8 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6577213
25 May 2018 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6423361
26 April 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6436288
29 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6330260
23 February 2017 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6093647
15 June 2016 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5908573
6 April 2016 Internal Structural Exam · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5848506

Deficiency record · 20

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2020 Resolved
The owner or managing operator shall make a vessel available for dry dock examinations and internal structural examinations (ISE) to remain in compliance with this subchapter. Presently this vessel is overdue for dry dock and ISE examination and is restricted from carrying more than 6 passengers for hire. When ready for inspection email [email withheld]. 46 CFR 115.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2022
Resolution: Vessel is undergoing a hull/ise
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2020 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. On 25MAY2020 this vessel will be overdue for its annual inspection and is restricted from carrying more than 6 passengers for hire. When ready for inspection email [email withheld]. 46 CFR 115.500
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2019 Resolved
46 CFR 183.200(b) - No direct power shutoff for LED lights installed on 3rd deck. Install circuit breaker in pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 6 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 November 2018 No resolution recorded
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 May 2018 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is outside scope of annual inspection window and shall complete required annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: Vessel completed 1st annual inspection.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 23 February 2017 Resolved
1. Properly log garbage management in according log book.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Construction/Loadline › Penetrations › Gasket
Issued 23 February 2017 Resolved
3. Make engine room aft bulkhead water tight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 23 February 2017 Resolved
4. Replace wire on search light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 23 February 2017 Resolved
5. Remove or repair galley hood.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Resolution: Vsl o/o is in the process of removing the ducting from the galley. In the interim, the vsl no longer uses the ovens. They have changed the operation of the galley to only serve warmed items. Ovens are obsolete and are not used, neither is ducting.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 February 2017 Resolved
6. Install proper portable fire extinguisher bracket in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 February 2017 Resolved
7. Label distribution panel starboard side of main switch board.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 23 February 2017 Resolved
8. Repair starboard navigation light plug.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 June 2016 Resolved
Mount all battery boxes
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Vessel has fabricated new battery boxes and they are mounted properly.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 June 2016 Resolved
Mount controlller and secure wiring for A/C R/W Pump
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Controller and cable are properly mounted and secure
Engineering › Bilge Water Management System › Manifold
Issued 15 June 2016 Resolved
Label all bilge manifold valves
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: All bilge manifold valves labeled
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 15 June 2016 Resolved
Renew port M/E lagging
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Operator has installed lagging on port M/E lagging
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 June 2016 Resolved
Label breakers and controllers in E/R
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: All breakers and controllers in E/R are labeled
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 15 June 2016 Resolved
Renew O-rings for both reduction gear cross over pipes.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Operator has installed new o-rings on reduction gears
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 June 2016 Resolved
Install cover and properly wire j-box in stbd locker overhead
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Junction box properly covered and installed
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 June 2016 Resolved
Galley fire door does not close.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: fire doors to galley close properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.