MAURY USCG vessel records Sign in
← All vessels

MAISHA 1

MAISHA 1 is a 1980 offshore supply vessel. The Coast Guard has recorded 56 inspections since 1981, most recently in June 2026, along with 53 deficiencies and 2 operational controls.

Records from 1981 to 2026. Most recent: inspection, 3 June 2026.

Built
1980
Last inspected
3 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF2482
Flag
TANZANIA, UNITED REPUBLIC OF
367428620
Maury page id
psix-51297

Inspections, by type

…with no type recorded9
Years with a record 39 calendar years (1981–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF2482MMSI 367428620 · active · compulsorily equipped · granted 11 October 2019, expires 20 October 2029 · licensed under a name not among this hull’s recorded names (not shown)
WQZ8476MMSI 366995060 · expired · compulsorily equipped · granted 2 December 2004, cancelled 14 February 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 7

Inspection history · 56

3 June 2026 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8390218
11 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8157345
8 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8131395
20 February 2024 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7868311
29 March 2023 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7659407
20 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7655504
15 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7629548
30 November 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7359219
4 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7090465
28 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7086008
5 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6903114
30 October 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6845912
2 October 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6554258
12 March 2018 Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6370092
9 March 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6369034
24 October 2017 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6288803
3 August 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5956799
19 July 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4383092
5 August 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4104354
20 August 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3303726
17 March 2008 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3165890
7 August 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2738644
11 July 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2422745
28 April 2005 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2344132
23 September 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2202799
11 August 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2174656
18 August 2003 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1879516
23 August 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1665395
20 August 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444605
16 August 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415428
20 August 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391087
3 August 1999 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1510135
21 August 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381327
20 August 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414855
20 September 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383333
21 September 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374410
7 March 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449789
11 March 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358324
26 March 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420717
17 August 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 65792
24 March 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1257176
22 March 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899332
22 March 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955087
20 March 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897956
9 March 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914995
23 March 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1339581
23 March 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887355
23 March 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004000
10 April 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000021
11 April 1985 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015921
11 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290865
19 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285049
15 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276849
14 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277813
13 April 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272493
13 April 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276350

Deficiency record · 53

11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 15 February 2023 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry at least one rescue boat unless the cognizant OCMI determines that: The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Vessel's rescue platform when deployed over the side was angled inward which minimizes effective recovery area for crew member trying to recover a person from the water. Vessel to install vertical stanchions to the side of the hull to improve rescue platform angle when deployed over the side within 30 days. 46 CFR 180.210(a)(1)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 20 March 2023
Resolution: MSD LAF recd objective evidence (photo) of appropriately deployed and operational rescue platform.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 February 2023 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date Coast Pilots and Light Lists. Vessel had out of date Coast Pilot and Light List on board. Vessel to obtain current Coast Pilot & Light List within 30 days. 46 CFR 185.20-35(c)(d)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 20 March 2023
Resolution: MSD LAF recd objective evidence (photos) of current 2023 Coast Pilot and Light List onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 February 2023 Resolved
Standby vessels must have, at least, the following equipment: MI emailed vessel rep with all required Standby Vessel Endorsement equipment. Vessel rep to provide satisfactory objective evidence of required equipment or request endorsement be removed from COI. 33 CFR 143.405(a)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 March 2023
Resolution: MSD LAF recd objective evidence (photos) of required and available standby equipment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2021 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Marine inspector shall examine spaces to see no accumulation of oil or other matter which might create a fire hazard. Several dead end wires as well as hydraulic oil was observed in operating station. 46 CFR 183.05-50(b) 46 CFR 176.25-50 OLD T
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2021
Resolution: Inspection team cleared on def check. Vessel rep submitted photos of rectification.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 30 November 2021 Resolved
At each initial and subsequent inspection of certification, examination of condition of exterior of hull to take place at the satisfaction of the marine inspector. A large crack, allowing ingress of water, was observed on the stern rub rail. 46 CFR 176.25-5(a) OLD T
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2021
Resolved 2 December 2021
Resolution: Vessel rep submitted photos of repaired crack.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2021 Resolved
Suitable covers, guards or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Guard on Port Generator was missing. 46 CFR 177.35-15 OLD T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2021
Resolved 1 December 2021
Resolution: Vessel rep submitted a photo with a new protective guard.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 October 2020 Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. Vessels on deck hydraulic steering ram was missing securing devices on each of the rams securing pins, preventing the accidental backing out of the pins. Vessel shall replace secure devices prior to departure. 46 CFR 176.25-35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Vessel installed cotter pins in each of the required sections on the vessel steering ram.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 October 2020 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. During inspection, life float rack bars installed to prevent shifting were installed too tight, preventing the ability for the life floats to float free in an emergency situation. Vessel shall loosen rack bars to allow for proper installation prior to departure. 46 CFR 176.25-50(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Vessel cut out and rewelded bars allowing lifefloats to float freely if needed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2020 Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. During inspection, vessel ventilation above stove was observed missing grease screen and had excessive accumulation of grease buildup around vent area/fan. Note that this was a deficiency identified during last years annual inspection conducted by MSU Morgan City. Vessel shall clean and replace ventilation screen prior to departure. 46 CFR 176.25-50(b)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Vessel cleaned grease from area and replaced vent screen.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 October 2020 Resolved
All escape hatches and other emergenct exits shall be marked on both sides using at least 1-inch letters: Emergency Exit, Keep Clear unless such markings are deemed unnecessary by the [name withheld] hatch leading from the engine room onto the main deck was not permanently marked on both sides. Vessel shall permanently mark Emergency Exit, Keep Clear in 1-inch letters on both sides of the escape hatch. 46 CFR 185.30-15(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Vessel applied proper marking to vessel escape hatch.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 October 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. The vessels chart for area of operation was printed on October 10, 2020, updated up to week 40/20 and did not contain any chart corrections, nor were chart corrections being performed onboard. Vessel shall ensure charts are kept corrected/reviewed for corrections upon LNM release, for intended area(s) of operation. Vessel company shall ensure any updates are performed prior to departure and throughout the validity of the COI. 46 CFR 184.420
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Vessel ensured all charts onboard for intended voyage were corrected/updated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 October 2020 Resolved
Each Class 1 door on a vessel in ocean service must be designed to withstand a head of water equivalent to the depth from the sill of the door to the margin line but in no case less than 10 ft. (3.05 meters). The material condition of the knife edge near the bottom was wasted away and small holes were visible located on the main deck cabin watertight door knife edge. Vessel made temporary repair using epoxy to seal the knife edge. Vessel shall make permanent repairs to the main deck cabin watertight door knife edge to ensure watertight integrity within 14 days. 46 CFR 170.270(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 4 November 2020
Resolution: Vessel cropped and renewed with good metal area of concern.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2020 Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Dryer exhaust hose was torn, allowing accumulation of lint into the space and in vicinity of the engine exhaust. Vessel shall repair dryer exhaust hose prior to departure. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Vessel cut back damaged area on vent hose and re-attached/secured hose properly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 October 2020 Resolved
Standby vessels must have, at least, the following equipment: A fire monitor with a minimum flow rate of, at least, 500 gallons per minute. The material condition of the fire monitor pump while in operation was unsatisfactory as it leaks excessive water in the bilge while in operation. The vessel does not have a storage tank for waste oil, thus causing a potential pollution hazard to remove accumulated oil and water from the bilge. Vessel shall make permanent repairs to fire monitor pump so as to not leak excessively into the bilge. Vessel is not authorized to act in a standby vessel until permanent repairs are made. 33 CFR 143.405(a)(12)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 November 2020
Resolution: Vessel had service technician come onboard and completed a repacking of the pump packing gland which prevented leakage.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 October 2020 Resolved
Standby vessels must have, at least, the following equipment: A fire monitor with a minimum flow rate of, at least, 500 gallons per minute. The material condition of the fire monitor piping located in the laundry room is corroded in a small section of the pipe just before it exits the space. Vessel shall make permanent repairs to fire monitor piping located in the laundry room just before exiting the space. Vessel not authorized to act in a standby vessel service until permanent repairs are made. 33 CFR 143.405(a)(12)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 November 2020
Resolution: Vessel cleaned area and it was determined area of corrosion was only salt water indicative from a previous repair made adjacent to suspected area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 October 2020 Resolved
Hatches exposed to the weather must be watertight. Main deck hatch would not properly close and seal. Vessel shall make main deck hatch watertight and seal properly. 46 CFR 171.124(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 October 2020
Resolution: Vessel crew adjusted main deck hatch that allowed it to properly close and seal to ensure watertight integrity.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019 Resolved
All electrical equipment shall be so constructed so uninsulated parts cannot be inadvertently touched. Distribution panel in the machinery space had large opening with direct access to uninsulated parts. 46 CFR 183.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 5 November 2019
Resolved 5 November 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 October 2019 Resolved
Bilges and other spaces must not have accumulation of oil or other matter which might create a fire hazard. Bilges were found to have significant oily water accumulation. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 5 November 2019
Resolved 5 November 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2019 Resolved
Bilges and other spaces must not have accumulation of oil or other matter which might create a fire hazard. Galley vent hood had excess cooking oil caked into the fan and electrical equipment located within it. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 5 November 2019
Resolved 5 November 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2019 Resolved
Where liquid level indicating gages are installed on diesel fuel tanks, they shall be of heat resistant materials. Fuel tank sight glass is made of warped plastic. 46 CFR 182.20-25(5)
Condition: Improper Installation
Action required: 30 - Ship detained
Due 5 November 2019
Resolved 5 November 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 October 2019 Resolved
Vessel shall be fitted with ground tackle. Vessel's onboard anchors were seized and not serviceable with inaccessible anchor line. 46 CFR 184.10-1(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 5 November 2019
Resolved 5 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 October 2019 Resolved
A power driven vessels shall exhibit sidelights. Port side light bulb was extinguished. 33 CFR 83.23
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 30 October 2019 Resolved
A person may not employ or engage an individual in a position required to hold a MMC unless that individual maintains a current medical certificate. The Master's medical certificate was expired. 46 CFR 15.401(c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2019
Resolved 5 November 2019
Documentation › Certificates/Documents › Stability Letter
Issued 24 October 2017 Resolved
Vessels draft exceeds the limitations of the stability letter.
Action required: 60 - Rectify deficiencies prior to movement
Due 24 October 2017
Resolved 26 October 2017
Resolution: Removed all rig water from ballast tanks 2 port and 2 stbd, removed half the rig water from fwd peak void. Vessel draft fwd and aft withing restrictions of stability letter.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 24 October 2017 Resolved
Cable penetrations on the engine room overhead were missing packing to prevent fire, smoke or flooding.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 November 2017
Resolved 9 November 2017
Resolution: Installed packing.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 October 2017 Resolved
Back up power to navigation equipment was improperly wired to the charger not the battery. Vessels navigation equipment and radios did not have back up power.
Action required: 60 - Rectify deficiencies prior to movement
Due 24 October 2017
Resolved 26 October 2017
Resolution: Replaced battery, tested all required nav equipment with generators off line with sat results.
Engineering › Bilge Water Management System › Manifold
Issued 24 October 2017 Resolved
AFT engine room bilge suction pipe from manifold was missing.
Action required: 60 - Rectify deficiencies prior to movement
Due 27 October 2017
Resolved 26 October 2017
Resolution: Installed new bilge piping and strainer, tested sat
Electrical › Electric Supply System (service) › Battery Charger
Issued 24 October 2017 Resolved
Missing drip shield on the charger in the engine room.
Due 10 November 2017
Resolved 26 October 2017
Resolution: Installed drip shield on the charger in the engine room.
Fire Fighting › Fire Pumps › Arrangement
Issued 3 August 2016 Resolved
Mount for the fire monitor fire pump is deteriorating. Additionally, the horizontal stiffener has experienced significant corrosion. To be replaced at the next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 24 October 2017
Resolution: Inspected new mounts. Cleared deficiency.
Fire Fighting › Fire Pumps › Casing
Issued 19 July 2012 Resolved
Repair excess leaks on fire pump and replace pressure gauge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2012
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 July 2012 Resolved
Replace supply and return cooling hoses on both generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 July 2012 Resolved
Replace machinery guard on fuel pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2012
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 5 August 2011 Resolved
Renew both air receiver relief valves which are painted shut.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 August 2011 Resolved
Remove old vsl name from all PFD's and life rings.
Due 5 September 2011
Resolved 5 August 2011
Fire Fighting › Nozzles › Type
Issued 5 August 2011 Resolved
Obtain foam nozzle with like threads with fire hose and renew foam pickup in line proportioner.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 August 2008 Resolved
No current Coast Guard Light List on board
Due 19 September 2008
Resolved 23 August 2008
Navigation › Piloting/Steering › Compass Deviation Table
Issued 20 August 2008 Resolved
No Compass Deviation Table on board.
Due 19 September 2008
Resolved 23 August 2008
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 August 2006 Resolved
Renew flame screen on #5 vent pipe.
Due 7 September 2006
Resolved 9 August 2006
Personnel › Training › Visual Communications
Issued 7 August 2006 Resolved
Label both bridge engine remote shutoffs.
Due 21 August 2006
Resolved 9 August 2006
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 7 August 2006 Resolved
Clean both generator armatures.
Condition: Improper/Lack of Maintenance
Due 21 August 2006
Resolved 9 August 2006
Engineering › Fuel Oil Service System › Hose
Issued 7 August 2006 Resolved
Tighten all fuel service hoses on both main engines.
Condition: Improper/Lack of Maintenance
Due 21 August 2006
Resolved 9 August 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 7 August 2006 Resolved
Replace plastic wire ties in engine room with metal supports.
Due 21 August 2006
Resolved 9 August 2006
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 7 August 2006 Resolved
Install metal splash guards in back and on the sides of galley stove over wood surfaces.
Due 21 August 2006
Resolved 9 August 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 7 August 2006 Resolved
Replace all engine room light covers.
Condition: Improper/Lack of Maintenance
Due 21 August 2006
Resolved 9 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 August 2006 Resolved
Repair wiring for hot water heater in engine room.
Due 21 August 2006
Resolved 9 August 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 September 2004 Resolved
Replace port navigation light fixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2004
Resolution: Fixture replaced.
Construction/Loadline › Penetrations › Gasket
Issued 23 September 2004 Resolved
REplace all water tight door gaskets
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2004
Resolution: Gaskets replaced.
Stability › Watertight Integrity › General
Issued 23 September 2004 Resolved
Adjust engine room escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2004
Resolution: Corrected.
Engineering › Steering Gear System › Pin
Issued 23 September 2004 Resolved
Repin and rebush rudder pivot points.
Due 23 October 2004
Resolved 7 October 2004
Resolution: Replaced hydraulic ram and pins.
Communications › Radio Communications › EPIRB
Issued 18 August 2003 Resolved
Provide Registration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2003
Resolution: Registration Faxed to vessel.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 August 2003 Resolved
Clean battery boxes
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2003
Resolution: Battery boxes cleaned.
Lifesaving › Buoyant Apparatus
Issued 18 August 2003 Resolved
Replace life float paddles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2003
Resolution: Owners rep faxed invoice for four each new paddles for life float to MSU.
Documentation
Issued 20 September 1996 Resolved
PROVIDE PROOF OF PARTICIPATION IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 4 October 1996
Resolved 27 September 1996

Ownership record