Records from 2005 to 2026. Most recent: inspection, 13 January 2026.
Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2005
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 25 September 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
13 January 2026
Bulk Liquid Transfer Monitor
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8295919
23 October 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8257692
10 March 2025
Drydock Exam · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8091436
23 June 2023
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7721634
11 June 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7712144
22 June 2021
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7232938
14 February 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6909225
5 September 2018
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6533361
24 May 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6534435
13 July 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6207473
27 April 2017
Periodic Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6133631
12 January 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6070028
27 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5862303
5 October 2015
Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5736617
17 April 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5107650
6 March 2015
Administrative Inspection · MTSA Verification · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5079531
10 March 2014
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4813578
12 January 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4223593
3 January 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4235473
28 December 2011
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4215148
19 January 2010
COI Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3665883
16 June 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3506748
5 May 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3467779
21 January 2009
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3397834
11 April 2008
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3178977
15 March 2007
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2882993
12 June 2006
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2677557
30 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2665102
2 March 2005
MTSA Verification · Cargo Tank Internal · Hull Examination · Initial Certification · Internal Structural Exam
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2301897
9 February 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2289442
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 13 July 2017
Resolved
Received notification that approx 1/2" of product was discovered at the bottom of the #2 void. Vsl is authorized a one time discharge of product at ITC Deer Park. Once cargo ops have been completed, the vessel is authorized to proceed to a shipyard within the SEC HOU-GAL AOR to make permanent repairs. Make vsl available for inspection by a CG Marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 July 2017
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 May 2006
Resolved
Conduct a vapor tightness test of the vapor control system IAW 33 CFR 156.170)g), after unloading and..
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2006
Resolved 13 June 2006
Resolution: Test conducted
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 30 May 2006
Resolved
Conduct a test of the transfer piping system IAW 33 CFR 156.170(c)(4), after unloading and...
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2006
Resolution: Test conducted successfully.
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 30 May 2006
Resolved
Conduct a test of the high level and overfill alarms IAW 33 CFR 156.170(c)(ii)(5) and (f)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2006
Resolution: Test conducted successfully.