MAURY USCG vessel records
← All vessels

TAN'ERLIQ

TAN'ERLIQ is a 1999 towing vessel. The Coast Guard has recorded 77 inspections since 1999, most recently in March 2025, along with 46 deficiencies, 2 operational controls and 4 casualty investigations between 2006 and 2023.

Records from 1999 to 2025. Most recent: inspection, 20 March 2025.

Built
1999
Last inspected
20 March 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 20 March 2025
…with no type recorded17
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1999–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9178381
WDF2025
486001
Flag
UNITED STATES
Maury page id
psix-486001

Documentation record

Registered dimensions (L × B × D)139.7 ft × 48.0 ft × 20.0 ft
Registered tonnagegross 484 / net 329
ITC dimensions (L × B × D)139.7 ft × 48.0 ft × 20.0 ft
ITC tonnagegross 1,046 / net 313
BuilderDAKOTA CREEK IND INC · ANACORTES, WA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portVALDEZ, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it484 - Regulatory (Subpart C or D), Gross Ton
1046 - Convention (Subpart B), Gross Ton
329 - Regulatory (Subpart C or D), Net Ton
313 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PROTECTOR Towing Vessel · MISLE 444439 · 25 March 2021 · activity 7163530VISION Towing Vessel · MISLE 870758 · 25 March 2021 · activity 7163530COLUMBIA LAYNE Towing Vessel · MISLE 86455 · 15 January 2019 · activity 6626060SEABOLD Towing Vessel · MISLE 106974 · 15 January 2019 · activity 6626060LOST PT Freight Barge · MISLE 48676 · 30 April 2006 · activity 2638641

Inspection history · 77

20 March 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8095921
2 October 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8013215
11 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7897253
7 February 2024 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7863318
7 July 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7736091
27 March 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7659724
21 September 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7563950
9 February 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7393876
8 October 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7329312
28 June 2021 Drydock Exam · Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7238392
25 March 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7163530
24 March 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7162296
23 December 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7117458
25 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6987123
11 June 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6710541
26 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6649031
6 February 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6621050
15 January 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6626060
27 March 2018 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6379968
28 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6114056
7 March 2017 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6101110
14 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5909492
1 June 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5903487
2 March 2016 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5825663
19 January 2016 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5801271
5 May 2015 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5118552
23 February 2015 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5073379
25 November 2014 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5029875
2 June 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4876981
25 March 2014 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4823328
23 January 2014 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4788204
13 March 2013 Plan Review (Other than "T") · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4549409
28 September 2012 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4453295
9 April 2012 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4283130
29 March 2012 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4274775
7 November 2011 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4184262
17 June 2011 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4059935
27 April 2011 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3996736
29 March 2011 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3975053
29 March 2010 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3705020
4 March 2010 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3690538
22 February 2010 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3686736
22 July 2009 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3542839
3 July 2009 Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3522095
26 May 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3489573
22 April 2008 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3189891
16 July 2007 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3007526
14 June 2007 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2952398
27 October 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2809344
10 July 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2708645
18 May 2006 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2653601
30 April 2006 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2638641
4 April 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2615777
3 June 2005 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2378517
21 March 2005 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2316588
30 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2150443
2 July 2004 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2119179
26 May 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2133909
24 May 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2077112
7 May 2004 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2061852
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2015619
1 July 2003 Periodic Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1853067
4 August 2002 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1656470
5 July 2002 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1641523
17 April 2002 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1606307
16 March 2002 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1495018
25 February 2002 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1489178
12 February 2002 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1485995
2 June 2001 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 473625
24 May 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1412291
4 April 2001 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1448252
15 January 2001 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 61639
5 December 2000 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 450672
8 October 2000 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 436912
17 May 2000 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1361481
19 July 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1099850
11 May 1999 Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1375792

Deficiency record · 46

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2024 Resolved
Each switchboard must have a dead front. Each panelboard enclosure must meet UL 67, Standard for Panelboards. UL 67.29 - "Section 408.38 of the NEC requires all panelboards to be deadfront unless they are accessible only to qualified persons. UL requires such panelboards to be marked 'This panelboard shall be located where accessible only to qualified persons.'” Power panel 207 in engine room missing dead-front. 46 CFR 111.30-5(f) (Mid-J) 46 CFR 111.40-1 (Mid-J) UL 67. 29
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 11 April 2024
Resolution: MIs witnessed correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 February 2024 Resolved
Maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved. Exposed dead end wires on bridge from Seaclear not terminated in accordance with applicable system requirements to which plan review has been approved. 46 CFR 111.01-1(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2024
Resolved 11 April 2024
Resolution: MIs witnessed corrected wiring
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 February 2024 Resolved
The hull, superstructure, structural bulkheads, decks, and deckhouses shall be constructed of steel. Deckhouse is damaged and wasted in way of starboard exhaust stack. Rectify by next scheduled drydock. 46 CFR 92.07-10(a)
Action required: 705 - Other - as specified
Resolved 24 April 2024
Resolution: Rcvd photos indicating adequate repairs to the wastage.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 June 2020 Resolved
Electronic chart system not operable at time of inspection. Make system operable and demonstrate functionality.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2020
Resolved 13 July 2020
Resolution: Received photographic evidence of updated paper charts.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2020 Resolved
Emergency lighting in staircase from main deck to first deck not functioning. Repair emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 26 June 2020
Resolution: Emergency lighting system repaired and operational.
Engineering › Bilge Water Management System › Piping
Issued 27 March 2018 Resolved
Make permanaent repairs to soft patches on the black water vent in the Voith space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 2 April 2018
Lifesaving › Inflatable Liferafts › Float Free
Issued 7 March 2017 Resolved
Make permanent arrangement to enable life rafts to be float free. 46 CFR 199.130(c)(7)
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 April 2017
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 14 June 2016 Resolved
Make Stb MDE operational. 46CFR58.05
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2016
Resolved 15 June 2016
Communications › Alarms/Indicators › General Alarm
Issued 15 March 2016 Resolved
Make line locker general alarm operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 17 March 2016
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 19 January 2016 Resolved
Make stb MDE fully operational.
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 20 January 2016
Resolution: Tech rep performed maintenance on the engine and all SAT. Circuit breaker pannel came loose.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 February 2015 Resolved
Provide current Safety Radio Telephony Certificate
Action required: 705 - Other - as specified
Due 11 March 2015
Resolved 16 March 2015
Resolution: Vsl not required to have GMDSS does not need cert.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 25 March 2014 Resolved
Repair or remove open end wire on #2 SSDG
Due 1 April 2014
Resolved 27 April 2014
Resolution: Open end wire was removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 March 2013 Resolved
Cover/guard unprotected access to flywheel on both MDEs.
Due 1 April 2013
Resolved 1 April 2013
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 29 March 2012 Resolved
CHENG noticed a low temp cylinder, shut engine down and are replacing the cylinder
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2012
Resolved 29 March 2012
Resolution: See narrative for details.
Engineering › Lubricating Oil Service System › Hose
Issued 29 March 2011 Resolved
Install chaffing gear on the outboard side oil line off of the oil spinner (filter) on the starboard generator.
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 29 March 2011
Resolution: Installed chaffing gear.
Lifesaving › Lifebuoys › Serviceable
Issued 29 March 2011 Resolved
Renew or repair four liferings that are split from weather deterioration.
Action required: 705 - Other - as specified
Due 29 March 2011
Resolved 29 March 2011
Resolution: Replaced four defective liferings with new.
Engineering › Pressure Vessel › Marking and Stamping
Issued 29 March 2011 Resolved
Remove all paint from data plates on pressure vessels.
Action required: 705 - Other - as specified
Due 29 March 2011
Resolved 29 March 2011
Resolution: Paint removed from data plates.
Communications › Audible Communications › Bell
Issued 29 March 2011 Resolved
Install audible (General Alarm) bells/ringer in the forward workshop/storeroom and the line locker. Until installation is made personnel making access to the spaces will maintain communications with the watch via hand held radio.
Action required: 705 - Other - as specified
Due 30 April 2011
Resolved 27 April 2011
Resolution: Alarms installed and tested in the workshop and line locker areas.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 March 2010 Resolved
Renew non-metallic expansion joint on the starboard mde seawater coolant line.
Action required: 705 - Other - as specified
Due 4 April 2010
Resolved 29 March 2010
Resolution: Non-metalic expansion joint renewed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 March 2010 Resolved
Renew exhaust gasket on the starboard generator to repair exhaust leak off of turbo.
Action required: 705 - Other - as specified
Due 4 April 2010
Resolved 29 March 2010
Resolution: Gasket renewed, bolts were tightened.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 4 March 2010 Resolved
Install auto closure device on doors at the top of the ladder leading to pilot house.
Action required: 705 - Other - as specified
Due 4 April 2010
Resolved 29 March 2010
Resolution: Closures installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 3 July 2009 Resolved
Repair soft patch on MSD vent line
Action required: 705 - Other - as specified
Due 10 July 2009
Resolved 9 July 2009
Resolution: Soft patch repaired.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 3 July 2009 Resolved
Properly secure MSD in accordance with 33 CFR 159.7(b)
Action required: 705 - Other - as specified
Due 10 July 2009
Resolved 9 July 2009
Resolution: Lock placed in MSD overboard discharge.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 3 July 2009 Resolved
Provide simple operating procedures & properly label emergency steering system changeover
Action required: 705 - Other - as specified
Due 17 July 2009
Resolved 4 March 2010
Resolution: Instructions installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 July 2009 Resolved
Post schematic & complete instructions for operation of CO2 system
Action required: 705 - Other - as specified
Due 24 July 2009
Resolved 4 March 2010
Resolution: Sighted schematic.
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 July 2009 Resolved
Secure handles for 3 CO2 fuel shut off regulators & verify pressure is satisfactory
Action required: 705 - Other - as specified
Due 3 August 2009
Resolved 4 March 2010
Resolution: Handles secured.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 14 June 2007 Resolved
Provide fixed fire extinguishing system (CO2) or other approved system installed at the paint locker in accordance with 46 CFR 95.05-10(c), no later than 14 JULY 2007.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2007
Resolved 16 July 2007
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 June 2007 Resolved
Update fire control plans to reflect fixed fire extinguishing system at paint locker installation (port side foc'sle deck) in accordance with 46 CFR 97.36-1 no later than 14 JULY 2007.
Action required: 705 - Other - as specified
Due 14 July 2007
Resolved 16 July 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 July 2006 Resolved
Make proper repairs to two 4-inch cracks on #2 transverse baffle along inboard overhead girder in the starboard aft ballast tank.
Condition: Unknown
Due 26 July 2006
Resolved 19 July 2006
Resolution: V-ground, stop drilled and welded both cracks.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 4 April 2006 Resolved
Provide third party verification report that all machinery alarms and set points are set IAW approved automation test procedures.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 26 April 2006
Resolution: Setpoints reset.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 April 2006 Resolved
Remove or make electrical wiring correction on freezer in forward storage compartment.
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 14 April 2006
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 April 2006 Resolved
Remove all flammables and combustibles from forward storage compartment.
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 14 April 2006
Resolution: Corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 July 2004 Resolved
Bracket does not sufficiently support self-igniting light.
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 29 July 2004
Resolution: Repaired to the satisfaction of the attending CG marine inspector
Engineering › Non-conventional Propulsion/Steering
Issued 1 July 2003 Resolved
Provide proof of proper operation of the engineering automation system. LEGACY COMPONENT DESC: Automation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2003
Resolved 16 July 2003
Resolution: Proof provided.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 1 July 2003 Resolved
Provide proof of satisfactory test of the fixed fire detection system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2003
Resolved 16 July 2003
Resolution: Proof provided.
Lifesaving › Inflatable Liferafts
Issued 1 July 2003 Resolved
Place liferaft launching instructions in proper place. LEGACY COMPONENT DESC: Launching Instructions
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2003
Resolved 16 July 2003
Resolution: Liferaft launching instructions placed in proper place.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 July 2003 Resolved
Repair leaking fuel oil valve on port side in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2003
Resolved 16 July 2003
Resolution: Leak repaired.
Stability › Watertight Integrity
Issued 1 July 2003 Resolved
Adjust Watertight door leading from Stores to the Voith Room ensuring proper operation. LEGACY COMPONENT DESC: Water Tight Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2003
Resolved 16 July 2003
Resolution: Door adjusted.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 July 2002 Resolved
Demonstrate proper operation of OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 2 July 2004
Resolution: Repaired to the satisfaction of the attending CG marine inspector MISLE # 2119179
Lifesaving › Lifejacket/PFD (General)
Issued 2 July 2002 Resolved
Label all PFD stowage areas. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 July 2002
Operations/Management › Drills/Instruction › Fire
Issued 2 July 2002 Resolved
Demonstrate crew proficiency during drills. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 July 2004
Resolution: Resolved to the satisfaction of the attending CG Marine inspector see MISLE # 2119179
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 July 2002 Resolved
Demonstrate crew proficiency during drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 July 2004
Resolution: Resolved to the satisfaction of the attending CG Marine inspector see MISLE # 2119179
Construction/Loadline › Hull
Issued 23 February 2002 Resolved
Vessel gouged IWO #3 Port Fuel tank while tied abreast of another tug. Vessel inserted damaged area. Witnessed satisfactory NDT LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2002
Resolved 23 February 2002
Resolution: Vessel cropped and renewed. Witnessed satisfactory NDT.
Documentation
Issued 11 May 1999 Resolved
provide SOPEP
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Unknown
Issued 11 May 1999 Resolved
Vessel must sail with an additional licensed engineer to Valdez, AK on maiden voyage.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Documentation
Issued 11 May 1999 Resolved
provide periodic safety test procedures
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999

Casualty record · 4

30 April 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2638641
15 January 2019Routine · role: Involved in a Marine Investigation (non-casualty) · activity 6626060
23 December 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7117458
7 July 2023Routine · role: Involved in a Marine Casualty · activity 7736091
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.