Inspection history · 86
1 February 2022
Type not recorded
No type recorded · Commandant (CG-INV) · Activity 7389151
29 October 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7377876
3 August 2021
Loadline Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7276491
8 September 2020
Load Line/Change of Employment
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7053562
12 April 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6662585
15 March 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6375011
24 February 2017
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6094150
18 February 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5817882
27 February 2015
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5076997
27 September 2014
MTSA Verification · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4994486
10 April 2014
COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4835725
5 October 2012
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4457598
14 March 2012
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4264553
25 January 2010
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3666279
19 March 2009
Cargo Tank Internal · Drydock Exam · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3436234
6 August 2008
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3290929
28 January 2008
Deficiency Check · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3137467
3 January 2008
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3124127
26 December 2007
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3121224
2 November 2006
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2816744
1 November 2006
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2812473
31 August 2006
Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2765163
11 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2621974
31 January 2006
COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2576458
28 December 2005
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2557062
4 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2451148
29 March 2005
Administrative Inspection
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2322085
28 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2321279
18 March 2005
MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2320143
10 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238729
21 May 2004
Internal Structural Exam · Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2060546
9 March 2004
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2022181
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1984231
17 April 2003
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1775580
15 April 2002
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1604986
11 April 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1607421
25 March 2002
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1495821
9 May 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 510142
9 May 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 523415
4 May 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 480251
4 May 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 517440
6 March 2001
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1366222
17 January 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 493042
8 June 2000
Examination of Repairs · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1444349
31 March 1999
Hull Examination · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1461113
6 July 1998
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1128067
6 November 1997
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1407999
10 June 1997
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1364186
20 February 1997
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1093948
22 May 1996
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1085096
14 June 1995
COI Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1191510
3 August 1994
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1180122
8 July 1994
Hull Examination · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 863730
8 June 1993
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 842827
24 May 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 78824
11 December 1992
Re-Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 830758
27 February 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 531174
1 August 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 445662
12 June 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 933530
12 June 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1210738
6 December 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 459053
22 June 1990
Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1242814
5 June 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 538143
5 June 1990
Permit to Proceed
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1211119
28 March 1990
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 924573
6 October 1989
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 472708
7 July 1989
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1194011
23 March 1989
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1033110
22 March 1989
Damage Survey · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1213692
2 November 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1205234
15 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030661
20 August 1987
Hull Examination · COI Inspection · Deficiency Check · MARPOL Annex II Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031352
8 June 1987
Examination of Repairs · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1335400
20 May 1987
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1334472
30 April 1987
Re-Inspection · Drydock Extension
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1017238
24 April 1987
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 513831
6 September 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 459639
18 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995588
23 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990321
21 September 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 537591
16 August 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 510609
22 January 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 300014
24 November 1984
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 486470
26 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973601
7 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967658
8 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276720
Construction/Loadline › Hull › Bottom Plating
Issued 27 September 2014
Resolved
Effect permanent repair to the 1/4" hole IWO #PWV #3bay approximately 6' under the double bottom in the bottom plate. A temporary repair is authorized in order to transit to North Bend Terminal to offload the current cargo of VGO. No further cargo operations are authorized.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 October 2014
Resolution: A 24" x 30" insert was made in the bottom plate.
Construction/Loadline › Hull › Bottom Plating
Issued 5 October 2012
Resolved
Pin hole leak in the #3 void approximately 10' aft from the forward starboard side hatch.
Action required: 705 - Other - as specified
Due 10 October 2012
Resolved 5 October 2012
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 5 October 2012
Resolved
Two fractures in the external framing at the top corner of the #2 port side cargo tank at frame 13 and 17.
Action required: 705 - Other - as specified
Due 10 October 2012
Resolved 5 October 2012
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 28 January 2008
Resolved
Control unit for thermal fluid heater needs to be mounted on the outside of the fuse panel box. Currently, the heater can not be tested without opening the door and exposing wiring to the weather. This configuration is not intrinsically safe, as required by 46 CFR 111.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 February 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 28 January 2008
Resolved
Emergency fuel pressure shut down switch on prime mover was jury rigged closed with wire.
Action required: 705 - Other - as specified
Resolved 1 February 2008
Deck/Cargo › Cargo Heating › General
Issued 28 January 2008
Resolved
Prove proper operation of all associated alarms for thermal fluid heaters.
Action required: 705 - Other - as specified
Resolved 1 February 2008
Construction/Loadline › Hull › Side Shell
Issued 3 January 2008
Resolved
PTP issued for repairs to #1 port void sideshell and bilge-knuckle. See narrative for this activity for complete details from damage survey, and PTP instructions/restrictions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 February 2008
Resolved 28 January 2008
Resolution: Approx 20'' x 12'' section of hull was replaced from bilge knuckle to the main deck and an insert in the #1 cargo tank approx 2'' x 6'' alongside the void. During testing, 2 small pinholes found, repaired and retested SAT. Vsl to be painted and refloate
Construction/Loadline › Hull › Bottom Plating
Issued 31 August 2006
Resolved
Repair as original upset bottom plate IWO port bilge knuckle from headlog aft to 60' and associated internals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2006
Deck/Cargo › Cargo Heating › General
Issued 6 May 2004
Resolved
TEST THERMAL FLUID HEATER AND EMERGENCY ENGINE SHUTDOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 31 January 2006
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 6 May 2004
Resolved
REPLACE CARGO TANK TOP PRIOR TO ANY CARGO OPERATIONS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 12 January 2006
Resolution: REPLACED TANK TOP.
Deck/Cargo › Cargo Heating
Issued 25 March 2002
Resolved
Repair generator and test thermal fluid heater, prior to its use, to the satisfaction of the attending marine inspector by 25APR02. LEGACY COMPONENT DESC: generator/thermal fluid heater
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 9 April 2002
Resolution: THERMAL FLUID HEATER''S GENERATOR WAS REPLACED. WITNESSED A COMPLETE TEST OF THE THERMAL FLUID HEATER BY THE COMPANY REP (WALT) SATISFACTORILY.
Construction/Loadline
Issued 20 May 1987
Resolved
AFFECT PERMANENT REPAIR ACCORDING TO GOOD MARINE PRACTICE TO DAMAGE IN STERN TRANSOM PORT SIDE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Construction/Loadline
Issued 30 April 1987
Resolved
MAKE PERMANENT REPAIR TO CRACK IN STBD BOW CORNER.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Deck/Cargo
Issued 30 April 1987
Resolved
TEST THERMAL FLUID HEATER SAFETIES IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Construction/Loadline
Issued 30 April 1987
Resolved
RENEW BROKEN/MISSING DOG ON STERN COMPARTMENT HATCH.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Deck/Cargo
Issued 23 February 1986
Resolved
PROVIDE OIL TRANSFER PROCEDURE FOR VESSEL PRIOR TO LOADING CARGO.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Deck/Cargo
Issued 23 February 1986
Resolved
PROVIDE BARGE PIPING DIAGRAM PRIOR TO LOADING ANY CARGO.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Deck/Cargo
Issued 23 February 1986
Resolved
REMOVE OIL/PRODUCT FROM #1 AND #2 WING VOID AND TEST CARGO TANK FOR LEAKS.
Condition: Unknown
Due 23 February 1986
Resolved 23 February 1986
Deck/Cargo
Issued 26 April 1984
Resolved
PROVIDE A VISIBLE INDICATOR AND MANUAL RESET FOR THE THERMAL FLUID HEATER AS REQUIRED BY 46 CFR 63.05-80 (B) AND (C).
Condition: Unknown
Due 26 April 1984
Resolved 26 April 1984
Unknown
Issued 26 April 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL LOGICON 412, DN563915.
Condition: Unknown
Due 26 April 1984
Resolved 26 April 1984