Records from 2016 to 2025. Most recent: inspection, 22 September 2025.
Inspection history · 25
22 September 2025
Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8239220
1 May 2025
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8126804
4 October 2024
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8017490
19 September 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8007769
16 September 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8003677
6 June 2023
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694232
24 May 2023
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7700327
25 April 2023
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7675457
7 April 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7664844
13 October 2022
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7576363
12 October 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7640413
13 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7557748
24 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7401181
21 June 2021
Drydock Exam · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7231425
5 June 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6981311
24 May 2020
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6961549
24 May 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6961794
17 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6927917
30 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6845707
3 January 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6605061
18 September 2018
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6544158
20 August 2018
Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6573182
29 June 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6472976
10 January 2018
MTSA Verification · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6335944
21 December 2016
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6060819
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2025
Resolved
ent outlets from all tanks which may emit flammable or combustible vapors, such as bilge slop tanks and contaminated drain tanks, must be fitted with a single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two screens of at least 20 by 20 mesh spaced not less than 1/2" nor more than 1.5" apart.
Port aft day tank flame screen was painted & and not seated properly in housing.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 September 2025
Resolution: Replaced screens with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2025
Resolved
Each lifebuoy must be marked in block capital letters with the name of the OSV and the name of the port required to be marked on the stern of the OSV. Name of port on bow lifebuoy was faded.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 September 2025
Resolution: Remarked lifebouy.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 September 2024
Resolved
Each piping penetration, in each bulkhead required by this subchapter to be watertight, must meet the requirements for materials and pressure design of
subchapter F of this chapter. MI observed multiple large
holes in bulkhead wire penetrations through forward engine room bulkhead.
46 CFR 128.230
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs. Rox blox installed
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 19 September 2024
Resolved
Alterations and repairs to inspected vessels must be done—(1) Under the direction of the Officer in Charge, Marine Inspection. MI observed unauthorized repairs being made to the emergency hatch leading out of the engine room affecting the vessel's load line survey and certificate. There were also modifications to the moon pool enclosure, observed to be welded shut calling into question the validity of the vessels current stability letter. Applicable plans shall be submitted for review and approval by MSC/ABS and vessels stability letter/stability booklet must be updated to reflect and address the moon pool modification, and the removal of the PAM.
46 CFR 170.005
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 September 2024
Resolved
This section applies to each vessel with watertight doors in bulkheads made watertight in compliance with this chapter. A Class-1 door may be installed at any place if—(1) The door has a quick-acting closing-device operative from both sides of the door;(2) The door is designed to withstand a head of water equivalent to the depth from the sill of the door to the bulkhead deck or 3 meters (10 feet), whichever is greater; and(3) The vessel's pilothouse contains a visual indicator showing whether the door is open or closed. MI observed no visual indicator in the pilothouse to indicate whether the doors were opened or closed. Although the bridge panel was updated there was no indicator to determine whether doors were closed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs. Alarms SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2024
Resolved
Each connection to a conductor or a terminal part of a conductor must be made within an enclosure. MI observed multiple dead end wiring without proper termination throughout the engine room.
46 CFR 129.340 (g)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed exposed wiring removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 September 2024
Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety relief valves on all pressure vessels, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. MI observed both pressure vessel's safety relief valves had not been tested since June 2021.
46 CFR 61.10-5 (i)(2)
Condition: Invalid
Action required: 30 - Ship detained
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed saftey valves were tested/replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2024
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead-front type. Breaker panel in the engine room was found with openings in the front, and outside front panel not properly secured.
46 CFR 129.330 (e)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2024
Resolved
Exhausts of internal-combustion engines, galley uptakes, and similar sources of ignition must be kept clear of and insulated from woodwork and other combustible matter. MI observed the stbd MDE was missing lagging on exhaust in the vicinity of the turbocharger.
46 CFR 127.220 (b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 September 2024
Resolved
Each closing appliance must remain watertight under the design water pressure of the watertight boundary of which it is a part. Vessel's aft watertight door in the egine room did not fully seat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs door is watertight
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 19 September 2024
Resolved
Vessel must maintain a ballast water managment (BWM) Plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of this subpart. Vessel does not have a BWMS and informed the attending MI that they use municipal water. The vessel's current plan on board that was provided did not reflect what the vessel's currently practices.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 30 September 2024
Resolution: Vessel rep provided proof to our office via email of corrected, updated, vessel specific, Ballast Water Management (BWM) plan.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 September 2024
Resolved
Each battery must be located as high above the bilge as practicable within the space the battery is located in and be secured to protect against shifting due to roll, pitch, and heave motions or vibration of the vessel. Vessel's battery installation for the STBD MDE was not properly secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs battery is secured
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 September 2024
Resolved
Each watertight door in a bulkhead that must be watertight in compliance with the requirements in part 174 of this chapter, and each watertight hatch, must be marked on both sides in letters at least 50 millimeters (2 inches) high that state the following: “WATERTIGHT DOOR—KEEP CLOSED EXCEPT FOR PASSAGE” or “WATERTIGHT HATCH—KEEP CLOSED WHEN NOT IN USE”. Vessel's watertight doors were not labeled on both sides of the door.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory labeling on doors
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 September 2024
Resolved
vessel may install fire extinguishing equipment beyond that required by this subchapter, and maintained in accordance with an appropriate industry standard and and must be designed, installed, tested,the manufacturer's specific guidance. Vessel's fire monitor pump was found to be leaking excessively from both packing glands. Vessel shall not energize fire monitor or operate in stand-by vessel capacity until fire monitor leak is secured. NLT 30 days to rectify.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2024
Resolved 2 May 2025
Resolution: Tested fire monitor pump at the pier no leaks on the packing glands.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 September 2024
Resolved
A rudder-angle indicator independent of the control of the main steering gear must be installed at the steering-control station in the pilothouse. Vessel's RAI in the engine room was off by 10 degrees from the RAI on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 24 September 2024
Resolution: Marine Inspector attended vsl on 24SEP2024 and observed satisfactory repairs RAI is corrected and no longer inaccurate.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 16 September 2024
Resolved
Alterations and repairs to inspected vessels must be done—(1) Under the direction of the Officer in Charge, Marine Inspection. MI observed an unauthorized repair made to the bilge pipping arrangement posing a down flooding risk; affecting the vessel's load line survey and certificate. The pipe shall be removed from the spool piece or provide approved drawings from USCG MSC and or ABS for proper installation oversight. This requirement has also been noted on ABS short term load line certificate issued 21 SEP 2024. Rectify within 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 September 2024
Resolution: Vessel rep provided proof to our office via email of photograph of corrected bilge piping arrangement.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 20 June 2023
Resolved
Vessel must comply with applicable requirements for any radio requirements set forth in 47CFR part 80. Vessel had damage to SSB radio from lighting strike.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2023
Resolution: Provided Tech report to clear Deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 June 2023
Resolved
Each fire detector and control until must be approved and maintained. PAM fire detection panel had a system fault. Vessel provided tech report.
Action required: 10 - Deficiency Rectified
Resolved 21 June 2023
Resolution: Vessel rep provided techreport to show system was fixed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 June 2023
Resolved
Immediately after addressing safety concerns, the owner, agent, master, operator, or PIC shall notify the nearest Sector or OCMI involving: (4) occurence materially and adversely affecting the vessels seaworthiness or fitness for service. Vessel had a lighting strike that damaged the SSB radio and other electrical equipment on the bridge. Educated Owner/Operator Mgmt, vessel rep, and Masters.
Action required: 10 - Deficiency Rectified
Resolved 21 June 2023
Resolution: MI educated Operator Mgmt, Vessel Rep, and both Masters about requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2022
Resolved
The MARCELLE BORDELON is authorized to transit from its current location offshore to Bollinger Shipyard in AMELIA, LA. The vessel shall communicate noteworthy changes in operating condition during transit to the cognizant OCMI in whose zone they are in. The MARCELLE BORDELON is to contact MSU MORGAN CITY and VTS upon entering and exiting their area of responsibility. The vessel is not to depart the Morgan City Area of Responsibility until USCG personnel at MSU MORGAN CITY have been notified and have delivered further guidance.
Morgan City Officer of the Day can be contacted at [phone withheld].
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 21 October 2022
Resolution: Verified generator was operational.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 21 June 2021
Resolved
Fire/Safety Plan was not accurate or approved by the CG or an RO. 46 CFR 131.945
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 23 June 2021
Resolution: Attended vsl and approved/stamped all fire safety plans.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 October 2019
Resolved
Each enclosed space must have a means to close. Vent from main deck to gally was unable to close. 46 CFR 127.250(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 21 November 2019
Resolution: Layers of paint removed. It is able to be closed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 October 2019
Resolved
PV valves shall conform to subchapter Q. PV valve is painted over and is unable to function. Vessel shall have PV valve serviced prior to carriage of cargo (Methanol, LDHI) in tanks. 46 CFR 153.368(h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 10 January 2018
Resolved
Replace all unapproved plastic Racor fuel oil filter/strainers with fluid conditioner fittings meeting ASTM 1201 as required by 46 CFR 128.110 and 46 CFR 56.15-5.
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 22 January 2018
Resolution: Replaced unapproved Racor fuel oil filter/strainer bowls with ASTM 1201 approved fittings.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 January 2018
Resolved
Rudder angle indicators at the bridge and engine room locations are not aligned and deviate from each other by up to 13 degrees. Calibrate rudder angle indicators so they are accurate and aligned (linear).
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 12 January 2018
Resolution: Third party vendor Beier Radio attended vessel, replaced starboard aft bridge station RAI, and calibrated all RAIs so all aligned with rudder and within 0-4 degreees of each other at all stations.
Engineering › Lubricating Oil Service System › Hose
Issued 10 January 2018
Resolved
Fit leaking flexible piping (hoses) on main diesel engines with double hose clamps.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2018
Resolved 10 January 2018
Resolution: Installed double hose clamps and proved leak-free prior to completion of inspection.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 21 December 2016
Resolved
Show proper operation of ground indicators on switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2016
Resolved 21 December 2016
Resolution: Bulb changed on switchboard
Engineering › Compressed Air System (control) › Valve
Issued 21 December 2016
Resolved
Provide service certificate or provide new pressure relief valves for air receivers.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 December 2016
Resolved 28 December 2016
Resolution: New pressure relief valves were installed.
Engineering › Compressed Air System (control) › Fitting
Issued 21 December 2016
Resolved
Provide proper gauges for air receivers in accordance with 46 CFR 54.15-5(f).
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 21 December 2016
Resolution: Gauges changed out
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 21 December 2016
Resolved
Adjust watertight door in engine room.
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 21 December 2016
Resolution: Door adjusted
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 December 2016
Resolved
Provide proper transfer procedures for fuel/oil cargo in accordance with 33 CFR 155.750.
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 16 January 2017
Resolution: Proper Transfer Procedures were written
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 December 2016
Resolved
Provide guard on rotating machinery in way of bow thruster.
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 21 December 2016
Resolution: Guard was manufactured and installed.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 21 December 2016
Resolved
Clean containment and stop leak from fuel/oil fill line and no others.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2016
Resolved 21 December 2016
Resolution: Containment cleaned out and camlock fitting was changed out.