MAURY USCG vessel records
← All vessels

FMT 3110

Built
2002
Last inspected
27 February 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 27 February 2025
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 16 calendar years (2002–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

597954
Flag
UNITED STATES
Maury page id
psix-597954

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 36 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 11 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 36

27 February 2025 Periodic Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8085883
20 October 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7811734
6 April 2023 Internal Structural Exam · Cargo Tank Internal · Drydock Exam · MTSA Verification · COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7664201
12 August 2019 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6781460
8 December 2017 Examination of Repairs · MTSA Verification · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6321103
5 January 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6065595
12 February 2016 Periodic Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5812980
24 February 2015 MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5073978
19 February 2014 Annual Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4801987
3 December 2012 COI Inspection · Drydock Exam · MTSA Verification · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4476626
24 September 2012 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4450596
23 September 2012 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4455934
31 January 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4235406
26 September 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3857305
6 September 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3843507
9 February 2010 Examination of Repairs · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3677456
2 February 2010 MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3674337
14 January 2009 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3392656
14 January 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3394583
8 November 2007 Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3094083
28 December 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2847216
5 October 2006 Annual Inspection · Deficiency Check · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2792674
29 September 2006 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2789973
29 September 2006 Permit to Proceed
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2792714
26 September 2006 Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2787829
26 September 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2846428
6 February 2006 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2580268
3 October 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2507009
27 January 2005 MTSA Verification · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2281593
13 March 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2038433
12 March 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2038419
4 February 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2000649
30 January 2004 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1997863
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979085
2 September 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1906319
8 November 2002 Internal Structural Exam · Cargo Tank Internal · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1698823

Deficiency record · 21

Engineering › Diesel Engine (auxiliary) › Block
Issued 14 December 2017 Resolved
Install machinery guard on exposed belt on cargo pump prime mover.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 31 May 2018
Resolution: Replaced entire prime mover package.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 14 December 2017 Resolved
Start cargo pump prime mover and ensure operation of the emergency shutdown.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 31 May 2018
Resolution: Entire prime mover was replaced, shutdown was tested, All Sat.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 December 2017 Resolved
Empty and properly dispose of oil in the discharge containment at the port and starboard collections.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 7 May 2018
Resolution: Verified containment had been emptied and cleaned.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 14 December 2017 Resolved
Lower mast riser for inspection of the flame screen. Unable to inspect.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 31 May 2018
Resolution: Inspected satisfactory
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 14 December 2017 Resolved
Ensure cargo pump relief valve tested and P/V valves free for operation, if safe to do so. Unable to verify due to cargo vapors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 31 May 2018
Resolution: Tested 5/28/2018
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 14 December 2017 Resolved
High level and overfill alarms unable to be tested. Ensure proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 31 May 2018
Resolution: Tested all Sat.
Engineering › Fuel Oil Service System › Hose
Issued 14 December 2017 Resolved
Replace or renew chaffed and cracked fuel lines with SAEJ1942 hose and fittings, or equivalent, where indicated by inspector on cargo pump prime mover.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 31 May 2018
Resolution: All hoses were replaced when new prime mover was installed.
Construction/Loadline › Structures › Superstructure
Issued 14 December 2017 Resolved
Provide UT report for pitting on the cargo tank tops as indicated by marine inspector. Random pits gauged are greater than 25% of the 3/8" plate. Numerous pits found scattered over the cargo tank tops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 25 May 2018
Resolution: Gauging report provided and reviewed satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 14 December 2017 Resolved
Clean, rework, and replace rising meter sticks as indicated by marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 31 May 2018
Resolution: All meter sticks were inspected on this date.
Construction/Loadline › Structures › Manhole
Issued 14 December 2017 Resolved
Grind and reweld ladder attachments in #4 and #5 starboard voids.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2018
Resolved 11 May 2018
Resolution: All repairs carried out as outlined and verified during ISE.
Construction/Loadline › Penetrations › Gasket
Issued 12 February 2016 Resolved
Two deck hatch gaskets for accessing sideshell voids required renewal to meet weather tightness requirmenents (ABS Steel Vessel Rules; Hull Construction and Equipment).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 22 February 2016
Resolution: New gaskets properly installed in each hatch cover.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 21 February 2014 Resolved
Replace inoperable cargo pump diesel engine RPM guage.
Action required: 705 - Other - as specified
Due 21 March 2014
Resolved 25 February 2014
Resolution: Replaced guage
Deck/Cargo › Holds/Tanks › Hatch
Issued 21 February 2014 Resolved
Install hatch gasket on the #5 port wing void.
Action required: 705 - Other - as specified
Due 21 March 2014
Resolved 25 February 2014
Resolution: Put new gasket in hatch cover.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 21 February 2014 Resolved
Repair or replace slop oil tank rising stick guage.
Action required: 705 - Other - as specified
Due 21 March 2014
Resolved 25 February 2014
Resolution: Replaced with new rising stick.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 21 February 2014 Resolved
Repair or replace the rising stick guage on the #2 port cargo tank.
Action required: 705 - Other - as specified
Due 21 March 2014
Resolved 25 February 2014
Resolution: Replaced with new rising stick.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 21 February 2014 Resolved
Replace closed guage sight glass on the #1 starboard cargo tank.
Action required: 705 - Other - as specified
Due 21 March 2014
Resolved 13 March 2014
Resolution: Replaced glass
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 2 February 2010 Resolved
#1 P/S cargo tank hermetic seal sample/guage points are heavily wasted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 February 2010
Resolved 9 February 2010
Resolution: Witnessed proper repair.
Construction/Loadline › Structures › Deck Plating
Issued 2 February 2010 Resolved
Stern walking deck is heavily wasted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 February 2010
Resolved 9 February 2010
Resolution: Vessel rep produced NDT of walking deck proving scantling above minimum allowable thickness
Construction/Loadline › Hull › Collision Chock
Issued 29 September 2006 Resolved
Vessel has a 5" inset, 2 feet long, six feet from the centerline, located in the port head log area. Issued PTP.
Condition: Unknown
Due 29 September 2006
Resolved 6 October 2006
Resolution: 6'' X 3'' insert on starboard side bow rake approx 3 ft from centerline, just below head log. Approx 4'' of head log cropped and replaced. Witnessed air test, all Sat.
Construction/Loadline › Hull › Double Hull
Issued 26 September 2006 Resolved
Vessel is to be presented in a gas free and safe for workers condition for further inspection of observed damage and surrounding areas.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2006
Resolution: 6'' X 3'' insert on starboard side bow rake approx 3 ft from centerline, just below head log. Approx 4'' of head log cropped and replaced. Witnessed air test, all Sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 30 January 2004 Resolved
Prove proper operation and emergency shutdown of cargo transfer pump prior to discharge of cargo. LEGACY COMPONENT DESC: Cargo Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 4 February 2004
Resolution: Witnessed satisfactory operation and emergency shutdown of cargo transfer pump.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.