07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 November 2025
No resolution recorded
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Entire engine room is protected by a fixed fire extinguishing system. The space is not vapor tight which will result in the fire extinguishing system agent to escape limiting fire fighting capabilities. Make protected spaces vapor tight to the satisfaction of the attending USCG Marine Inspectors.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 November 2025
Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. Various areas of guard rails on the exposed decks showed signs of wastage and damage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 November 2025
Resolution: Witnessed handrail repairs made to the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2025
Resolved
The hydrants for exterior locations may substitute two 11/2 in outlets, each with a 11/2-in hose, supplied through a wye connection. 01 hydrant was found on the STBD side with a single 1 1/2in hose connected.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2025
Resolution: Received objective evidence the vessel has newly installed wye gate valve and 02 1 1/2" hoses on the hydrant. Hose was tested.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 November 2025
No resolution recorded
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. Aft door of accommodation space wasted on the bottom affecting weathertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2025
Resolved
Each outlet or junction box must have a cover unless a fixture canopy, switch cover, receptacle cover, or other cover is used. Junction box in the port side passageway in accommodation space was found to be missing a cover. Place appropriate cover over outlet box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2025
Resolution: Received objective evidence of the junction box repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 November 2025
Resolved
The integrity of any deck in way of a stairway opening, other than a stair tower, shall be maintained by means of “A” or “B” class bulkheads and doors at one level. The integrity of a stair tower shall be maintained by “A” Class doors at every level. The doors shall be of self-closing type. Multiple doors throughout the accommodation spaces did not close properly and are in need of adjustment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2025
Resolution: Received objective evidence the door was adjusted and self-closes properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 November 2025
No resolution recorded
Means and arrangements for securing and maintaining weathertightness shall ensure that the tightness can be maintained in any sea conditions. Gasket around opening in forward engineering space missing in sections affecting weathertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 November 2025
Resolved
Each immersion suit or anti-exposure suit must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. 02 immersion suits were spot checked and were fount with light battery expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 November 2025
Resolution: Objective evidence was received displaying newly installed lights with unexpired dates.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 7 November 2025
Resolved
The lifebuoys with attached self-igniting lights must be equally distributed on both sides of the vessel. 03 lifebuoys were found with missing activation tabs.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 November 2025
Resolution: Objective Evidence was received displaying the tabs installed correctly.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 November 2025
Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. Two self-contained breathing apparatus were overdue for annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 November 2025
Resolution: Received third party report of the servicing being conducted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 October 2025
Resolved
At each inspection for certification, periodic inspection and at other times necessary, the inspector will determine that all fire-extinguishing equipment is in suitable condition. USCG Marine Inspectors attended the vessel on 14Oct2025 to conduct an Annual Inspection. During attendance, inspectors found several items that needed immediate repair. In addition, representatives of the vessel notified the MI’s that both the CO2 and the Halon fire systems were down for service. It was determined the systems were down due to condemned bottles. It was discussed and agreed to schedule the inspection at a later date. The vessel is currently in an “maintenance downtime” till the end of the month. Vessel representatives and CG MI’s agreed it would be in the vessel’s best interest to schedule an inspection after the maintenance period is over. Provide Sector New Orleans with a plan for fire protection for the related spaces while both CO2 and Halon systems are down for service to the satisfaction of the attending MI. In addition, the vessel is restricted to the pier until a Annual COI is completed by Sector New Orleans. 46 CFR 91.25-20(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2025
Resolution: While conducting Annual inspection. Reviewed 3rd party installation report. Verified the system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2025
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Drawings of alterations shall be approved before work is started unless deemed unnecessary by the Officer in Charge, Marine Inspection. Submit, for approval, drawings as appropriate for all repairs to be conducted.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025
Resolved
In special cases, a detailed analysis of the entire structure or some integral part may be made by the Coast Guard to determine the structural requirements.
Multiple permanent and temporary cracks and defects were repaired in the port aft ballast tanks. Provide an assessment of structural condition of the alternate/starboard side.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2024
Resolved
A complete recharge shall be carried for each self-contained breathing apparatus, and a complete set of spare batteries shall be carried for each flashlight. The spares shall be stowed in the same location as the equipment it is to reactivate. Vessel lacked a complete recharge for each SCBA.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Inspected vessel's SCBAs, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 October 2024
Resolved
Bulkheads of galleys, paint and lamp lockers, and emergency generator rooms shall be of “A” Class construction. Galley did not have structural fire protection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2024
Resolution: Vessel welded opening between galley and messdeck, all SAT.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 October 2024
Resolved
When a compartment containing the emergency source of electric power, or vital components thereof, adjoins a space containing either the ship's service generators or machinery necessary for the operation of the ship's service generators, all common bulkheads and/or decks shall be protected by approved “structural insulation” or other approved material. Cable penetrations between the generator room and the machinery space below lacked approved insulation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2024
Resolution: Vessel filled cable penetrations with approved insulation, all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2024
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket. Lifejackets had expired lights attached.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2024
Resolution: All lifejacket lights were replaced, all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 16 October 2024
Resolved
Each vessel must have a line-throwing appliance approved under approval series 160.040. Each vessel must carry the equipment on the list provided by the manufacturer with the approved appliance and an auxiliary line that is at least 450 meters (1,500 feet) long. Vessel lacked 4 line-throwing appliances with auxiliary line and projectiles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Inspected line-throwing appliances, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 October 2024
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” Spaces protected by CO2 lacked appropriate signage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2024
Resolution: Vessel added signage on doors of generator room, the space protected by CO2.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 16 October 2024
Resolved
While at a port under the jurisdiction of the U.S., a ship is subject to inspection by the Coast Guard to determine that a valid IOPP Certificate is on board and that the condition of the ship and its equipment corresponds with the particulars of the certificate. An inspection under this section may include an examination of the Oil Record Book. Oil record book entries lacked corresponding receipts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 January 2025
Resolution: Vessel provided fuel receipt documentation
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 October 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel lacked chemical testing records for crewmembers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 January 2025
Resolution: Vessel provided chemical testing records for crewmembers, all SAT.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 16 October 2024
Resolved
The master, operator, or person who is in charge of a
ship shall ensure that all garbage is discharged ashore
or in accordance with §§ 151.66-151.73. The following factors, among others, may be considered by enforcement personnel in evaluating compliance with §§ 151.51 through 151.77: Records, including receipts, of garbage discharges at port reception facilities. Vessel lacked garbage receipts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: All SAT. Inspected garbage receipts.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 October 2024
Resolved
The owner of a vessel subject to inspection under section 3301 shall-(1) ensure that such a vessel is equipped with a vessel master key control, signage, and surveillance requirements regarding the Coast Guard's Sexual Assault and Sexual Harassment Prevention and Response programs for commercial vessels. Follow guidance in implementation IAW Coast Guard Policy Letters 23-04, 23-05, 23-06.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 March 2025
Resolution: All SAT. See narrative for activity 8088866.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 October 2024
Resolved
There shall be at least two means of escape from all
general areas accessible to the passengers, if carried,
or where the crew may be quartered or normally employed. At least one of these two means of escape shall be independent of watertight doors. Vessel lacked two means of escape from welder's room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2024
Resolution: Vessel repaired 2nd means of escape, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023
Resolved
Electric installations on vessels must ensure:(2) Protection of passengers, crew, other persons, and the vessel from electrical hazards.
Vessel #3 Generator Main Switchboard was not locked out and tagged out.
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
Resolution: Installed lock out tag out.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 12 October 2023
Resolved
Entries shall be made in the Oil Record Book on each occasion, on a tank to tank basis if appropriate, whenever any of the following machinery space operations take place on any ship to which this section applies—(2) Internal transfer of oil cargo during voyage.
Vessel conducted internal transfers that were not logged into the ORB.
Action required: 10 - Deficiency Rectified
Due 17 October 2023
Resolved 12 October 2023
Resolution: Made correctiive entries into.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 October 2023
Resolved
Audible alarms must generate sound pressure of at least 10dBA above ambient noise levels existing during normal operations w/ the ship underway in moderate weather.
Fire Detection audible alarm in the portable accommodation module was not producing audible noise.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 3 November 2023
Resolution: Received tech report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2022
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves located at the tank. Vessels starboard side emergency shutdown valve #1, emergency shutdown valve #2 and EMD high suction valve inoperable. 46CFR56.50-60(d)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2022
Resolved 28 October 2022
Resolution: Witnessed test fuel shut off valves.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2022
Resolved
Each firehose on each hydrant must have a combination solid stream and water spray firehose nozzle approved under subpart 162.027 of this chapter. Two fire nozzles at station #4 and on fire nozzle at station #8 were not of the approved type. 46CFR95.10-10
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2022
Resolved 28 October 2022
Resolution: Inspected replacement nozzles
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2022
Resolved
Ocean going sailing vessels and barges shall be provided with pumps connected to the bilge main as required under subpart 56.50-55(b)(1). Vessel bilge pump inoperable. 46CFR56.50-55(b)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2022
Resolved 28 October 2022
Resolution: Witnessed sat operation of bilge pump
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2022
Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. Junction box in engine room storage space missing caps. 46CFR111.05-3(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 28 October 2022
Resolution: Vessel capped junction box off
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2022
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves located at the tank. Vessels port side #1 fuel tank shutoff valve inoperable. Vessel crew repaired valve on the spot. 46CFR56.50-60(d)
Action required: 10 - Deficiency Rectified
Due 21 October 2022
Resolved 21 October 2022
Resolution: Corrected on spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel did not have current list of employees enrolled in program or current consortium letter.
46CFR16.230(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 2 November 2022
Resolution: Received letter of personnel under consortium.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 October 2022
Resolved
Dredges in or near a channel or fairways, in operations likely to restrict or affect navigation of other vessels must comply with the Bridge-to-Bridge Act. Vessels certificate was expired, obtain current certificate.
46CFR80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 3 November 2022
Resolution: O/O provided verified certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2022
Resolved
Electric installations on vessels must ensure the protection of passengers, crew, other persons, and the vessel from electrical hazards. Radio equipment in bridge was found with multiple dead-end wires. Repair or remove.
46CFR111.01-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 28 October 2022
Resolution: Electrician repaired dead-end wires to the satisfaction of attending MI's.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 21 October 2022
Resolved
It is intended plans be submitted as will clearly show the vessel's arrangement and required equipment. Vessel fire safety plan does not match current arrangement of safety equipment and does not label numbered portable fire extinguishers.
46CFR91.55-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 3 November 2023
Resolution: Approved Plan
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2022
Resolved
Portable extinguishers must be inspected at least once every 12 months. Vessels extinguisher for the paint locker had not been serviced since 2021.
46CFR97.15-60
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 28 October 2022
Resolution: Company had Hiller service extinguisher, provided MI's service report.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 October 2022
Resolved
A hydrostatic release unit (HRU) used in a float-free arrangement must be approved under approval series 160.162. All of the liferafts’ disposable HRU's were installed with an exp. date longer than the 2 year exp. date permissible.
46 CFR 199.130(c)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 16 November 2022
Resolution: O/O replaced HRU's
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 21 October 2022
Resolved
Portable fire extinguishers and their stations must be numbered in accordance with 46CFR97.37-23. Vessels extinguishers were not numbered.
46CFR95.50-10(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 3 November 2023
Resolution: Approved Plan
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 October 2022
Resolved
Each liferaft must be arranged for float-free launching and the arrangement must ensure that the liferaft, when released and inflated, are not dragged under by the sinking vessel. All of the liferafts’ (08) painter lines were installed incorrectly to the hydrostatic releases, preventing them from being cut from the vessel in an emergency.
46 CFR 199.130(c)(7)
Action required: 10 - Deficiency Rectified
Resolved 21 October 2022
Resolution: Crew re-attached all painter lines to the hydrostatic releases correctly in the presence of the MI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2022
Resolved
Each vessel must carry lifejackets approved under approval series 160.155, 160.176 or 160.177. Two of the lifejackets were condemned due to deterioration of the buoyant material inside the lifejacket.
46 CFR 199.70(b)
Action required: 10 - Deficiency Rectified
Resolved 21 October 2022
Resolution: Vessel carries more lifejackets than are requiregd by the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2022
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket. 12 lifejacket had expired lights.
46CFR199.70(b)(4)(i)
Action required: 10 - Deficiency Rectified
Resolved 21 October 2022
Resolution: The crew attached new lights.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 July 2021
Resolved
The inspection shall be such as to insure that the vessel, as regards the structure, boilers and other pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, lifesaving appliances, fire-detecting and extinguishing equipment, pilot boarding equipment, pollution prevention equipment, and other equipment, is in satisfactory condition and fit for the service for which it is intended. Vessel was still in process of completing multiple repairs from drydock and was not ready for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 July 2021
Resolved
The assignment of load lines is conditioned upon the structural efficiency and satisfactory stability of the vessel, and upon the provisions provided on the vessel for effective protection and that of the crew. A hole was found on the port side of superstructure to engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 July 2021
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Vessel's life rafts were ashore getting serviced at time of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2021
Resolved
The general construction of the vessel shall be such as to minimize the fire hazards insofar as is reasonable and practicable. Vessel's Portable Accommodation Module (PAM) Serial CG1537262 is damaged and door would not properly close. Vessel restricted from utilizing PAM and limited to carrying 48 industrial passengers until repaired as per manufacturer to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 6 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 July 2021
Resolved
The emergency power source must have the capacity to supply all loads that are simultaneously connected to it. Emergency generator is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2021
Resolved
A vessel engaged in dredging or underwater operations, when restricted in her ability to maneuver, shall exhibit the lights and shapes prescribed in paragraphs (b)(i), (ii), and (iii) of this Rule. Vessel's dredge lights were in the process of being moved.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 8 July 2021
Resolved
All crew spaces are to be constructed and arranged in a manner suitable to the purpose for which they are intended. Vessel's lever room/pilot house windows are in the process of being replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 6 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2021
Resolved
Means shall be provided for closing all openings to the space protected from outside such space. Fire dampers in both center and stbd engine room intake does not close.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 July 2021
Resolved
There shall be at least two means of escape from all general areas where crew may be quartered or normally employed. Throughout the accommodation spaces the second means of escape are blocked by various items being stored. In the avetron room one door would not open and had caution tape posted on it.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 July 2021
Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Two emergency lights in engine room were inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 14 July 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 July 2021
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval. Emergency lights are not identified on fire and safety plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 3 November 2023
Resolution: Approved plan
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Each outlet or junction box must have a cover. In spud room, junction box in overhead is missing cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Equipment for interior locations not requiring exceptional degrees of protection must be manufactured to at least NEMA 250 Type 1 with dripshield or IEC 60529 IP 11 as specified in IEC. Vessel missing drip shield on battery charger in spud room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 8 July 2021
Resolved
Each berth must have a light. Master’s stateroom and Operator’s state room are missing bunk lights. Operator’s state room has exposed wiring where bunk light should be. Multiple other stateroom lights did not work tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Each berth must have a light. Master’s stateroom and Operator’s state room are missing bunk lights. Operator’s state room has exposed wiring where bunk light should be. Multiple other stateroom lights did not work tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2021
Resolved
The Marine Safety Center may approve any arrangement, fitting, appliance, apparatus, equipment, calculation, information, or test that provides a level of safety equivalent to that established by specific provisions of this subchapter. Vessel is utilizing multiple unapproved power strips through out accommodation spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Each flexible cord and cable must be connected to a device so that tension is not transmitted to joints or terminal screws. Vessel's speaker horn in engine room is hanging via it's wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 8 July 2021
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. No receipts on board as required by garbage management plan. Prove garbage management plan is being followed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 8 July 2021
Resolved
The shipboard oil pollution emergency plan must be available on board. Current revision of the SOPEP not on board. Prove updated copy of SOPEP is on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 14 July 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 December 2020
Resolved
Previous wire penetration at top of generator room leading into accommodation house needs to be capped or plugged to maintain fire boundary. 46 CFR 92.07-10 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 16 December 2020
Resolution: Hole plugged by crew.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 December 2020
Resolved
Two (02) Class A fire doors from generator space into accommodation space and one (01) Class A fire door from engine room into accommodation space do not fully close and latch. Make repairs and prove proper operation. 46 CFR 92.07-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 16 December 2020
Resolution: New fasteners and latching devices installed on doors.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 December 2020
Resolved
Electrical cable penetrations in the deck from the generator space into engine room are missing fire stop and must be repaired to maintain fire boundary. 46 CFR 92.07-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 16 December 2020
Resolution: Penetration plugged with 3M fire block.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 December 2020
Resolved
Multiple electrical cable penetrations in the blkhd from engine room into engine control room are missing fire stop and must be repaired to maintain fire boundary. 46 CFR 92.07-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 16 December 2020
Resolution: Penetrations plugged with 3M fire block.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 December 2020
Resolved
Engine control room watertight door to weather deck seized closed, preventing emergency escape. Make repairs and prove proper operation. 46 CFR 92.10-5
Action required: 10 - Deficiency Rectified
Resolved 7 December 2020
Resolution: Crew repaired door. MI witnessed proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 December 2020
Resolved
Multiple dogs seized on stbd engine room watertight door. Make repairs and prove proper operation. 46 CFR 42.15-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 16 December 2020
Resolution: Door repaired.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 December 2020
Resolved
Life jacket donning instructions at muster station do not correspond with the life jackets onboard. Post donning instructions for life jackets carried. 46 CFR 199.80 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 22 December 2020
Resolution: New instructions installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 December 2020
Resolved
Reposition liferaft painter plug to maintain integrity of liferaft canister. 46 CFR 199.45(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 16 December 2020
Resolution: Plug properly installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 7 December 2020
Resolved
Re-install access cover on MSD holding tank. 33 CFR 159.101
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 16 December 2020
Resolution: Cover properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 December 2020
Resolved
Install chaffe gear on flexible hose lines on all diesel engines, as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 16 December 2020
Resolution: Chafe gear installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 December 2020
Resolved
Address various oil leaks on main pump diesel engines. Make repairs and prove proper operation. 46 CFR 91.25.45(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 22 January 2021
Resolution: Repairs made to engines. Crew to monitor for further leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 December 2020
Resolved
Tighten air start hoses on main pump and main generator diesel engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 16 December 2020
Resolution: Hoses tightened.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 December 2020
Resolved
Electrical cables in anchor winch room are ziptied to overhead. Secure with metal bands or brackets. 46 CFR 111.60-5 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 26 January 2021
Resolution: Received pictures.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 7 December 2020
Resolved
Previous bolt hole in the port side of engine room bulkhead must be plugged. 46 CFR 42.09-1 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2021
Resolved 16 December 2020
Resolution: Hole plugged.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 7 December 2020
Resolved
The steel under the forward walkway in the engine room was wasted out. Make repairs prior to credit drydock. 46 CFR 42.09-1 (a)
Action required: 705 - Other - as specified
Resolved 18 May 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 7 December 2020
Resolved
The steel on the stbd, fwd quarter of the engine room bulkhead by the electrical junction box must be gauged and replaced as necessary prior to credit drydock. 46 CFR 42.09-1 (a)
Action required: 705 - Other - as specified
Resolved 6 August 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 7 December 2020
Resolved
Wingnuts for the main pump cover must be repaired and replaced as necessary. 46 CFR 42.09-1 (a)
Action required: 705 - Other - as specified
Resolved 18 May 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 November 2020
Resolved
The assignment of load lines is conditioned upon the structural efficiency and satisfactory stability of the vessel, and upon the provisions provided on the vessel for effective protection and that of the crew. Inspectors found wastage beyond allowance and holes in the vessel's superstructure. Vessel has placed temporary repair patches on those areas. Permanent repair must be made at drydock or by 31Jan2021, whichever occurs first.
Action required: 705 - Other - as specified
Due 31 January 2021
Resolved 6 August 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 November 2020
Resolved
In general, compliance with the standards established by ABS will be considered satisfactory evidence of structural efficiency. Web frames 27 and 28 on port side of engine room, as well as frame 41 in engine room are holed. Vessel has place a doubler on those frames. Permanent repair must be made at drydock or by 31Jan2021, whichever occurs first.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2021
Resolved 18 May 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 November 2020
Resolved
Complete but simple instructions for the operation of the fire extinguishing systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. Vessel created temporary instructions for CO2 system and Halon system until permanent placard from manufacture arrives.
Action required: 705 - Other - as specified
Due 8 December 2020
Resolved 22 January 2021
Resolution: Permanent placard installed.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 4 November 2020
Resolved
Drawings of alterations shall be approved before work is started unless deemed unnecessary by the Officer in Charge, Marine Inspection. Shipyard is adding a fire pump to the vessel in addition to the existing ones. Vessel must submit plans of modification to the Marine Safety Center for approval. Once plans are approved and any comments are resolved, system installation must be installed per approved plan and verified by the attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2020
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull shall be made without the knowledge of the Officer in Charge, Marine Inspection. Went onboard vessel and found unauthorized crop and renew of port side shell plating as welll as a weld on 20 inch crack located port side IWO pump room hatch. Vessel to provide USCG with detailed repair proposal for review and approval.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Vessel submitted repair proposal.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 October 2020
Resolved
Fire hydrants must be of sufficient number and so located that any part of the vessel, other than main machinery spaces, accessible to persons on board while the vessel is being navigated and all cargo holds may be reached with at least 2 streams of water from separate outlets. Fire main at stations #9 and #29 is holed and leaking. Additionally, 10 sections of fire main in the engine-room had unauthorized temporary repairs (6 clad weld and 4 soft patches). This condition is rendering ineffective stream of firefighting water from outlet. Effect permanent repairs ensuring proper operation of firefighting arrangement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 November 2020
Resolution: Vessel replaced entire firemain.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 October 2020
Resolved
On vessels of 500 gross tons or more there must be at least one shore connection to the fire main available to each side of the vessel in an accessible location. While the shipboard fire pumps are out of service due to maintenance, the vessel depends on shore-side connection operation for firefighting. Inspectors found port shore-side connection valve inoperable and holed, and Stbd damaged so as to impede the connection from providing sufficient water pressure at any fire station. Prove proper operation of shore side connections.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 October 2020
Resolved
The assignment of load lines is conditioned upon the structural efficiency and satisfactory stability of the vessel, and upon the provisions provided on the vessel for effective protection and that of the crew. Wastage and holes on the hull, bulkheads, and pipes adversely effect watertight and weather-tight integrity, create down-flooding points that affect subdivision, and allow the unintended movement of fluids into compartments not considered for the vessel’s stability. Inspectors found wastage beyond allowance, severe pitting, and holes in vessel’s structures that are critical to its stability and subdivision, to include: 1) #3P diesel fuel tank, leaking into the engine compartment, 2) #3S fuel tank and overflow pipe, leaking fuel into the adjacent sea-chest void, 3) on the weather-deck to EDG space, 4) on the superstructure to the 01 deck accommodation spaces and 02 bridge deck, 5) on ballast ,void, lube oil and fuel (vents) 6) on the stbd sea-chest and port raw water manifold and 20" pipe at sea-chest intake, 7) on the mechanical ventilation for EDG and Main space Engine room are holed, and 8) hole in Side shell on stbd side at frame 34. The vessel may not sail until it provides a comprehensive structures gauging report to identify the extent of wastage, and effect permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 November 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 October 2020
Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of this subchapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. 20 inch crack in a structural beam was found on port side support for dredge head. This condition could lead to the collapse of dredge head crane. Effect permanent repairs that meet ABS structural standards.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 October 2020
Resolved
In general, compliance with the standards established by ABS will be considered satisfactory evidence of structural efficiency. Significant wastage in starboard sea chest valve void space. Show wasted plate complies with ABS structural standards.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 October 2020
Resolved
In general, compliance with the standards established by ABS will be considered satisfactory evidence of structural efficiency. Web frames 27 and 28 on port side of engine room are holed. Affect permanent repairs that meet ABS structural standards.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 October 2020
Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of this subchapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. Holes were found on frame #41 in E/R . Make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2020
Resolved
Each bilge suction must lead from a manifold unless approved by MSC. Bilge manifold aft suction has weld leaking bilge water. Prove proper operation of bilge system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020
Resolved
Electrical installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Throughout the entire vessel, but especially on the bridge, multiple power strips and extension cords are being utilized due to location and availability of existing receptacles. Provide proper outlets as required.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020
Resolved
If the installation of the electrical equipment does not ensure a positive ground to the metal hull or equivalent conducting body, the apparatus must be grounded to the hull with a grounding conductor. Vessel’s grounding wire for equipment under bridge is connected to the hull with a metal clamp. Remove temporary arrangements and make permanent.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020
Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. The conductor going into the battery charger for the bridge navigation equipment is exposed. Ensure conductor is not exposed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 October 2020
Resolved
In a space described in 113.25-9(a), where the general emergency alarm signal cannot be heard over the background noise, there must be a red flashing light or rotating beacon, in addition to the general emergency alarm signal. Light for general alarm on the port side of engine room is not flashing. Prove proper operation of emergency light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020
Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. Throughout vessel there are multiple dead end wires with electrical tape wrapped around the end of the wire. Properly terminate all identified wires.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2020
Resolved
All safety and relief valves for use on pressure vessels shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the "maximum allowable working pressure" of the pressure vessel. Air receiver for aft crane has a broken safety relief valve. Prove proper operation of relief valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 October 2020
Resolved
Complete but simple instructions for the operation of the fire extinguishing systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. Instructions posted for operation of the generator room fire suppression system was that of an old system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 October 2020
Resolved
Emergency lighting should provide illumination in the portable accommodation modules (PAM) for the same period required for the host vessel. Neither PAM had working emergency lighting. Prove proper operation of emergency lighting.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2020
Resolved
Prior to installation aboard vessel, diagrams of the following systems shall be submitted for approval: Fuel oil service, bilge and ballast piping. Vessel has made modifications to their engineering systems and vessel representative could not produce approved plans.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 October 2020
Resolved
There shall be at least two means of escape where the crew may be quartered or normally employed. In the portable accommodation module the door leading to the emergency exit was locked.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 19 November 2020
Resolved 19 November 2020
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 14 October 2020
Resolved
A survey shall be made every time a defect is discovered which affects the safety of the vessel or whenever important repairs are made. Vessels has pitting over 1/4" on #3 Stbd fuel tank. Provide corrective action plan acceptable to the OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020
Resolved
Engine design. All Installations shall be of marine type. Engines suitable for the intended service. Raw water leaks were found on stbd sea chest and port cat raw water manifold. Provide corrective action plan acceptable to the OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2020
Resolved 24 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020
Resolved
A survey shall be made every time a defect is discovered. Reduction gear for pump motors are leaking gear oil. Provide acceptable repairs to the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2020
Resolved 24 November 2020
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 October 2020
Resolved
A survey shall be made every time a defect is discovered which affects the safety of the vessel or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made. The material and the workmanship of such repairs or renewals are in all respects shall be satisfactory, and that the vessel complies in all respects with the regulations. Vessel is leaking fuel from 3 Port into engine room. Provide acceptable repair plan to OCMI addressing corrective actions for leak on fuel tank number 3 Port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 31 August 2020
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Vessel has approximately 3"x1" crack on the tank top of cargo tank #__. Vessel shall affect permanent repairs approved by the Coast Guard and test tank to 5 psi prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 18 September 2020
Resolved 7 September 2020
Resolution: All repairs were made in presence of USCG and ABS. Test pressure was lowered to 2.0 PSI. ABS will issue a Statuary finding for Spigot patch workmanship and accept as a temporary repair, due at next dry dock. See QA sheet in vessel documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2020
Resolved
Non self-propelled vessels shall be provided with pumps connected to the bilge main. Vessel is unable to prove proper operation of the bilge pump suction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 13 February 2020
Resolution: repaired
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 February 2020
Resolved
The structural standards of the vessel must be in compliance with the standards establisted by ABS. MI identified a cracked structural member in the E/R and a hole in the deck in the swing winch room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2020
Resolved 13 February 2020
Resolution: repaired crack
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2020
Resolved
Electral installations on vessels must ensure protection of crew and the vessel from electrical hazards. MI identified mutiple cable terminations and junction boxes that were incorrectly placed into service. Also a 480V cable not removed from service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2020
Resolved 13 February 2020
Resolution: secured all J boxes
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2020
Resolved
Machinery capable of injuring personnel shall be provided with covers or guards. Main engine shaft guard is damaged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2020
Resolved 13 February 2020
Resolution: vessel made and installed guards
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 February 2020
Resolved
Vessel subject to load line have special requirements as to the closure of openings in water tight bulkheads. The self-closing device for the WTD in the port and stbd entrance to the crew lounge needs to be adjusted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2020
Resolved 13 February 2020
Resolution: made adjustment to doors
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 February 2020
Resolved
Vessel must have all emergency lighting in proper operation. MI identified the #11 e-light port side main deck is not working.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2020
Resolution: replaced light
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2020
Resolved
Each item of survival equipment with an expiration date must be replaced during the annual inspection. The battery installed in the ring lifebuoy was the incorrect style.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2020
Resolution: Vessel replaced battery
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 October 2019
Resolved
Approved hand portable fire extinguishers shall be installed on board. Vessel was missing all portable extinguishers in both of the PAM's installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 October 2019
Resolved
Each fire detector should be approved under 46 CFR 161.002 with satisfactory operation to the USCG. Vessel rep was unable to find a can of smoke to conduct tests on the PAM's detection system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 October 2019
Resolved
Emergency lighting should provide illumination for the same period required for the host vessel. Both PAMs had various E-lighting that did not work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 October 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 October 2019
Resolved
Each general alarm signal should be marked "GENERAL ALARM - WHEN EMERGENCY ALARM SOUNDS GO TO YOUR STATION" in red letters at least 1/2 inch high. None of the general alarms were labeled in either PAM.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 17 October 2019
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 1 October 2019
Resolved
A general arrangement plan should clearly show location on the host vessel where the PAM is installed, details of the accommodation spaces, means of escape, guard rails, lifesaving, and firefighting appliances. Vessel did not have an updated general arrangement plan on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 17 October 2019
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 1 October 2019
Resolved
The fire and safety plans should be updated to reflect the additional safety equipment associated with PAM installation and be posted in a conspicuous location inside the PAM. Neither PAM had an updated fire and safety plan posted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 17 October 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 1 October 2019
Resolved
There shall be at least two means of escape from where the crew may be quartered. Vessel was storing various objects in areas where a means of escape was located.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 17 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2019
Resolved
The general construction shall be as such to minimize fire hazards and electrical hazards on board. Vessel has the hot water heater wired through an extension cord that runs down to the wall in the PAM's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 1 October 2019
Resolved
Each immersion suit must be designed so that a light is attached to its front shoulder. Vessel did not have a light on any immersion suit located in the PAMS nor were the locations of the immersion suits marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 17 October 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 March 2019
Resolved
An inspection shall be made whenever any important repairs or alterations are undertaken. Vessel discovered and reported a pinhole leak in an internal fuel tank. Tank has been emptied and will remain empty until permanent repairs are made. Permanent repairs are to be made to the satisfaction of the USCG within 60 days at next maintenance availability.
Action required: 705 - Other - as specified
Due 16 May 2019
Resolved 11 June 2019
Resolution: Repairs were made and tested, sat.
Construction/Loadline › Hull › Weld
Issued 1 November 2017
Resolved
A 6"x 1.5" crack at the #1 port fuel tank top and damaged handrail stanchion was caused by a collision with a tug. The vessel shall make temporary repairs to fuel tank top and stanchion by removing fuel within the tank and isolating the tank from the fuel systems. The opening shall be minimized and sealed to prevent down flooding as discussed with vessel chief engineer. The vessel shall submit a repair proposal for permanent repairs and once approved, complete the repairs no later than 15FEB17. 46CFR 91.45-1, 46CFR 92.01
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 19 December 2017
Resolution: Received proof of proper repairs
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 3 October 2017
Resolved
Time delay for halon system did not activate in proper amount of time. Replace time delay. 46 CFR 95.16-90 and 46 CFR 95.16-45. Prior to operating machinery in effected space.
Due 3 October 2017
Resolved 12 October 2017
Resolution: New Nitrogen pilot bottle installed with 34 second time delay. Tested and released at 34.5 seconds.
Lifesaving › Immersion Suits › General
Issued 3 October 2017
Resolved
Immersion suits not stored in accordance with the fire control plan. 46 CFR 97.36-1(a)
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 12 October 2017
Communications › Alarms/Indicators › General Alarm
Issued 3 October 2017
Resolved
General alarm in Survey Office doesn't properly work.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 12 October 2017
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 3 October 2017
Resolved
Remote Halon activation station doesn't have operation instructions. 46 CFR 95.16-50(a)
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 12 October 2017
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 October 2017
Resolved
Fire Control Plan doesn't show forward starboard fire plug in engine room.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 12 October 2017
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 October 2017
Resolved
Survey Office switchboard not labeled.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 12 October 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 October 2017
Resolved
Motor control latch on 480V panel in engine control room broken.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 12 October 2017
Engineering › Fuel Oil Service System › Tank
Issued 20 September 2017
Resolved
Provide a repair proposal to attending MI for PORT fuel tank #2 prior to commencing any repairs.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 September 2017
Resolution: 41" x 36" x 1/2" steel plate insert used to repair fuel tank. Satisfactory inspection of cut-out, fit-up, backgouge, and final weld test (pressed up to 1.5 psi).
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 20 September 2017
Resolved
Provide a satisfactory Marine Chemist Certificate for Fuel Tank #2 Port prior to entry or starting any machinery except air compressors, MSD or Potable water.
Action required: 705 - Other - as specified
Resolved 21 September 2017
Resolution: Provide satisfactory Marine Chemist Cert and satisfactorily cleaned the remaining excess oil/fuel out of the bilges.
Construction/Loadline › Structures › Deck Plating
Issued 20 April 2016
Resolved
Submit repair proposal for wasted flying bridge deck and deck supports. 46CFR91.40-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2016
Construction/Loadline › Structures › Deck Plating
Issued 20 April 2016
Resolved
Repair wasted deck (holes) at top of ladder stbd side, from 3rd deck to flying bridge. 46CFR91.40-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2016
Construction/Loadline › Structures › Superstructure
Issued 20 April 2016
Resolved
Repair wasted stbd side ladder support frame (at top) from 3rd deck to flying bridge. 46CFR91.40-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2016
Fire Fighting › Fire Main › Condition
Issued 20 April 2016
Resolved
Repair wasted firemain pipe bracket 3rd deck stbd side ovhd next to ladder to flying bridge. 46CFR91.40-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2016
Construction/Loadline › Structures › Superstructure
Issued 20 April 2016
Resolved
Repair wasted stanchion support for the 4th deck walkway on 3rd deck aft of forward house. 46CFR91.40-3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2016
Construction/Loadline › Hull › Side Shell
Issued 4 March 2016
Resolved
#1 center void stbd, crack in side shell. Crop and renew.
Action required: 705 - Other - as specified
Resolved 15 June 2016
Resolution: Side shell repaired IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Structures › End Bulkhead
Issued 4 March 2016
Resolved
Repair wasted house bulkhead areas at deck level to provide good steel for deck welds.
Action required: 705 - Other - as specified
Resolved 22 June 2016
Resolution: All wasted areas repaired IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 February 2016
Resolved
Crack in #1 center void aft bay deck frame stbd side. Crop and renew.
Action required: 705 - Other - as specified
Resolved 15 June 2016
Resolution: Crack repaired IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 February 2016
Resolved
#1 fwd potabel water tank: replace wasted piping.
Action required: 705 - Other - as specified
Resolved 8 June 2016
Resolution: Piping replaced IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Bottom Plating
Issued 18 February 2016
Resolved
Numerous holes in bottom shell. Crop and renew where marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2016
Resolution: All holes repaired IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 February 2016
Resolved
#8 Port void aft outboard bottom long missing section.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2016
Resolution: Repaired longitudinal IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Bracket
Issued 18 February 2016
Resolved
Number 3 fuel tank fwd/side long missing tripping bracket at the swash blkhd
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2016
Resolution: Installed tripping bracket IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 February 2016
Resolved
#1 fuel tank stbd aft bay outboard long 5th from bottom major deflection
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2016
Resolution: Crop and renewed longitudinal IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 February 2016
Resolved
Stbd Potable water tank aft Deck Longitudinal/Beam is severely wasted. Replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2016
Resolution: Replaced longitudinal IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Hull Plating
Issued 18 February 2016
Resolved
Port Potable Water tnk Crop and Renew inset between longs 5-8 from bottom aft, outboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2016
Resolved 19 May 2016
Resolution: Repaired inset IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 February 2016
Resolved
Port oily water tank top 2 longs in fwd of compt. on outboard side crop and renew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2016
Resolution: Longitudinals replaced IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 2 February 2016
Resolved
#1 fwd potable water tank bulkhead; crop and renew areas marked due to wastage.
Action required: 705 - Other - as specified
Resolved 8 June 2016
Resolution: Marked areas repaired IAW applicable regs and to the satisfaction of marine inspector and ABS.
Construction/Loadline › Markings › Summer Load Line
Issued 2 March 2015
Resolved
Plimsol mark and summer load line is not painted in contrasting color on stbd side of hull. Operator is required to paint contrasting color.
Action required: 705 - Other - as specified
Resolved 7 April 2015
Resolution: Veiwed photos and attestation from Chief Engineer as to painted plimsoll.
Communications › Alarms/Indicators › General Alarm
Issued 2 March 2015
Resolved
Operator must ensure General Alarm is audible IWO the Laever Room.
Due 16 March 2015
Resolved 7 April 2015
Resolution: Veiwed photograph and attestation of Chief Engineer that bell has been installed and is fully operational.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 2 March 2015
Resolved
Operator must renew all expired smoke detectors.
Due 16 March 2015
Resolved 4 March 2015
Resolution: Received photo of new smoke detectors and attestation from Chief Engineer verifying operability of same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 March 2014
Resolved
Exposed electrical wires for light fixtures must be covered (various locations).
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessel installed covers over exposed wiring
Fire Fighting › Fire Main › Condition
Issued 30 March 2014
Resolved
Repair cracked fire main pipe, port side engine room, on 03 deck near fire station.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessel replaced damaged sections of fire main piping.
Operations/Management › Drills/Instruction › Fire
Issued 30 March 2014
Resolved
Update fire and safety plan to meet existing conditions. Station #30 does not exist. 3rd deck fire station not in plan.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessel made corrections to the fire plans kept and posted onboard.
Electrical › Electric Generation Source (service) › Generator
Issued 30 March 2014
Resolved
Demonstrate proper operation of all safety shutdowns for Caterpillar generator.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessels demonstrated satisfactory operation of the high water temp shutdown, low lube oil PSI shutdown and the over speed shutdown.
Communications › Radio Communications › EPIRB
Issued 30 March 2014
Resolved
Replace hydro-static release for EPIRB.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: A new hydrostatic release for the vessels EPIRB was installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 March 2014
Resolved
Replace existing white light fixture for restriction of maneuverability to approved type meeting nave-rules.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessel installed new navigation type marine light fixtures.
Engineering › Fuel Oil Service System › Tank
Issued 30 March 2014
Resolved
MPT for fuel additive needs to be hydro-tested, unable to read last test date.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: The marine portable tank was removed from the vessel; no longer in use.
Engineering › Compressed Air System (control) › Valve
Issued 30 March 2014
Resolved
House Air Receiver relief valve must be tested in presence of CG Inspector.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessel demonstrated satisfactory operation of the air receiver relief valve; valve lifted at 125 PSI
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 30 March 2014
Resolved
Install mechanical closure devices for M/V XFEMR and MPT containment boxes.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessel installed threaded pipe plugs into containment drains.
Fire Fighting › Fire Pumps › Arrangement
Issued 30 March 2014
Resolved
Repair and prove proper operation of vessel's second fire pump to attending MI.
Action required: 705 - Other - as specified
Due 1 May 2014
Resolved 30 April 2014
Resolution: Vessel demonstrated satisfactory operation of secondary fire pump using one hose on the deck
Documentation › Markings/Placards › Warning Signs
Issued 23 February 2012
Resolved
Place signs at General Alarms. Should read " General Alarm, When bell rings go to your station"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2012
Resolved 20 March 2012
Construction/Loadline › Structures › Superstructure
Issued 23 February 2012
Resolved
Crop ans renew wasted area at the baseof the forward catwalk. (bulkwark and deck).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2012
Resolved 20 March 2012
Construction/Loadline › Structures › Superstructure
Issued 23 February 2012
Resolved
Crop and renew wasted bulwark and deck out side of the control room fwd. Due by next dry-dock (03JAN2014).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2014
Resolved 8 October 2013
Resolution: Cleared,
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 January 2011
Resolved
Have OWS plan approval completed and complete install as required by MARPOL annex I regulation 14.1, or obtain a letter of exemption from CG HQ (CG-5431) authorizing an alternate method of compliance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2011
Resolved 20 March 2012
Construction/Loadline › Structures › Superstructure
Issued 25 March 2010
Resolved
Renew navigation light support structure.
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 12 January 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 March 2010
Resolved
Remove tie wraps and install appropriate fencing securing devices around high voltage equipment on 2nd deck.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 16 April 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 March 2010
Resolved
Install electrical outlet for freezers in cat room and remove extension cord.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 16 April 2010
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 25 March 2010
Resolved
Plug pipe openings in cat room aft bulkhead.
Action required: 705 - Other - as specified
Due 26 April 2010
Resolved 16 April 2010
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 25 March 2010
Resolved
Install cap on electrical outlet on aft cat room bulkhead.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 16 April 2010
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 25 March 2010
Resolved
Install "A" class windows in cat room bulkheads. Fire Control Plan shows this is an "A" class bulkhead. The windows have an aluminum frame and no evidence of fire rating can be provided. Dredge rep indicated GLDD will remove them and make steel inserts next dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2011
Resolved 12 January 2011
Resolution: Windows have been removed and steel inserts were welded in place.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 March 2010
Resolved
Port pump generator sea water cooling pump pack is leaking.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 16 April 2010
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 March 2010
Resolved
Clean excessive oil under mains in engine room bilge.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 16 April 2010
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 March 2010
Resolved
Repair or replace fuel valve packing and transfer pump at fuel transfer station.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 25 March 2010
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 25 March 2010
Resolved
Crop and renew wasted sewage lines and clean and inspect sewage tank at nex credit drydock.
Action required: 705 - Other - as specified
Due 1 February 2011
Resolved 12 January 2011
Resolution: MSD system has been replaced with new and wasted pipes have been renewed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 10 May 2008
Resolved
Properly service three halon bottles that are low and require hydrostatic testing.
Condition: Unknown
Due 16 June 2008
Resolved 15 January 2009
Resolution: Item previous closed out in MISLE Act# 3198968
Fire Fighting › Fire Hoses › Condition
Issued 10 May 2008
Resolved
Provide one 2.5 in fire hose as required by COI
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2008
Resolved
Inspect all wiring. Numerous areas need proper installation removal of wire nuts, junction boxes etc.
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 10 May 2008
Resolved
Prove proper operation of bunk lights in engineers quarters. install proper wiring in overhead.
Prove proper operation of all bunk lights in levermans quarters.
repair light in crew room #1
repair overhead in crew room
repair deck in crew room #5 and install proper wiring
provide light cover in crew room #6
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 10 May 2008
Resolved
Provide proper lifejacket lights for emergency life jackets on 02 deck.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Engineering › Bilge Water Management System › Pump
Issued 10 May 2008
Resolved
Prove proper operation of vessels bilge system
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Engineering › Lubricating Oil Service System › Hose
Issued 10 May 2008
Resolved
Renew packing line on main pump in the pump hole
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 10 May 2008
Resolved
Install all light covers that are missing throughout the vessel.
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 May 2008
Resolved
Properly mount motor on MSD and repair leak in stanitation pipes.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Construction/Loadline › Structures › Deck Plating
Issued 10 May 2008
Resolved
Renew wasted frames that brace the hatch lifting beam for rock box cover in pump hole.
Condition: Improper/Lack of Maintenance
Due 1 January 2009
Resolved 12 June 2008
Construction/Loadline › Structures › Deck Plating
Issued 10 May 2008
Resolved
Identify all wasted frames and deck plates throughout the vessel to be repaired during hull inspection.
Condition: Improper/Lack of Maintenance
Due 31 January 2009
Resolved 15 January 2009
Resolution: Item previous closed out in MISLE Act# 3198968
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2008
Resolved
Provide guards on slop tank oil pump.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 May 2008
Resolved
Prove proper operation of MSD.
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 May 2008
Resolved
Renew safety cage on ladder above the spud A frame aft deck.
Condition: Damaged By Earlier Event
Due 16 June 2008
Resolved 12 June 2008
Engineering › Lubricating Oil Service System › Pump
Issued 10 May 2008
Resolved
Prove proper operation of lube pump for cutter gear box, excessive hydralic fluid.
Condition: Improper/Lack of Maintenance
Due 16 June 2008
Resolved 12 June 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 10 May 2008
Resolved
Install directions for operation for halon system remote pulls.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 May 2008
Resolved
Provide directions for proper operation of the CO@ system.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 May 2008
Resolved
Repair reach rod visual indicators on all emergency fuel shut offs.
Condition: Damaged By Earlier Event
Due 16 June 2008
Resolved 12 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 May 2008
Resolved
Provide certificates from unitor for servicing of Fixed fire fighting systems
Due 16 June 2008
Resolved 12 June 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 May 2008
Resolved
Inspect all breaker boxes and ensure proper labeling of breakers.
Due 16 June 2008
Resolved 12 June 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 May 2008
Resolved
Properly install and prove proper operation of bilge alarms.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Construction/Loadline › Structures › Deck Plating
Issued 10 May 2008
Resolved
Properly repair the upper aft deck off spud room. Personnel are not allowed until proper repairs are completed.
Condition: Improper/Lack of Maintenance
Due 18 June 2008
Resolved 12 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2008
Resolved
Properly mount guard on pump for barge water service.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2008
Resolved
Properly wire fuel gauges on port generators.
Condition: Improper Installation
Due 16 June 2008
Resolved 12 June 2008
Documentation › Certificates/Documents › IOPP Certificate
Issued 10 May 2008
Resolved
Submit for IOPP as per regulations.
Due 16 June 2008
Resolved 12 June 2008
Communications › Radio Communications › EPIRB
Issued 17 January 2007
Resolved
Hydro out of date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2007
Lifesaving › Rescue Boat › Carriage Requirement
Issued 13 January 2006
Resolved
Provide rescue boat, demonstrate launching and recovery operations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 29 January 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 13 January 2006
Resolved
Install turbo charger exhaust lagging blankets
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 29 January 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 January 2006
Resolved
Provide updated Fire and Safety plan for approval.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 29 January 2007
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 18 March 2005
Resolved
Provide closure device for watermaker controller boxes
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 1 April 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 18 March 2005
Resolved
Clean engineroom ventilation ducting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 28 June 2005
Resolution: Attended vessel cleared
Accommodation/Occupational Safety › Ventilation › General
Issued 18 March 2005
Resolved
Replace inoperative engineroom exhaust fans
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 28 June 2005
Resolution: Attended vessel cleard
Lifesaving › Inflatable Liferafts › Float Free
Issued 18 March 2005
Resolved
Properly install liferaft sea painters per manufactures instruction
Condition: Improper Installation
Due 18 March 2005
Resolved 18 March 2005
Resolution: Corrected on scene
Communications › Radio Communications › EPIRB
Issued 18 March 2005
Resolved
Provide float free EPIRB IAW 46CFR199.510
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 1 April 2005
Lifesaving › Inflatable Liferafts › Capacity
Issued 18 March 2005
Resolved
Provide liferafts on each side of the vessel with an aggregate capacity to accomodate the total number of persons on board (41 persons). 46CFR199.10(h)(1)(ii); 199.261(b)(2)
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 1 April 2005
Communications › Radio Communications › EPIRB
Issued 18 March 2005
Resolved
Provide current registration for EPIRB
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 4 April 2005
Engineering › Fuel Oil Service System › Filter
Issued 17 March 2005
Resolved
Provide flame impingement/drip pans under fuel filters. 46 CFR 56.50-75
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 1 April 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 17 March 2005
Resolved
Remove oil from bilges and clean.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 28 June 2005
Resolution: Attened vessel cleared
Lifesaving › Lifebuoys › Stowage
Issued 6 February 2004
Resolved
Properly mount all lifebouys
Due 6 February 2004
Resolved 6 February 2004
Resolution: Item corrected prior to completion of yard period.
Lifesaving › Visual Distress Signals (General)
Issued 6 February 2004
Resolved
properly install all waterlight to lifebouys w/ 3-6 foot lanyard
Due 6 February 2004
Resolved 6 February 2004
Construction/Loadline › Structures › Door
Issued 6 February 2004
Resolved
Prove proper operation of auxilary generator room aft port access door, specifically show that it will close completely.
Due 6 February 2004
Resolved 6 February 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2004
Resolved
properly install starboard lifefloat light fixture junction box
Condition: Improper Installation
Due 6 February 2004
Resolved 6 February 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2004
Resolved
Properly install starboard spud flood light junction box and light.
Condition: Improper Installation
Due 6 February 2004
Resolved 6 February 2004
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 6 February 2004
Resolved
install blank in electrical distribution panel L3.
Due 6 February 2004
Resolved 6 February 2004
Engineering › Reduction Gearing/Clutches › Bearing, Line Shaft
Issued 6 February 2004
Resolved
make proper repairs to the machinery guard on the main pump drive in the pump room.
Due 6 February 2004
Resolved 6 February 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2004
Resolved
Properly secure dead end wiring in various locations in the engine room, 02 deck area and pump room.
Due 6 February 2004
Resolved 6 February 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 23 January 2003
Resolved
SHOW PROOF OF SERVICING FOR THE 3 HALON STORAGE TANKS WHICH TESTED UNSATISFACTORILY.
LEGACY COMPONENT DESC: Tanks
Due 13 February 2003
Resolved 5 February 2003
Resolution: Cylinders renewed.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 23 January 2003
Resolved
PROVIDE AND POST UP TO DATE FIRE CONTROL PLAN.
LEGACY COMPONENT DESC: FIRE CONTROL PLAN
Condition: Unknown
Due 31 August 2004
Resolved 31 July 2004
Pollution Prevention/Response
Issued 23 January 2003
Resolved
CLEAN ALL OIL AND DEBRIS FROM ALL BILGES IN MACHINERY SPACES.
Due 13 February 2003
Resolved 5 February 2003
Resolution: Bilges cleaned.
Electrical › Electric Generation Source (emergency)
Issued 23 January 2003
Resolved
SHOW PROPER OPERATION OF EMERGENCY GENERATOR AND EMERGENCY LIGHTING.
LEGACY COMPONENT DESC: Generator
Due 13 February 2003
Resolved 5 February 2003
Resolution: Sat operation of generator and lighting.
Electrical › Electric Supply System (service)
Issued 23 January 2003
Resolved
PROVIDE AND INSTALL STRAIN RELIEF DEVICES ON WIRING SERVING HOT WATER HEATERS.
LEGACY COMPONENT DESC: Cable
Due 13 February 2003
Resolved 5 February 2003
Resolution: Strain relief devices installed.
Navigation › Collision/Grounding Avoidance
Issued 23 January 2003
Resolved
SHOW PROPER OPERATION OF NAV LIGHTS.
LEGACY COMPONENT DESC: Navigation Lights
Due 13 February 2003
Resolved 5 February 2003
Documentation › Certificates/Documents
Issued 23 January 2003
Resolved
SHOW COMPLIANCE WITH CG DRUG TESTING REGS.
LEGACY COMPONENT DESC: Letter of Substantial Compliance (DAPI)
Condition: Unknown
Due 13 February 2003
Resolved 27 February 2003
Resolution: Rec''''d fax copy of Certificate of Compliance from American Maritime Safety, Inc. (consortium) showing dredge TEXAS is enrolled w/them.
Lifesaving › Rescue Boat
Issued 23 January 2003
Resolved
SHOW PROPER OPERATION OF OUTBOARD MOTOR SERVING RESCUE BOAT. LEGACY COMPONENT DESC: Propulsion Engine
Due 13 February 2003
Resolved 28 February 2003
Operations/Management › Equipment Service/Testing
Issued 17 July 2002
Resolved
Dredge suffered lube oil spills on 15/17Jul02 due to failure in ladder cutter reduction gear box.Operator required to provide documentation of originating/propigating causes of casualty,provide repair(permanent) proposal & conduct an ops test after repairs completed. Dredge ops secured until SAT.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2002
Resolved 24 July 2002
Construction/Loadline › Hull › Hull Plating
Issued 20 February 2002
Resolved
Void / port #2 from the main deck down six feet and ten feet forward of the aft bulkhead and void / port #3 from the main deck down six feet and ten feet aft of the forward bulkhead had damage from earlier tug collision.
Condition: Damaged By Earlier Event
Due 8 March 2002
Resolved 7 March 2002
Resolution: Port voids #2 & #3 - C&R 1-1/2'' x 8-1/2'' x 1/2" deck plate and 7'' x 20'' x 1/2" shell plate vicinity of above damage. C&R all longs and gussets IWO deck plate and shell plate being replaced.
Construction/Loadline › Hull
Issued 20 February 2002
Resolved
Void #6 port - All inboard ladder rungs fractured. LEGACY COMPONENT DESC: Weld
Condition: Improper Installation
Due 8 March 2002
Resolved 7 March 2002
Resolution: Re-aligned ladder and re-welded rungs.
Personnel › Training
Issued 21 December 2000
Resolved
Conduct fire drill and man overboard drill to the satisfaction of the attending Marine Inspector LEGACY COMPONENT DESC: Fire Fighting Basic
Condition: Unknown
Due 21 January 2001
Resolved 7 March 2002
Resolution: Conducted drills.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 21 December 2000
Resolved
Provide test report for hydrostatic testing of fuel oil transfer hoses in accordance with 33 CFR 156.170.
Condition: Unknown
Due 21 January 2001
Resolved 7 March 2002
Resolution: Test report provided.
Pollution Prevention/Response › Prevention Equipment
Issued 21 December 2000
Resolved
Provide standard discharge connection in accordance with 33 CFR 155.430. LEGACY COMPONENT DESC: Standard Discharge Connection
Condition: Unknown
Due 21 January 2001
Resolved 7 March 2002
Resolution: Witnessed connection.
Lifesaving
Issued 20 May 1998
Resolved
PROVIDE OUTBOARD MOTOR FOR RESCUE BOAT AS REQUIRED BY 46 CFR 94.10-5(e) ANDUSCG MARINE SAFETY MANUAL VOLUMN II CHAPTER 18.H.3.C(2).
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Fire Fighting
Issued 30 March 1998
Resolved
REFILL/REPLACE UNDERPRESSURED HALON CYLINDERS AND COMPLETE ANNUAL SERVICINGOF THE MAIN AND AUXILIARY MACHINERY SPACE FIXED FIRE EXTINGUISHING SYSTEMS PRIOR TO THE VESSEL'S DEPARTURE FROM THE PORT OF GREEN COVE SPRINGS, FLORIDA.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Accommodation/Occupational Safety
Issued 30 March 1998
Resolved
REPLACE/ADJUST 125 PSI RELIEF VALVE ON THE AUXILIARY GENERATOR START AIR RECEIVER AND RETEST IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO THE VESSEL'S DEPARTURE FROM THE PORT OF GREEN COVE SPRINGS, FLORIDA.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Deck/Cargo
Issued 30 March 1998
Resolved
REPLACE MISSING FLANGE COUPLING GUARD ON THE MAIN DREDGE PUMP.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Electrical
Issued 30 March 1998
Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER RELAYS ON GENERATORS NUMBER 2 &3 IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO THE VESSEL'S DEPART- URE FROM THE PORT OF GREEN COVE SPRINGS, FLORIDA.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Electrical
Issued 30 March 1998
Resolved
CONDUCT ALL REQUIRED SAFETY TESTS ON THE COOPER BESSEMER PRIME MOVER OR DISCONNECT THE FUEL AND AIR START PIPING LINES IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO THE VESSEL'S DEPARTURE FROM THE PORT OF GREEN COVE SPRINGS, FLORIDA.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Lifesaving
Issued 30 March 1998
Resolved
REPLACE DETERIORATED RESCUE BOAT DAVIT COMPONENTS INCLUDING THE DAVIT ARM PINS, 6 BLOCKS, BLOCK MOUNTING SHACKLES, FALLS CABLES AND WINCHES AND REMOVE RUST FROM DAVIT ARMS TO DETERMINE CONDITION. EXERCISE RESCUE BOAT IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO THE VESSEL'S DEPARTURE.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Engineering
Issued 30 April 1997
Resolved
Make repairs to oily water separator to the satisfaction of the attending CG marine inspector.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Lifesaving
Issued 30 April 1997
Resolved
Provide primary lifesaving equipment, serviced and ready for inspection by CG Inspector.
Condition: Unknown
Due 7 May 1997
Resolved 9 May 1997
Construction/Loadline
Issued 30 April 1997
Resolved
Replace all cracked glass as necessary on 01 deck.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Fire Fighting
Issued 30 April 1997
Resolved
Provide necessary repairs to the Fixed Halon system for Engine Room and test in presence of attending CG Inspector.
Condition: Unknown
Due 7 May 1997
Resolved 9 May 1997
Documentation
Issued 20 June 1995
Resolved
PROVIDE TO THE USCG MARINE SAFETY CENTER AMENDED STABILITY DATA FOR THE JETPUMP INSTALLATION INCLUDING PIPING, FITTINGS, MOTORS, AND WIRING; THE REPLACEMENT SHIP SERVICE GENERATOR; THE NEW EMERGENCY GENERATOR UNIT; AND THE COE OFFICE TRAILER AND THE BARGE TRAILER.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Electrical
Issued 20 June 1995
Resolved
INSTALL METAL CABLE BANDS IN WAY OF NEWLY INSTALLED JET PUMP MOTORS TO THE CONNECTION BOX CONTROL PANELS. BANDS TO BE MINIMUM 1/2 INCH WIDE METAL.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Fire Fighting
Issued 13 December 1993
Resolved
PROVIDE MISSING HALON BOTTLE FOR AUXILIARY MACHINERY SPACE. UNTIL REPLACED HOURLY ROUND FOR FIRE TO BE CONDUCTED AND LOGGED.
Condition: Unknown
Due 20 December 1993
Resolved 23 December 1993
Fire Fighting
Issued 13 December 1993
Resolved
CONDUCT HYDO TEST OF HALON BOTTLE FOR AUX. MACHINERY SPACE SERIAL #22419EK.WHILE BOTTLE IS OFF VESSEL FIRE WATCH IS TO BE MAINTAINED ON SPACE AT LEASTONCE A HOUR AND LOGGED.
Condition: Unknown
Due 5 January 1994
Resolved 4 January 1994
Fire Fighting
Issued 13 December 1993
Resolved
PROVIDE VENTALATION SHUTDOWN TIED INTO FIRE SYSTEM SHUTDOWN FOR CUTTING MOTOR COOLING MOTOR COOLING FAN.
Condition: Unknown
Due 23 December 1993
Resolved 23 December 1993
Engineering
Issued 13 December 1993
Resolved
PROVIDE INSULATION FOR BOTH AUX GENATORS TUBO CHARGERS AND EXHAUST PIPING.
Condition: Unknown
Due 23 December 1993
Resolved 23 December 1993
Fire Fighting
Issued 13 December 1993
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR FIXED CO2 SYSTEM FOR PAINT LOCKER.
Condition: Unknown
Due 20 December 1993
Resolved 23 December 1993
Documentation
Issued 1 April 1993
Resolved
MAINTAIN DAILY SOUNDING LOG OF PORT DREDGE END VOID UNTIL COMPLETION OF PERMANENT REPAIR IN WAY OF TEMP PATCHED HOLE AT NEXT CREDIT DRYDOCK.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Documentation
Issued 1 April 1993
Resolved
VESSEL FAILED TO COMPLY WITH THE CONDITIONS OF ITS CERTIFICATE OF INSPECTION BY NOT HAVING THE VESSEL'S INTERNAL STRUCTURAL HULL EXAMINATION CONDUCTED.
Condition: Unknown
Due 1 April 1993
Resolved 6 April 1993
Fire Fighting
Issued 10 March 1993
Resolved
CONDUCT A FIRE AND ABANDON SHIP DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Documentation
Issued 10 March 1993
Resolved
PROVIDE CREW CABIN NOTICES.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Construction/Loadline
Issued 10 March 1993
Resolved
PAINT HULL MARKINGS, HAILING PORT, OFFICIAL NUMBER, AND NAME.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Documentation
Issued 10 March 1993
Resolved
OBTAIN COPIES OF 46 CFR SUBCHAPTER I AND E.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Fire Fighting
Issued 10 March 1993
Resolved
PROVIDE CLOSURES FOR SPACES PROTECTED BY FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Accommodation/Occupational Safety
Issued 10 March 1993
Resolved
PROVIDE COAST GUARD APPROVAL NUMBER FOR MARINE SANITATION DEVICE.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Engineering
Issued 10 March 1993
Resolved
PROVE PROPER OPERATION OF OIL WATER SEPERATOR.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Construction/Loadline
Issued 10 March 1993
Resolved
MAKE VESSEL AVAILABLE FOR INTERNAL EXAM INCLUDING FUEL TANK , NOT LATER THAN 31 MAR 93.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Engineering
Issued 10 March 1993
Resolved
REPAIR FUEL LEAKS ON COOPER GENERATOR HAND PRIMING PUMP.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Electrical
Issued 10 March 1993
Resolved
PROVE PROPER OPERATION OF KILOWATT METER ON NUMBER 2 SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 31 March 1993
Resolved 11 March 1993
Documentation
Issued 10 March 1993
Resolved
MAKE PROPER ENTRIES IN OIL RECORD BOOK.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Documentation
Issued 10 March 1993
Resolved
POST POLLUTION PLACARD IN MACHINERY SPACE.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Engineering
Issued 10 March 1993
Resolved
PROVIDE STOP BUTTON FOR DIRTY L/O PUMP AT MAIN DECK DISCHARGE STATION.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Electrical
Issued 10 March 1993
Resolved
PROVIDE COVER FOR PORT AFT SHORE TIE CONNECTION.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Documentation
Issued 10 March 1993
Resolved
MAINTAIN COPIES OF DAILY LOG SHEETS ONBOARD VESSEL.
Condition: Unknown
Due 31 March 1993
Resolved 25 March 1993
Unknown
Issued 1 February 1990
Resolved
REMEASURE VESSEL AND ADJUST TONNAGE AS NECESSARY AS PER 46 CFR 69.01-15(A)-(C).
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Fire Fighting
Issued 12 January 1990
Resolved
REPAIR AND PROVE OPERATION OF FIXED HALON SYSTEM TO EMERGENCY GENERATOR ROOM TO SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR. UNTIL FIXEDHALON SYSTEM IS REPAIRED INSTALL ONE(1) B-II PORTABLE EXTINGUISHER IN VICINITY OF EACH FORWARD EXIT FOR MINIMUM OF TWO. 46 CFR 91.25-20(A)(2)
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Engineering
Issued 12 January 1990
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR. 33 CFR 155.380(A)
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Lifesaving
Issued 12 January 1990
Resolved
CONDUCT FIRE AND BOAT DRILL IN PRESENCE OF COAST GUARD MARINE INSPECTOR. 46 CFR 97.15-35
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Construction/Loadline
Issued 10 February 1987
Resolved
REMOVE ALL ANTENNAE FROM THE STATEROOM PORT LIGHTS.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Construction/Loadline
Issued 10 February 1987
Resolved
MAKE REPAIRS TO THE ESCAPE DOOR FROM THE CONTROL ROOM FOR THE ENGINEROOM TO MAKE PROPERLY OPERABLE.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Fire Fighting
Issued 25 February 1986
Resolved
MAKE REPAIR TO INSTALL THEMAL LINKS AND SPRINGS IN ALL VENTS FOR ENGINE ROOM AND PROVE OPERATION WITH INSTALLED HALON SYSTEM AS PER ORIGINAL PLANS AS BUILD.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 25 February 1986
Resolved
PROVIDE OIL RECORD BOOK, AND 100 RPM OIL WATER SEPORATOR (USCG APPROVED) AND HAVE IOPP SURVEY COMPLETED AS PER 33CFR151.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Fire Fighting
Issued 25 February 1986
Resolved
PROVIDE POSITIVE MEANS OF CLOSING ALL VENTS ON INSTALLED PAINT LOCKER AS PER 46 CFR 95.15-35.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Unknown
Issued 23 March 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL BILL JAMES, DN627368.
Condition: Unknown
Due 23 March 1983
Resolved 23 March 1983
Electrical
Issued 23 March 1983
Resolved
SUBMIT PLANS TO CCGD8(MMT) AND OBTAIN APPROVAL ON THE ALTERATIONS MADE TO VESSELS 4160V POWER A/C SYSTEM.
Condition: Unknown
Due 23 March 1983
Resolved 23 March 1983