Records from 1984 to 2017. Most recent: inspection, 19 September 2017.
Inspection history · 50
19 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6270455
12 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6173421
28 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5013916
8 August 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4948493
4 August 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4943682
10 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4811739
27 July 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4396148
8 June 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4343089
27 January 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4235239
28 December 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4215404
19 July 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4089468
1 July 2009
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3521116
18 September 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330821
28 July 2008
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3281806
15 February 2008
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147985
4 June 2007
Cargo Tank Internal · Hull Examination · Internal Structural Exam · Damage Survey · Re-Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2951020
25 August 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3199422
25 May 2006
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2658389
8 June 2005
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2378149
14 April 2005
Examination of Repairs · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2333954
18 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2102705
12 May 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2066016
8 April 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2040201
13 February 2004
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2006200
13 February 2004
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2006213
6 October 2003
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1922431
11 September 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1906873
29 May 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1804575
25 March 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1597258
9 April 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062936
27 March 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472054
29 March 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438996
14 April 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427634
21 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 647654
17 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 93140
16 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 170689
16 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 191494
16 November 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393019
6 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 113607
13 March 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106328
2 March 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436053
5 March 1992
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1008693
1 December 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318514
2 November 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019892
25 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334838
26 October 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325531
1 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979855
16 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283915
13 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976758
13 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286258
Lifesaving › Lifebuoys › Serviceable
Issued 10 March 2014
Resolved
Renew retro reflective tape on 3 ring buoys
Action required: 705 - Other - as specified
Resolved 13 March 2014
Lifesaving › Inflatable Liferafts › Painter
Issued 10 March 2014
Resolved
Attach painter to liferafts
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2014
Fire Fighting › Firemans Outfit › Axe
Issued 10 March 2014
Resolved
Fire axe broken
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2014
Resolution: Replaced before inspection complete
Documentation › Markings/Placards › Garbage Placard
Issued 10 March 2014
Resolved
Update to new MARPOL V placard
Action required: 705 - Other - as specified
Resolved 13 March 2014
Engineering › Steering Gear System › Valve, Control
Issued 10 March 2014
Resolved
Repair hydraulic leaks on control valve block in E/R
Action required: 705 - Other - as specified
Resolved 13 March 2014
Resolution: Recieved email w/ photo from vsl rep attesting to repairs
Construction/Loadline › Hull › Hull Plating
Issued 1 July 2009
Resolved
Prior to operation, make vessel available on drydock for a complete USCG Hull inspection.
Action required: 705 - Other - as specified
Resolved 26 February 2010
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 September 2008
Resolved
Make operable all extinguished "E" lights.
Due 18 October 2008
Resolved 23 September 2008
Resolution: All "E" lights operational
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 18 September 2008
Resolved
Provide current local notice to mariners.
Due 18 October 2008
Resolved 23 September 2008
Resolution: Current N.T.M.''s on board vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 18 September 2008
Resolved
Provide current or updated navigational charts.
Due 18 October 2008
Resolved 23 September 2008
Resolution: Curent and updated charts were made available.
Communications › Audible Communications › Horn/Whistle
Issued 18 September 2008
Resolved
Make operable the vessel's horn.
Due 18 October 2008
Resolved 23 September 2008
Resolution: Ship''s horn functions properly.
Lifesaving › Lifebuoys › Serviceable
Issued 18 September 2008
Resolved
Replace portside aft life bouy [holed].
Due 18 October 2008
Resolved 18 September 2008
Resolution: Resolved prior to the M.I.''s departure.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 September 2008
Resolved
Place current C.O.D. on vessel,
Due 18 October 2008
Resolved 18 September 2008
Resolution: Copy placed on vessel prior to M.I.''s departure.
Lifesaving › Lifefloat › Serviceable
Issued 28 July 2008
Resolved
Vessel was operating with expired life rafts
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2008
Resolved 28 July 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 July 2008
Resolved
Vessel failed to maintain compliance with their automation test procedures. Requied to provide automation test report prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 June 2007
Resolved
Vsl not manned in accordance with COI
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 June 2007
Resolved
provide
Due 22 July 2007
Resolved 4 June 2007
Navigation › Piloting/Steering › Compass Deviation Table
Issued 4 June 2007
Resolved
provide and post
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 4 June 2007
Resolved
provide
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 June 2007
Resolved
provide
Due 22 July 2007
Resolved 4 June 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 June 2007
Resolved
provide
Due 22 July 2007
Resolved 4 June 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 June 2007
Resolved
Provide Lifesaving Equipment Maintenance Record
Due 22 July 2007
Resolved 4 June 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2007
Resolved
demonstrate proper operation of nav light power panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 4 June 2007
Resolved
provide documentation of last liferaft servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 4 June 2007
Resolved
Indicate expiration of all hydrostatic releases.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Engineering › Fuel Oil Service System › Valve
Issued 4 June 2007
Resolved
permanently close sight glass valve for starboard fuel tank where sight glass is not installed to prevent fuel spill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Fire Fighting › Self-contained Breathing Apparatus › Approval
Issued 4 June 2007
Resolved
re-certify EEBDs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Electrical › Electric Generation Source (service) › Generator
Issued 4 June 2007
Resolved
provide mat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 4 June 2007
Resolved
demonstrate proper operation of main engine shut downs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2007
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 25 May 2006
Resolved
Provide Chief engineer and full manning prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Provided a chief engineer and full manning.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 May 2006
Resolved
Provide current light list and tide/currant tables
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Provided updated items.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 25 May 2006
Resolved
Provide compas deviation table
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Provided table.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 May 2006
Resolved
Demonstrate proper operation of SSB .
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Demonstrated proper operation of SSB
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2006
Resolved
Provide and display life jacket donning placard throughout vsl as discussed.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Displayed donning placards.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 25 May 2006
Resolved
Inspect and log monthly harness inspections
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 27 May 2006
Resolution: Completed.
Engineering › Fuel Oil Service System › Valve
Issued 25 May 2006
Resolved
Label all fuel oil valves at transfer pump.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 27 May 2006
Resolution: All valves labeled.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 25 May 2006
Resolved
Stencil engine room exits and paint draft marks prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Completed.
Communications › Alarms/Indicators › General Alarm
Issued 25 May 2006
Resolved
Demonstrate general alarm light ooperation on final power
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 27 May 2006
Resolution: General alarm operational.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 25 May 2006
Resolved
Complete general markings on all systems.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: All complete.
Engineering › Bilge Water Management System › Vent
Issued 25 May 2006
Resolved
Renew starboard vent
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Renewed vent.
Fire Fighting › Fire Hydrants › Material
Issued 25 May 2006
Resolved
Renew fire station spanner and stencil station.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 27 May 2006
Resolution: Complete
Stability › Watertight Integrity
Issued 8 April 2004
Resolved
Make repairs to the aft bulkhead of the No. 1 port ballast tank. LEGACY COMPONENT DESC: Watertight Bulkhead
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2004
Resolved 15 April 2004
Navigation › Piloting/Steering
Issued 8 April 2004
Resolved
Provide the vessel with a compass deviaition table. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 15 April 2004
Communications › Alarms/Indicators
Issued 8 April 2004
Resolved
Repair both main engine shaft tachs. in the pilothouse. LEGACY COMPONENT DESC: Rate of Turn Indicator
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 15 April 2004
Electrical › Electrical Distribution System (service)
Issued 8 April 2004
Resolved
Provide an appropriate rubber mat for the deck in front of the switchboard. LEGACY COMPONENT DESC: Switchboard
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2004
Resolved 15 April 2004
Deck/Cargo › Vapor Control Systems
Issued 8 April 2004
Resolved
Replace the vents on (9) vents on the main deck. LEGACY COMPONENT DESC: Flame Screens
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2004
Resolved 15 April 2004
Fire Fighting › Grease Extraction Hood
Issued 8 April 2004
Resolved
Provide a light cover for the range hood. LEGACY COMPONENT DESC: Light Cover
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 15 April 2004
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 13 February 2004
Resolved
Failure to submit vessel security assesssment report.
Action required: 705 - Other - as specified
Resolved 1 July 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 May 2003
Resolved
Provide 2003 Light List prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2003
Resolved 29 May 2003
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 29 May 2003
Resolved
Provide notice to mariners.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2003
Resolved 29 May 2003
Lifesaving › Embarkation Appliances/Stations
Issued 29 May 2003
Resolved
Properly stencil vessel name on stokes litter basket. LEGACY COMPONENT DESC: Rescue Basket
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2003
Resolved 29 May 2003
Personnel › Manning/Qualifications
Issued 14 March 2002
Resolved
MISSING 1 LICENSED MATE AND 1 OILER. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2002
Resolved 2 April 2002
Operations/Management › Vessel Safety Management
Issued 14 March 2002
Resolved
AUTOMATION TEST PROCEDURES NOT COMPLETED. LEGACY COMPONENT DESC: AUTOMATION TEST PROCEDURES
Due 2 April 2002
Resolved 2 April 2002
Documentation › Logs/Records
Issued 14 March 2002
Resolved
PRE UNDERWAY CHECKS AND MONTHLY EPIRB TESTS NOT CONDUCTED AND LOGGED. LEGACY COMPONENT DESC: PRE UNDERWAY CHECKS
Due 2 April 2002
Resolved 2 April 2002
Communications › Audible Communications
Issued 14 March 2002
Resolved
SHIPS HORN INOPERABLE. LEGACY COMPONENT DESC: Horn/Whistle
Due 2 April 2002
Resolved 2 April 2002
Lifesaving › Inflatable Liferafts
Issued 14 March 2002
Resolved
LIFERAFTS NOT INSTALLED.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2002
Resolved 2 April 2002
Fire Fighting › Fixed Fire Detection System
Issued 14 March 2002
Resolved
SMOKE DETECTORS INOPERABLE. LEGACY COMPONENT DESC: Smoke Detectors
Due 2 April 2002
Resolved 2 April 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 14 March 2002
Resolved
RANGE LIGHT GUARD MISSING. LEGACY COMPONENT DESC: RANGE LIGHT GUARD
Due 2 April 2002
Resolved 2 April 2002
Engineering › Fuel Oil Service System
Issued 14 March 2002
Resolved
FUEL AND LUBE OIL HOSES ON ALL DIESEL ENGINES CHAFFING AGAINST FRAMES. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2002
Resolved 2 April 2002
Stability › Watertight Integrity
Issued 14 March 2002
Resolved
WATERTIGHT DOORS OUT OF ADJUSTMENT. LEGACY COMPONENT DESC: DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2002
Resolved 2 April 2002
Engineering › Fuel Oil Service System
Issued 14 March 2002
Resolved
FUEL OIL SERVICE PUMP METER MISSING. LEGACY COMPONENT DESC: METER
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2002
Resolved 2 April 2002
Electrical › Electrical Distribution System (service)
Issued 14 March 2002
Resolved
MAIN SWITCHBOARD NOT FUNCTIONING PROPERLY. LEGACY COMPONENT DESC: Switchboard
Due 2 April 2002
Resolved 2 April 2002
Engineering › Shafting/Propeller Arrangements
Issued 14 March 2002
Resolved
NO SHAFT GUARDS INSTALLED. LEGACY COMPONENT DESC: GUARDS
Condition: Design Flaw
Due 2 April 2002
Resolved 2 April 2002
Engineering › Fuel Oil Service System
Issued 14 March 2002
Resolved
IMPROPER SIGHT GLASS INSTALLED ON FUEL OIL STORAGE TANKS. LEGACY COMPONENT DESC: SIGHT GLASS
Due 2 April 2002
Resolved 2 April 2002
Communications › Visual Communication
Issued 14 March 2002
Resolved
ENGINE ROOM CALL PHONE NOT WIRED TO EMERGENCY POWER. LEGACY COMPONENT DESC: ENGINE ROOM PHONE
Condition: Improper Installation
Due 2 April 2002
Resolved 2 April 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 14 March 2002
Resolved
CARGO TRANSFER HOSES WORN AND OUT OF DATE. LEGACY COMPONENT DESC: Transfer Hose
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2002
Resolved 2 April 2002
Deck/Cargo › Cargo Stowage
Issued 14 March 2002
Resolved
LIQUID MUD AND FUEL OIL STORAGE TANKS MISSING FLAME SCREENS. LEGACY COMPONENT DESC: VENTS
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2002
Resolved 2 April 2002
Stability › Watertight Integrity
Issued 14 March 2002
Resolved
PORT ENGINE ROOM WATER TIGHT DOOR MISSING DOGGING WRENCH. LEGACY COMPONENT DESC: WATER TIGHT DOOR DOGGING WRENCH
Due 2 April 2002
Resolved 2 April 2002
Electrical › Electrical Distribution System (service)
Issued 14 March 2002
Resolved
LOOSE WIRING ON STARBOARD DECK LOCKER LIGHTING SWITCH AND STARBOARD MAIN ELECTRICAL BOX. LEGACY COMPONENT DESC: Cable
Due 2 April 2002
Resolved 2 April 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 14 March 2002
Resolved
CO2 FIRE EXTINGUISHER IN STARBOARD SIDE DECK LOCKER NOT SERVICED. LEGACY COMPONENT DESC: Service
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2002
Resolved 2 April 2002
Lifesaving
Issued 27 March 2001
Resolved
DEMONSTRATE PROPER OPERATION OF THE BILGE / MAIN ENGINE ALARM CIRCUIT TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 April 2001
Resolved 10 April 2001
Electrical
Issued 27 March 2001
Resolved
DEMONSTRATE PROPER OPERATION OF THE MAIN DISTRIBUTION SWITCHBOARD GROUND DETECTION SYSTEM TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 April 2001
Resolved 10 April 2001
Construction/Loadline
Issued 27 March 2001
Resolved
MAKE PERMANENT REPAIRS TO PORT STERN WRAP, INCLUDING THE MAIN DECK, GUNWALE, AND ASSOCIATED FRAMING IN WAY OF THE STERN WRAP, TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 April 2001
Resolved 10 April 2001
Construction/Loadline
Issued 16 November 1998
Resolved
Vessel to proceed directly from [name withheld], Fourchon LA to Bollingers S/Y,Larose, LA, to effect permanent repairs to damaged area on port side, midbody, approx 06ft draft. Make area available for USCG Inspection and provide repair proposal.
Condition: Unknown
Due 30 November 1998
Resolved 7 December 1998
Lifesaving
Issued 2 March 1998
Resolved
Prior to vessel ops, conduct Fire, man overboard, and abandon ship drill with full crew onboard.
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Lifesaving
Issued 25 October 1987
Resolved
COMPLETE REPAIRS/DEFICIENCIES ON REQUIIIIREMENT LIST DTD 20OCT87 WITH 66 ITEMS OUTSTANDING.
Condition: Unknown
Due 25 October 1987
Resolved 25 October 1987
Unknown
Issued 16 January 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL BRAZOS EXPRESS.
Condition: Unknown
Due 16 January 1985
Resolved 16 January 1985
Deck/Cargo
Issued 16 January 1985
Resolved
PROVIDE APPROVAL OF INSTALLED ACID TANKS OR COAST GUARD APPROVED ACID TANKS
Condition: Unknown
Due 16 January 1985
Resolved 16 January 1985
Unknown
Issued 13 November 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, BRAZOS EXPRESS, DN652318
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Deck/Cargo
Issued 13 November 1984
Resolved
PROVIDE APPROVAL OF INSTALLED ACID TANKS OR COAST GUARD APPROVED ACID TANKS.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Lifesaving
Issued 13 November 1984
Resolved
HAVE INFLATABLE RAFTS SERVICED AT APPROVED FACILITIES OR PROVIDE SERVICED RAFTS NO LATER THAN 13DEC84.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984