MAURY USCG vessel records
← All vessels

HIGH FLYER ONE

HIGH FLYER ONE is a 2005 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in February 2026, along with 19 deficiencies and 6 casualty investigations between 2011 and 2017.

Records from 2011 to 2026. Most recent: inspection, 17 February 2026.

Built
2005
Last inspected
17 February 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG7115
801741
Flag
UNITED STATES
Maury page id
psix-801741

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSIESTA KEY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 5 January 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ODYSEA Passenger (Inspected) · MISLE 6343 · 23 December 2017 · activity 6329134GUST O Passenger (Inspected) · MISLE 935167 · 23 December 2017 · activity 6329134BOSS Passenger (Inspected) · MISLE 5899 · 11 August 2017 · activity 6241830ODYSEA Passenger (Inspected) · MISLE 6343 · 11 August 2017 · activity 6241830GUST O Passenger (Inspected) · MISLE 935167 · 11 August 2017 · activity 6241830

Inspection history · 21

17 February 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8285798
23 December 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8286892
13 January 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8062848
10 January 2024 Deficiency Check · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7818069
28 February 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7616488
28 February 2023 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7631296
8 February 2022 Internal Structural Exam · Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7379992
17 May 2021 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7196527
25 February 2020 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6896919
6 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6611595
16 February 2018 DAPI Audit · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6356429
23 December 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6329134
23 December 2017 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6333086
7 November 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6302374
10 October 2017 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6285836
11 August 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6241830
10 May 2017 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6137159
9 February 2017 Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076361
15 August 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5987205
14 June 2016 Type not recorded
No type recorded · Station Cortez · USCG Southeast District (CGD-SE) · Activity 5914146
16 February 2016 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5815496

Deficiency record · 19

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2025 Resolved
Shut off valves at the tank must be operable from outside the compartment. The shut off valves pull straight when full opened. The valves and pull cable shall be adjusted for more consistant closing operation. This shall be completed within 1 week. 46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2025
Resolved 1 April 2025
Resolution: Verified the fuel valve was repositioned so the shut off would work properly. SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2024 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. The grab line on the ring life buoy was frayed and the retro-reflective material was peeling. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 22 January 2024
Resolution: Retro and lines were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 10 January 2024 Resolved
Rails must be installed near the periphery of all decks accessible to passengers or crew and be capable of withstanding a 200 lbs. force. The Stbd bow railing was loose at its mounting base. This should be properly fastened. 46 CFR 177.900
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 22 January 2024
Resolution: Rail mounting hardware was tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 January 2024 Resolved
An exposed hazard,such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The vessel did not have a guard installed for belt in engine room compartment. 46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 23 January 2024
Resolution: Belt guard was installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 February 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. A pre-engineered fixed gas fire extinguishing system must: be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector as per 46 CFR 181.420. The FireBoy preventer pin was found installed in the way of the manual remote activation pull cable. The crew immediately remedied the deficiency and the system is ready for immediate use. 46 CFR 185.100
Action required: 10 - Deficiency Rectified
Due 28 February 2023
Resolved 28 February 2023
Resolution: The crew immediately remedied the deficiency by removing the pin and the system is now ready for immediate use.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 February 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. The remote shutoff valves were found frozen open when tested by the crew. The crew serviced the valves and remedied the deficiency. 46 CFR 182.455
Action required: 10 - Deficiency Rectified
Due 28 February 2023
Resolved 28 February 2023
Resolution: The crew applied grease to each fuel shutoff valve and completed a remote test of each valve.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 February 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The engine compartment forward bulkhead was found with three 2" diameter holes in it which permits the fixed gas extinguishing system agent to escape the engine compartment. 46 CFR 182.465(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 9 March 2023
Resolution: The operator sealed the forward engine room bulkhead using 3M fire block.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2023 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The operator installed blade type fuses in the DC electrical system. 46 CFR 183.380(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 9 March 2023
Resolution: The operator installed UL listed cartridge fuses in place of the blade fuses.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC station license certificate was found expired. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2023
Resolved 9 March 2023
Resolution: A FCC technician attended the vessel and issued a new FCC station license certificate.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 February 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. The operator installed trim tabs on the transom using a standard wood screw to attach the trim tab under the waterline. The wood screw was found penetrating the transom in the engine room and presents a hull penetration hazard if it backs out of the transom FRP. 46 CFR 177.100
Action required: 705 - Other - as specified
Due 7 March 2023
Resolved 9 March 2023
Resolution: The operator removed the wood screw and secured the trim tabs using a hex lag screw with nuts to retain in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2022 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The lanyard connecting the water light was approximately 18 inches, and was not attached around the body of the life ring buoy. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 28 February 2022
Resolution: Vessel sent in pictures of a 5ft line attached to the ring buoy from the floating waterlight.
Engineering › Thrusters › Motor
Issued 10 October 2017 Resolved
Remove bow thruster motor from service and disconnect from power source due to fire. 46 CFR 183.320
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2017
Resolved 6 November 2017
Resolution: Tested new thruster system, all sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 October 2017 Resolved
Prove operation of fuel shut-off valve. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Tested fuel shutoff valve, all sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 10 October 2017 Resolved
Replace expended B-1 portable fire extinguisher. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Replaced with new B-I extinguisher.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 10 October 2017 Resolved
Provide onboard one B-11 portable fire extinguisher. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Provided an approved B-II extinguisher.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 October 2017 Resolved
Label adult life jacket stowage location with 18 required lifejackets. 46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Labeled all lifejacket stowage locations.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 October 2017 Resolved
Provide ten serviceable lifejackets onboard vessel. 46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Replaced all affected lifejackets.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2017 Resolved
Must renew FCC Radio Safety Certificate. Vessel is restricted to 1000 ft from shore until certificate is renewed. 47 CFR 80
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 12 May 2017
Resolution: Deficiency corrected, Certificate provided to the Marine Inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 February 2017 Resolved
Install stuffing tube for electrical penetration, starboard side forward engine room bulkhead. 46 CFR 179.320(e)
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Operator installed stuffing tube for electrical run.

Casualty record · 6

13 September 2011Routine · role: Involved in a Marine Casualty · activity 4144836
25 June 2013Routine · role: Involved in a Marine Casualty · activity 4632271
24 March 2015Routine · role: Involved in a Marine Casualty · activity 5090209
7 May 2015Routine · role: Involved in a Marine Casualty · activity 5119983
10 July 2015Routine · role: Involved in a Marine Casualty · activity 5182909
23 December 2017Routine · role: Involved in a Marine Casualty · activity 6329134
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.