ODYSEA is a 2000 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2000, most recently in February 2026, along with 50 deficiencies, 2 operational controls and 2 casualty investigations between 2012 and 2017.

Records from 2000 to 2026. Most recent: inspection, 17 February 2026.

Built
2000
Last inspected
17 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3673
Flag
UNITED STATES
367117220
Maury page id
psix-6343

Inspections, by type

…with no type recorded3
Years with a record 18 calendar years (2000–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 8.5 ft × 7.0 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS · LAKE HAVASU CITY, AZ, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSIESTA KEY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton
12 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3673MMSI 367117220 · active · compulsorily equipped · granted 26 January 2017, expires 26 January 2027
WDD2585MMSI 367117220 · expired · compulsorily equipped · granted 26 May 2006, cancelled 30 July 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HIGH FLYER ONE Passenger (Inspected) · MISLE 801741 · 23 December 2017 · activity 6329134GUST O Passenger (Inspected) · MISLE 935167 · 23 December 2017 · activity 6329134BOSS Passenger (Inspected) · MISLE 5899 · 11 August 2017 · activity 6241830HIGH FLYER ONE Passenger (Inspected) · MISLE 801741 · 11 August 2017 · activity 6241830GUST O Passenger (Inspected) · MISLE 935167 · 11 August 2017 · activity 6241830

Inspection history · 34

17 February 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8285796
2 February 2026 Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8286891
27 February 2025 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8062818
5 December 2023 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7816615
28 April 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7616495
5 December 2022 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7601422
4 March 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7404920
3 December 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7353529
15 January 2021 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7125116
16 December 2019 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6852179
25 January 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6614940
4 December 2018 Examination of Repairs · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6584436
23 December 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6329134
27 November 2017 COI Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6313425
11 August 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6241369
11 August 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6241830
9 February 2017 Administrative Inspection · Annual Inspection · Hull Examination · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076365
9 February 2016 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5808755
26 October 2015 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5751218
19 May 2014 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4866137
4 March 2014 Simplified Stability Test · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4811191
26 July 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4391392
26 July 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4392300
5 June 2012 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4334386
1 February 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4235803
9 May 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3202447
15 June 2007 Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2962332
15 May 2006 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2640538
19 May 2005 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2342205
24 July 2001 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1451741
31 January 2001 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1057602
21 September 2000 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 822005
5 May 2000 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1429381
5 May 2000 Hull Examination · Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1455861

Deficiency record · 50

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2026 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for drydock examination on 31DEC2025 and has yet to receive a drydock exam. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2026
Resolved 3 February 2026
Resolution: Granted drydock credit
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The fuel fill pipe is missing the conductor to bond the metal in between the flexible rubber fill piping. 46 CFR 182.445(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2022
Resolved 10 January 2023
Resolution: The operator installed a 8 AWG conductor to bond the metal fuel fill pipe to the metal tank over the flexible fuel fill piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Blade fuses were found installed as primary overcurrent protection for conductors in the DC electrical system. 46 CFR 183.380(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2022
Resolved 10 January 2023
Resolution: The operator replaced all fuses with UL listed cartridge type fuses of the same amperage rating.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2022 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The operator was unable to complete the sponson pressure tests as per the local [name withheld] work instruction and additional Coast Guard policy due to a missing pressure gauge. 46 CFR 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 9 March 2023
Resolution: Conducted PSI test of newly installed sponson including individual chamber tests checking interior baffles. Used manufacture instructions provided by Inflatable Marlin Services. Tests sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 December 2022 Resolved
Piping used in a vital system must be composed of ferrous materials. The sea water cooling piping located in the engine room and used to cool the lower main engine propulsion unit through the transom is flexible plastic piping. The system is deemed to be piping for a vital system and shall be constructed of ferrous material. The current plastic piping poses a down flooding risk in the engine room if it fails. 46 CFR 182.710(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2022
Resolved 10 January 2023
Resolution: The operator removed the plastic piping in the engine room used to cool the main engine and capped the metal through hull valve at the hull plate.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 December 2018 Resolved
A pre-engineered fixed gas fire extinguishing system must autmatically shut down engine. System does automatically shut down, however, may restart after attempt to restart prior to engaging over ride switch. Service system and prove satisfactory operation of shut down/override system. 46 CFR 181.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2018
Resolved 13 December 2018
Resolution: Technician serviced system to work in tandem with current installed engine.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 February 2017 Resolved
Install fixed fire extinguishing system for engine room meeting requirements of 46 CFR 181.420. Manual actuation from outside the space does not meet approved design requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2017
Resolution: Operator installed a new 325 cubic foot capacity Fireboy with new manual pull cable.
Stability › Intact Righting Energy › General
Issued 9 February 2017 Resolved
Two leaks were found in port side sponson during pressure test possibly affecting overal stability of vessel. 46CFR178
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2017
Resolution: Leaks were patched and pressure tested SAT.
Construction/Loadline › Hull › Side Shell
Issued 9 February 2016 Resolved
Properly Repair leak on RHI, located portside/2nd Chamber.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2016
Resolved 16 February 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 February 2016 Resolved
Show proof of service for the B-1, located at the control console.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2016
Resolved 16 February 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 February 2016 Resolved
Show proof of proper operation of the emergency engine shutdown/override.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2016
Resolved 16 February 2016
Engineering › Bilge Water Management System › Valve
Issued 9 February 2016 Resolved
Properly install a positive shut-off valve, on all bilge pump discharges at the hull penetration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Communications › Radio Communications › EPIRB
Issued 9 February 2016 Resolved
Properly mount EPIRB, so that it is float free.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 February 2016 Resolved
Conduct satisfactory man-overboard drill in the presence of CG marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2016
Resolved 16 February 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 May 2014 Resolved
Replace expired battery for ring life buoy IAW 46CFR180.70(d)(2)
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 29 May 2014
Resolution: Operator replaced for ring life bouy.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 4 March 2014 Resolved
Engine controls are not functioning properly, resulting in loss of propulsion control. Repair IAW 184.620.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2014
Resolved 5 March 2014
Resolution: O/O discovered a solenoid in the transmission/engine control system was wired backwards, preventing the clutch from engaging in either forward or reverse. Solenoid was rewired properly and engine/trans is fully functional, as verified by sea trials.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 26 July 2012 Resolved
Make repairs to the vessel. Demonstrate proper operation of the propulsion system to the satisfaction of the attending Marine Inspector. 46 CFR 176.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2012
Resolved 7 August 2012
Resolution: Witnessed proper operation of the propulsion system.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 June 2008 Resolved
Must install deck rails that meet minimum height requirement for excursion trips as required by 46 CFR 177.900 (39.5 inches with 4 inch courses). Must submit plans for approval prior to making rail modifications. Vessel will be allowed to continue operations for the next 30 days, if not corrected by then will reassess with CID.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 8 June 2009
Resolution: See Special Notes: Current rail set up is accepted by local OCMI.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 June 2008 Resolved
Vessel must label bow area fwd of fixed seating indicating no PAX allowed.
Action required: 705 - Other - as specified
Due 27 June 2009
Resolved 15 June 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 9 May 2008 Resolved
Renew/ replace engine room pre-engineered fire extinguishing system (fire boy) prior to carrying PAX.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 3 June 2008
Resolution: Fire boy bottle was replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 May 2008 Resolved
Conduct operational test of pre-engineered fire extinguishing system (fire boy) engine operation/ shutdowns prior to carrying PAX once renewed/ replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 3 June 2008
Resolution: Test was SAT.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2008 Resolved
Provide lock washers or lock nuts on all four battery connections.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 3 June 2008
Resolution: Lock washers were installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2008 Resolved
Provide aspirin and eye wash for first aid kit.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 3 June 2008
Resolution: Aspirin and eye wash were purchased.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 May 2008 Resolved
Provide copies of Coast Pilot, tides and current tables.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 3 June 2008
Resolution: Coast Pilot, tides and current tables were purchased.
Electrical › Electric Supply System (service) › Cable
Issued 9 May 2008 Resolved
Repair/ remove disconnected wires and dead end wires in the engine room.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 3 June 2008
Resolution: Wires and dead end wires were removed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 June 2007 Resolved
Properly mark the vessel with the name on the port and stbd bow.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 15 June 2007 Resolved
Provide proof of an FCC Operator Permit for the Master.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 June 2007 Resolved
Service all fire extinguishers.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 18 June 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 June 2007 Resolved
Provide proof of contract with a consortium.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 15 June 2007 Resolved
Provide list of employee's covered in program.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 15 June 2007 Resolved
Provide proof of MIS report submission.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 June 2007 Resolved
Provide an alcohol test kit for use within two hours of a SMI.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Engineering › Fuel Oil Service System › Hose
Issued 15 June 2007 Resolved
Replace fuel hoses with approved type.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 June 2007 Resolved
Install lock washers or lock nuts on the battery connections.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 15 June 2007 Resolved
Provide a handle for the manual activation of the fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 30 July 2007
Communications › Radio Communications › EPIRB
Issued 15 June 2007 Resolved
Install a new hydrostatic release for the EBIRB, the vessel is restricted from carrying passengers until the new release is installed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2007
Resolved 18 June 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 June 2007 Resolved
Vessel was not made available for the hull exam in accordance with the Certificate of Inspection.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 15 June 2007
Resolution: Conducted the hull exam while in attendance for the annual inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 April 2005 Resolved
Provide an audible alarm for the fixed fire fighting extinguishing control head. New system was installed and works properly, but no audible alarm sounds.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 3 June 2005
Lifesaving › Lifebuoys › Approval
Issued 26 April 2005 Resolved
Provide a 24" ring life buoy that is orange in color IAW 46CFR180.70(b)(5). POC bought a white ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 3 June 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 26 April 2005 Resolved
Label vent covers and fix securing snaps around vents. Missing snaps around the vents, so the covers have no means of securing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 3 June 2005
Lifesaving
Issued 24 July 2001 Resolved
Prove proper operation of running lts, compass lt & ring buoy lt.
Condition: Unknown
Due 31 July 2001
Resolved 17 August 2001
Documentation
Issued 24 July 2001 Resolved
Provide on board vsl the following documents: FCC License, Certificate of Documentation & Stability ltr.
Condition: Unknown
Due 24 August 2001
Resolved 17 August 2001
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2001 Resolved
Provide proof of company enrollment in a drug testing consortium.
Condition: Unknown
Due 24 August 2001
Resolved 26 April 2005
Electrical
Issued 24 July 2001 Resolved
Prove proper operation of VHF-FM radio.
Condition: Unknown
Due 31 July 2001
Resolved 9 August 2001
Lifesaving
Issued 24 July 2001 Resolved
Provide on board 01, adult PFD.
Condition: Unknown
Due 31 July 2001
Resolved 9 August 2001
Construction/Loadline
Issued 24 July 2001 Resolved
Provide on board, 01, portable bilge hand pump w/sufficient hose to discharge over the side of the vsl.
Condition: Unknown
Due 31 July 2001
Resolved 9 August 2001
Engineering
Issued 5 May 2000 Resolved
INSTALL A VENTILATION/IGNITION INTER-LOCK IN ACCORDANCE WITH 46 CFR_x001C_ 182.460 (e). UNTIL INTER-LOCK IS INSTALLED ENSURE THE ENGINEROOM HATCHES ARE OPENED AND EXHAUST VENTS ARE RUNNING FOR A MINIMUM OF 5 MINUTES PRIOR TO STARTING THE ENGINE.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Lifesaving
Issued 5 May 2000 Resolved
Conduct a stability test. _x001C_
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Documentation
Issued 5 May 2000 Resolved
Provide a licensed operater that is enrolled in a approved drug testing program._x001C_
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Lifesaving
Issued 5 May 2000 Resolved
Coduct a set of emergency drills._x001C_
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000

Casualty record · 2

26 July 2012Routine · role: Involved in a Marine Casualty · activity 4392300
23 December 2017Routine · role: Transiting Vicinity of Primary Subject · activity 6329134
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.