Inspection history · 38
25 November 2025
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8273947
23 October 2025
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8244408
2 September 2025
Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8225278
7 December 2024
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8044555
7 December 2024
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8045201
18 September 2024
Annual Inspection · Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8005392
27 November 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7825970
3 July 2023
Deficiency Check · Damage Survey · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7730454
26 May 2023
Deficiency Check · Drydock Extension
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7696974
26 August 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7528012
26 July 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7516617
30 July 2021
In-Service Inspection · Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7272594
25 February 2021
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7146319
25 April 2020
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6943809
20 May 2019
Deficiency Check · Initial Certification · Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6712686
3 August 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6507163
19 July 2018
Industry Initiated Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6484663
17 May 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4862222
29 September 2013
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4725835
10 October 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4471164
28 February 2011
DAPI Audit · Industry Initiated Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3702010
28 January 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3934701
3 January 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3919534
4 October 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3866194
5 April 2009
Type not recorded
No type recorded · Station Curtis Bay · USCG East District (CGD-E) · Activity 3446701
4 March 2009
Industry Initiated Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3428297
7 November 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3359373
8 August 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 211031
8 August 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 757468
1 March 1999
Uninspected Towing Vessel
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800845
24 February 1999
Uninspected Towing Vessel
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797368
7 November 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 166984
4 November 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 723517
4 September 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 214811
12 September 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 142411
22 March 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2263
14 July 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 32279
23 January 1992
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 130041
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 23 October 2025
Resolved
Employers must maintain records of chemical tests and make available to the CG upon request. Provide updated list of crew that are in the drug testing program.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2025
Resolved 25 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 October 2025
Resolved
Each towing vessel must have visible and audible alarms for high bilge levels. Prove operation of high bilge alarm in lazarette.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2025
Resolved 25 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 October 2025
Resolved
There must be installed bilge pump/piping for dewatering. The mid-engine room bilge suction could not be tested due to oily water in the bilge. Test suction after oily water is removed.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2025
Resolved 25 November 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 October 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Repair the broken railing on the top deck, starboard side.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2025
Resolved 25 November 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 October 2025
Resolved
Ensure all hatches designed to be watertight or weather-tight function properly. The forepeak hatch cover could not be removed as designed.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2025
Resolved 25 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2025
Resolved
Stowage positions for lifejackets must be marked. Install markings or symbols for lifejacket storage.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 September 2025
Resolved
A vessel that is exposed to salt water more than 6 months in any 12 month period since the last examination
must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Vessel is overdue for it's drydock inspection. Drydock inspection was due no later than 31Aug2025. Conduct drydock inspection prior to commercial operations.
Action required: 705 - Other - as specified
Due 2 September 2025
Resolved 30 September 2025
Resolution: Completed credit DD/ISE
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 December 2024
Resolved
The managing owner or managing operator of a towing vessel, who has selected the Coast Guard inspection option, must make their vessel available for the Coast Guard to conduct the examinations required by this subpart in accordance with the intervals prescribed in § 137.300. Vessel has sustained fire damage to cabin area, vessel to be inspected for additional damage and all repairs to be completed and tested to the satisfaction of the Coast Guard prior to returning to service.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2025
Resolution: See Activity Number 8005392
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 September 2024
Resolved
After each modification, the lightweight characteristics must be recalculated. (b) When the aggregate weight change is more than 2 percent of the vessel's approved lightweight displacement, or the recalculated change in the vessel's lightweight LCG is more than 1 percent of the LBP, a deadweight survey must be performed to determine the vessel's current lightweight displacement and LCG. In accordance with stability letter issued by ABS;16JUNE2022, Any alteration resulting in a change of weight will invalidate the stability letter. Submit weight change calculations iaw MTN 04-95 to ABS iaw NVIC 3-97 Stability Related Review Performed by the American Bureau of Shipping for U.S. Flag Vessels. Have weight change evaluated and a stability review completed by ABS prior to commercial service.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2024
Resolved 13 June 2025
Resolution: See Activity Number 8005392
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 September 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Due to engine replacement, complete a sea trail at the completion of installation to the satisfaction of the Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2024
Resolved 13 June 2025
Resolution: See Activity Number 8005392
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 November 2023
Resolved
Essential systems or equipment must be regularly tested and examined. If a component is found unsatisfactory, it must be repaired or replaced. Three leaks were identified within the bilge piping system. Repair to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2023
Resolved 31 January 2024
Resolution: Conducted test of bilge piping using the fire pump. All leaks satisfactorily repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 November 2023
Resolved
Electrical conductors passing through watertight bulkheads must be installed so that the bulkhead remains watertight. Two penetrations on the aft fiddley bulkhead were not watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2023
Resolved 6 December 2023
Resolution: Penetrations closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2023
Resolved
Pressure vessels must be externally examined annually, relief valves tested, and must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. The port and stbd pressure vessel did not have a permanent stamp or nameplate attached indicating the MAWP and the temporary sticker was partially removed. In addition, several areas of deep pitting were identified on the tank surface of both the port and stbd tanks. Install new port and stbd pressure vessels meeting ABS Rules for Building and Classing vessel under 90 m in length or provide proof of existing tank design pressure and conduct a hydrostatic test under pressure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2023
Resolved 31 January 2024
Resolution: 02 new UPVs installed in ER.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 November 2023
Resolved
Each towing vessel must carry on board and maintain charts or maps that are currently corrected editions, if the vessel engages in towing seaward of navigable waters of the U.S. Provide a current paper chart of the area to be transited or provide an ENC that meets IEC 60945 or RTCM.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2023
Resolved 2 January 2024
Resolution: Charts are onboard
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 27 November 2023
Resolved
A towing vessel must be maintained and operated so the watertight integrity of the vessel are not compromised. A small pinhole was identified on the aft fiddley bulkhead IWO the watertight door. Repair to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2023
Resolved 6 December 2023
Resolution: Bulkhead repaired.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 September 2023
Resolved
Repair or replace the 01 deck control room watertight door, or place all electrical components in watertight enclosures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 16 October 2023
Resolution: See Activity Number 7730454.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 September 2023
Resolved
Replace missing stbd generator exhaust lagging.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 12 October 2023
Resolution: See Activity Number 7730454
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 12 September 2023
Resolved
De-scale the forward steering compartment bulkhead to allow for USCG Inspection prior to coating. This CG-835 is issued for 30 days and is not extendable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 11 October 2023
Resolution: See Activity Number 7730454
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 May 2023
Resolved
All hand-portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers onboard the vessel, must be inspected or tested at least once every 12 months. Semi-portable and portable fire extinguishers are overdue.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 26 May 2023
Resolved 30 May 2023
Resolution: All serviced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (5) High bilge levels. Laz bilge high level alarm is inoperable.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 26 May 2023
Resolved 30 May 2023
Resolution: Bilge float replaced. Alarm tested. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 June 2022
Resolved
All fire-detection systems must be inspected or tested at least once every 12 months. Provide servicing report.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 28 June 2022
Resolution: Received report. Uploaded to def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2022
Resolved
Verification of compliance with design standards, when required by §144.135, must be performed by an individual or entity who meets the requirements of §144.140. Provide evidence of plan approval for hull modifications.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 18 May 2022
Resolved 6 June 2022
Resolution: ABS review. See activity #7272594.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 May 2022
Resolved
The owner or managing operator of an existing vessel operating under a stability document must be
able to readily produce a copy of such document. Provide updated stability letter showing new lightship characteristics.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 18 May 2022
Resolved 17 June 2022
Resolution: New Stability LTR provided. Updated certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 January 2022
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel annual inspection is past due. Complete annual inspection prior to movement.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 28 January 2022
Resolved 13 June 2022
Resolution: Annual inspection conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2021
Resolved
Each towing vessel must comply with the requirements of part 4 of this chapter for reporting marine casualties. Vessel did not report marine casualty to the CG. Submit written report using CG-2692 to cognizant OCMI in which casualty occurred.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 30 July 2021
Resolved 5 August 2021
Resolution: Received CG-2692. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 July 2021
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel. Propulsion machinery, including main engines and reduction gears must: Be maintained to ensure proper operation. Port engine inoperable due to damage to transmission. Complete repairs and prove proper operation of propulsion system to satisfaction of attending Marine Inspector (MI).
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 July 2021
Resolved 13 June 2022
Resolution: Sea trials conducted. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 July 2021
Resolved
The cognizant OCMI may require review of a vessel's watertight and weathertight integrity. Complete repairs to main deck IWO P/S engine transmissions to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 July 2021
Resolved 9 March 2022
Resolution: Inserts installed/welded. NDT conducted using hose. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Pilot house - dead end wiring not in an enclosure, remove or place in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Pilot house - power panel missing breaker, install breaker or install blank.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Breakers installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Pilot house - junction box, splice made outside of enclosure, no wire stuffing tubes.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Box mounted and wires installed properly. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Pilot house – make cable penetrations weather tight.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Penetrations made weathertight. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Above Pilot house – Radar grounding cable not connected.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Cable connected. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Under Pilot house – Multiple dead end wires not in an enclosure, splices not in and enclosure, panels open not secured closed / missing knock outs not sealed, batteries wired using wing nuts, batteries not secure from shifting, all cable not properly supported, battery charger wiring not ran through stuffing tube, receptacle for battery chargers and other equipment not correct size for number of items plugged in.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: All issues under pilot house resolved. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Upper engine room, Stbd aft, old shoretie - exposed wires not in an enclosure. Remove or place in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Cables placed in enclosure. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Upper engine room - dead end wire forward of industrial engine. Remove or place in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Cables removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Upper engine room - Garmin Transducer junction box, no wire stuffing tubes, open.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Stuffing tube installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Upper engine room - power panel #4, forward bulkhead, missing breaker, install breaker or blank.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Breaker installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Upper engine room - wiring not supported properly. Properly secure wiring IAW CFR.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Wires supported. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Stbd Forward Engine room - dead end wire. Remove or place in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Stbd forward engine room - battery charger not permanently wired. Permanently wire battery charger.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Charger removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Stbd forward engine room - Light wiring spliced not in an enclosure, no wire stuffing tubes.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Placed in enclosure and properly wired. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Stbd forward engine room - Air compressor pressure switch missing electrical cover. Install electrical cover.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Cover installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port forward engine room - just aft of generator, multiple dead end wiring and splice not in an enclosure. Remove dead end wires or place in an enclosure. Place spliced wiring in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port forward engine room - Power panel #5 Dead end wires and splices not in an enclosure behind panel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Wires removed and splices in enclosures. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room - outboard of port main diesel engine, replace burnt/ damaged wire in overhead.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Replaced. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room - switchboard has opening in bottom, enclose opening.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 12 November 2020
Resolution: Opening enclosed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room - switch board, Generators are not capable or parallel operations, Install slide lock to ensure both generators cannot feed at the same time.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 12 November 2020
Resolution: Interlock installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room - #2 Air compressor junction box opening. Seal electrical junction box.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Sealed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room - both potable water pump Square D pressure switch boxes, wiring loose due to stuffing tubes not tight.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Stuffing tubes tight. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Aft deck below aft deck house - wiring not properly supported. Properly support wiring IAW CFR.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Wiring supported. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Aft deck below aft deck house - multiple dead end wires and splices not in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Dead end wires removed and splices placed in enclosures. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Aft deck, stbd side - damaged wire. Replaced damaged wire.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Replaced. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. General alarm, main deck, galley – Wiring loose not ran through proper stuffing tube connections.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Properly routed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Forward compartment, Dead end wire IWO entrance – Remove or place in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Forward compartment - Junction box knock out missing. Seal junction box.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Knock out installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Forward compartment - Port side light wiring - stuffing tube open.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Stuffing tube fixed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Forward compartment - Center light wiring missing stuffing tubes.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Stuffing tube installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Forward compartment - Center receptacle missing side and back knock outs, seal box.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Knock outs installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Forward compartment - Center receptacle, improper ground wire.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Receptacle properly wired. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Main deck port forward berthing area - rack light wired with extension cord not marine grade cable.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Proper wiring installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Main deck port forward berthing area - Remove receptacle or permanently wire.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Removed. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2020
Resolved
Firefighting outfits missing - provided two firefighter's outfits that meet NFPA 1971 and two self-contained apparatus approved by NIOSH under 42 CFR part 84. Prior to initial certification.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 November 2020
Resolution: Firefighting outfits provided. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2020
Resolved
Fire-detection system showing trouble alarm - clear alarm and show proper operation of system. Prior to initial certification.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Alarm cleared. Operational test conducted. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2020
Resolved
Stern light inoperable - repair/replace. Prove operation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Stern light operational. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2020
Resolved
Port MDE data link inactive and control of propulsion limited from operating station. Repair/replace and prove proper operation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Alarms cleared. Conducted U/W operational test of MDE. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2020
Resolved
STBD MDE overheating - prove proper operation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Found misaligned valves. Conducted U/W operational test. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 23 October 2020
Resolved
Vessel missing ILLC - provide ILLC. Prior to Initial Certification.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 21 December 2020
Resolution: Vessel issued COI. Vessel restricted to inside the boundary line. Will amend route upon receipt of ABS ILLC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 May 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
12NOV20: changed to Code 16. Vessel able to operate inside boundary line in Sector SENE AOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 21 December 2020
Resolution: COI Issued.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room – Electrical general – Ensure all dead end wiring, splices, etc. are in an enclosure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 3 November 2020
Resolution: Dead end wiring removed. All sat.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 May 2019
Resolved
No stability documentation onboard - provided stability documentation. Prior to Initial Certification.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 21 December 2020
Resolution: Vessel issued COI. COI Issued based on 10 years of operation with current arrangement. Restricted to inside boundary line until incline is conducted by ABS.