Records from 1986 to 2017. Most recent: inspection, 25 January 2017.
Inspection history · 113
25 January 2017
Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6077302
11 November 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6043129
10 April 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5865625
3 February 2016
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5809038
20 November 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5772264
16 April 2015
MTSA Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5103519
28 February 2015
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5077130
1 October 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4998195
14 July 2014
MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4921664
16 June 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4897065
17 July 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4396493
8 June 2012
Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4337538
12 December 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4212683
19 October 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4172278
4 October 2011
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4160865
30 August 2011
MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4130896
6 August 2011
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4106782
9 August 2010
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3819461
4 February 2010
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3675624
4 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3676102
1 June 2009
MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3492186
10 November 2008
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3365226
18 August 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3302346
26 June 2008
MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3252317
5 March 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3158830
26 October 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3087791
18 September 2007
Periodic Inspection · Hull Examination · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3029654
1 June 2006
Deficiency Check · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2667400
5 May 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2643510
25 March 2006
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2613675
17 December 2005
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2552895
13 October 2005
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2513864
29 August 2005
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2478498
2 August 2005
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2447849
3 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302716
30 August 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2181038
3 August 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2154400
2 August 2004
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2734661
27 July 2004
Plan Review (Other than "T")
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2146446
20 July 2004
MTSA/ISPS Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2140390
25 May 2004
Plan Review (Other than "T") · Internal Structural Exam · Hull Examination · MARPOL Annex I Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2077509
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1978825
12 August 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1876815
27 June 2003
Periodic Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1826775
12 June 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1833042
6 September 2002
Administrative Inspection · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1669968
5 September 2002
Liferaft Servicing
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1675072
4 September 2002
Hull Examination · Internal Structural Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1670544
20 May 2002
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1618458
21 September 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1074020
23 August 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1362400
9 November 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1055448
7 September 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1054177
25 November 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 98185
25 November 1999
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1051036
1 September 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375889
21 May 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386529
10 November 1998
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 805149
13 October 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1388630
27 August 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 797798
22 July 1998
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1450184
24 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664417
18 February 1998
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777255
10 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 100695
22 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 63982
22 January 1998
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 779187
18 November 1997
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1109088
7 November 1997
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1121527
9 October 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419839
19 June 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1368282
26 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 151666
16 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 9663
4 February 1997
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1104331
16 October 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398554
2 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 764086
12 May 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 196560
30 April 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 116450
30 April 1996
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1083019
22 March 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1077643
13 October 1995
COI Inspection · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1358944
15 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 161901
17 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 753353
8 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 196562
24 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 169922
22 September 1994
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1359983
18 November 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 845727
21 October 1993
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1133597
29 January 1993
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 830926
1 March 1992
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1317883
16 January 1992
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 947557
6 December 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1258027
24 August 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 935443
20 June 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 902833
17 May 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910431
13 May 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1219504
4 May 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223997
18 April 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 904786
17 January 1990
Examination of Repairs · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 904998
24 November 1989
Examination of Repairs · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900051
7 November 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1026810
7 November 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1333589
21 October 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1209532
20 September 1989
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1202031
11 April 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1199612
9 March 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 887912
8 February 1989
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1032049
4 March 1988
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1339476
24 August 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1338928
19 May 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 539560
24 April 1987
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1022044
26 June 1986
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 999746
22 May 1986
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1294724
24 April 1986
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1306695
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2017
No resolution recorded
Passed ISE date and Annual inspection window. Complete inspection per 46CFR31.10-15.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Penetrations › Gasket
Issued 3 February 2016
Resolved
Make necessary repairs to make cargo hold #4B weather-tight. Ensure that temporary repairs prevent a significant amount of water from entering the cargo hold. Submit a long-term repair proposal to CG for approval. Once complete, submit all class reports to CG. The deficiency will be cleared to the satisfaction of the attending CG Marine Inspector. 46 CFR 42.15-20
Action required: 705 - Other - as specified
Resolved 7 February 2016
Resolution: Hatch was repaired to the satisfaction of CG and ABS.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2015
No resolution recorded
A 3" crack was discovered on the stbd side of the #1 cargo hold. Water had seeped into the hold and onto the dry cargo.
Action required: 705 - Other - as specified
Engineering › Generator (propulsion-electric) › Charger
Issued 4 October 2011
Resolved
Prove proper operation of #1 Ship service generator. Generator failed to parallel to number #2 SSDG.
Action required: 705 - Other - as specified
Due 15 October 2011
Resolved 19 October 2011
Resolution: Operation proved to attending Marine Inspector
Construction/Loadline › Markings › Load Line Mark
Issued 30 August 2011
Resolved
Repaint load line deck line mark on stbd side in accordance w/ load line certificate.
Due 1 October 2011
Resolved 4 October 2011
Resolution: Deck line was repainted IAW load line certificate.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 August 2011
Resolved
Properly re-secure loose electrical wiring feeding the weather deck light on the port side at hatch 4A. Near fwd dog to gantry crane.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: loose electrical wiring was re-secured.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 30 August 2011
Resolved
Replace 4 damaged portable fire extinguishers as indicated to vessel representative.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Replaced 4 damaged portable fire extinguisher with new.
Lifesaving › Lifebuoys › Serviceable
Issued 30 August 2011
Resolved
Replace 4 worn life rings with new as indicatedto vessel representative.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Replaced 4 life rings with new.
Construction/Loadline › Structures › Door
Issued 30 August 2011
Resolved
Crop and renew watertight door on weather deck that leads to bow thruster access trunk.
Action required: 705 - Other - as specified
Due 20 July 2012
Resolved 24 April 2013
Resolution: Corrected.
Electrical › Lighting (service) › Conductor
Issued 30 August 2011
Resolved
Reweld loose wire conduit to the weather deck stbd at 3A/4A hatches.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Re-welded loose wire conduit to the weather deck.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 30 August 2011
Resolved
Prove proper operation of #1 SSDG reverse power relay to USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 15 October 2011
Resolved 19 October 2011
Resolution: Demonstrated properation of reverse power relay to USCG Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 August 2011
Resolved
Repair/replace stern bow and masthead navigation light stanchion on stern; stbd side.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Repaired stern bow and masthead.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 30 August 2011
Resolved
Repair or replace aft stbd side mooring line winch control box. Control box must be explosion proof.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Repaired aft stbd side mooring line winch control box.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 30 August 2011
Resolved
Repair areas of wasted cargo hatch gasket as indicated to vessel rep.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Repaired cargo hatch gasket in the area that was in question.
Engineering › Thrusters › Piping
Issued 30 August 2011
Resolved
Install missing pipe hangers for hydraulic piping lines; bow thruster access trunk on 1st deck.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Installed pipe hanger for hydraulic piping lines in bow thruster space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 August 2011
Resolved
Remove dead end wiring and terminate to their sources all exposed dead end wiring in way of ladder well in bow thruster access trunk.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Removed all dead end wiring in way of ladder well in bow thruster access space.
Fire Fighting › Combustible Materials › Insulation
Issued 30 August 2011
Resolved
Replace and renew broken insulation around exhaust muffler for bow thruster engine.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Replaced insulation around exhaust muffler in bow thruster space.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 30 August 2011
Resolved
Start Air reciever for bow thruster engine; replace cracked inspection cover w/ new and prover proper operation of relief valve in the presence of a USCG Marine Inspector
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2011
Resolution: Inspection cover was replaced and air receiver and relief valve was tested to 200lbs.
Construction/Loadline › Hull › Hull Plating
Issued 30 August 2011
Resolved
Make available for inspection the space in way of inset in hull plating on the port side exterior aft corner of the hull. Have ABS surveyor inspect surrounding internal area for damage. Complete to satisfaction of class surveyor and provide surveyor's findings to the USCG.
Action required: 705 - Other - as specified
Due 17 October 2011
Resolved 15 October 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 6 August 2011
Resolved
Vsl restricted from conducting cargo operations until repairs are made to the # 1 STBD cargo tank side shell, to the satisfaction of class and the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 7 August 2011
Resolution: Repairs made to side shell, #1 cargo STBD slope in way of ballast tk, and # 1 Cargo Aft corrugated bulkhead.
Construction/Loadline › Hull › Hull Plating
Issued 5 February 2010
Resolved
Make permanent repairs to damage in bow to the satisfaction of Class. Provide Class report to USCG Sector New Orleans prior to departure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 February 2010
Electrical › Lighting (service) › Conductor
Issued 1 June 2009
Resolved
Vessels NAV lights could not be tested due to there being no power availible to the vessel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2009
Engineering › Diesel Engine (auxiliary) › Block
Issued 1 June 2009
Resolved
Prove proper operation of both SSDG's and bow thruster prome mover overspeed trips, remote shutdowns, L/O and J/W shutdowns and remote fuel shut offs.
Condition: Unknown
Due 31 July 2009
Resolved 25 July 2009
Engineering › Compressed Air System (start air) › Valve
Issued 1 June 2009
Resolved
Provide documentation of test date and pressure for vessels (03) start and serive air receivers.
Condition: Unknown
Due 31 July 2009
Resolved 25 July 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 1 June 2009
Resolved
Prove proper operation of vessels ventilation shutdowns.
Condition: Unknown
Due 31 July 2009
Resolved 25 July 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 June 2008
Resolved
Provide original COD onboard vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 18 August 2008
Resolution: Vessel has original COD onboard.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 May 2006
Resolved
Repair the gasket for the exhaust vent closure to the machinery room.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: Installed new gaskets on machinery room vent covers.
Electrical › Electrical Distribution System (service) › Switch
Issued 5 May 2006
Resolved
Properly label the motor controller on the second landing of the bow thruster room.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: New labels installed
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 5 May 2006
Resolved
Properly label the breaker panel on the first landing in the bow thruster room with circuit directory.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: New label installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 May 2006
Resolved
Provide light covers as needed in all spaces, approx. (5) missing.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: All light covers installed as required.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 May 2006
Resolved
Provide a "T" handle for the reach rod to the bow thruster day tank shut off valve.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: New T handle provided.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 5 May 2006
Resolved
Provide an instruction placard/piping diagram at the local control station in the forward storeroom.
Due 23 June 2006
Resolved 28 June 2006
Resolution: Received documentary proof satisfying the requirement.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 May 2006
Resolved
Properly store all oxygen and acetylene bottles throughout the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2006
Resolved 7 June 2006
Resolution: Properly stored bottles as required.
Lifesaving › Lifebuoys › Quantity
Issued 5 May 2006
Resolved
Provide (6) total lifebuoys as discussed, located forward, amidships and aft on the port and stbd side.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: New life buoys installed as required.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 5 May 2006
Resolved
Adjust and prove proper operation of the over speed on the prime mover for the #2 generator.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: Witnessed proper operation of overspeed device.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 5 May 2006
Resolved
Locate and repair the ground in the lighting distribution panel on the main switchboard.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: Ground repaired.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 5 May 2006
Resolved
Properly label the fuel oil transfer hoses insuring the information on the test documents matches up with the hoses.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: Properly labeled hoses.
Stability › Watertight Integrity › General
Issued 5 May 2006
Resolved
Provide a watertight door on the second deck between the storeroom and the upper machinery space IWO centerline or provide proof of authorization for removal. There is some indication that there was a door in this location previously. This door also provides a vital fire boundary.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: Examined original plans, watertight door between storage space and engine space not original equipment.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 5 May 2006
Resolved
Provide proof of a valid plan and related reports and logs. Plan and records were on the tug and not available for inspection.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 7 June 2006
Resolution: Examined Ballast Water Management Plan, sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 25 March 2006
Resolved
Make temporary repairs to the #3 port side ballast tank inway of the #3 cargo hold, 5 1/2" X 15" approximately 12' aft of the fwd bulkhead and conduct a test to the satisfaction of class. Permanent repairs will be conducted during the drydock in Jul 07.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2006
Resolution: Temporary repaired and tested.
Construction/Loadline › Hull › Weld
Issued 17 December 2005
Resolved
Make area IWO of the #3 starboard Cargo Tank slope sheet/ballast tank available for inspection prior to conducting repairs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2005
Resolved 21 December 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 13 October 2005
Resolved
Repair faulty hydaulic system pressure gauges for all deck mooring equipment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 17 December 2005
Engineering › Thrusters › Motor
Issued 13 October 2005
Resolved
Replace bow thruster primemover RPM gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 17 December 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 13 October 2005
Resolved
Demonstrate proper operation of all alarms and shutdowns for deck mooring winches
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 17 December 2005
Pollution Prevention/Response › Response Equipment › Containers
Issued 2 August 2005
Resolved
Pollution spill kit box cover and coaming wasted and needs to be replaced. Also provide non-sparking equipment for the spill kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 29 August 2005
Resolution: Spill kit box cover and coaming was renewed.
Electrical › Electric Generation Source (service) › Conductor
Issued 2 August 2005
Resolved
Remove all dead ended electrical conductors from port and starboard ships service diesel generators
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 3 August 2005
Resolution: Conductors were satisfactory removed.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 2 August 2005
Resolved
Remove oily rags from the No. 2 generator containment area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 3 August 2005
Resolution: Oily rags were removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 August 2005
Resolved
Engine room starting batteries need a protective cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 29 August 2005
Resolution: A protective was installed.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 August 2005
Resolved
No. 2 generator electrical junction box cover is missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 29 August 2005
Resolution: The electrical junction box cover was installed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 August 2005
Resolved
Replace all electrical panels blank covers throughout the engineroom space ( including the replacement of the electrical panel door in the bow thruster space).
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 29 August 2005
Resolution: Blank covers and panel door were installed.
Construction/Loadline › Structures › Door
Issued 2 August 2005
Resolved
Replace wasted door and frame leading from engineroom to work shop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 29 August 2005
Resolution: Door and frame was removed to the satisfaction of the attending Marine Inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 August 2005
Resolved
Install a emergency source of light in way of the weight room for emergency egress.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 29 August 2005
Resolution: Emergency light was installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 August 2005
Resolved
Crop and renew salt water washdown piping in way of No. 4 cargo hatch starboard (Pipe is holed and has jubilee patch installed).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 29 August 2005
Resolution: Piping was replaced.
Construction/Loadline › Hull › Weld
Issued 2 August 2005
Resolved
Starboard railing stanchion welds in way of No. 1 cargo hold is fractured. Crop and renew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 29 August 2005
Resolution: Railing was renewed and properly welded.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 2 August 2005
Resolved
Starboard hydraulic winch cooler piping is leaking excessively. Make necessary repairs prior to use.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 13 October 2005
Resolution: Installed hydraulic cooler and satisfactorily tested
Engineering › Thrusters › Bearing
Issued 2 August 2005
Resolved
Bow thruster is inoperable. Gear box was removed for repairs. Prepare maneuvering proposal and timeline for repairs and installation of the box thruster gear box. (Received maneuvering proposal and timeline on 03 Aug 05).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 13 October 2005
Resolution: Witnessed satisfactory operational test of the bow thruster
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 2 August 2005
Resolved
Remove all oily substances from bow thruster containment ares.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 29 August 2005
Resolution: Oily substances removed from bow thruster containment.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 2 August 2005
Resolved
Replace or repair gantry crane coaming and hatch, starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 29 August 2005
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 August 2005
Resolved
Remove dead ended cable on the top of gantry crane.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 29 August 2005
Resolution: Resolved.
Electrical › Electric Generation Source (service) › Generator
Issued 2 August 2005
Resolved
Port and starboard generator shutdown devices and alarms are inoperable. Make necessary repairs and demonstrate proper operation of all shutdown devices and alarms indications prior to departure. (No Sail)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2005
Resolved 3 August 2005
Resolution: Port and starboard generator shutdowns and alarms indications were repaired and tested to satisfactory of the attending Marine Inspector.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 25 May 2004
Resolved
Make repairs or replace emergency escape hatch leading form the fire suppression room to the main deck.
Due 27 August 2004
Resolved 27 August 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 25 May 2004
Resolved
Make repairs or replace water tight hatch leading from the port side store room to the main deck.
Due 27 August 2004
Resolved 27 August 2004
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 25 May 2004
Resolved
Crop and renew the tank top and vent for the gantry crane fuel tank.
Due 27 July 2007
Resolved 2 August 2005
Resolution: A new tank was fabricated, installed and aprroved by ABS.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 25 May 2004
Resolved
Make repairs or replace motor controller for the bow thruster starting air compressor.
Due 27 August 2004
Resolved 27 August 2004
Deck/Cargo › Ballast › Vents
Issued 25 May 2004
Resolved
Properly label all vents on main deck.
Due 27 August 2004
Resolved 27 August 2004
Engineering › Bilge Water Management System › Piping
Issued 25 May 2004
Resolved
Remove soft patch from bilge piping for the bow thruster room bilge and make permanent repairs.
Due 27 August 2004
Resolved 25 May 2004
Engineering › Bilge Water Management System › Pump
Issued 25 May 2004
Resolved
Make permanent repairs to pumps and motors for the bilge systems for the lower machinery space and the bow thruster room as original.
Due 27 August 2004
Resolved 27 August 2004
Engineering › Bilge Water Management System › Piping
Issued 25 May 2004
Resolved
Provide and install standard discharge connection for the bilge systems for the lower machinery space and the bow thruster room.
Due 27 August 2004
Resolved 27 August 2004
Deck/Cargo › Ballast › Pumps
Issued 25 May 2004
Resolved
Provide and install guard over rotating machinery in the upper machinery space IWO ballast pumps.
Due 27 August 2004
Resolved 25 May 2004
Engineering › Fuel Oil Service System › Tank
Issued 25 May 2004
Resolved
Crop and renew fuel tank top for gantry crane.
Due 27 August 2004
Resolved 25 May 2004
Resolution: Entered in error.
Electrical › Electrical Distribution System (service)
Issued 25 June 2003
Resolved
Provide recepticles for freezers and other appliances in storeroom from breaker panel. No portable extension cords may be used or run through watertight doors. LEGACY COMPONENT DESC: Outlet Box
Due 17 August 2003
Resolved 12 August 2003
Resolution: HARD WIRED.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 June 2003
Resolved
Provide protective guards for bench grinder in machinery space. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Due 17 August 2003
Resolved 12 August 2003
Resolution: GRINDER REMOVED FROM SERVICE.
Electrical › Lighting (service)
Issued 25 June 2003
Resolved
Properly mount lighting fixture in port machinery space. LEGACY COMPONENT DESC: Lighting Fixture
Due 17 August 2003
Resolved 12 August 2003
Resolution: NEW FIXTURE
Electrical › Electrical Distribution System (service)
Issued 25 June 2003
Resolved
Rewire refrigerator to proper receptacle from circuit breaker in workout space. LEGACY COMPONENT DESC: Wiring
Due 17 August 2003
Resolved 12 August 2003
Resolution: REMOVED.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 25 June 2003
Resolved
Provide proper signage and paint siren red for halon system in port machinery space.
Due 17 August 2003
Resolved 12 August 2003
Electrical › Electrical Distribution System (service)
Issued 25 June 2003
Resolved
Provide blank in switchboard panel in JW position in generator room. LEGACY COMPONENT DESC: Distribution Panel Bus
Due 17 August 2003
Resolved 12 August 2003
Resolution: BLANK INSTALLED.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 25 June 2003
Resolved
Provide metal protective bowls for all Racor fuel filters on generators.
Due 17 August 2003
Resolved 12 August 2003
Resolution: INSTALLED
Construction/Loadline › Structures
Issued 25 June 2003
Resolved
Perform proper maintenance on all dogs on watertight door leading from STBD deck to STBD machinery space. LEGACY COMPONENT DESC: Door
Due 17 August 2003
Resolved 12 August 2003
Electrical › Lighting (service)
Issued 25 June 2003
Resolved
Provide proper working light and protective covering in generator room and bow thruster room. LEGACY COMPONENT DESC: Lighting Fixture
Due 17 August 2003
Resolved 12 August 2003
Resolution: NEW FIXTURES
Engineering › Generator (propulsion/auxiliary-electric)
Issued 25 June 2003
Resolved
Demonstrate proper operation of low lube oil shutdown and overspeed on #2 generator.
Due 17 August 2003
Resolved 12 August 2003
Fire Fighting › Miscellaneous Items
Issued 25 June 2003
Resolved
Clean label on fire control box in stairwell from STBD entry and label electrical box on adjacent blkd.
Due 17 August 2003
Resolved 12 August 2003
Construction/Loadline › Structures
Issued 25 June 2003
Resolved
Provide dog for WTD leading to generator space. LEGACY COMPONENT DESC: Door
Due 17 August 2003
Resolved 12 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 25 June 2003
Resolved
Repair handrailing on deck and top rail for deck stanchions on STBD side IWO #4 cargo hatch. LEGACY COMPONENT DESC: Deck Rail
Due 17 August 2003
Resolved 12 August 2003
Electrical › Electrical Distribution System (service)
Issued 25 June 2003
Resolved
Properly secure wires on all main deck decklights with wire tie downs. LEGACY COMPONENT DESC: Wiring
Due 17 August 2003
Resolved 12 August 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 25 June 2003
Resolved
Provide information for annual testing of transfer hose and gauge calibration LEGACY COMPONENT DESC: Transfer Hose
Due 17 August 2003
Resolved 12 August 2003
Electrical › Electrical Distribution System (service)
Issued 25 June 2003
Resolved
Prove that transformer in bow thruster space is in operable and power is disconnected at breaker. LEGACY COMPONENT DESC: Distribution Panel Bus
Due 17 August 2003
Resolved 12 August 2003
Resolution: DISCONNECTED
Electrical
Issued 23 August 2001
Resolved
PROVE TO LOCAL CG MARINE INSPECTOR THAT GENERATOR TWO LUBE OIL SHUTDOWN WORKS PROPERLY.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Electrical
Issued 23 August 2001
Resolved
PROVE TO LOCAL CG MARINE INSPECTOR THAT GENERATOR ONE SHUTDOWN WORKS PROPERLY.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Engineering
Issued 7 September 2000
Resolved
Unable to test Bow thruster engine shutdowns due to repairs on the reduction gear.
Condition: Unknown
Due 14 September 2001
Resolved 9 November 2000
Accommodation/Occupational Safety
Issued 7 September 2000
Resolved
Relief valve on top of generator room air receiver tested unsat.
Condition: Unknown
Due 7 October 2000
Resolved 14 September 2000
Fire Fighting
Issued 1 September 1999
Resolved
REPLACE HALON ALARM OUTSIDE STARBOARD MACHINERY ROOM.
Condition: Unknown
Due 1 November 1999
Resolved 2 September 1999
Engineering
Issued 1 September 1999
Resolved
REPAIR BLOWER SHUTDOWN ON NR 2 GENERATOR.
Condition: Unknown
Due 1 November 1999
Resolved 2 September 1999
Electrical
Issued 1 September 1999
Resolved
CLEAN BATTERY CONNECTION AND SECURE BATTERIES IN BATTERY BOX STBD MACHINERYROOM.
Condition: Unknown
Due 1 November 1999
Resolved 2 September 1999
Engineering
Issued 13 October 1998
Resolved
Test crane air receiver relief valves in presence of marine inspector.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Engineering
Issued 13 October 1998
Resolved
Test both generator overspeed shutdowns, Reverse Pwr Relays, low oil alarms, F/O remote stop and ventilation stops for generator space.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Engineering
Issued 13 October 1998
Resolved
Replace oil hoses (2) with piupe or tube from generator turbocharger oil drain return to engine block. Existing hoses are unsat for the applicationand pose a fire hazard.
Condition: Unknown
Due 13 October 1998
Resolved 14 October 1998
Lifesaving
Issued 13 October 1998
Resolved
Hydro test [name withheld] Pack cylinder.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Deck/Cargo
Issued 27 August 1998
Resolved
MAKE PERMANENT REPAIRS TO CARGO HOLD #3 ANY OTHER CARGO HOLD NECESSARY TO THE SLOPE SHEET HOLES NO LATER THAN NEXT DRYDOCKING.
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Deck/Cargo
Issued 22 July 1998
Resolved
MAKE PERMANENT REPAIRS TO CARGO TANK #3 AND ANY OTHER CARGO HOLD NECESSARY TO THE SLUMP SLOPE HOLES.
Condition: Unknown
Due 22 July 1998
Resolved 22 July 1998
Construction/Loadline
Issued 22 January 1998
Resolved
MAKE THE FOLLOWING REPAIRS TO FORE PEAK: CROP & RENEW 7 TRIPPED GUSSETS STBD SIDE BETWEEN #4 & #6 SIDE CORD, CROP & RENEW UPPER SIDE LONG BETWEEN #4 & #5 SIDE CORD, GOUGE & WELD TEAR IN FIRST DECK LONG AT #5 SIDE CORD. ALL REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE CG INSPECTOR.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Engineering
Issued 7 November 1997
Resolved
PROVE PROPER OPERATION OF THE HIGH JACKET WATER TEMPERATURE ALARM/SHUTDOWNSON BOTH GENERATORS.
Condition: Unknown
Due 18 November 1997
Resolved 18 November 1997
Engineering
Issued 9 October 1997
Resolved
REMOVE FUEL FILTER ASSEMBLY FROM BOW THRUSTER ENGINE AND REPLACE WITH APPROVED FUEL FILTER ASSEMBLY. (UL-168Y)
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Deck/Cargo
Issued 9 October 1997
Resolved
PROVE PROPER OPERATION OF BOW THRUSTER, ALARMS AND SAFETIES.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997
Resolved
SHORTEN ALL FLEX HOSES CONVEYING FUEL, LUBE OIL OR HYDRAULIC FLUID TO THE REQUIRED 30 INCHES OR LESS.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 9 October 1997
Resolved
REPLACE BROKEN INDICATOR LIGHT LENSE ON FUEL OIL TRANSFER PUMP CONTROLLER AND LABEL CONTROLLER.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Engineering
Issued 9 October 1997
Resolved
REPAIR LUBE OIL LEAK ON #1 GENERATOR GOVERNOR.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Engineering
Issued 9 October 1997
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING FOR BOTH GENERATORS: LOW LUBE OIL, HIGH WATER TEMPERATURE AND OVERSPEED VISUAL/AUDIBLE ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 9 October 1997
Resolved
REPAIR BROKEN LIGHT LENSE ON MAIN SWITCHBOARD SYNRCOSCOPE LIGHT.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Accommodation/Occupational Safety
Issued 9 October 1997
Resolved
REPAIR/REPLACE ALL RUSTED HAND RAILS AND REPAIR ALL LIFE LINE CABLES, REMOVING ALL FRAYED CABLES AND INSTALLING THE PROPER NUMBER OF CABLE CLAMPSON ALL LIFE LINES.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 9 October 1997
Resolved
REPLACE GASKETS ON FORWARD MACHINERY SPACE DOOR AND AFT MACHINERY SPACE VENT.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 9 October 1997
Resolved
INSTALL LABEL ON BREAKER PANEL IN BOW THRUSTER ROOM.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Deck/Cargo
Issued 13 October 1995
Resolved
PROVIDE SPECIFICS CONCERNING CAPACITY OF AIR RECEIVERS FOR DECK CRANES. IN LIEU OF THE ABOVE, CONDUCT HYDRO-STATIC TEST OF AIR RECEIVERS TO 125% OF MAWP. TEST TO BE WITNESSED BY CG INSPECTOR.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 21 October 1993
Resolved
Install nuts on numerous goose neck vent closures on main deck.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Accommodation/Occupational Safety
Issued 21 October 1993
Resolved
Prove operation of air receiver relief valves in bow thruster room and aft gantry crane.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Navigation
Issued 21 October 1993
Resolved
Renew starboard navigation light.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Accommodation/Occupational Safety
Issued 21 October 1993
Resolved
Replace wasted rail rear aft gantry crane control console.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Fire Fighting
Issued 21 October 1993
Resolved
Service halon system.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Repair incadescent light fixture on aft gantry crane rear the vertical ladder.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Install covers on all exposed light fixtures (incandescent & flourescent) in bow thrusters, generator and workshop spaces.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Construction/Loadline
Issued 21 October 1993
Resolved
Free-up dogs on door to bow thruster compartment.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Install nut on swing bolt for generator intake closure.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Provide rubber matting in front of generator switch board.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Remove jumper cables from battery bank in generator space.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Prove operation of both generator overspeed trips.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Repair incadescent light fixture on notch bulkhead in parts stowage.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Engineering
Issued 21 October 1993
Resolved
Install flame shields on racor filters on both generators.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 21 October 1993
Resolved
Remove or reconnect wire at junction box - port navigation light.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Engineering
Issued 21 October 1993
Resolved
Install sight glass guard on sight glass on fuel tank - aft pedestal crane.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Engineering
Issued 21 October 1993
Resolved
Install wrench to open deck plug to access forward emergency fuel shut off.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Engineering
Issued 21 October 1993
Resolved
Prove operation of both emergency fuel shut offs.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 16 January 1992
Resolved
CONDUCT OPERATIONAL TEST OF LOW LUBE OIL SHUTDOWN, OVERSPEED TRIP AND REVERSE CURRENT RELAYS ON NO. 1 & NO. 2 SERVICE GENERATORS.
Condition: Unknown
Due 28 February 1992
Resolved 9 March 1992
Construction/Loadline
Issued 16 January 1992
Resolved
PROVIDE MARKING OF NET TONNAGE ON MAIN BEAM.
Condition: Unknown
Due 28 February 1992
Resolved 9 March 1992
Deck/Cargo
Issued 16 January 1992
Resolved
PROVE PROPER OPERATION OF REACH ROD FOR REMOTE FUEL OIL SHUT-OFF VALVE, BOWTHRUSTER F/O TANK.
Condition: Unknown
Due 28 February 1992
Resolved 9 March 1992
Engineering
Issued 17 May 1991
Resolved
INSTALLATION OF DIESEL OIL SERVICE PUMP AND ITS MOTOR CONTROLLER SHALL BE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR. FUEL SHALL NOTBE TRANSFERRED ONTO BARGE UNTIL THIS ITEM IS COMPLETE OR WITHIN 7 DAYS.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Documentation
Issued 18 April 1991
Resolved
PROVIDE ABS OR USCG WELDER QUALIFICATION CERTIFICATES FOR PIPE WELDERS. FUEL SHALL NOT BE TRANSFERRED ONTO BARGE UNTIL COMPLETED.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 18 April 1991
Resolved
REPAIR RPM GAUGE ON PORT GENERATOR.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 18 April 1991
Resolved
PROVIDE COVER FOR GENERATOR SHORE POWER INDICATOR.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Deck/Cargo
Issued 18 April 1991
Resolved
PROVIDE FLAMESCREENS FOR BOTH GANTRY FUEL TANK VENTS.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Documentation
Issued 18 April 1991
Resolved
PROVIDE AN APPROVED REVISED DRAWING OF NOTCH MODIFICATIONS.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Documentation
Issued 18 April 1991
Resolved
PROVIDE DRAWINGS/SPECIFICATIONS OF DIESEL OIL SERVICE PUMP AND ITS MOTOR CONTROLLER TO THE MARINE SAFETY CENTER FOR APPROVAL. FUEL SHALL NOT BE TRANSFERRED ONTO BARGE UNTIL COMPLETED.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 18 April 1991
Resolved
REPAIR RPM GAUGE AND WATER TEMPERATURE GAUGE ON STARBOARD GENERATOR.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Engineering
Issued 7 November 1989
Resolved
OPEN ALL AIR RECEIVERS FOR COAST GUARD INSPECTION. NOTIFY THE LOCAL [name withheld].
Condition: Unknown
Due 7 November 1989
Resolved 7 November 1989
Electrical
Issued 9 March 1989
Resolved
REPLACE CABLE FROM SHORE TIE BOX TO SWITCHBOARD PRIOR TO USING CIRCUIT.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Engineering
Issued 8 February 1989
Resolved
REPLACE SO ELE. CABLE IN BOW THRUSTER ROOM WITH APPROVED CABLE.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Electrical
Issued 8 February 1989
Resolved
REMOVE STOP VALVE BETWEEN RELIEF VALVE AND AIR RECIVER ON GEN. AIR RECEIVERNAT. BOARD NO. A90243.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Engineering
Issued 8 February 1989
Resolved
REPLACE MISSING METAL SHIELD ON RACOR FUEL FILTER TO NO. 1 GENERATOR.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Electrical
Issued 8 February 1989
Resolved
REPAIR NO. 2 GENERATOR OVER SPEED TRIP.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Deck/Cargo
Issued 8 February 1989
Resolved
REPAIR AFT MACHINERY SPACE REMOTE VENT SHUT DOWN.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Electrical
Issued 24 April 1987
Resolved
REPAIR #1 GENERATOR REVERSE POWER RIP AND DEMONSTRATE ITS OPERATION TO THE SATISFACTION OF THE COGIZANT OCMI.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Documentation
Issued 22 May 1986
Resolved
PROVIDE ORIGINAL COPY OF THE FEDERAL POLLUTION LIABILITY CERTIFICATE ONBOARD THE VESSEL. (TE/CON WITH G-WFR VERIFIED THAT CERTIFICATE HAS BEEN APPLIED FOR AND GRANTED.) PROVIDE EVIDENCE OF SAME TO AN ATTENDING USCG INSPECTOR BY 23JUN86.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Construction/Loadline
Issued 22 May 1986
Resolved
REMOVE OILY RESIDUE FROM THE BILGES OF THE LOWER MACHINERY SPACE, STBD SKEGROOM BY 23JUN86.
Condition: Unknown
Due 22 May 1986
Resolved 22 May 1986
Lifesaving
Issued 24 April 1986
Resolved
PROVIDE ANNUAL SERVICE FOR SIX MAN INFLATABLE LIFERAFT.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Documentation
Issued 24 April 1986
Resolved
PROVIDE AND MAINTAIN ONBOARD THE ORIGINAL CERTIFICATE OF FINANCIAL RESPONS-IBILITY.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986