Inspection record

Last inspected 15 May 2026
…with no type recorded32
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI7701
Flag
UNITED STATES
Maury page id
psix-74750

Documentation record

Registered dimensions (L × B × D)70.0 ft × 24.0 ft × 7.2 ft
Registered tonnagegross 134 / net 91
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENVILLE BARGE CONSTRUC · GREENVILLE, MS, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBELLE CHASSE, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 30 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it134 - Regulatory (Subpart C or D), Gross Ton
91 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 46 inspections, each with its date, unit and type; 42 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 20 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 20

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUSAN CROSBY Industrial Vessel · MISLE 434559 · 22 August 2022 · activity 7571568MEM 5004 Freight Barge · MISLE 461671 · 22 August 2022 · activity 7571568MEM 480 Freight Barge · MISLE 465810 · 22 August 2022 · activity 7571568MEM 483 Freight Barge · MISLE 465813 · 22 August 2022 · activity 7571568MEM 5070 Freight Barge · MISLE 472292 · 22 August 2022 · activity 7571568MEM 5142 Freight Barge · MISLE 475945 · 22 August 2022 · activity 7571568ACL 06622 Freight Barge · MISLE 807225 · 22 August 2022 · activity 7571568SD 15 Tank Barge · MISLE 45726 · 30 May 2022 · activity 7469938BOBBY JONES Towing Vessel · MISLE 88945 · 30 May 2022 · activity 7469938MEM 233 Freight Barge · MISLE 398958 · 30 May 2022 · activity 7469938W H 1705 Freight Barge · MISLE 256203 · 26 March 1996 · activity 45631BEYEL 001 Freight Barge · MISLE 442112 · 26 March 1996 · activity 45631BEYEL 002 Freight Barge · MISLE 442115 · 26 March 1996 · activity 45631POSEIDON Tank Barge · MISLE 47744 · 18 July 1995 · activity 154879SALVATION ROSE Towing Vessel · MISLE 108217 · 18 July 1995 · activity 154879DELTA-9 Tank Barge · MISLE 396723 · 30 January 1994 · activity 12811DELTA 11 Tank Barge · MISLE 401113 · 30 January 1994 · activity 12811DELTA-9 Tank Barge · MISLE 396723 · 24 January 1994 · activity 32DELTA 11 Tank Barge · MISLE 401113 · 24 January 1994 · activity 32DELTA 10 Tank Barge · MISLE 43065 · 16 January 1994 · activity 70300ASA 5 Tank Barge · MISLE 44859 · 16 January 1994 · activity 70300L & A MARINE CRANE BARGE # 1 Industrial Vessel · MISLE 374629 · 18 September 1992 · activity 187111

Inspection history · 46

15 May 2026 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8375550
8 May 2026 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8383650
5 March 2026 Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8323238
3 November 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8262426
4 September 2025 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8227051
17 September 2024 COI Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7980913
6 October 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7804494
19 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7610778
19 December 2022 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7622233
22 September 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7553696
22 August 2022 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7571568
30 May 2022 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7469938
19 November 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7317380
5 February 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7136000
23 January 2020 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6897671
6 January 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6883356
26 June 2019 Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6718095
29 January 2019 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6628954
15 August 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6251205
1 July 2016 MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5922243
12 December 2013 Administration
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 4768048
25 March 1999 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511052
13 March 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 82463
4 March 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 170773
9 July 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 77234
15 November 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 65630
11 July 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 172171
10 May 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 717529
1 April 1996 Uninspected Towing Vessel · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1078371
26 March 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 45631
7 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 148989
28 February 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 87187
28 February 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 127518
28 February 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 159616
6 February 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 90057
14 January 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 164338
6 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 143269
24 August 1995 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 753366
18 July 1995 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 154879
18 July 1995 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 204520
18 April 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 692080
16 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 108570
30 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 12811
24 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 32
16 January 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 70300
18 September 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 187111

Deficiency record · 42

14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 3 December 2024 Resolved
Each towing vessel must be operated in compliance with Parts 151, 155, and 156, of 33 CFR, as applicable. No person may operate a non-oceangoing ship of 100 gross tons and above that is fitted with main or auxiliary machinery spaces in the navigable waters of the United States unless: The ship has a stop valve for each outlet required by this section. MI discovered that the overboard discharge valve for the bilge system was inoperable and was rattling loose. Make repairs to the satisfaction of the attending MI. 46 CFR 140.655 705C
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 13 May 2025
Resolution: received video evidence
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 December 2024 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. MI found that the ER panel was not properly labeled. Make repairs to the satisfaction of the attending MI. 46 CFR 143.400
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 12 May 2025
Resolution: Recived photo evidance from [name withheld]
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 3 December 2024 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. MI found that E light was not working. Make repairs to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 12 May 2025
Resolution: Recived photo evidance from [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2024 Resolved
Towing vessels more than 65 feet in length must use navigation lights that meet UL 1104 (incorporated by reference, see § 136.112 of this subchapter) or other standards accepted by the Coast Guard. MI discovered that the Navigational lights were not operating properly. Make repairs to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 12 May 2025
Resolution: Recived photo evidance from [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 December 2024 Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move. MI found that the oil tank to be loose and not secured to the vessel in anyway. Make repairs to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 13 May 2025
Resolution: received pictures
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2024 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. MI discovered that there was no protective grating over the steering gear. Make repairs to the satisfaction of the attending MI. 46 CFR 144.820
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 13 May 2025
Resolution: received pictures
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024 Resolved
Each lifejacket must be marked: In block capital letters with the name of the vessel. MI inspected life jackets in galley were not marked with vessels name. Make repairs to the satisfaction of the attending MI. 46 CFR 141.340
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 12 May 2025
Resolution: Recived photo evidance from [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024 Resolved
Stowage positions for life jackets stowed in a berthing space or stateroom and all life jacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the life jackets stowed inside the container. MI witnessed the life jackets stored the galley were not marked on quantity and location. Make repairs to the satisfaction of the attending MI. 46 CFR 141.340
Action required: 705 - Other - as specified
Due 10 December 2024
Resolved 12 May 2025
Resolution: Recived photo evidance from [name withheld]
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 November 2023 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Shutoff valve does not close fully.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 31 January 2024
Resolution: Received evidence of correction.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 October 2023 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The compass or swing-meter must be readable from each operating station. Vessel does not have a compass.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2023
Resolved 25 January 2024
Resolution: Received evidence of correction.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2023 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Rail posts are rusted at deck joints excessively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 27 November 2023
Resolution: Pictures sent.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 October 2023 Resolved
Search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. Starboard search light does not illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 31 January 2024
Resolution: Received evidence of correction.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 October 2023 Resolved
The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. Starboard fire hose nozzle is cracked and leaking water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 27 November 2023
Resolution: Nozzle replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2023 Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move. Locker is not secured to the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 2 February 2024
Resolution: Photos sent showing issue resolved
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 October 2023 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Mast light does not illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 31 January 2024
Resolution: Received evidence of correction.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 October 2023 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Bilge contains excess oily water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 31 January 2024
Resolution: Received evidence of correction.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 6 October 2023 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting is not present in berthing or heads.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 2 February 2024
Resolution: Photos sent showing issue resolved
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2023 Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy. Water light line is shorter than 3 feet.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 31 January 2024
Resolution: Received evidence of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical junction boxes in engine room and above bridge do not have covers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2023
Resolved 2 February 2024
Resolution: Photos sent showing issue resolved
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2021 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. The fuel oil filter on both generators were missing the heat shield. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 142.220
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2021
Resolved 29 November 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 November 2021 Resolved
Failure to meet Certificate of Inspection posting requirements. All 3 pages of COI were together in one picture frame. Each page of the COI must be visible, so each page should be in it's own frame and posted in a conspicuous place on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 November 2021 Resolved
Inspections and tests of lifesaving equipment must be recorded in the TVR or official logbook. There were no records on board of lifesaving equipment maintenance or tests.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2021 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. The fuel oil filter on both generators were missing the heat shield. Repair to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 November 2021 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical breaker panel outside of deckhand stateroom was missing labels. Label panel to the satisfaction of the Marine Inspector. 46 CFR 143.400(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Properly labeled the electrical breaker panel.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 19 November 2021 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Bridge alarm panel and Engine Room alarm panel was missing labels and some of the lights are burnt/inoperable. Label panel properly and fix lights to the satisfaction of the Marine Inspector. 46 CFR 137.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Properly labeled Bridge alarm panel and engine room panel. Also fixed the lights on the bridge panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2021 Resolved
Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket. Each life jacket must have a whistle firmly secured by a cord to the life jacket. Life jacket in deckhand stateroom is missing light and whistle. Attach appropriate light and whistle to life jacket to the satisfaction of the Marine Inspector. 46 CFR 141.340(g)(1) and 46 CFR 141.340(g)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Put a light and whistle on the life jacket.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 19 November 2021 Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Multiple external deck lighting had cracked housing or lenses. Not suitable for marine environment and should be replaced to the satisfaction of the Marine Inspector. 46 CFR 143.410(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Installed new lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2021 Resolved
The Master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The life jacket located in skiff is dry-rotted and not ready for use. Replace life jacket to the satisfaction of the Marine Inspector. 46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Bought a new life jacket.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 November 2021 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions or the Towing Safety Management System (TSMS) applicable to the vessel, if the vessel has a TSMS. The fire pump pressure was inadequate. Repair to the satisfaction of the Marine Inspector. 46 CFR 143.245(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Fire pump was wired wrong, reinstalled and pressure was able to build up properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 November 2021 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal operation and emergency conditions. There was a raw water leak on the port main diesel engine, and the flexible hose on the steering great actuator has excessive deterioration. Repair to ensure proper operation of the systems, to the satisfaction of the Marine Inspector. 46 CFR 143.205 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Fixed raw water leak, replaced the hose on the steering actuator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 November 2021 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. Number 1 bilge pump shaft seal is compromised. Repair to ensure proper operation of the systems to the satisfaction of the Marine Inspector. 46 CFR 143.275
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Replaced gasket in shaft seal to stop leak.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 19 November 2021 Resolved
The Owner, managing operator, or master must ensure that all persons on board a towing vessel comply with the health and safety plan. The donning placard for life jackets throughout the vessel are not correct. This is a safety hazard and the appropriate placards should be used to ensure the safety of crew members. Replace placards to the satisfaction of the Marine Inspector. 46 CFR 140.500(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2021
Resolved 29 November 2021
Resolution: Put up the proper placards for donning life jacket.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 November 2021 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Observed that multiple items in the First Aid kits that were expired. 46 CFR 140.435
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 December 2021
Resolved 29 November 2021
Resolution: Bought new first aid kit.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 19 November 2021 Resolved
The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup, and all towing vessels must have at least one properly installed VHF in addition. There was no battery backup for communications on board in the event of a loss of power.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2019 Resolved
"The TPO and the owner or managing operator may be required to explain or otherwise demonstrate areas of the TSMS to the Coast Guard if there is evidence that a TSMS, for which a TSMS certificate was issued, is not in compliance with the provisions of this part. The Coast Guard may require a third party’s attendance at the vessel or the office of the owner or managing operator for this purpose." As a result of the USCG inspection on 26JUN2019, our findings indicated clear grounds exist to request the TPO Meridian Global Consulting LLC to conduct an external management audit on American Tugs Inc, as evident from: 1) a direct discrepancy between cleared items on the 31JAN2019 vessel survey with similar deficiencies found during the 11APR2019 vessel audit, and 2) on board deficiencies identified by the USCG on 26JUN2019 indicated a serious failure/lack of effectiveness of the company's safety management system. During the management audit, particular attention should be given to proper corrective action under the "Observations & Non-conformities" section within their Safety Management Manual. 46 CFR 138.510
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 29 July 2019
Resolution: See Narrative
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2019 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be operable from a safe place outside the space where the valve is installed. The remote shutoff valve was frozen, & unable to be closed in the event of an emergency, unresolved since id'd by TPO on Apr 11, 2019. 46 CFR 143.260(d)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 27 June 2019
Resolution: Coast Guard attended the vessel and witnessed operation of fuel shut off valve. All found Sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 June 2019 Resolved
A fixed fire pump must be capable of being energized remotely from a safe place outside the engine room and at the pump. The fire pump was not capable of being actuated from the pump, no local controls present. 46 CFR 142.325(a)(2)
Action required: 30 - Ship detained
Resolved 3 July 2019
Resolution: Energized fire pump locally and remotely. Operation sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 June 2019 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. The fire station nozzle was not capable of providing a sufficient solid stream pattern needed to extinguish onboard fires. 46 CFR 142.325(d)
Condition: Invalid
Action required: 30 - Ship detained
Resolved 3 July 2019
Resolution: Fire nozzle were renewed, made of bronze, and provided sufficient strength.
Navigation
Issued 1 April 1996 Resolved
INCORRECT NAME AND HAILING PORT ON BOW, STERN OF VSL.
Condition: Unknown
Due 2 April 1996
Resolved 2 April 1996
Navigation
Issued 1 April 1996 Resolved
FORWARD MASTHEAD LIGHT MUST BE 1 METER ABOVE RUNNING LIGHTS.
Condition: Unknown
Due 2 April 1996
Resolved 2 April 1996
Documentation
Issued 1 April 1996 Resolved
INCOMPLETE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 2 April 1996
Resolved 2 April 1996
Accommodation/Occupational Safety
Issued 1 April 1996 Resolved
ONE TOILET ONBOARD HAD DIRECT DISCHARGE CAPABILITY.
Condition: Unknown
Due 2 April 1996
Resolved 2 April 1996