Records from 2011 to 2026. Most recent: inspection, 17 February 2026.
Inspection history · 21
17 February 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8285798
23 December 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8286892
13 January 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8062848
10 January 2024
Deficiency Check · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7818069
28 February 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7616488
28 February 2023
COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7631296
8 February 2022
Internal Structural Exam · Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7379992
17 May 2021
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7196527
25 February 2020
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6896919
6 February 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6611595
16 February 2018
DAPI Audit · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6356429
23 December 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6329134
23 December 2017
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6333086
7 November 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6302374
10 October 2017
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6285836
11 August 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6241830
10 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6137159
9 February 2017
Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076361
15 August 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5987205
14 June 2016
Type not recorded
No type recorded · Station Cortez · USCG Southeast District (CGD-SE) · Activity 5914146
16 February 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5815496
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2025
Resolved
Shut off valves at the tank must be operable from outside the compartment.
The shut off valves pull straight when full opened. The valves and pull cable shall be adjusted for more consistant closing operation. This shall be completed within 1 week.
46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2025
Resolved 1 April 2025
Resolution: Verified the fuel valve was repositioned so the shut off would work properly. SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2024
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter.
The grab line on the ring life buoy was frayed and the retro-reflective material was peeling.
46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 22 January 2024
Resolution: Retro and lines were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 10 January 2024
Resolved
Rails must be installed near the periphery of all decks accessible to passengers or crew and be capable of withstanding a 200 lbs. force.
The Stbd bow railing was loose at its mounting base. This should be properly fastened.
46 CFR 177.900
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 22 January 2024
Resolution: Rail mounting hardware was tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 January 2024
Resolved
An exposed hazard,such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
The vessel did not have a guard installed for belt in engine room compartment.
46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 23 January 2024
Resolution: Belt guard was installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 February 2023
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. A pre-engineered fixed gas fire extinguishing system must: be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector as per 46 CFR 181.420.
The FireBoy preventer pin was found installed in the way of the manual remote activation pull cable. The crew immediately remedied the deficiency and the system is ready for immediate use.
46 CFR 185.100
Action required: 10 - Deficiency Rectified
Due 28 February 2023
Resolved 28 February 2023
Resolution: The crew immediately remedied the deficiency by removing the pin and the system is now ready for immediate use.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 February 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve.
The remote shutoff valves were found frozen open when tested by the crew. The crew serviced the valves and remedied the deficiency.
46 CFR 182.455
Action required: 10 - Deficiency Rectified
Due 28 February 2023
Resolved 28 February 2023
Resolution: The crew applied grease to each fuel shutoff valve and completed a remote test of each valve.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 February 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
The engine compartment forward bulkhead was found with three 2" diameter holes in it which permits the fixed gas extinguishing system agent to escape the engine compartment.
46 CFR 182.465(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 9 March 2023
Resolution: The operator sealed the forward engine room bulkhead using 3M fire block.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant.
The operator installed blade type fuses in the DC electrical system.
46 CFR 183.380(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 9 March 2023
Resolution: The operator installed UL listed cartridge fuses in place of the blade fuses.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
The FCC station license certificate was found expired.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2023
Resolved 9 March 2023
Resolution: A FCC technician attended the vessel and issued a new FCC station license certificate.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 February 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
The operator installed trim tabs on the transom using a standard wood screw to attach the trim tab under the waterline. The wood screw was found penetrating the transom in the engine room and presents a hull penetration hazard if it backs out of the transom FRP.
46 CFR 177.100
Action required: 705 - Other - as specified
Due 7 March 2023
Resolved 9 March 2023
Resolution: The operator removed the wood screw and secured the trim tabs using a hex lag screw with nuts to retain in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2022
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
The lanyard connecting the water light was approximately 18 inches, and was not attached around the body of the life ring buoy.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 28 February 2022
Resolution: Vessel sent in pictures of a 5ft line attached to the ring buoy from the floating waterlight.
Engineering › Thrusters › Motor
Issued 10 October 2017
Resolved
Remove bow thruster motor from service and disconnect from power source due to fire. 46 CFR 183.320
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2017
Resolved 6 November 2017
Resolution: Tested new thruster system, all sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 October 2017
Resolved
Prove operation of fuel shut-off valve. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Tested fuel shutoff valve, all sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 10 October 2017
Resolved
Replace expended B-1 portable fire extinguisher. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Replaced with new B-I extinguisher.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 10 October 2017
Resolved
Provide onboard one B-11 portable fire extinguisher. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Provided an approved B-II extinguisher.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 October 2017
Resolved
Label adult life jacket stowage location with 18 required lifejackets. 46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Labeled all lifejacket stowage locations.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 October 2017
Resolved
Provide ten serviceable lifejackets onboard vessel. 46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Replaced all affected lifejackets.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2017
Resolved
Must renew FCC Radio Safety Certificate. Vessel is restricted to 1000 ft from shore until certificate is renewed. 47 CFR 80
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 12 May 2017
Resolution: Deficiency corrected, Certificate provided to the Marine Inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 February 2017
Resolved
Install stuffing tube for electrical penetration, starboard side forward engine room bulkhead. 46 CFR 179.320(e)
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Operator installed stuffing tube for electrical run.