Documentation record
Registered dimensions (L × B × D)47.2 ft × 14.0 ft × 6.3 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPETERSON BUILDERS INC · STURGEON BAY WI · built 1955
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portESCANABA, MI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 13 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 13
23 October 2025
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8267042
15 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8234820
20 December 2024
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8051337
3 November 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7819989
29 June 2022
COI Inspection · Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7528828
13 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7430499
13 April 2022
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7486030
21 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6957467
18 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6534452
10 September 2013
Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4711750
5 September 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4437575
9 July 2012
Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4373091
6 August 1994
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 493510
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 December 2024
Resolved
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Lifebuoys must be at least 610 millimeters (24 inches) in diameter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2024
Resolution: Ring buoy renewed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 December 2024
Resolved
Each U.S. flag vessel subject to this subpart must have an inspection of the required radiotelephone installation at least once every 48 months. Required certificates required by the FCC are expire. Renew.
47 CFR 80.953(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 January 2025
Resolution: FCC certs renewed.
05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 20 December 2024
Resolved
The operational status of pilothouse instrumentation including deviation errors of the compass. Deviation of the compass has never been assessed. Provide deviation table for compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 January 2025
Resolution: Deviation table provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 December 2024
Resolved
Machinery systems must be maintained to provide for safe operation of the towing vessel. Steering gear is missing securing devices. Conduct necessary repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2024
Resolution: Steering gear has been properly secured.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 December 2024
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Non-intergal keel coolers are actively leaking. Conduct necessary repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2024
Resolution: Keel cooler has been tighten and leak secured.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 December 2024
No resolution recorded
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Abandoned pipes in the fwd ER need to be properly covered or removed at next drydock.
30DEC2024: Pipes were covered and will be removed at the next drydock. Action code updated to 705.
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 December 2024
Resolved
Each remote valve control must be marked in clearly legible letters, at least 1 inch high, indicating the purpose of the valve and the way to operate it.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2024
Resolution: Valves properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 20 December 2024
Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion Suits are not marked properly. Remark suits.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2024
Resolution: Suits properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 December 2024
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370. Vessel is missing 2 flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2024
Resolution: The proper number of flares purchased and placed in adequate storage container.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 20 December 2024
Resolved
Fire detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Smoke detector battery in wheel house was removed to avoid nuisance alarm, detector broken upon battery replacement. Renew smoke detector in Wheelhouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2024
Resolution: Smoke detector renewed and installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 December 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists such as the high water level alarm. Alarm is inoperable. Conduct necessary repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2024
Resolution: High water bilge alarm was repaired and is operable.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 November 2023
Resolved
Fire detection panel was inoperable due to the batteries being disconnected. Once the batteries were connected and the system had time to recharge, the system operated properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2023
Resolved 3 November 2023
Resolution: Video documentation showing proper operation of the fire detection panel was sent by [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2023
Resolved
The fuel shut off lables were worn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2023
Resolved 3 November 2023
Resolution: Labels were renewed
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 November 2023
Resolved
Hydrostatic release on the inflatable liferaft was not marked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2023
Resolved 3 November 2023
Resolution: Hydrostatic release expiration date was properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 11 October 2022
Resolved
Radar (12 Volt, Furuno GaAs FET Front End 8-Tone Daylight Display) not compliant with RTCM 95 Standards. When vessel operating beyond 3 miles from shore, an approved Radar is required as required by 33 CFR 164.72. Remove and replace with an approved Radar.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 December 2022
Resolved 13 October 2022
Resolution: O/O stated vessel would typically operate within 3 miles from shore. Requirement cleared. Special noted added for CG MI to review logbook history during annual exams.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 October 2022
Resolved
Vessel not fitted with a Life raft. O/O required to fit the vessel an inflatable B Pack Life raft as required 46 CFR Table 141.305
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 20 October 2022
Resolution: O/O stated a life raft would be installed onboard when vessel operating. Company rep stated he would submit a request letter to the OCMI asking not to fit the vessel with a life raft when operating in a limited area.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 April 2022
Resolved
CG records (MISLE & copy of vessels COD) reflects vessel is out of service. MISLE inspection note additionally reflect vessel must comply with 46 CFR subchapter M regulations. Vessel does not have a valid Certificate of Inspection (COI). With vessel operating in commercial towing service, managing owner/operator has four Subchapter M towing vessels operating in commercial towing service. Deficiency issued in accordance with 46 CFR 136.202(a)(3), requiring the vessel not to be used in or for commercial towing services as owner/operator must have valid COI’s on 75% of their towing vessels.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 13 May 2022
Resolved 11 October 2022
Resolution: Observed valid COD with Registry & Coastwise endorsements.