MAURY USCG vessel records
← All vessels

KAHOLO

Built
1983
Last inspected
20 March 2026
Controls
None recorded without a removal date
Also recorded as
JI 340-2 (2001), ALEUTIAN TRADER, JI 340-2, KAHOLO, MLC 340-2, UMTB (2006)

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 20 March 2026
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 39 calendar years (1985–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
5199 - Regulatory (Subpart C or D), Gross Ton 11059 - Convention (Subpart B), Gross Ton 5199 - Regulatory (Subpart C or D), Net Ton 6417 - Convention (Subpart B), Net Ton
Maury page id
psix-55312
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 86

20 March 2026 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8329452
21 March 2025 Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8097266
2 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8078226
3 May 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7908288
6 May 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7681413
11 February 2022 Examination of Repairs · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7393864
4 May 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7181686
22 August 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7040181
9 January 2020 Internal Structural Exam · Deficiency Check · Periodic Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6886593
11 April 2019 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6654436
21 August 2018 Examination of Repairs · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6519827
17 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6339193
14 December 2017 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6324730
14 February 2017 Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6088490
8 February 2017 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6087832
6 February 2017 Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6083406
18 November 2016 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6044156
18 February 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5814609
5 May 2015 Administrative Inspection · Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5118212
14 January 2015 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5049862
13 February 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4792165
9 January 2012 Hull Examination · COI Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4217599
19 January 2010 Examination of Repairs · Deficiency Check · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3665993
17 February 2009 Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3417630
10 February 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3415410
11 February 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3145905
12 March 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2886576
6 March 2007 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2883078
15 February 2007 Hull Examination · Initial Certification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2830885
9 August 2006 Construction Oversight · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2822100
2 August 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2735116
13 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2711524
8 March 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2305904
18 February 2005 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2320362
27 January 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2303161
15 December 2004 Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2248361
24 September 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2204079
2 June 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2086373
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979104
13 February 2003 Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1744465
3 July 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1640673
9 January 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1477245
10 December 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1645233
13 November 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1681140
7 October 2001 Deficiency Check · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1074322
28 September 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1379581
16 September 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382382
25 May 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1065475
9 April 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1397632
16 January 2001 Drydock Extension · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395635
13 June 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1365818
23 August 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 778706
10 August 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1466066
17 July 1998 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1398924
15 July 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1442599
2 September 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 652599
27 August 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1254387
25 July 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1089284
18 July 1996 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388071
26 June 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 193458
26 June 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 487870
30 April 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1083023
26 April 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383221
19 March 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359070
22 September 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 878015
15 August 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1405769
27 October 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 869143
13 September 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1180564
1 August 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1468761
18 August 1993 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1155807
2 July 1993 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1157294
28 May 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359567
15 January 1993 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1370546
8 January 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1443347
30 July 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 960593
19 May 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 947463
27 November 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1246372
15 May 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1216411
31 January 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1231326
11 January 1991 Deficiency Check · Permit to Proceed
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 920719
19 September 1990 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 928488
11 October 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1031238
30 September 1988 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1195169
29 December 1987 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1007757
17 March 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016974
19 December 1985 Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996055

Deficiency record · 44

Construction/Loadline › Hull › Longitudinal Frame
Issued 8 February 2017 Resolved
At dry dock, repair small fracture in flange of sideshell longitudinal frame in #1 STBD void. Frame is located in 3rd bay aft of the FWD bulkhead and is the 5th frame counting from the bottom up.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 14 December 2017
Resolution: Found frame properly repaired.
Construction/Loadline › Hull › Hull Plating
Issued 8 February 2017 Resolved
At dry dock remove rust scale from bottom plating, bottom logitudinal frames, welds, and the base of the centerline watertight bulkhead in the number 5 and number 4 voids.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 14 December 2017
Resolution: Found that area had been cleaned for inspection.
Stability › Watertight Integrity › General
Issued 8 February 2017 Resolved
At dry dock conduct necessary repairs to ensure all watertight hatches and doors are infact watertight. Conduct fire hose test on watertight hatches and conduct chalk test of the watertight door on the 2nd deck.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 14 December 2017
Resolution: All WTD were chalk tested, and all WTH were hose tested satisfactory.
Construction/Loadline › Hull › Bracket
Issued 8 February 2017 Resolved
At dry dock, repair tripped plate at center of K-brackets identified during 2017 ISE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 14 December 2017
Resolution: Found trip plate properly repaired.
Construction/Loadline › Hull › Hull Plating
Issued 18 November 2016 Resolved
Vessel experienced 6 inch high x 2 inch long breach in void #1 on starboard side. Vessel perfected an approved temporary repair in the form of a doubler. Vessel has 90 days to effect permanent repair to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 8 February 2017
Resolution: ABS witnessed/inspected fit up and permanent repairs. Accepted ABS report. All sat.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 January 2015 Resolved
See uploaded CG-835 dtd 14Jan2015
Action required: 705 - Other - as specified
Due 31 May 2015
Resolved 8 February 2017
Resolution: Spoke with vessel operator to inquire about if the items on the 835/email were addressed at dry dock in 2015. Operator indicated that our office had said we would accept the ABS survey as evidence to clear the 835. Verified with [name withheld] All sat.
Construction/Loadline › Hull › Bracket
Issued 20 January 2010 Resolved
In center fwd rake: crop and renew gussets at bottom longs L5-L8 port of centerline IWO aft bulkhead
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: Repair made accordingly with slightly large gusset.
Construction/Loadline › Hull › Stiffener
Issued 20 January 2010 Resolved
In center fwd rake: vee and reweld fracture at #8 bottom long stbd of centerline IWO transverse #1.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: Repair made accordingly.
Construction/Loadline › Hull › Bracket
Issued 20 January 2010 Resolved
In center fwd rake: crop and renew gusset at #5 bottom long stbd of centerline IWO of aft bulkhead.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: Renewed accordingly.
Construction/Loadline › Hull › Stiffener
Issued 20 January 2010 Resolved
In center fwd rake: vee and reweld fracture at #8 bottom long stbd of centerline IWO transverse frame #5.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: Corrected with renewal of gusset worklist item #11.
Construction/Loadline › Hull › Bottom Plating
Issued 19 January 2010 Resolved
In # 3 port void complete gauging on two softball size areas of bottom plate located at the # 1 bottom long, 24" forward of the aft bulkhead and # 2 bottom long 48" forward of the aft bulkhead.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: 10 shots provided 8 of 10 were at 4% wastage. Remaining two were at 25% and 24%; both isolated. Accepted repair proposal to clean and treat with epoxy based coating.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2010 Resolved
In port aft rake: Crop and renew tripped transverse frame IWO aft corner of port side rake and crop and renew inset in the side shell on the corner of port aft rake.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 27 February 2010
Resolution: Transverse frame renewed accordingly. Sideshell not renewed with concurrence from ABS surveyor; not within ABS Surveyor Notes criteria.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2010 Resolved
In #6 stbd, aft trim tank: provide repair proposal for fractured vertical frame #30 IWO 3rd side long from the main deck
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: Accepted proposal to Vee & weld same in concurrence with ABS surveyor. Witnessed same.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2010 Resolved
In stbd side fwd trim tank: Crop and renew vertical side frame btwn side longs 4&5 and reweld cracked weld at side long #6. Reweld SL #5 IWO of ladder. Reweld incomplete weld on the inboard vertical side frame IWO sidelong #5.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: Approved vee & reweld in concurrence with ABS surveyor. C&R not necessary IAW ABS survey notes. Noted sat welds applied to all.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2010 Resolved
In stbd fwd trim tank: vee and weld fracture on transverse frame at web to flange connection above bottom long #3.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: V&W completed to same.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2010 Resolved
In port fwd trim tank; Crop and renew web transverse frame from inboard upright vertical frame to btwn bottom longs 7&8.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 4 February 2010
Resolution: Frame repaired accordingly.
Construction/Loadline › Hull › Stiffener
Issued 19 January 2010 Resolved
In port fwd trim tank: vee and reweld bottom longs 1, 5, 6 & 7 IWO connection to transverse frame.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 4 February 2010
Resolution: Repair made accordingly.
Construction/Loadline › Hull › Stiffener
Issued 19 January 2010 Resolved
In port fwd trim tank: vee and reweld bottom long #4 IWO transverse frame
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 17 February 2010
Resolution: Repair made accordingly.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2010 Resolved
In port fwd rim tank: provide gauging to vertical side frame IWO connection to transverse frame flange (outboard side).
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: Six shots provided, all within ABS wastage allowance limits for internals. Wastage cleaned and treated with epoxy paint.
Construction/Loadline › Hull › Bracket
Issued 19 January 2010 Resolved
In port fwd trim tank: crop and renew gussets IWO bottom longs 2, 4 & 5 at connection with aft bulkhead.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 1 April 2010
Resolution: New gussets installed.
Construction/Loadline › Markings › Load Line Mark
Issued 17 February 2009 Resolved
Permantely affix deck line for load line.
Action required: 705 - Other - as specified
Due 19 March 2009
Resolved 11 March 2009
Construction/Loadline › Hull › Stiffener
Issued 17 February 2009 Resolved
Provide repair proposal for holed areas of frames 7 & 8 (from port side) in forward main deck void.
Action required: 705 - Other - as specified
Due 19 March 2009
Resolved 11 March 2009
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 17 February 2009 Resolved
Provide copy of annual review audit for SOPEP.
Action required: 705 - Other - as specified
Due 19 March 2009
Resolved 10 March 2009
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 17 February 2009 Resolved
Remove one portable containerized generator from barge.
Action required: 705 - Other - as specified
Due 19 March 2009
Resolved 10 March 2009
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 22 December 2008 Resolved
-The SOPEP must amend all references to Regulation 26 of Annex I, to reference Regulation 37 of Annex I of the International Convention for the Prevention of Pollution from Ships.
Due 22 January 2009
Resolved 14 May 2009
Resolution: Deficiency addressed and SOPEP amended accordingly. SOPEP approval expires 11/14/2011.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 18 February 2005 Resolved
Update all plans and vessel documents to reflect change in operator.
Due 2 March 2005
Resolved 23 March 2005
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 18 February 2005 Resolved
Provide copy of 340-2 Barge Loading Manual, bearing U.S.C.G. approval stamp dated 29 April 1992.
Due 2 March 2005
Resolved 23 March 2005
Construction/Loadline › Structures
Issued 13 February 2003 Resolved
Multiple cracks found in longitdinals in various locations on Barge. Vessel rep and ABS on scene. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 18 March 2003
Resolved 27 June 2003
Resolution: Received ABS survey report clearing oustanding def.
Construction/Loadline
Issued 28 September 2001 Resolved
After off load of cargo in Seattle, WA. crop out and renew with a new plateinsert on the barges STBD bow rake radius. All repairs must be to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Construction/Loadline
Issued 16 September 2001 Resolved
Barge is authorized to transit from Honolulu, HI to Coose Bay, OR with temprepairs (doubler plate) in place on side shell fracture of forward stbd rake (frame #2, 4ft below #2 side long). Upon arrival to Coose Bay, OR (prior to commercial operations) affect permanent repairs to damaged area.
Condition: Unknown
Due 16 September 2001
Resolved 16 September 2001
Deck/Cargo
Issued 18 July 1996 Resolved
MAKE TANK 2C AVAILABLE FOR INTERNAL INSPECTION BY 01 SEP 1996.
Condition: Unknown
Due 1 September 1996
Resolved 5 September 1996
Construction/Loadline
Issued 26 April 1996 Resolved
REPLACE MISSING STUDS FOR ALL MANHOLE COVERS ON OPEN DECK.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Construction/Loadline
Issued 26 April 1996 Resolved
IN VOID #3S REPAIR 5" FRACTURE AT JUNCTURE OF OUTBOARD VERTICAL FRAME #16 AND FLANGE OF SIDE LONGITUDINAL #4 FROM BOTTOM; ALSO REPAIR 1" FRACTURE IN FILLET WELD WHERE VERTICAL FRAME #16 JOINS TO HULL JUST ABOVE SIDE LONGITUDINAL #4.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Construction/Loadline
Issued 19 March 1996 Resolved
DURING ISE OF STB VOID, TWO 6 INCH FRACTURES OF THE WELDS WERE NOTED AT THEWELD JUNCTIONS LOCATED AT TRANSVERSE FRAME 10 AT SIDE LONGS 4 AND 5 FROM THE BOTTOM. V AND REWELD.
Condition: Unknown
Due 19 March 1996
Resolved 19 March 1996
Construction/Loadline
Issued 19 March 1996 Resolved
DURING ISE OF NR 6 PORT VOID, IT WAS NOTED THAT AT FRAMES 3 AND 4 AFT OF THE FWD BULKHEAD IN THE AREA OF SIDE LONG 5 FROM THE BOTTOM THAT FRAME STRENGTH MEMBER WAS TRIPPED. CROP AND RENEW.
Condition: Unknown
Due 19 March 1996
Resolved 19 March 1996
Construction/Loadline
Issued 19 March 1996 Resolved
DURING ISE OF VOID 5 STB, A FRACTURE OF THE WELD AT FRAME 22 IN UNDERDECK DEEP KNEE OF TRANSVERSE FRAME WAS NOTED. V AND REWELD.
Condition: Unknown
Due 19 March 1996
Resolved 19 March 1996
Lifesaving
Issued 19 March 1996 Resolved
DURING INSPECTION BY MARINE CHEMIST OF NR 4 STB VOID TANK A LIQUID WAS NOTED. CHEMICAL ANALYSIS SHOWED THE LIQUID TO HAVE A PH OF 12. VSL REP STATED A TANKERMAN HAD EMPTIED 2 SEPERATE CARGO HOSES OF CAUSTIC SODA INTO 4 STB VOID AND 6 PORT. SOLUTION TO BE DISCHARGED TO A COA FACILITY.
Condition: Unknown
Due 19 March 1996
Resolved 19 March 1996
Electrical
Issued 15 August 1995 Resolved
CONTAINERIZED GENERATOR SET TO BE APPRANGED IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 15 August 1995 Resolved
REPAIR 5 INCH FRACTURE IN WELD AT 2ND STIFFENER AFT OF FRAME NO. 1 IN WAY OF STB SIDE SHELL APPROX 5 FT. BELOW MAIN DECK.
Condition: Unknown
Due 24 August 1995
Resolved 21 August 1995
Electrical
Issued 15 August 1995 Resolved
PROVIDE PLANS FOR ARRANGEMENT OF CONTAINERIZED GENERATOR SET. TO INCLUDE FUEL TANK, FIRE FIGHTING, VENTING, EMERGENCY ENGINE SHUT DOWN, GENERATOR & PRIME MOVER PARTICULARS, ARRANGEMENT TO BE IN COMPLIANCE WITH 46 CFR SUBPART I, O, J & F. CONDITIONS OF OPERATION.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 13 September 1994 Resolved
INSTALL INSERT ON 2ND TRANSVERSE FRAME AFT IN #3 CENTER CARGO TANK IN WAY OF CRACK AT BASE OF DIAGONAL SUPPORT BEAM ON PORT-MOST SIDE (18" X 18"). COMPLETE REPAIRS NLT 14NOV94 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Deck/Cargo
Issued 28 May 1993 Resolved
COMPLETE PERMANENT PIPING SYSTEM FOR TANK 6C IN ACCORDANCE WITH APPROVED PLANS DATED 7 MAY 93. UNTIL COMPLETED CARRIAGE OF CAUSTIC SODA IS LIMITED TO TANKS 4C AND 5C._x001C_ _x001C_
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Deck/Cargo
Issued 8 January 1993 Resolved
INSTALL A PERMANENT PUMPING AND PIPING SYSTEM IN ACCORDANCE WITH APPROVED PLANS, UNTIL INSTALLED, THE CARRIAGE OF CAUSTIC SODA IS LIMITED TO CENTER TANKS 4 & 5._x001C_ _x001C_
Condition: Unknown
Due 8 January 1993
Resolved 8 January 1993
Construction/Loadline
Issued 19 September 1990 Resolved
MAKE REPAIRS IN THE STARBOARD FORWARD RAKE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.