Records from 2016 to 2026. Most recent: inspection, 10 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 18
10 February 2026
COI Inspection · Drydock Exam · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8305246
27 February 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8062843
17 May 2023
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7677366
28 February 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7631266
8 February 2022
Internal Structural Exam · Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7379996
20 July 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7263045
23 February 2021
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7144932
27 February 2020
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6896947
7 February 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6611594
2 May 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6405628
27 February 2018
Internal Structural Exam · DAPI Audit · Drydock Exam · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6362316
23 December 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6329134
8 November 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6303574
28 August 2017
Simplified Stability Test · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6251312
11 August 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6241830
24 February 2017
Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6106560
24 January 2017
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076401
9 February 2016
DAPI Audit · Internal Structural Exam · Simplified Stability Test · COI Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5811874
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 February 2026
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, and(2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
MI discovered operator was missing flares.Vessel operator was missing 03 distress flares.
46 CFR 180.68 (a) (1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2026
Resolved 10 February 2026
Resolution: Operator provided proof that they had supplied the required distress flares for the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2026
Resolved
Shutoff valves, installed so as to close against the fuel flow must be fitted in the fuel supply lines. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
MI discovered handle for starboard side fuel shut off had been broken.
46 CFR 182.455
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2026
Resolved 10 February 2026
Resolution: Vessel operator provided proof that the shut off valve had been repaired and was functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2023
Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
When activating the fuel shut off from the operating station is did not close fully on port or starboard. Vessel adjusted the cable and was able to achieve full close.
46 CFR 182.455(4)
Action required: 10 - Deficiency Rectified
Due 28 February 2023
Resolved 28 February 2023
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 February 2023
Resolved
Each life line on a ring life buoy must be of at least 60 feet in length.
Vessel only had 50 feet of line.
46 CFR 180.70(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 2 March 2023
Resolution: Vessel supplied pictures with new 70' of line.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 February 2023
Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed the emergency instruction placard should contain at least the application portions of the emergency instructions listen in 185.512.
The vessels emergency instructions include shutting ventilation to the engine room vents in case of fireboy activation, the forward centerline on the bulkhead has open access that cannot be secured.
46 CFR 185.510(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2023
Resolved 13 March 2023
Resolution: POC sent picture showing area being sealed off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 February 2023
Resolved
Vessel must be provided with bilge pumps in accordance with table 182.520(a). Vessel did not have a portable hand pump.
46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 2 March 2023
Resolution: Vessel supplied picture with new hand pump purchased and placed onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2022
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
The lanyard connecting the water light was approximately 18 inches, and was not attached around the body of the life ring buoy.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 28 February 2022
Resolution: Vessel sent in pictures of a 5ft line attached to the ring buoy from the floating waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 February 2022
Resolved
Each vessel certificated to operate on a limited coastwise route within three miles of land in warm water must either...have on board a FCC Type Accepted Category 1 406 MHz EPIRB, installed to automatically float free and activate.
The Hydrostatic release for the EPIRB is expired.
46 CFR 180.205(e)(3)
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Vessel replaced the hydrostatic release with a new one.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 March 2021
Resolved
Each hydrostatic release unit, other disposable unit, must be serviced: within 12 months of its manufacture and within 12 months of each subsequent servicing. Hydrostatic release discovered expired. O/O replaced with valid hydrostatic release.
46CFR185.740
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O rectified the discrepancy on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2021
Resolved
All fuel tanks must be electrically bonded to a common ground. Both fuel tank grounding cables lead directly to adjacent fuel tank.
46CFR182.440
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 17 March 2021
Resolution: Vessel representative [name withheld], provided photographs via e-mail displaying each fuel tank with a bond to a common ground. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2021
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point and any direction. Port side #1 stanchion base found with loose hardware which enabled movement when force was applied to the port side deck rail.
46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: O/O tightened down hardware to stantion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Both adult and child life jackets found stowed in the same location.
46CFR180.78
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 18 March 2021
Resolution: Vessel representative provided photograph via e-mail of the storage of child/adult lifejackets properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2021
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point and any direction. Discovered fractured welds in the bases of the starboard side stanchions #4 and #5 and port side stanchion #1.
46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 25 March 2021
Resolution: Vessel representative provided photographs of new welds in the bases of the starboard side stanchions #4 and #5 and port side stanchion #1.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2021
Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Common grounding plate found not installed to vessel's hull.
46CFR183.372
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 17 March 2021
Resolution: Vessel representative [name withheld], provided photographs via e-mail displaying the common ground plate properly installed on the vessel's hull. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Port side emergency fuel shutoff not marked.
46CFR185.608
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 18 March 2021
Resolution: Vessel representative provided photograph via e-mail of the port emergency fuel shutoff properly labeled.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 February 2017
Resolved
Provide Safety Radiotelephony Certificate onboard. 47 CFR 80.13
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 17 February 2017
Resolution: Operator placed valid Safety Radio Certificate onboard vessel.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 February 2017
Resolved
Provide proof that employees have signed company drug testing policy. 46 CFR 16.401(a)
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 17 February 2017
Resolution: Verified employees have signed company drug testing policy.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 February 2017
Resolved
Provide proof of employee EAP training. 46 CFR 16.401(b)
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 17 February 2017
Resolution: Verified employee EAP training.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 February 2017
Resolved
Provide B-II portable extinguisher for outside machinery space. 46 CFR 181.500
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 17 February 2017
Resolution: Operator provided B-II extinguisher.