GERMAINE

GERMAINE is a 1978 offshore supply vessel. The Coast Guard has recorded 93 inspections since 1982, most recently in June 2026, along with 88 deficiencies — 1 with no resolution recorded —, 17 operational controls and 2 casualty investigations between 2011 and 2013.

Records from 1982 to 2026. Most recent: inspection, 25 June 2026.

Built
1978
Last inspected
25 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7914482 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CPB3108
Flag
BOLIVIA
366889590 (licence lapsed)
Maury page id
psix-49970

Inspections, by type

…with no type recorded36
Years with a record 32 calendar years (1982–2026)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it509 - Convention (Subpart B), Gross Ton
509 - Regulatory (Subpart C or D), Gross Ton
153 - Regulatory (Subpart C or D), Net Ton
509 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB3630MMSI 366889590 · expired · compulsorily equipped · granted 12 March 2013, cancelled 15 July 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BAYOU 14 J Mobile Offshore Drilling Unit · MISLE 51211 · 17 March 2002 · activity 1494686CHALLENGER Offshore Supply Vessel · MISLE 175250 · 11 February 2001 · activity 33218ROWAN PARIS Mobile Offshore Drilling Unit · MISLE 51961 · 19 August 1994 · activity 165855CAVALCADE Offshore Supply Vessel · MISLE 53308 · 21 December 1992 · activity 39627

Inspection history · 93

25 June 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8413786
26 January 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8301777
5 August 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8202693
7 May 2025 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8130346
28 April 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8121153
13 March 2025 PSC A · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8092530
9 March 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8088836
29 December 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8051805
20 August 2024 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7975434
16 August 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7972909
9 February 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7863295
19 October 2023 PSC A · Deficiency Check · PSC B · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7810961
5 September 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7784904
3 September 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7783758
25 July 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7750742
6 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7735029
26 June 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7720722
22 May 2023 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7686851
13 May 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7687276
25 April 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7675085
22 March 2023 Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7647044
9 March 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7648051
9 March 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7648239
30 January 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7628362
22 December 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7612191
25 November 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7598919
21 November 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7597870
30 September 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7571078
30 August 2022 PSC A
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7546971
25 January 2017 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6076766
17 January 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6072211
31 May 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5895040
14 February 2012 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4243520
26 January 2012 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4231308
30 July 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3557015
12 January 2009 Hull Examination · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3392519
22 December 2008 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3383686
3 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3188997
30 January 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2576035
12 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2332467
11 April 2005 In-Service Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2331232
27 January 2005 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2281642
18 February 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2008407
28 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1996391
6 January 2004 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1976701
24 November 2003 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1953292
16 April 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1774857
9 April 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1779652
29 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1736643
19 March 2002 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1599009
17 March 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1494686
20 November 2001 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1384904
11 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33218
4 January 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813854
29 July 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766802
16 July 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 192020
1 December 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438777
3 January 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785054
2 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783362
23 December 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455547
19 February 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460935
15 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 26950
3 January 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461677
23 December 1994 Re-Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454241
23 November 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 105919
15 September 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 867573
19 August 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 165855
25 January 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 654647
22 January 1994 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162732
20 January 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 46160
12 January 1994 Permit to Proceed
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 852652
6 January 1994 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385179
14 January 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450746
26 December 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138771
21 December 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 39627
21 December 1992 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423734
10 July 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 946705
27 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 647086
18 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 158434
29 January 1992 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260844
6 January 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 115175
23 December 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268657
8 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924316
11 January 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1305094
22 February 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915302
18 January 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898116
3 February 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1329489
15 December 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004227
28 September 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322249
21 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293072
28 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977527
3 November 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967867
7 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969697

Deficiency record · 88

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 May 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence in the below deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCO’s collected objective evidence that the vessel is not following SMS procedures 9.3. PSCO observed an inoperable fire pump at the port aft due to a broken impellor as well as a soft patch on the fire main that was not reported. Vessel could not produce evidence that the vessel or company notified their Recognized Organization or Flag Administration of the serious safety deficiencies. An external audit is required. 74SOLAS (20) IX/3.1 ISM Code Part A/10.1 30bc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 June 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 7 May 2025 Resolved
Fire extinguishing appliances shall be kept in good order and available for immediate use at all times during the voyage. PSCO observed an inoperable fire pump at the port aft due to a broken impellor as well as a soft patch on the fire main that was not reported. 60 SOLAS II/66 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 May 2025 Resolved
All the life-savings appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage, PSCO observed the rescue boat winch was non-operational which prevents the launching of the rescue boat. 60SOLAS III /4(c) 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2025
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 7 May 2025 Resolved
The siting and installation of accumulator batteries which provide a reserve source of energy shall be such as to ensure... reasonable safety. PSCOs observed water build up in battery case. 74SOLAS (20) IV/13.7.3 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2025
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 7 May 2025 Resolved
A reserve source... of energy shall be provided on every ship to supply radio installation for the purpose of conducting distress and safety radiocommunications...PSCO observed that the batteries used to supply GMDSS equipment were dead. 74SOLAS (20) IV/13.2 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 7 May 2025 Resolved
The Administration shall issue an appropriate minimum safe manning document or equivalent. PSCOs observed an expired Minimum Safe Manning Certificate. 74SOLAS (20) V/14.2.2 17bc
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 7 May 2025 Resolved
Contracting Governments undertake... to maintain... measures for the purpose of ensuring that, from the point of view of safety of life at sea, all ships shall be sufficiently and efficiently manned. PSCOs observed that no [name withheld] is currently assigned to the ship. 74SOLAS(20) V/14.1 17bc
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 7 May 2025 Resolved
The ring, lines and letters shall be painted white or yellow on dark background. They shall also be permanently marked on the sides of the ship to satisfaction of administration. PSCO’s observed certain letters were no longer white and two lines were not permanently welded. ICLL CH. 1 REG.8 40bc
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 May 2025
Resolved 19 August 2025
14 - Pollution Prevention › 145 - MARPOL Annex V › Other (MARPOL Annex V)
Issued 7 May 2025 Resolved
The entry for each discharge to a port reception facility shall include date and time of discharge and the estimated amount discharged for each category in cubic meters. PSCOs observed the entry to previous discharge of garbage to be inaccurate in accordance with the receipt. MARPOL Ch V/1-.3.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 March 2025 Resolved
All the life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. PSCO found the rescue boat winch was non-operational which means the rescue boat cannot be deployed SOLAS (1960) Ch III/Reg 4(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2025
Resolved 25 March 2025
Resolution: Resolved.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 20 August 2024 Resolved
Adequate information shall be provided to enable the equipment to be properly operated and maintained taking into account the recommendations of the organization. PSCO's observed no monthly EPIRB or SART test recorded in the vessel's GMDSS logbook in accordance with the guidelines establishedby the vessel's administration. 74SOLAS(2020Cons.)) CH. IV Reg 15.3
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 30 December 2024
Resolution: 29DEC24: Received documentation attesting to the rectification of 01 deficiencies for the GMDSS log book entries from an inspection that took place on 20AUG24
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 July 2024 Resolved
Control stations shall be separated from the remainder of the ship by "A" class bulkheads and decks. PSCO observed control station on bridge was not protected by "A" class boundary door, which allowed for the passage of flame and smoke.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2024
Resolution: Vessels class submitted report showing a Class A boundary door was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 July 2024 Resolved
The deck line... shall be marked amidships on each side of the ship. PSCO observed there was no deck line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 July 2024
Resolution: Class report with pictures showed painted deck line
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 January 2024 Resolved
A cargo ship shall be subject to a minimum of two inspections of the outside of the ship’s bottom during any five year period, except where regulations 14(e) or (f) is applicable. Where regulation 14(e) or (f) is applicable, this five year period may be extended to coincide with the extended period of validity of the certificate. In all cases, the interval between any two such inspections shall not exceed 36 months. The vessel’s last out of water drydock was 21DEC20, surpassing the 36-month interval. The period of validity was exceeded, rendering the Cargo Ship Safety Construction Certificate invalid. 74 SOLAS (20 Cons.) CH. 1/Reg. 10(a)(v)
Condition: Invalid
Action required: 30 - Ship detained
Due 2 February 2024
Resolved 9 February 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 5 January 2024 Resolved
Where air pipes to ballast and other tanks extend above the freeboard or superstructure decks, the exposed parts of the pipes shall be of substantial construction... PSCO observed excessive corrosion to multiple tank ventilation pipes on both port and starboard sides of vessel’s bulkhead deck, preventing them to be sealed and potentially permitting water intrusion, thus compromising the weathertight integrity of these structures. ICLL 66, Reg 20
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 2 February 2024
Resolved 9 February 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 January 2024 Resolved
Machinery space openings in position 1 or 2 shall be properly framed and efficiently enclosed by steel casings of ample strength... During the deck walk PSCOs identified 04 cluster areas of deck wastage with holes ranging from 1" to 2" located on the port side interior machinery space stairwell,in addition multiple areas of excessive corrosion and wastage on the knife-edges on 02 doors on the main deck leading down to the engine room, compromising their structural strength and weathertight integrity. ICLL 66, Reg 17
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 2 February 2024
Resolved 9 February 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 January 2024 Resolved
The annual survey shall include a general inspection of the structure, machinery and equipment referred to in paragraph (b)(i), to ensure that they have been maintained in accordance with regulation 11(a) and that they remain satisfactory for the service for which the ship is intended. PSCOs observed potential unknown water source in the steering compartment under concrete repair. Request a survey with ultrasonic shots to ensure the vessel’s structure, ballast tanks, and steering compartment are within permissible wastage specifications.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2024
Resolved 9 February 2024
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 5 January 2024 Resolved
Ships constructed before 1 July 1998 shall, where practicable, meet the requirements of paragraphs 1.1 and 1.2. No blind sector, caused by cargo, cargo gear or other obstructions outside the wheelhouse forward of the beam which obstructs the view of the sea surface as seen from the conning position shall exceed 10 degrees. PSCOs observed cargo stacked at a height impeding the crew’s visibility from the conning position. 74 SOLAS (20 Cons.) Ch. V/Reg 22
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2024
Resolved 9 February 2024
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 5 January 2024 Resolved
When the gangway overhangs the water so that there is danger of employees falling between the ship and the dock, a net or suitable protection shall be provided to prevent employees from receiving serious injury from falls to a lower level. PSCOs observed the net under the gangway did not extend out to cover the space between the ship and the dock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2024
Resolved 9 February 2024
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 May 2023 Resolved
There shall be provided between the radio telegraph operating room and the bridge and one other place, if any, from which the ship is navigated, an efficient two-way system for calling and voice communication which shall be independent of the main communication system on the ship. The secondary, independent means of communication between the bridge and engine room, which is where the ship can be navigated, is inoperable. Solas (60) IV/8(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 6 July 2023
Resolution: "The system had a bad/faulty cable. The secondary indpeendent mean (telephone) was repaired and tested with satisfactory results to survey satisfaction." - Togo (Flag Surveyor
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 22 March 2023 Resolved
Every ship of 100 Gross tonnage and above, and every ship which is certified to carry 15 or more persons and fixed or floating platforms shall carry a garbage management plan which they shall follow. This plan shall provide written procedures for minimizing, collecting, storing, processing. And disposing of garbage including the use of the equipment on board. It shall also designate the person or persons in charge of carrying out the plan. PSCO’s observed garbage management plan on board that did not record food garbage, the plan did not state the vessel specific process for minimizing, collecting, storing, and processing garbage. MARPOL 17 V/10.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 April 2023
Resolution: Garbage Management Plan that was approved has been reinstated with the proper procedures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
The owner, master, or person in charge of each vessel underway shall ensure that the vessel anchors are ready for letting go. Vessel anchor is not suitable for letting based on the size of the vessel. 33CFR164.11 (o)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2023
Resolution: Vessel anchor has been replaced by a suitable anchor and installed.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Diesel engine relating to air pollution control
Issued 22 March 2023 Resolved
The bunker delivery shall be kept on board the ship in such a place as to be readily available for inspection at all reasonable times. It shall be retained for a period of three years after the fuel oil has been delivered onboard. PSCO’s discovered crew was missing bunker delivery notes from a few select fuel recipients. MARPOL 17 CONS. V/6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2023
Resolution: Bunkery delivery notes were satisfactorily produced upon request.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 March 2023 Resolved
Accumulator batteries shall be suitably housed and compartments used primarily for their accommodation shall be properly constructed and efficiently ventilated. PSCO’s observed a battery unhoused in between the generators causing a hazard in the engine room. SOLAS 60 II/27(a)(vii)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2023
Resolution: Battery has been placed in a new housing. No longer causing a hazard to the crew.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 March 2023 Resolved
All exposed metal parts of electrical machines or equipment which are not intended to be “live”. But are liable to become “live” under fault conditions shall be earthed (grounded): and all electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. PSCO’s discovered a panel with multiple grounded issues causing unknown electrical issues onboard for the crew. SOLAS 60 II/27.1(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2023
Resolution: Electrical panel has been restored to a staisfactory condition.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO’s found a generator missing it’s guard creating a hazard to the crew. 74 SOLAS (20) I/11(a)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2023
Resolution: New guard has been installed satisfactorily
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 March 2023 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background… Load line lettering for tropical, summer, winter, tropical fresh was not painted on the vessel. ICLL (66) Annex I/8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2023
Resolved 25 April 2023
Resolution: Load lines have been satisfactorily painted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
A ship, except a ship of less than 26ft must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space… No Oil Discharge placard was found in any machinery space. 33CFR 155.450 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2023
Resolved 25 April 2023
Resolution: Oil discharge placards have been suitably placed in the Engine Room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 March 2023 Resolved
Satisfactory means, permanently attached, shall be provided for closing the openings of the air pipes. PSCOs observed every air pipe on the freeboard deck to not be equipped with a permanently attached closing/opening mechanism for the vents. ICLL (66) Annex I/20
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2023
Resolution: Flapper closing mechanism have been installed on the air vents at the deck.
Engineering › Freshwater System (air cooling) › Piping
Issued 25 January 2017 Resolved
The piping systems installed on all vessels shall be safe and efficient for operation. Soft patch discovred of chill water pipe in port deck locker. Fix with proper permenant repairs to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 3 February 2017
Resolution: Vessel made proper permenant repairs to piping.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 January 2017 No resolution recorded
Vessel has a USCG approved resonse plant. Crew has not been follwing any plan requirements for training, drills, or QI notifications. Provide proof of follwing of all plan requirements to the satisfaction of USCG. Deficiency will remain outstanding until next annual inspection to confirm crew has followed all plan requirements.
Action required: 705 - Other - as specified
Lifesaving › Lifebuoys › Stowage
Issued 25 January 2017 Resolved
Before the vessel leaves port and at all times while underway all lifesaving appliances shall be ready for immediate use. STBD aft ring lifebuoy bracket is broken.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 3 February 2017
Resolution: Vessel made appropriate repairs.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 May 2016 Resolved
Breaker at the bottom of the stairs by messdeck for the dryer not labeled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: Labeled before completion of inspection.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 May 2016 Resolved
02 electric panels in passageway going to E/R has circuits that are not properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Circuits labeled
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 31 May 2016 Resolved
Door indicators not proper mounted both sides of the engine room and to weather.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2016
Resolved 1 June 2016
Resolution: Witnessed satisfactory test of all WTD indicators.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 31 May 2016 Resolved
Reset button on STBD MDE aft missing retaining nut.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: Retaining nut replaced prior to completion of inspection.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 31 May 2016 Resolved
Panel zones not labeled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: Heat detecters tested identified Zone 1 is for the E/R, labeled installed. The E/R is the only location which is monitored by the system
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 May 2016 Resolved
NEW ORLEANS is marked as the hailing port on the Stern. The Hailing port on the COD indicates LAROSE. The Vessel representative is working with NVDC to change the COD to reflect NEW ORLEANS. Vessel rep submitted changes, which were returned by NVDC. Requested more time. Changed due date to 15 JUL 2016.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 22 November 2016
Resolution: Verified information was corrected.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 31 May 2016 Resolved
No automation tests completed for 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 6 June 2016
Resolution: Received Automation report.
Documentation › Logs/Records › Logbook (official)
Issued 31 May 2016 Resolved
EPIRB tests not recorded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: Witnessed EPIRB test and logging.
Navigation › Piloting/Steering › Notices to Navigation
Issued 31 May 2016 Resolved
No NAVTEX installed on vessel. NAVTEX shipped vessel representative requested more time. Changed due date 15JUL2016.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 6 July 2016
Resolution: NAVTEX installed on vessel tested sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 May 2016 Resolved
Missing blanks in panel board in refrigerator compressor room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Attended vessel ensured blanks properly installed.
Engineering › Steering Gear System › Feedback Unit
Issued 31 May 2016 Resolved
7 deg difference between the Starboard and Port rudder angle indicator when using #2 steering pump.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Attended vessel verified proper operation
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 May 2016 Resolved
Failed to complete COI annual inspection within three months after the COI anniversary date 15FEB2016. 19MAY2016 was the date the vessel stopped operations, 15FEB2016 was the drop dead date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2016
Resolved 31 May 2016
Resolution: Completed COI inspection
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 14 February 2012 Resolved
Washing machine mounted in berthing area with drain hose run across the floor into the head and draining into the shower.
Due 14 March 2012
Resolved 15 March 2012
Resolution: Mounted washing machine outside the berthing space and hard-piped the drain into ships grey water system.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 February 2012 Resolved
Stand up freezer mounted in passageway in mess room obstructing the exit from the space.
Due 14 March 2012
Resolved 15 February 2012
Resolution: Removed freezer
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 February 2012 Resolved
Two chest freezers mounted in the 01 deck passageway obstructing the exit.
Due 15 March 2012
Resolved 15 February 2012
Resolution: Moved freezers to allow enough space in the passageway.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 14 February 2012 Resolved
Galley stove not mounted and oven door missing latch. No burner guards for stove top.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2012
Resolved 15 February 2012
Resolution: Secured stove to bulkhead and installed door latches and burner guards.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 14 February 2012 Resolved
Television in mess deck lounge area not secured to shelf
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2012
Resolved 15 February 2012
Resolution: Secured TV with a cargo strap.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 14 February 2012 Resolved
Fuel oil transfer pump leaking fuel.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2012
Resolved 15 February 2012
Resolution: Replaced pump flange gaskets.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 February 2012 Resolved
Excessive boxes and other materials stored on the deck in the engine room passageway creating a tripping and fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2012
Resolved 15 February 2012
Resolution: Stowed all gear in the engine room passageway.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 February 2012 Resolved
PFD storage locker and stowage space in berthing not labeled.
Due 14 March 2012
Resolved 15 February 2012
Resolution: Labeled all PFD stowage areas.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 14 February 2012 Resolved
Engine room stack vent closures not labeled.
Due 14 March 2012
Resolved 15 February 2012
Resolution: Labeled vent closures.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 14 February 2012 Resolved
Sight glasses on the fuel oil service tanks do not have guards installed.
Due 14 March 2012
Resolved 15 February 2012
Resolution: Installed guards on sight glasses.
Engineering › Steering Gear System › Rudder Stock
Issued 14 February 2012 Resolved
Stbd rudder shaft packing leaking excessively.
Due 14 March 2012
Resolved 15 February 2012
Resolution: Tightened packing
Fire Fighting › Means of Escape › Emergency Lighting
Issued 14 February 2012 Resolved
Emergency light in engine room passageway not working and e-light to engine room escape hatch dim.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2012
Resolved 15 February 2012
Resolution: Replaced bulb in passageway light and replaced batteries in escape hatch light.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 February 2012 Resolved
Crew was new to the vessel and not used to working together. All three drills were unsatisfactory and objectives could not be met. Provided feedback to the crew and rescheduled drills for the following day.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2012
Resolved 15 February 2012
Resolution: All drills were conducted with satisfactory results.
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 29 January 2009 Resolved
Label General Alarm Switch on Bridge
Due 8 February 2009
Resolved 2 February 2009
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 29 January 2009 Resolved
Replace sight glass for lube oil storage tank with non plastic sight guage
Due 8 February 2009
Resolved 2 February 2009
Communications › Public Address System › Amplifier
Issued 29 January 2009 Resolved
Install PA on Emegency Power
Due 8 February 2009
Resolved 2 February 2009
Accommodation/Occupational Safety › Ventilation › General
Issued 29 January 2009 Resolved
Label ventillation shut downs and Emergency Fuel Shut off with proper identificaiton.
Due 8 February 2009
Resolved 2 February 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 January 2009 Resolved
Provide rescue harness that fits crewmembers for Rescue platform station.
Due 8 February 2009
Resolved 2 February 2009
Documentation › Logs/Records › Logbook (official)
Issued 30 January 2006 Resolved
Log arrival and departure checks in masters log
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2006
Resolved 31 January 2006
Resolution: Corrected deficiency with logs.
Documentation › Logs/Records › Logbook (official)
Issued 30 January 2006 Resolved
Log monthly EPIRB checks
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2006
Resolved 31 January 2006
Resolution: Corrected deficiency
Electrical › Electrical Distribution System (service) › Junction Box
Issued 30 January 2006 Resolved
Provide and install a J-Box for the wire connections in rudder compartment.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2006
Resolved 31 January 2006
Resolution: CORRECTED ABOVE DEFICIENCY
Lifesaving › Launching Appliances › Release Mechanism
Issued 30 January 2006 Resolved
Configure life rafts for quick release.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2006
Resolved 31 January 2006
Resolution: CORRECTED DEFICIENCIY
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 30 January 2006 Resolved
Properly configure starboard life raft release or renew.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2006
Resolved 31 January 2006
Resolution: CORRECTED DEFICIENCY
Engineering › Pressure Vessel › Shell Plate
Issued 30 January 2006 Resolved
U/T AND HYDRO OR RENEW ENGINE ROOM LOWER AIR RECEIVER TANK WITH APPROVED AIR RECEIVER.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2006
Resolved 31 January 2006
Resolution: INSTALLED NEW APPROVED PRESSURE VSL.
Construction/Loadline › Structures › Machinery Space Opening
Issued 30 January 2006 Resolved
REPAIR WATER TIGHT DOORS AS MARKED
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2006
Resolved 31 January 2006
Resolution: CORRECTED WTD''S
Lifesaving › Inflatable Liferafts › Markings
Issued 30 January 2006 Resolved
RE STENCIL BOTH LIFERAFTS STATIONS
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2006
Resolved 31 January 2006
Resolution: STENCILED LIFE RAFT STATIONS
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 30 January 2006 Resolved
Repair starboard main engine exhaust wrap
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2006
Resolved 31 January 2006
Resolution: REPAIRED EXHAUST WRAP
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 30 January 2006 Resolved
Provide missing handles in engine room
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2006
Resolved 31 January 2006
Resolution: Installed missing handles.
Stability › Watertight Integrity › General
Issued 30 January 2006 Resolved
Crop and renew wasted fresh water tank bulkhead in way of starboard stack
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2006
Resolved 15 December 2006
Resolution: Blkhd cropped and renewed. Vent lines expanded to improve structural soundness.
Documentation › Safety/Response Plans/Programs
Issued 29 January 2003 Resolved
Provide a vessel Waste Management Plan. LEGACY COMPONENT DESC: Waste Management Plan
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 January 2003
Documentation › Safety/Response Plans/Programs
Issued 29 January 2003 Resolved
Have Fire Control Plan reviewed and approved by a C.G. inspector. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 January 2003
Operations/Management › Drills/Instruction
Issued 29 January 2003 Resolved
Provide an Emergency Broadcast Placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 January 2003
Communications › Audible Communications
Issued 29 January 2003 Resolved
Repair the ship's horn to provide a signal of the appropriated decibel level. LEGACY COMPONENT DESC: Horn/Whistle
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2003
Resolved 31 January 2003
Fire Fighting › Miscellaneous Items
Issued 29 January 2003 Resolved
Provide an approved fire extinguishing system for the paint locker. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 January 2003
Engineering › Diesel Engine (auxiliary)
Issued 29 January 2003 Resolved
Repair overspeed trip for prime mover on stbd. generator. LEGACY COMPONENT DESC: Overspeed Device
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2003
Resolved 31 January 2003
Electrical › Electrical Distribution System (service)
Issued 29 January 2003 Resolved
Repair ground detection lights on the main switchboard. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 January 2003
Engineering › Bilge Water Management System
Issued 29 January 2003 Resolved
Repair reach rod to the forepeak valve. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2003
Resolved 31 January 2003
Engineering › Fuel Oil Service System
Issued 29 January 2003 Resolved
Replace fuel hose on stbd. generator. LEGACY COMPONENT DESC: Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2003
Resolved 31 January 2003
Fire Fighting › Means of Escape
Issued 29 January 2003 Resolved
Stencil the emergency escape in the engineroom. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 January 2003
Engineering › Thrusters
Issued 29 January 2003 Resolved
Replace the actuator hose on the bow thruster engine. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 31 January 2003
Stability › Watertight Integrity
Issued 29 January 2003 Resolved
Replace packing and tighten stuffing tube in the forward bulkhead of the engineroom. LEGACY COMPONENT DESC: Stuffing Tube
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2003
Resolved 31 January 2003
Construction/Loadline
Issued 21 December 1992 Resolved
VESSEL IS TO PROCEED UNLAIDEN DIRECTLY TO HOUMA, LA TO AFFECT REPAIRS TO THE PORT STACK AND ALL OTHER INCURRED DAMAGE ON DECK. VESSEL TO ARRIVE NOT LATER THAN 24DEC92.
Condition: Unknown
Due 26 December 1992
Resolved 8 January 1993
Unknown
Issued 3 November 1983 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE CHERAMIE BO-TRUC NO. 32, DN599608.
Condition: Unknown
Due 3 November 1983
Resolved 3 November 1983
Unknown
Issued 3 November 1983 Resolved
PROVIDE UP-TO-DATE EDITIONS OF THE CHARTS FOR THE AREA OF OPERATION, TIDAL CURRENT TABLES, U. S. COAST PILOT #5, AND THE LIGHT LIST.
Condition: Unknown
Due 3 November 1983
Resolved 3 November 1983

Casualty record · 2

5 October 2011Routine · role: Involved in a Marine Casualty · activity 4166772
24 August 2013Routine · role: Involved in a Marine Casualty · activity 4697178
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ROSEANNA (2011–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.