JOHN JAMES AUDUBON

JOHN JAMES AUDUBON is a 1982 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1982, most recently in July 2022, along with 104 deficiencies — 2 with no resolution recorded — and 1 operational control, 1 with no removal date recorded.

Records from 1982 to 2022. Most recent: inspection, 8 July 2022.

Built
1982
Last inspected
8 July 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDE8037
Flag
UNITED STATES
368081190
Maury page id
psix-53693

Inspections, by type

…with no type recorded22
Years with a record 37 calendar years (1982–2022)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)102.6 ft × 32.0 ft × 8.9 ft
Registered tonnagegross 98 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLIBERTY ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7102MMSI 368081190 · active · voluntarily equipped · granted 13 March 2019, expires 13 March 2029
WDE8037MMSI 367400770 · expired · compulsorily equipped · granted 25 March 2009, cancelled 25 May 2019
WRA8883MMSI 366959980 · expired · compulsorily equipped · granted 21 November 2006, cancelled 8 April 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NATCHEZ Passenger (Inspected) · MISLE 48316 · 16 March 1997 · activity 9663COASTAL 101 Towing Vessel · MISLE 118774 · 16 March 1997 · activity 9663UNCLE GEORGE Towing Vessel · MISLE 129364 · 16 March 1997 · activity 9663REPLENISHER Commercial Fishing Vessel · MISLE 164272 · 16 March 1997 · activity 9663LOUISIANA ENTERPRISE Freight Barge · MISLE 232633 · 16 March 1997 · activity 9663

Inspection history · 82

8 July 2022 Examination of Repairs · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7498178
4 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215433
22 July 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7013356
22 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6957793
13 May 2019 Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6683422
20 December 2018 Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601042
8 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6577213
25 May 2018 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6423361
26 April 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6436288
29 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6330260
23 February 2017 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6093647
15 June 2016 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5908573
6 April 2016 Internal Structural Exam · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5848506
24 July 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5194370
14 December 2010 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3910357
16 March 2010 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3696095
19 March 2009 Deficiency Check · MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3436052
30 January 2008 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3140084
3 January 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3124073
12 December 2007 Hull Examination · In-Service Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3114271
19 November 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3100943
16 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3080921
6 March 2007 COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2882729
13 July 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2711310
19 July 2005 In-Service Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2431860
1 March 2005 MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2300770
19 July 2004 In-Service Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2137930
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963239
31 July 2003 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1854767
16 July 2002 Periodic Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1652452
27 February 2002 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1489684
26 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417338
25 July 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466154
16 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 231199
15 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453659
20 March 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 802234
31 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415033
11 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472908
12 May 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394962
9 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453473
4 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424542
14 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 64698
14 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 779556
16 March 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 9663
5 March 1997 Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454417
4 November 1996 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452215
20 March 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363544
5 December 1995 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442327
21 April 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1168633
21 March 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374233
22 April 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417636
22 March 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417621
23 April 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1137369
24 March 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358035
1 May 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 962614
24 April 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1268340
26 March 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258434
15 July 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 935434
6 June 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1237026
2 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906417
26 April 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999899
8 April 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234118
27 March 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906720
17 December 1990 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 907499
30 March 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218579
17 April 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340425
11 April 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 889388
31 March 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033855
3 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 886927
26 December 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347187
30 September 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044018
18 August 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347143
28 April 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343590
30 March 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990136
8 February 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327140
2 April 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023598
3 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306287
6 January 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300497
3 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291305
5 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281744
14 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970022
29 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970005

Deficiency record · 104

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2020 Resolved
The owner or managing operator shall make a vessel available for dry dock examinations and internal structural examinations (ISE) to remain in compliance with this subchapter. Presently this vessel is overdue for dry dock and ISE examination and is restricted from carrying more than 6 passengers for hire. When ready for inspection email [email withheld]. 46 CFR 115.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2022
Resolution: Vessel is undergoing a hull/ise
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2020 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. On 25MAY2020 this vessel will be overdue for its annual inspection and is restricted from carrying more than 6 passengers for hire. When ready for inspection email [email withheld]. 46 CFR 115.500
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2019 Resolved
46 CFR 183.200(b) - No direct power shutoff for LED lights installed on 3rd deck. Install circuit breaker in pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 6 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 November 2018 No resolution recorded
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 May 2018 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is outside scope of annual inspection window and shall complete required annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Resolution: Vessel completed 1st annual inspection.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 23 February 2017 Resolved
1. Properly log garbage management in according log book.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Construction/Loadline › Penetrations › Gasket
Issued 23 February 2017 Resolved
3. Make engine room aft bulkhead water tight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 23 February 2017 Resolved
4. Replace wire on search light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 23 February 2017 Resolved
5. Remove or repair galley hood.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Resolution: Vsl o/o is in the process of removing the ducting from the galley. In the interim, the vsl no longer uses the ovens. They have changed the operation of the galley to only serve warmed items. Ovens are obsolete and are not used, neither is ducting.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 February 2017 Resolved
6. Install proper portable fire extinguisher bracket in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 February 2017 Resolved
7. Label distribution panel starboard side of main switch board.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 23 February 2017 Resolved
8. Repair starboard navigation light plug.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 13 April 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 June 2016 Resolved
Mount all battery boxes
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Vessel has fabricated new battery boxes and they are mounted properly.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 June 2016 Resolved
Mount controlller and secure wiring for A/C R/W Pump
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Controller and cable are properly mounted and secure
Engineering › Bilge Water Management System › Manifold
Issued 15 June 2016 Resolved
Label all bilge manifold valves
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: All bilge manifold valves labeled
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 15 June 2016 Resolved
Renew port M/E lagging
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Operator has installed lagging on port M/E lagging
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 June 2016 Resolved
Label breakers and controllers in E/R
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: All breakers and controllers in E/R are labeled
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 15 June 2016 Resolved
Renew O-rings for both reduction gear cross over pipes.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Operator has installed new o-rings on reduction gears
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 June 2016 Resolved
Install cover and properly wire j-box in stbd locker overhead
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: Junction box properly covered and installed
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 June 2016 Resolved
Galley fire door does not close.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 22 June 2016
Resolution: fire doors to galley close properly.
Documentation › Certificates/Documents › FCC SSL
Issued 19 March 2009 Resolved
Provide a current Bridge to Bridge Radiotelephony Certificate. Vessel is restricted to operations less than 1000 feet from shore until a valid certificate is provided.
Due 19 April 2009
Resolved 21 May 2009
Resolution: VHF Bridge-to-Bridge Certificate provided.
Communications › Audible Communications › Bell
Issued 19 March 2009 Resolved
Provide a bell of sufficient size in accordance with the Inland Navigation Rules, 33 CFR 86.23.
Due 19 April 2009
Resolved 27 May 2009
Resolution: Bell and clapper provided.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 19 March 2009 Resolved
Make permanent repairs to the following broken windows in the passenger accommodations; Port side embarkation door located on the main deck, port side aft window IWO the supply locker on the main deck, and starboard side window in the aft door located on the second deck.
Due 19 April 2009
Resolved 21 May 2009
Resolution: All windows properly repaired.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 19 March 2009 Resolved
Properly mount door and provide a latching mechanism to secure the 32 VDC distribution panel located on the port side of the wheelhouse.
Due 19 April 2009
Resolved 21 May 2009
Resolution: Door properly mounted and secured.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 March 2009 Resolved
Remove dead cable located on the starboard side in the wheelhouse console and additional dead end wiring located above the steering console on the starboard side.
Due 19 April 2009
Resolved 27 May 2009
Resolution: Dead cable removed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 19 March 2009 Resolved
Properly repair and secure both covers on two galley distribution panels and provide latching mechanisms for both doors.
Due 19 April 2009
Resolved 27 May 2009
Resolution: Both covers corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 March 2009 Resolved
Replace all wasted lagging on the starboard side MDE.
Due 19 April 2009
Resolved 21 May 2009
Resolution: Lagging gear replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 March 2009 Resolved
Repair wasted battery box located in the engine room, port side aft.
Due 19 April 2009
Resolved 21 May 2009
Resolution: Battery boxes were renewed.
Engineering › Pressure Vessel › Marking and Stamping
Issued 19 March 2009 Resolved
Provide hydrostatic testing for the air receiver located in the starboard side engine room or provide proof that the UPV is not of sufficient size to be tested in accordance with 46 CFR 61.10. According to the COI, vessel's air receiver was over due for inspection on April 30, 2008 but vessel rep stated that UPV that required testing had been removed from the vessel.
Due 19 April 2009
Resolved 27 May 2009
Resolution: Air receiver tested on 27MAR2009. Pressure relief valve tested on this date and deficiency cleared.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 December 2007 Resolved
Secure overhead junction box in port side, aft companion space/heater room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 12 December 2007 Resolved
Secure black cable with wire ties on overhead in port side aft companion space/heater room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 12 December 2007 Resolved
Properly secure thermostat/microswitch on heating furnace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 12 December 2007 Resolved
Properly re-install or remove engine room stack exhaust fan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 December 2007 Resolved
Prove proper operation of engine room audible bilge alarm in pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 January 2008
Electrical › Electric Generation Source (service) › Panelboard
Issued 12 December 2007 Resolved
Properly blank off breaker panel space labeled (air-conditioner) located in engine room breaker panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Engineering › Fuel Oil Service System › Pump
Issued 12 December 2007 Resolved
Properly secure fuel oil leak located on port side MDE priming pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 12 December 2007 Resolved
Properly secure all loose wiring hanging in entry way to engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Engineering › Electric Propulsion System › Indicator Circuitry
Issued 12 December 2007 Resolved
Properly secure all loose hanging wires beneath indicator panel on port side MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Construction/Loadline › Structures › Trunk
Issued 12 December 2007 Resolved
Properly close holes located in stairway enclosure bulkhead on main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 December 2007 Resolved
Prove proper DAPI enrollement is apparent for entire crew.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 December 2007
Operations/Management › Drills/Instruction › Safety Orientation
Issued 12 December 2007 Resolved
Post station bill & conduct crew training.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 December 2007
Construction/Loadline › Structures › Superstructure
Issued 12 December 2007 Resolved
Remove or prove top deck canopy has passed a stability test IAW CG approval.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 31 December 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 December 2007 Resolved
Prove proper operation of all fire screen doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 December 2007 Resolved
Properly secure life jacket stowage boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 12 December 2007 Resolved
Replace wasted cleat of after deck on starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2007 Resolved
Make proper repairs to wasted hand rail located on after weather deck at bottom of stairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Documentation › Markings/Placards › Official Number (US)
Issued 12 December 2007 Resolved
Properly affix new homeport onto vessels transome.
Action required: 705 - Other - as specified
Resolved 31 December 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 December 2007 Resolved
Properly repair self-closing door leading to after weather deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 December 2007 Resolved
Properly repair self-closing door leading to starboard side weather deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2007 Resolved
Properly repair wasted handrail stancion located on second deck on port side aft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 December 2007 Resolved
Remove lock-type latches on PFD stowage box located a second after deck.
Action required: 705 - Other - as specified
Resolved 31 December 2007
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 12 December 2007 Resolved
Properly install or remove shore tie cable located on after weather deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Lifesaving › Rescue Boat › Markings
Issued 12 December 2007 Resolved
Replace retro-tape on rescue boat hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 December 2007 Resolved
Replace outlet box cover on starboard side amidships on second deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Engineering › Electric Propulsion System › Heating Element Circuitry
Issued 12 December 2007 Resolved
Properly wire block-heaters for both MDE's & genset.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 December 2007 Resolved
Install screen for starboard side supply fan in galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 December 2007 Resolved
Properly repair self-closing doors on main passenger deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Electrical › Electrical Distribution System (service) › Switch
Issued 12 December 2007 Resolved
Replace light switch cover plate located in aft steering void space companion way.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Electrical › Electric Generation Source (service) › Panelboard
Issued 12 December 2007 Resolved
Properly affix latch mechanism onto breaker panel box door located in aft steering void space companion way.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 December 2007
Construction/Loadline › Structures › Trunk
Issued 12 December 2007 Resolved
Seal stairwell bulkhead opening on starboard side of main passenger deck
Condition: Improper/Lack of Maintenance
Due 30 January 2008
Resolved 30 January 2008
Fire Fighting › Structural - A Class Divisions › Windows
Issued 12 December 2007 Resolved
Properly install remaining missing hardware & weather-tight seals on all bow windows that were sealed for transit.
Condition: Improper/Lack of Maintenance
Due 30 January 2008
Resolved 30 January 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 December 2007 Resolved
Provide DAPI employee enrollment addendum to USCG.
Condition: Unknown
Due 30 January 2008
Resolved 31 December 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 December 2007 Resolved
Remove water from battery boxes port side engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 December 2007 Resolved
Repair batter box port side aft, engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Engineering › Bilge Water Management System › Piping
Issued 12 December 2007 Resolved
Crop and renew wasted bilge piping in engine compartment as indicated by marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 12 December 2007 Resolved
Replace oiled breather hoses in way of port and starboard main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 December 2007 Resolved
Replace worn flexible hose in way of air conditioner water intake.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2007 Resolved
Crop and renew cracked/bent deck rail on bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 December 2007 Resolved
Properly splice and mount wiring for galley refers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 December 2007 Resolved
Weld cracked deck cribbing in galley as indicated by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 December 2007 Resolved
Conduct new to zone inspection and u/w drills in presence of a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2007
Electrical
Issued 21 March 1995 Resolved
PROVIDE ON BOARD APPROVED RUBBER MAT FOR ENGINE ROOM ELECTRICAL BUS.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Engineering
Issued 21 March 1995 Resolved
DEMONSTRATE PROPER OPERATION OF JACKET WATER TEMPERATURE GAUGE IN PILOT HOUSE.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Engineering
Issued 21 March 1995 Resolved
DEMONSTRATE PROPER OPERATION OF OVERSPEED TRIPS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Accommodation/Occupational Safety
Issued 22 March 1994 Resolved
Provide relief valves for both hot water heaters set to not more than 100PSI at 200 degrees F. IAW 46 CFR 176.25-32(b)(5)(v).
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Engineering
Issued 22 March 1994 Resolved
Make air receiver available for internal examination IAW 46 CFR 176.25- 30(b)(3).
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Engineering
Issued 22 March 1994 Resolved
Prove proper operation of air receiver relief valve IAW 46 CFR 176.25- 30(b)(2).
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Engineering
Issued 24 March 1993 Resolved
REMOVE TWIST CAPS FROM STBD MAIN DIESEL ENGINES.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Engineering
Issued 24 March 1993 Resolved
PROVIDE PLUGS FOR CONTAINMENT FOR FUEL AND LUBE OIL VENTS.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Engineering
Issued 24 March 1993 Resolved
PROVIDE LUBE OIL FLAME SCREEN ON VENT MAIN DECK.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Accommodation/Occupational Safety
Issued 24 March 1993 Resolved
LABLE GALLEY VENT HOOD FOAM SYSTEM PULL STATION AND VENT SHUT DOWN IN DINING ROOM.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 24 March 1993 Resolved
LABEL ENGINE ROOM VENT SHUTDOWNS.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 24 March 1993 Resolved
PROVE ALARM PANAL ON BRIDGE OPERABLE (LOW LUBE OIL)
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Documentation
Issued 26 March 1992 Resolved
PROVIDE DEVIATION TABLE FOR WHEELHOUSE MAGNETIC COMPASS.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Electrical
Issued 26 March 1992 Resolved
PROVE OPERATION OF EXIT EMERGENCY FIXED LIGHTING NEAR AFT AREA OF SECOND DECK.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Accommodation/Occupational Safety
Issued 26 March 1992 Resolved
REPLACE EXISTING WHITE PLASTIC TIE RAPS (SECURING THE UPPER DECK LINK FENCING) WITH A MORE DURABLE SECURING DEVICE (I.E., METAL BANDS)
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Fire Fighting
Issued 2 May 1991 Resolved
PROVIDE PLANS AND DETAILS OF INSTALLED GALLEY FIRE SUPPRESSION SYSTEM FOR GRILL AND DEEP FAT FRYER FOR APPROVAL.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 27 March 1991 Resolved
PROVIDE ONBOARD VESSEL AN ADDITIONAL 223 ADULT TYPE 1 PFD'S TO REPLACE THOSE REJECTED. (199 ADULT/36 CHILD). UNTIL SUCH TIME AS A CG MARINE INSPECTOR INSPECTS AND PASSES THE NEW OR RESTITCHED PFD'S, THE VESSEL TOTALPASSENGER COUNT MAY NOT EXCEED THE FOLLOWING: 365 ADULT/104 CHILDREN.
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Fire Fighting
Issued 27 March 1991 Resolved
PROVIDE AND POST OPERATING INSTRUCTIONS FOR THE FIXED DRY CHEMICAL EXTINGUISHING SYSTEM FOR THE GALLEY RANGE HOOD, ALSO ENSURE SYSTEM HAS BEENINSPECTED AND SERVICED WITHIN PAST YEAR
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Construction/Loadline
Issued 27 March 1991 Resolved
PLUG THROUGH BULKHEAD (WATERTIGHT) FITTINGS BETWEEN THE MACHINERY SPACE ANDGALLEY LOCATED ON THE PORT SIDE AT THE THROUGH CABLE RUN. (TOTAL OF 3 FITTINGS)
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Engineering
Issued 30 March 1990 Resolved
PROVE PROPER OPERATION OF THE STARBOARD MAIN ENGINE.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Engineering
Issued 30 March 1990 Resolved
WHILE THE STARBOARD MAIN ENGINE IS INOPERATIVE THE VESSEL IS NOT TO GET UNDERWAY WITH PASSENGERS UNLESS ASSISTED BY TUGS OF ADIQUATE SIZE AND SUFFICANT HORSEPOWER.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE 155 ADULT PFD'S. TOTAL PERSONS ALLOWED ON BOARD IS REDUCED BY 155 ADULTS UNTIL THIS ITEM IS CLEARED. 46 CFR 180.25-5 (A).
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
PROVIDE A HAND FIRE/BILGE PUMP. 46 CFR 181.10-5 (A) & (B)
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
REPAIR OR REPLACE GALLEY BLOWER. 46 CFR 183.01-15
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Engineering
Issued 31 March 1989 Resolved
RE-LAG THE STBD. MAIN ENGINE. 46 CFR 58.10-10 (A)
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 30 March 1988 Resolved
ESCAPE HATCHES FROM GALLEY AND ENG RM SHALL BE OPERABLE FROM EITHER SIDE. (REFERING TO 2ND MEANS OF ESCAPE) 46CFR171.124 & 46CFR177.15
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Construction/Loadline
Issued 30 March 1988 Resolved
PROVIDE APPROVED PLANS FOR CANOPY OVER UPPER MOST DECK. 46CFR176.20
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Construction/Loadline
Issued 30 March 1988 Resolved
PROVIDE APPROVED PLANS FOR NEW BOAT AND DAVITS LOCATED IN WAY OF THE STERN.(STRUCTURES & APPROVALS) 46CFR176.20
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Engineering
Issued 30 March 1988 Resolved
PROVIDE FIXED DRIP PAN UNDER FIXED OIL RESERVOIR IN ENG. RM. 46CFR176.25-50
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Engineering
Issued 30 March 1988 Resolved
PROVE PROPER OPERATION OF STBD MAIN ENG. OVER SPEED TRIP. 46CFR176.25-50
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Electrical
Issued 30 March 1988 Resolved
REPAIR WIRES AND CONNECTORS OF TWO PUMPS UNDER POTABLE WATER TANK IN GALLEY46CFR176.25-50
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 5 April 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL BAYOU LEAN LAFITTE DN646195
Condition: Unknown
Due 5 April 1984
Resolved 5 April 1984
Lifesaving
Issued 5 April 1984 Resolved
VESSEL MAY CARRY NO MORE THAN 300 TOTAL PERSONS. 300 ADULT TYPE PFD'S MUSTBE PROVIDED WITH 30 CHILDREN'S TYPE PFDS
Condition: Unknown
Due 5 April 1984
Resolved 5 April 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.