Records from 1998 to 2026. Most recent: inspection, 21 July 2026.
Inspection history · 9
21 July 2026
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8434711
19 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8376545
12 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8371622
27 March 2025
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8100475
19 May 2016
DAPI Audit · Industry Initiated Exam · MTSA Verification · Administration · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5885386
26 August 2013
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4697521
2 May 2013
DAPI Audit · Administration · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4586289
18 November 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2824445
1 December 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 31313
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 July 2026
Resolved
Crew members must be familiar with their firefighting duties, and, specifically how to fight a fire in the engine room and else where on board the towing vessel. Crew members did not know how to fight a fire on the vessel. Provide adequate training to crew members so they are able to demonstrate ability to fight a fire aboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2026
Resolved 3 August 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. Excessive oil in bilge, clean and provide objective evidence to coast guard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2026
Resolution: Bilges have been cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. The starboard side engine was missing the fuel filter bowls.
Action required: 10 - Deficiency Rectified
Resolved 7 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Starboard side fuel piping near the generator was leaking contributing to the excessive fuel in the bilge. Identify leak and correct problem.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2026
Resolution: leak has been corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 March 2025
Resolved
A fixed fire pump must be capable of delivering water simultaneously from two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at 50 pounds per square inch (psi). Gauge reads 25psi when delivering water simultaneously from two hydrants.
Action required: 705 - Other - as specified
Resolved 28 May 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 27 March 2025
Resolved
Safety Orientation. Prior to getting underway for the first time on a particular towing vessel, each crew member must receive a safety orientation. Conduct and document training was completed to crew members, provide to a Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2026
Resolution: Vessel conducted safety orientation with whole crew. Provided documentation.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 27 March 2025
Resolved
Conduct satisfactory man overboard and fire drill in the presence of Marine Inspectors prior to recieving COI.
Action required: 705 - Other - as specified
Resolved 28 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2025
Resolved
a 40BC fire extinguisher must be located near the flammable and or combustible storage room or cabinet. There was no fire extinguisher near the flammable locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 27 March 2025
Resolved
The emergency duties and duty station must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. The emergency duties were not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 27 March 2025
Resolved
All crew members must be provided with health and safety information and training. This training must be documented. No training documentation available.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2025
Resolved
The fire hose must be fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. The port sie fire hose was missing a nozzle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 March 2025
Resolved
The master must ensure that all life saving equipment is properly maintained and ready for use at all times. Execess lifejackets were found onboard that did not have the proper markings or equipment attached.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Various Bilge sensors were inoperable, re-configure or replace faulty sensors, familiarize crew with test procedures and conduct satisfactory test of all installed bilge alarms, and to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 28 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2025
Resolved
Each cable and wire must be supported in order to avoid chafing or other damage. Metal ties observed fastening bot Gen set main power cables to supports. Remove all ties that may cause chaffing to cables and replace with support/retention devices that prevent chafing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 March 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Both main engines and generators missing insulation at the turbo chargers, install all required insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 March 2025
Resolved
Each towing vessel must perform the tests in Table 143.245(b). Alarm set points; Twice every 5 years, with no more than 3 years elapsing since last test. There is no record of any of the tests as required. Complete all of the tests and record IAW 143.245(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2026
Resolution: Alarm tests were conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2025
Resolved
If twist-on types of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Various uncovered junctions utilizing twist connectors found in the machinery space including the steering fluid low level alarm sensor. Install appropriate covers on all junction boxes as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025