Records from 1986 to 2026. Most recent: inspection, 14 May 2026.
Inspection history · 76
14 May 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8373283
28 February 2026
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8314587
13 June 2025
MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8157276
26 March 2024
MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7879646
12 June 2023
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7713523
21 April 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7681818
7 February 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7636279
28 June 2022
Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7482535
4 June 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7468334
27 November 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7357931
17 February 2021
Drydock Exam · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134363
19 May 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6956021
26 March 2019
Cargo Tank Internal · COI Inspection · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6649841
15 March 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6643476
17 August 2018
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6518771
13 March 2018
Internal Structural Exam · Damage Survey · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6370814
3 January 2018
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6330257
30 October 2017
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6302906
6 April 2016
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5848353
29 February 2016
Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5824886
23 December 2015
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5786532
3 December 2014
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5025243
5 May 2014
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4854666
10 March 2014
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4809942
11 December 2013
In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4676139
11 December 2013
In-Service Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4768219
30 July 2013
Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4663425
7 February 2012
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4222814
18 July 2011
Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4078972
7 July 2010
In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3634268
9 January 2010
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3662076
12 February 2009
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3415580
6 August 2008
Internal Structural Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3291175
27 February 2008
Periodic Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3150435
4 April 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2896053
4 December 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2834850
5 October 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2794417
16 June 2006
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2678974
8 March 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2589216
20 December 2005
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2554389
12 January 2005
COI Inspection · MTSA Verification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2272707
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957814
28 October 2003
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1933783
11 August 2003
Internal Structural Exam · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1869329
31 July 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1651007
6 August 2001
Deadweight Survey · COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1412333
11 September 2000
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 147704
8 August 2000
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1420381
10 November 1998
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 805918
24 September 1998
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 799465
14 August 1998
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1459445
9 September 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1262954
15 August 1996
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1357693
5 November 1994
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1181848
25 July 1994
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1177077
22 March 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2263
7 October 1993
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1136077
3 June 1993
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 11822
30 December 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 830233
5 November 1992
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 953523
9 April 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 949503
9 April 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1258487
6 January 1992
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 946857
17 December 1991
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 945309
6 August 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1253807
6 August 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1382468
7 November 1990
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1234633
24 November 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 916822
5 September 1989
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1199204
29 March 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 887132
22 December 1988
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1036177
13 December 1988
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 895965
30 January 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1001839
24 December 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1000996
14 October 1986
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1009620
13 August 1986
Permit to Proceed
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 988734
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2024
Resolved
Each panelboard must have: A circuit directory that has: The circuit designation of each circuit.
MI observed circuits labeled as "spare" in the on position. Address open circuits, or re-name directory.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 11 April 2024
Resolution: Recevied photographic evidence of correction
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2024
Resolved
No flexible cord may be used. MI observed non-permanent extension cord utilized in cargo pump room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 11 April 2024
Resolution: Recevied photographic evidence of correction
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2024
Resolved
Electrical installations on vessels must ensure protection of crew and the vessel from electrical hazards. MI observed a section of cable near stbd cargo pump bundled by cable ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 11 April 2024
Resolution: Recevied photographic evidence of correction
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 12 June 2023
No resolution recorded
Excessive wastage found in cargo tank bottom of #5 cargo tanks port and starboard. Cargo piping valve and spool piece for #5 tanks shall be removed and blanked. Piping shall be maintained in that condition until dry dock repairs of the cargo tank have been completed.
46 CFR 31.10-21(c)
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2023
No resolution recorded
If, during an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs.
Excessive wastage found in cargo tank bottom of #5 cargo tanks port and starboard. Areas to be cropped and renewed at next dry dock.
46 CFR 31.10-21 (c)
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2023
Resolved
If, during an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs.
Excessive wastage found in cargo tank bottom of #5 cargo tanks port and starboard. Wasted areas to be coated by 19MAY2023.
46 CFR 31.10-21(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 12 June 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 28 June 2022
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves located at the tank and must be arranged with a means of manual control locally at the valve and remotely from a readily accessible and safe location outside of the compartment in which the valves are located. 800 gallon diesel tank for generator does not have the required remote control located outside of the compartment.
Cite: 46 CFR 56.50-60(d)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 30 August 2022
Resolution: Verified installation of fuel oil shutoff for generator fuel tank
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 June 2022
Resolved
Every oil tanker of 150 gross tonnage and above shall be provided with an Oil Record Book Part II (Cargo/Ballast Operations). Vessel has not been maintaining an Oil Record Book Part II.
Cite: MARPOL 73/78 Annex I, Reg. 36.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 28 June 2022
Resolution: Going forward vessel o/o will fill out the ORB Part I and II for relevant entries.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 June 2022
Resolved
Every oil tanker of 150 gross tonnage and above shall be provided with an Oil Record Book Part I (Machinery Space Operations) and shall be completed on each occasion specified in Reg. 17.2. Vessel has not made entries in their Oil Record Book Part I since 24JAN2020.
Cite: MARPOL 73/73 Annex I, Reg. 17.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 June 2022
Resolution: o/o will fill out out the ORB Part I and II for relevant entries.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 28 June 2022
Resolved
For each ship subject to MARPOL Annex VI surveys and certification, details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of a bunker delivery note which shall contain at least the information specified in Appendix V of MARPOL Annex VI and must be retained for a period of three years after the fuel oil has been delivered on board. Vessel does not have the past three years of bunker delivery notes.
Cite: MARPOL 73/78 Annex VI, Reg. 18.5; Appendix V
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 30 August 2022
Resolution: Verified bunker delivery notes onboard
14 - Pollution Prevention › 146 - MARPOL Annex VI › Quality of fuel oil
Issued 28 June 2022
Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered. The sample is to be sealed and signed by the supplier's representative and the master of officer in charge of the bunker operation on completion of bunkering operations and retained under the ship's control until the fuel oil is substantially consumed, but in any case for a period not less than 12 months from the time of delivery. Vessel did not have the past 12 months of fuel oil samples.
Cite: MARPOL 73/78 Annex VI, Reg. 18.8.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 30 August 2022
Resolution: Verified bunker samples on board
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 March 2019
Resolved
CG001/46CFR31.10-17(a)/46CFR31.05-10(c)/701c - VESSEL MUST UNDERGO AN ANNUAL INSPECTION WITHIN 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. LATEST COI ISSUED ON 02JAN2018 WITH AN EXPIRATION DATE OF 03DEC2019, WHICH CORRESPONDS TO THE ANNIVERSARY DATE. LAST INSPECTION COMPLETED ON 02JAN2018, WITH FIRST ANNUAL INSPECTION DUE 3 MONTHS BEFORE OR AFTER 03DEC2018. VESSEL SURPASSED 3 MONTH PERIOD GRANTED BY REGULATION BEYOND ANNUAL INSPECTION DUE DATE, THEREBY INVALIDATING THE COI. IN ACCORDANCE WITH 46CFR31.05-10(c), THE VESSEL'S COI HAS BEEN REVOKED AND THE VESSEL MUST IMMEDIATELY GAS FREE ALL CARGO TANKS AND UNDERGO AN INSPECTION FOR CERTIFICATION PRIOR TO CARGO OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2019
Resolved 3 April 2019
Resolution: COI inspection complete this day.
Fire Fighting › Structural - A Class Divisions › Cargo Pump Rooms
Issued 6 April 2016
Resolved
Pump engine room forward door opens into the hazardous location indicated on the vessel's Hazardous Zone Plan. This arrangement requires that all electrical equipment within the pump engine room to be designed for hazardous locations. Either upgrade electrical equipment in this space or remove door. Ref. 46CFR111.105-31(m)
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 20 April 2016
Resolution: Door removed; steel insert welded in door location.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 March 2016
Resolved
Install guards to protect workers from exposed alternator, water pump and drive shaft pulleys on the generator prime mover to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 16 March 2016
Resolution: Protective guard was installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 March 2014
Resolved
JB01 - Remove soot filled lagging on port cargo pump exhaust. Inspect for and repair any exhaust leaks in exhaust prior to replacing lagging to the satisfaction of the attending marine inspector.
04/14/2014: Vessel representative [name withheld] requested an extension of 30 for the 835 due to service constraints.
Due 17 May 2014
Resolved 5 May 2014
Resolution: Sat Test of Repairs
Construction/Loadline › Hull › Double Hull
Issued 4 August 2006
Resolved
Gas free and make available for inspection number 2 stbd and number 2 double bottom voids.
Due 11 August 2006
Resolved 8 August 2006
Resolution: Completed inspection.
Deck/Cargo › Cargo Stowage
Issued 11 August 2003
Resolved
Conduct air testing of suspect areas (cargo residue) in way of inboard blkhds of #1 port/stbd cargo tanks in center passageway, in the presence of a CG marine inspector. Until test is conducted, no cargo shall be loaded into the #1 port/stbd tanks. LEGACY COMPONENT DESC: #1 port & stbd inboard bulkheads
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2003
Resolved 14 August 2003
Resolution: Witnessed satisfactory air testing of suspect areas, noting no leakage. Vsl will monitor the areas for the next two loading cycles and report all results of these inspections to the office.
Documentation › Certificates/Documents
Issued 31 July 2002
Resolved
Provide valid copy of the International Load Line Certificate LEGACY COMPONENT DESC: International Load Line Certificate
Condition: Unknown
Due 1 September 2002
Resolved 2 August 2002
Electrical
Issued 6 August 2001
Resolved
Properly fasten cables/wires leading to the main distribution panel using metal fasteners, IAW 46CFR111.60
Condition: Unknown
Due 24 October 2001
Resolved 24 October 2001
Electrical
Issued 6 August 2001
Resolved
Provide High Voltage warning sign on back of distribution panel IAW 46CFR111.01-1
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Deck/Cargo
Issued 6 August 2001
Resolved
Provide discharge removal equipment on board as requirede by 33CFR155.210
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Documentation
Issued 6 August 2001
Resolved
Provide a valid International Loadline Certificate per 46CFR31.25-1
Condition: Unknown
Due 24 October 2001
Resolved 24 October 2001
Electrical
Issued 6 August 2001
Resolved
Provide a machinery guard on the generator IAW 46CFR58.01-20
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Deck/Cargo
Issued 6 August 2001
Resolved
Provide a 30X30 mesh flame screen on the #4 Stbd P/V valve IAW 46CFR35.30- 10
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Deck/Cargo
Issued 6 August 2001
Resolved
Conspicously mark the location of the emergence cargo shut down located o the exterior aft deck house bulkhead IAW 46CFR32.50-35
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Documentation
Issued 14 August 1998
Resolved
SUBMIT STABILITY BOOK TO MSC FOR APPROVAL AND ISSUE OF REPLACEMENT STABILITY LETTER IAW 46 CFR 170.110.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Deck/Cargo
Issued 15 August 1996
Resolved
OPEN FOR INSPECTION EACH CARGO TANK PRESSURE/VACUUM (PV) VALVE PRIOR TO THECARRIAGE OF ANY OIL IN BULK AS CARGO OR CARGO RESIDUE AS REQUIRED BY 46 CFR38.25.10.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Documentation
Issued 15 August 1996
Resolved
PROVIDE A VESSEL RESPONSE PLAN TO THE U.S.C.G. FOR REVIEW AND APPROVAL PRIOR TO THE CARRIAGE OF ANY OIL IN BULK AS CARGO OR CARGO RESIDUE AS REQUIRED BY 33 CFR 155.1015.
Condition: Unknown
Due 15 August 1998
Resolved 9 September 1996
Documentation
Issued 15 August 1996
Resolved
PROVIDE SHIPBOARD OIL POLLUTION PREVENTION PLAN (SOPEP) APPROVAL LETTER FROM U.S. COAST GUARD AS REQUIRED BY MARPOL 73/78 ANNEX I REGULATION 26.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Deck/Cargo
Issued 15 August 1996
Resolved
PROVIDE DISCHARGE REMOVAL EQUIPMENT PRIOR TO THE CARRIAGE OF ANY OIL IN BULK AS CARGO OR CARGO RESIDUE AS REQUIRED BY 33 CFR 155.210.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Deck/Cargo
Issued 15 August 1996
Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR REVIEW AND APPROVAL TO THE U.S.C.G. PRIOR TO THE CARRIAGE OF ANY OIL IN BULK AS CARGO OR CARGO RESIDUE AS REQUIRED BY 33 CFR 155.720.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Deck/Cargo
Issued 15 August 1996
Resolved
HYDROSTATICALLY TEST ALL CARGO PIPING AND CARGO HOSE TO 1 1/2 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE (MAWP) PRIOR TO THE CARRIAGE OF ANY OIL IN BULK AS CARGO OR CARGO RESIDUE AS REQUIRED BY 33 CFR 156.170.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Deck/Cargo
Issued 5 November 1994
Resolved
PROVIDE EVIDENCE OF RECENT HYDRO TGESTING OF ALL CARGO PIPING PER 33CFR156.170
Condition: Unknown
Due 5 November 1994
Resolved 5 November 1994
Deck/Cargo
Issued 5 November 1994
Resolved
REPLACE FLAME SCREEN #4 PORT P/V VALVE.
Condition: Unknown
Due 5 November 1994
Resolved 5 November 1994
Deck/Cargo
Issued 5 November 1994
Resolved
PROVIDE EVIDENCE OF RECENT HYDRO TESTING OF ALL CARGO HOSES PER 33CFR156.170.
Condition: Unknown
Due 5 November 1994
Resolved 5 November 1994
Documentation
Issued 5 November 1994
Resolved
PROVIDE EVIDENCE OF PARTICIPATION IN BENZENE PROGRAM.
Condition: Unknown
Due 5 November 1994
Resolved 5 November 1994
Construction/Loadline
Issued 5 November 1994
Resolved
REPAIR ALL SIDE RAILS.
Condition: Unknown
Due 5 December 1994
Resolved 8 November 1994
Fire Fighting
Issued 5 November 1992
Resolved
PROVIDE PLACARDS FOR EACH HALON SYSTEM SHOWING INSTRUCTIONS FOR REMOTE AND LOCAL RELEASE OF SYSTEM.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Electrical
Issued 5 November 1992
Resolved
PROVIDE COVER FOR GENERATOR FAN.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Deck/Cargo
Issued 5 November 1992
Resolved
RETEST THE CARGO HOSES TO 1.5 MAWP AS REQUIRED IN 33 CFR. CARGO HOSES ARE NOT TO BE USED UNTIL RETESTED.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Electrical
Issued 5 November 1992
Resolved
PROVE REMOTE SHUTDOWNS FOR THE GENERATOR ARE FUNCTIONAL. GENERATOR NOT TO BE USED UNTIL SHUTDOWNS ARE OPERATIONAL
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Electrical
Issued 17 December 1991
Resolved
REPAIR BROKEN GENERATOR REMOTE SHUTDOWN SWITCH
Condition: Unknown
Due 10 January 1992
Resolved 6 January 1992
Deck/Cargo
Issued 7 November 1990
Resolved
HYDRO TEST CARGO PIPING AND HOSES AS OUTLINED IN 33CFR
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Electrical
Issued 7 November 1990
Resolved
PROVIDE GUARD FOR END OF GENERATOR SET.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Deck/Cargo
Issued 7 November 1990
Resolved
CALIBRATE CARGO PUMP GAUGES AND LOG
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Fire Fighting
Issued 7 November 1990
Resolved
SUBMIT FIRE EXTINGUISHER REPORT
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Construction/Loadline
Issued 13 December 1988
Resolved
MAKE WATERTIGHT - AS DESIGNED- MACHINERY SPACE ESCAPE SCUTTLE PRIOR TO 20DEC88 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Electrical
Issued 13 December 1988
Resolved
SHIELD MAIN ELECTRICAL SWITCH BOARD - MACHINERY SPACE - FROM LEAKAGE FROM ESCAPE SCUTTLE / HATCH PRIOR TO 27DEC88 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Deck/Cargo
Issued 13 December 1988
Resolved
TEST AND LOG CARGO PUMPS CORRECT RELIEF VALVE PRESSURE PRIOR TO CARGO TRANSFER OR 14 JAN89 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Deck/Cargo
Issued 24 December 1986
Resolved
3. PROPERLY TEST CARGO PUMPS TO MAX PRESSURE AT NEXT DISCHARGE OF CARGO TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 December 1986
Resolved 24 December 1986
Electrical
Issued 24 December 1986
Resolved
2. NEW GENERATOR IS NOT TO BE UTILIZED UNTIL DRAWINGS HAVE BEEN SUBMITTED TO [name withheld] AND APPROVED.
Condition: Unknown
Due 24 December 1986
Resolved 24 December 1986