Records from 1999 to 2026. Most recent: inspection, 17 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)66.5 ft × 24.0 ft × 9.9 ft
Registered tonnagegross 154 / net 104
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHERN SHIPBUILDING CORP · SLIDELL, LA, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPADUCAH, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it104 - Regulatory (Subpart C or D), Net Ton
154 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
46 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; 29 vessels inspected with it, by name and date; 3 other recorded names, with years; 13 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 46
17 August 2026
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8466557
6 July 2026
MTSA Verification · Vessel Attendance · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8430964
16 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8235226
28 August 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7991239
2 August 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7972973
21 June 2024
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7939684
2 August 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7758974
20 October 2022
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7581060
26 July 2021
COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7268492
27 June 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7314439
7 April 2021
Damage Survey · TPO Audit
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7170730
7 April 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7241585
7 April 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7241596
9 December 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7116899
28 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6843383
17 April 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6664848
26 March 2019
Initial Certification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6649315
23 January 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6614300
15 February 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6360541
12 November 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6308183
20 September 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6285801
27 June 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333332
5 December 2015
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5776073
8 August 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5212823
28 January 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5063790
10 December 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4499488
25 January 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4232070
19 January 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4229795
8 September 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3845497
7 September 2010
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3845515
31 August 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3865125
2 May 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3769642
19 July 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2145427
25 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2012798
24 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2012362
29 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1971144
28 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1970307
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979295
18 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982078
28 November 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1955751
28 November 2003
Uninspected Towing Vessel
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1956297
4 December 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1766309
9 March 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 18124
9 March 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 287972
20 November 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 100328
12 December 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185412
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2026
Resolved
Lifejackets must have the following attachments and fittings: Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Nine lifejacket lights were found with an expiration date of 02/2026. The vessel shall replace all expired lights within 14 days and ensure a daily operational test is performed on all lifejacket lights until replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2026
Resolved 21 July 2026
Resolution: Rep purchased new lights for the jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2026
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. All lifebuoy lights were found to have incorrect batteries installed, rendering the lights non-compliant with the approval series listed above. The vessel shall ensure that all lights have the proper Energizer L91 batteries installed within 14 days and that a daily operational test is performed on each light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2026
Resolved 21 July 2026
Resolution: The approved batteries were installed and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2023
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backfloogin through bilge piping. Install check/foot valve in E/R bilge suciton. To be completed at vessel's next scheduled dry dock exam.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2023
Resolved 23 August 2023
Resolution: Check valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 July 2021
Resolved
Towing vessels must perform alarm test set points twice every five years. Complete alarm set point testing for machinery alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 18 August 2021
Resolution: Rec'd tech report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2021
Resolved
Piping for seawater cooling must be fitted with isolation valves that are clearly marked by labeling or color coding. Label or color code cooling isolation valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 2 August 2021
Resolution: Piping marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2021
Resolved
Electrical systems must be designed and maintained to provide for safe operation. Repair or replace breaker box door in machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 18 August 2021
Resolution: Door repaired.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 7 April 2021
Resolved
The management must demonstrate that they implemented the policies and procedures contained in the TSMS and the entire organization is adhering to their safety management program.
Company was notified of water ingress into vessels stern void through vessels side shell October 15 2020. Issue remains unresolved.
A targeted external management audit shall be carried out by TPO prior to vessel being released from detention. Audit shall focus on 46 CFR 138.220(a)(2)(ii)and (b)(2).
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 30 May 2021
Resolved 13 May 2021
Resolution: A successful targeted external management audit was carried out by TPO
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 April 2021
Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to the hull plating or structural members that may affect the seaworthiness of the vessel. Vessel must submit voyage plan for approval to transit to dry dock, and upon approval from the OCMI proceed to dry dock for further examination and to affect repairs.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2021
Resolved 13 May 2021
Resolution: TPO verified proper repair
Stability › Watertight Integrity
Issued 28 November 2003
Resolved
Vessel was taking on water which flooded stern void from a 20 inch long fracture in the hull on the starboard quarter. Issued COTP order 03-097 requiring permanent repairs. LEGACY COMPONENT DESC: Hull
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 30 November 2003
Resolution: Received 3rd party report attesting to sat repairs. Vessel welded doubler plate over the fractured area.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 28 November 2003
Resolved
Stern tube leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 30 November 2003
Resolution: Tightened packing on stern tube.
Engineering › Bilge Water Management System
Issued 28 November 2003
Resolved
During flooding of stern void, about 6 inches of water entered engineroom via the stuffing tube between the two spaces. Properly dispose of all engineroom bilge waste prior to placing vessel back in service.
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 30 November 2003
Resolution: Pumped bilges at Buffalo Marine.
Stability › Watertight Integrity
Issued 28 November 2003
Resolved
Stuffing tube between the engineroom and the stern void must be repacked due to water leaking through tube during flooding of stern void. LEGACY COMPONENT DESC: Internal bulkheads
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 30 November 2003
Resolution: Repacked stuffing tube from both sides.