Records from 1993 to 2026. Most recent: inspection, 11 June 2026.
Inspection history · 26
11 June 2026
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8406268
21 November 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8270859
30 August 2024
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7992541
29 August 2024
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7979334
15 September 2023
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7782311
22 June 2023
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7720843
18 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7533901
2 November 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7343792
29 July 2021
Initial Certification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7257031
25 May 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7206793
10 April 2021
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7188912
23 July 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6488464
24 February 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6361971
26 January 2017
Industry Initiated Exam · Administration · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6081421
6 November 2013
Deficiency Check · Industry Initiated Exam · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4747590
13 August 2010
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3747123
12 February 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2005561
15 February 2002
Uninspected Towing Vessel
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1486820
12 February 2002
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1601681
9 September 1996
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 752837
7 September 1996
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 176458
7 September 1996
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 203128
22 November 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 4959
1 September 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 659045
30 August 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 360612
29 August 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 185757
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 November 2025
Resolved
The system is installed, tested, and maintained in accordance with the manufacturer's design. Zone not reading.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 November 2025
Resolution: The system has been tested, and in accordance with the manufacturer's design. Zone is in compliance.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 August 2022
Resolved
Found starboard Main rudder ram making hard contact with rudder stop in a way that it was making the deck flex. Adjust rudder or adjust stop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2022
Resolved 23 September 2022
Resolution: Installed a rudder stop to adjust the way that it was making the deck flex, no longer hits the rudder stop
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 August 2022
Resolved
Port search light was not working. They need a searchlight, directable from the vessel's main steering station and capable of illuminating objects at a distance of at least two times the length of the tow.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2022
Resolved 23 September 2022
Resolution: search light bulb was replaced, is now operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 July 2021
Resolved
An auxiliary generator engine must be equipped with an RPM gauge. The gauge on the starboard generator was not functioning.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2021
Resolved 29 July 2021
Resolution: Fixed loose connection. Repaired on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 July 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours. The battery operated emergency light in the engine room was not operable. Repair or replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2021
Resolved 4 August 2021
Resolution: Installed new batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2021
Resolved
Nonconductive mats or grating must be provided on the deck in front of each switchboard and, if it is accessible from the rear, on the deck behind the switchboard. No mat was placed in front of the fuse panel on the upper cat walk in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2021
Resolved 29 July 2021
Resolution: Placed mat on deck. corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 July 2021
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover.
(c) The valve must be installed in the fuel piping directly outside of the fuel oil supply tank.
The fuel shutoff valves are installed inside the fuel tanks.
Relocate fuel shutoff valves to outside the fuel tank as close as practicable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2026
Resolved 11 August 2026
Resolution: Observed operation of newly installed fuel shutoff valves. Operation test sat.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 29 July 2021
Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers.
Emergency duties list was not posted in pilot house.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2021
Resolved 29 July 2021
Resolution: sign posted in pilot house. Corrected on the spot
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 July 2021
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe.
A pin on the steering rudder gear had a crack in it.
Repair as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2021
Resolved 4 August 2021
Resolution: welded crack
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 July 2021
Resolved
Each towing vessel must have either self-priming, power driven, fixed fire pump, a fire main.
The pump on the fire main was leaking water.
Repair to minimize the leaking water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2021
Resolved 29 July 2021
Resolution: tightened packing. Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 May 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2021
Resolved 2 November 2021
Resolution: Vessel was issued a COI on 29JUL2021
Documentation › Logs/Records
Issued 15 February 2002
Resolved
Coast Guard Local Notice to Mariners
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Operations/Management › Cargo Transfer/Lightering
Issued 15 February 2002
Resolved
OIL TRANSFER PROCEDURES NOT UP TO DATE AND OR ADEQUATE LEGACY COMPONENT DESC: Facility Operations Manual on Hand
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Communications › Radio Communications
Issued 15 February 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Operations/Management
Issued 15 February 2002
Resolved
VESSEL WITH SQUARE BOW THE NAME AND HAILING PORT DISPLAYED LEGACY COMPONENT DESC: Navigation Underway, General
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Documentation › Logs/Records
Issued 15 February 2002
Resolved
VSL LOG OF REQUIRED TEST AND INSPECTIONS LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Navigation
Issued 15 February 2002
Resolved
RIVER CHARTS LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Navigation
Issued 15 February 2002
Resolved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Documentation › Manuals/Policy Documentation
Issued 15 February 2002
Resolved
PIC CARRED A LETTER OF INSTRUCTION LEGACY COMPONENT DESC: Company Action Plan (SIP)
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Construction/Loadline
Issued 15 February 2002
Resolved
DECK STANCHIONS (AFT)
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Fire Fighting › Miscellaneous Items
Issued 15 February 2002
Resolved
FUEL TANK VENTS FLAME SCREENS
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 15 February 2002
Resolved
Unknown Component - Missing (46CFR28.215)
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Navigation
Issued 15 February 2002
Resolved
STEERING SYSTMES: GRADING AND CATCHMENT
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Electrical › Lighting (service)
Issued 15 February 2002
Resolved
GLOBES AND LIGHT SOCKET OVER PORT SHAFT LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Documentation › Markings/Placards
Issued 12 February 2002
Resolved
MAR POL PLACARDS LEGACY COMPONENT DESC: Oil Discharge Placard
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 12 February 2002
Resolved
MSD PLACARD W/ OPERATION INSTRUCTIONS LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 27 March 2002
Lifesaving
Issued 30 August 1993
Resolved
M/V THOMAS C.L. NUGENT HAD 06 P.O.B. AND ONLY 04 LIFEVESTS. THEY ARE REQUIRED TO HAVE ONE LIFEVEST FOR EACH P.O.B.
Condition: Unknown
Due 30 September 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past