INT'L GENERAL is a 1980 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1982, most recently in August 2011, along with 60 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2010.

Records from 1982 to 2011. Most recent: inspection, 23 August 2011.

Built
1980
Last inspected
23 August 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9533
Flag
UNITED STATES
367012270, 367312810 (licence lapsed)
Maury page id
psix-51917

Inspections, by type

…with no type recorded14
Years with a record 30 calendar years (1982–2011)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton
96 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD9533MMSI 367312810 · expired · voluntarily equipped · granted 11 September 2007, cancelled 11 November 2017
WDC3670MMSI 367012270 · expired · voluntarily equipped · granted 19 January 2005, cancelled 21 March 2015
WAD9426MMSI not assigned · expired · voluntarily equipped · granted 14 July 1994, cancelled 9 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 8

Inspection history · 54

23 August 2011 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4124241
2 November 2010 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3883425
25 February 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3685690
13 January 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3663077
22 July 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3547723
30 October 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3354582
22 October 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3087591
14 March 2007 Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2888092
8 August 2006 Ballast Water Examination · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2739780
10 June 2005 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2385937
11 May 2005 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2354801
23 March 2005 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2313995
20 August 2004 Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2171434
12 March 2004 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2023219
8 March 2004 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2021839
7 August 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1879514
18 March 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1487981
16 August 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437940
12 June 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820244
12 May 2000 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361470
12 May 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461972
12 March 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424546
11 March 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448879
4 September 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 962356
15 March 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461702
4 March 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077440
7 December 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753936
1 December 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 202011
16 February 1995 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357150
4 March 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423882
13 August 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 846659
8 February 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414115
17 August 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 65792
18 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 958566
17 March 1992 Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957879
5 March 1992 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1008830
2 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217971
4 March 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 997799
11 July 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925920
21 June 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930783
13 March 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241614
16 February 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925399
24 August 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038366
10 July 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890971
6 June 1989 Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889760
1 June 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897256
17 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326830
7 March 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003142
5 September 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298952
12 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980294
4 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281379
12 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281222
18 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970268
11 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276643

Deficiency record · 60

Lifesaving › Lifefloat › Serviceable
Issued 23 August 2011 Resolved
Renew all lifefloats on vsl.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 August 2011 Resolved
Refasten electrical panel on switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 23 August 2011 Resolved
Adjust both overspeeds on generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 23 August 2011 Resolved
Clean both armatures
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 August 2011 Resolved
Renew painted relief valves on both air receivers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 23 August 2011 Resolved
Replace engine room outlet boxes with one equipped with spring covers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 23 August 2011 Resolved
Remount light in engine room aft of switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 August 2011 Resolved
Renew gaskets on main deck vent covers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 August 2011 Resolved
Renew starboard vent cover pin to allow proper seal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 August 2011 Resolved
Remove paint from 01 deck stack vent covers to allow proper seal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 23 August 2011 Resolved
Renew transfer procedures so in compliance with 33 CFR 155.750
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 August 2011 No resolution recorded
Demonstrate man overboard, fire, and abandon ship drills for MI when vsl is removed from stack.
Action required: 17 - Rectify deficiencies prior to departure
Navigation › Piloting/Steering › Marine Charts
Issued 30 October 2008 Resolved
Chart for Calcasieu River onboard but dated from 2006 and never opened. Required vessel to have onboard updated navigation chart of sufficient scale to navigate the Calcasieu River.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 October 2008 Resolved
Donning instructions for type of jacket maintained on board was not posted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2008
Lifesaving › Lifebuoys › Approval
Issued 30 October 2008 Resolved
Three life buoys no longer had a CG approval number attached. The label was either removed or painted over. Required vessel to have onboard CG approved life buoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2008
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 30 October 2008 Resolved
One waterlight attached to a life buoy did not have a CG approval decal. Required port captain to provide a CG approved waterlight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 30 October 2008 Resolved
All circuit breakers in engine room need to be properly labeled for each respective service.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 31 October 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 30 October 2008 Resolved
Lamps on switchboard not illuminating properly. Repair as needed.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 2 November 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 October 2008 Resolved
Bilge alarm not properly reading in engineroom as located on panel.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 2 November 2009
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 30 October 2008 Resolved
Repair leaks on port inboard MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 30 October 2008 Resolved
Double clamp all cooling hoses in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2008
Documentation › Markings/Placards › Official Number (US)
Issued 30 October 2008 Resolved
Show or place official number in engine room. Official number was on bulkhead with marker.
Due 30 November 2008
Resolved 30 November 2008
Resolution: Vessel crew grounded off layers of paint and found official number punch marked.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 30 October 2008 Resolved
Place appropriate lagging over exhaust piping where missing.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 2 November 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 October 2008 Resolved
Remove or properly end exposed wiring in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2008
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 30 October 2008 Resolved
Repair all machinery gauges in engine room.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 2 November 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 October 2008 Resolved
Replace plastic wire hangers in overhead of engine room with appropriate metal bands.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 31 October 2008
Engineering › Steering Gear System › Ram
Issued 30 October 2008 Resolved
Port rudder arm ram bushing wasted beyond 75 percent and near failure. Replace/repair as appropriate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2008
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 30 October 2008 Resolved
Repair rudder angle indicator electrical system to ensure indicators are working properly.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 2 November 2009
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 8 August 2006 Resolved
Replace corroded electrical box iwo a/c unit. Located by aft steering station.
Action required: 705 - Other - as specified
Due 9 November 2006
Resolved 22 October 2007
Engineering › Bilge Water Management System › Strainer
Issued 8 August 2006 Resolved
Provide bilge strainer iwo engine room.
Action required: 705 - Other - as specified
Due 9 November 2006
Resolved 22 October 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 August 2006 Resolved
Provide missing covers for circut breakers located on switchboard.
Action required: 705 - Other - as specified
Due 9 November 2006
Resolved 22 October 2007
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 August 2006 Resolved
Provide fire control plan and submit for review.
Action required: 705 - Other - as specified
Due 9 November 2006
Resolved 22 October 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 11 May 2005 Resolved
Clean breathers on Port ME.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Resolution: Breathers cleaned.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 May 2005 Resolved
Provide proof of removal of excess oil from all bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Resolution: Witnesses removal of oily water from bilges.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 11 May 2005 Resolved
Replace leaking RACOR fuel filter/bowl on port ME.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Resolution: Fuel filter replaced.
Construction/Loadline › Structures › Deck Plating
Issued 11 May 2005 Resolved
Properly repair damaged section of port bulwarks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 June 2005
Resolved 10 June 2005
Construction/Loadline › Hull › Bottom Plating
Issued 20 August 2004 Resolved
Clean wasted area under engine room emergency escape hatch and starboard shaft for inspection by CG Marine inspector.
Action required: 705 - Other - as specified
Due 20 September 2004
Resolved 23 November 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 20 August 2004 Resolved
Provide electrical fixtures meeting explosive proof requirements for paint locker or remove all flamables from locker and CO2 system.
Action required: 705 - Other - as specified
Due 20 September 2004
Resolved 24 August 2004
Resolution: Removed all electrical fixtures in locker.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 20 August 2004 Resolved
Make repairs to port engine prior to sailing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 September 2004
Resolved 23 November 2004
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 20 August 2004 Resolved
Provide and install rudder angle indicator at both operationg stations.
Action required: 705 - Other - as specified
Due 20 September 2004
Resolved 24 August 2004
Resolution: Installed rudder angle indicators at both stations.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 March 2002 Resolved
REPLACE/REPAIR PILOT HOUSE STBD MDE TACH. LEGACY COMPONENT DESC: GAUGES
Condition: Improper/Lack of Maintenance
Due 18 March 2002
Resolved 18 March 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 March 2002 Resolved
DOUBLE NUT SHAFT PACKING RETAINING RING. LEGACY COMPONENT DESC: SHAFT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2002
Resolved 18 March 2002
Fire Fighting › Combustible Materials
Issued 18 March 2002 Resolved
REMOVE WOODEN SHELVES BUNGEE CORDED TO SIDE SHELL OUTBOARD OF PORT GENERATOR LEGACY COMPONENT DESC: SHELVES
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2002
Resolved 18 March 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 March 2002 Resolved
PROPERLY INSTALL JUNCTION BOXES UNDER PILOTHOUSE CONSOLE.
Condition: Improper Installation
Due 18 March 2002
Resolved 18 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 18 March 2002 Resolved
PROPERLY INSTALL FIXED CO2 SYSTEM FOR PORT PAINT LOCKER. REMOVE DRAIN VALVE AND SEAL HOLE IN BOTTOM OF PAINT LOCKER.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2002
Resolved 18 March 2002
Construction/Loadline › Penetrations
Issued 18 March 2002 Resolved
PROPERLY INSTALL SEWAGE TANK VENT, MOVE FROM PORT ENGINE ROOM INTAKE TRUNK LEGACY COMPONENT DESC: SEWAGE TANK VENT
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2002
Resolved 18 March 2002
Construction/Loadline
Issued 12 May 2000 Resolved
PROVIDE CHECK VALVES FOR EACH BILGE SUCTION LINE, IAW 46CFR 56.50-50. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Documentation
Issued 4 March 1994 Resolved
PROVIDE ON BOARD DOCUMENT RENEWAL STICKER.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Construction/Loadline
Issued 4 March 1994 Resolved
CROP OUT WASTED SHELL PLATE BENEATH STBD SHAFT TO GOOD METAL AND INSERT NEWPLATE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Construction/Loadline
Issued 4 March 1994 Resolved
REMOVE DOUBLER IN WAY OF BOTTOM PLATE BENEATH PORT SHAFT AND CROP OUT WASTED PLATED TO GOOD METAL AND INSERT NEW PLATE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Navigation
Issued 4 March 1991 Resolved
INSTALL SOUND POWERED PHONE SYSTEM IAW 113.30-25.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Navigation
Issued 4 March 1991 Resolved
INSTALL RUDDER ANGLE INDICATOR AT FORE AND AFT STEERING STATIONS IAW 113.40
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 13 March 1990 Resolved
INSTALL AND PROVE PROPER OPERATION OF MAIN ENGINE OVERSPEED TRIPS.
Condition: Unknown
Due 13 March 1990
Resolved 13 March 1990
Documentation
Issued 6 June 1989 Resolved
PROVIDE ON BOARD A COPY OF THE VESSEL FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO STATION LICENSE IN ACCORDANCE WITH 46 CFR 96.13-1(A).
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Navigation
Issued 6 June 1989 Resolved
MAKE OPERABLE THE VESSEL RUDDER ANGLE INDICATOR LOCATED ON THE BRIDGE IN ACCORDANCE WITH 46 CFR 113.40-5.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Unknown
Issued 1 June 1988 Resolved
PROVIDE A COPY OF THE VESSEL'S STABILITY LETTER TO THE MARINE SAFETY OFFICEMORGAN CITY.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Unknown
Issued 1 June 1988 Resolved
PROVIDE ADDITIONAL PORTABLE FIRE EXTINGUISHERS TO COMPLY WITH THE COI AND 46 CFR 95.50-10(A). 1 C-II FOR WHEELHOUSE AND 1 A-II FOR THE COMMUNICATIONCORRIDOR FOR A TOTAL OF 1 C-II, 1 A-II AND 3 B-II.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Unknown
Issued 1 June 1988 Resolved
PROVIDE AN ADDITIONAL RING BUOY WITH AN APPROVED WATER LIGHT AND LINE IN ACCORDANCE WITH 46 CFR 95.43-10(A) FOR A TOTAL OF 3, 2 WITH LIGHTS AND 2 WITH LINES. AS PER THE COI.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Navigation
Issued 12 March 1984 Resolved
REPAIR AND MAKE OPERATIVE THE RUDDER ANGLE INDICATOR AS REQUIRED BY 46 CFR 58.25-5D.
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984
Unknown
Issued 12 March 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE [name withheld], DN618162
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984

Casualty record · 1

13 January 2010Major Marine Casualty · role: Sighted in Area · serious marine incident, as classified · 1 dead · activity 3663077
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.