MAURY USCG vessel records
← All vessels

CBC 396

CBC 396 is a 2014 tank barge. The Coast Guard has recorded 18 inspections since 2014, most recently in May 2026, along with 2 deficiencies and 3 casualty investigations between 2020 and 2026.

Records from 2014 to 2026. Most recent: inspection, 20 May 2026.

Built
2014
Last inspected
20 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1311081
Flag
UNITED STATES
Maury page id
psix-1311081

Inspections, by type

…with no type recorded4
Years with a record 8 calendar years (2014–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD Shipyard LLC · AMELIA, LA, UNITED STATES · built 2014
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 16 September 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 12

Inspection history · 18

20 May 2026 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8372275
13 April 2026 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8349527
12 February 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8309881
10 February 2026 Examination of Repairs · Vessel Attendance
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8311550
1 January 2026 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8290757
5 February 2025 Administrative Inspection · Internal Structural Exam · COI Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8075105
1 December 2023 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7861084
12 March 2020 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6925285
15 February 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6917619
28 January 2020 Examination of Repairs · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6893229
27 August 2018 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6519679
17 August 2018 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6515338
17 August 2018 Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6519680
28 March 2018 Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6381109
16 December 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6057363
4 January 2016 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5788309
17 April 2015 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5107650
1 December 2014 Construction Oversight · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5039570

Deficiency record · 2

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 April 2026 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Vessel was involved in an allsion causing damage to port quarter and several stbd voids. Satisfactory temp repairs have been made. Vessel is authorized to make a one way transit to Jefferson, Beaumont, TX in accordance with their submitted and approved transit plan. Upon completion of discharge, proceed to repair facility to effect permanent repairs. Ensure concurrent clearance is sought with COTP zones you will be transiting. Once permanent repairs completed, this 835 may then be cleared by cognizant OCMI where repairs are made.
Action required: 705 - Other - as specified
Resolved 20 May 2026
Resolution: Repairs made to stern, STBD wing void #1, and STBD wing void #2. Witnessed satisfactory air test of all repairs. All sat
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 17 August 2018 Resolved
Found major inset damage to exterior of cargo tank top on port side of vessel. Directed representative to conduct repairs to satisfaction of [name withheld] discharge of cargo then to proceed immediately to Tubal Cain shipyard for repairs.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 31 August 2018
Resolved 27 August 2018

Casualty record · 3

15 February 2020Routine · role: Involved in a Marine Casualty · activity 6917619
1 December 2023Routine · role: Involved in a Marine Casualty · activity 7861084
1 January 2026Routine · role: Involved in a Marine Casualty · activity 8290757
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record