Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 9.0 ft
Registered tonnagegross 94 / net 75
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 9 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Simplified, Gross Ton 75 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 20 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2025Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of towing vessel and safety of persons onboard under normal and emergency conditions.
Vessel experienced complete loss of propulsion and loss of power while transiting Houston Ship Channel. Vessel shall determine source of failure and rectify to the satisfaction of Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2025
Resolution: Air test completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2024Resolved
46 CFR 143.205
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Discovered exhaust leak on STBD engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2024
Resolution: Tech fixed exhaust leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2024Resolved
46 CFR 143.205
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Chaffing gear STBD engine needed for cables/hoses in bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2024
Resolution: Added Chafing gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2023Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
- Starboard Main exhaust leak at the turbo.
- Starboard Generator, oil leak and excessive oil build up on the winding.
- Starboard main engine mounting bolts and shims missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2023
Resolved 7 December 2023
Resolution: - Starboard Main exhaust leak at the turbo. Corrected, all sat.
- Starboard Generator, replaced gasket causing oil leak and cleaned winding. All Sat.
- Starboard main engine mounting bolts and shims installed and secured. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 January 2023Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants at a pressure of 50 psi, and be energized remotely from outside the engine room and at the pump. The discharge gauge on the fire pump was not operational and the local and remote means to energize the fire pump function intermittently.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2023
Resolved 20 January 2023
Resolution: Verified installation of pressure gauge installed on fire pump and observed satisfactory system test.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 January 2023Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials insofar as practicable. Accumulations of diesel fuel and lubricating oil were noted in the bilge below the starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2023
Resolved 20 January 2023
Resolution: Bilge under starboard main engine cleaned and free of diesel and lube oil
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 January 2023Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel. Excessive oil accumulation was noted on the air intake screen on both main engines, and excessive soot on the exhaust piping near the turbo charger on both main engines indicates the presence of an exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2023
Resolved 20 January 2023
Resolution: Air intakes on both main engines removed and cleaned. Lagging around turbo exhaust removed, verified no leak in exhaust piping, and new lagging installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2023Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Inspectors noted exposed, spliced wiring connected with twist-on type wire connectors and not properly enclosed in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2023
Resolved 20 January 2023
Resolution: Outlets installed and covers placed on all exposed wiring noted during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 January 2023Resolved
Each towing vessel must have a means to monitor rudder angle at each operating station. The aft operating station does not have a rudder angle indicator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 20 January 2023
Resolution: Verified ability to visibly monitor rudder angle from aft operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 19 January 2023Resolved
Each towing vessel operating in oceans and coastwise service must have an approved line throwing appliance, including an auxiliary line. The vessel does not have an auxiliary line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 24 February 2023
Resolution: Vessel provided documentation for auxiliary line that was placed on vessel.
Recorded names · 1
MISS LAURIE (2012–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.