Records from 1999 to 2024. Most recent: inspection, 10 January 2024.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portSAN PEDRO, CA
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 47
10 January 2024
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7865514
19 July 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6755038
26 June 2019
Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6726038
6 May 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6685419
15 October 2018
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6565890
12 December 2017
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6323222
2 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132495
26 October 2016
Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6030253
5 October 2016
Permit to Proceed · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6016875
30 September 2016
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6013060
8 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5857414
16 December 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5782833
2 March 2015
COI Inspection · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5075908
5 January 2015
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5045699
13 November 2014
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5022236
3 November 2014
Internal Structural Exam · Cargo Tank Internal · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5014975
29 October 2013
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4776654
8 December 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4250623
16 September 2010
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3850925
26 August 2010
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3837562
18 November 2008
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3563230
19 February 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3150261
13 October 2007
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3079516
17 August 2007
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3030731
17 January 2007
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2857268
2 November 2006
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2813071
2 November 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3067328
3 February 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2578612
15 December 2005
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2553710
14 December 2005
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2553515
20 May 2005
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2363701
25 April 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2564437
17 November 2004
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2241583
13 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2005974
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1966941
25 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1749162
30 November 2001
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1076419
2 September 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 448380
11 August 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 490293
11 November 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066944
1 November 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1055600
14 September 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 467053
10 September 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 54260
20 May 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 490418
16 January 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 448880
30 November 1999
Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451477
29 September 1999
Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463522
Construction/Loadline › Hull › Hull Plating
Issued 5 October 2016
Resolved
Make permanent repairs to the pinhole on the trunk top vapor space at centerline bulkhead of starboard tanks 3 & 4. Barge allowed to proceed to Enterpise Marine Shipyard in Houma, LA to make repairs. Owner Shall notify MSU Houma upon arrival.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2016
Resolution: Marine Inspector attended vessel 10/26/16 and verified repairs; all sat.
Construction/Loadline › Structures › Deck Plating
Issued 30 September 2016
Resolved
during TBSIP inspection a pin hole leak in the top of the #4 STBD cargo tank near the FWD bulkhead was found. A temp repair of epoxy was made and vessel is authorized to transit to Mobile, AL to offload and make permanent repairs.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 October 2016
Resolution: Cargo was offlaoded and vessel requested to sail back to its shipyard in Houma, LA to effect permanent repairs. SECTOR Mobile will allow this request and not allow the carriage of cargo, unitl MSU Houma is satisfied with the repairs.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 8 March 2016
Resolved
Water in drip pans
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2016
Resolution: Ship yard workers removed water and cleaned drip pans
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 8 March 2016
Resolved
Stbd pump engine shut down lever not operating properly
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2016
Resolution: Shut down lever freed and tested satisfactory
Deck/Cargo › Holds/Tanks › Ullage
Issued 16 December 2015
Resolved
Crew reported leak in # 1 void space. 5 inches of product reported in space. Make repairs to the satisfaction of the Coast Guard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2016
Resolution: Satisfactor air test was conducted to the satisfacton of attending U.S. Coast Guard Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 26 August 2010
Resolved
Make permanent repair to hull and deck plating on #2 stbd wing void. Damage is a result of an allison.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2010
Resolution: Witnessed sat dye pen. test of permanent repair. Vessel fit for route and service.
Construction/Loadline › Hull › Double Hull
Issued 15 December 2005
Resolved
Prior to conducting cargo operations, make permanent repairs to starboard side bow rake transitional knuckle and bow box internal framing to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2006