Records from 2009 to 2024. Most recent: inspection, 28 October 2024.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT, INC · JEFFERSONVILLE, IN, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
28 October 2024
Examination of Repairs · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8026066
20 January 2024
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7851943
10 January 2023
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7616309
9 November 2021
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7354189
21 October 2019
Drydock Exam · Examination of Repairs · MTSA Verification · COI Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6828108
6 December 2018
Annual Survey · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6593280
7 December 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6320115
31 July 2017
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6221443
12 June 2017
Damage Survey · Permit to Proceed · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6173337
11 June 2017
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6177752
6 January 2017
Periodic Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6065845
29 September 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5731815
7 October 2014
COI Inspection · Examination of Repairs · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4997374
13 February 2014
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4799481
21 December 2012
Examination of Repairs · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4505563
10 December 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4499488
10 December 2012
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4500692
12 July 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4376677
29 May 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4327182
2 December 2011
Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4198544
28 November 2011
MTSA Verification · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4196574
27 June 2011
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4059584
11 January 2011
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3924797
20 December 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3666608
24 August 2009
Internal Structural Exam · Hull Examination · MTSA Verification · Cargo Tank Internal · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3615220
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 December 2018
Resolved
Port and STBD cargo pump prime mover would not shut down when emergency pulls pulled. Conduct repairs to both Port and STBD cargo pump prime mover prior to cargo operations. 46 cfr 2.01-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2018
Resolved 7 December 2018
Resolution: both cableways were filled with water that froze with weather. Thawed out cableways, tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 December 2018
Resolved
Test thermal fluid heater alarms, low fuel psi, low fluid psi, high temp prior to conducting cargo operations. 46 CFR 52.25-15
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2018
Resolved 7 December 2018
Resolution: Valcanic rep came out and tested all 3 shutdowns listed above.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 December 2018
Resolved
Found damage to port side stern at waterline and port side #1 wing void at bilge knuckle that needs futher inspection prior to cargo operations. 46 CFR 2.01-10
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2018
Resolved 7 December 2018
Resolution: Damage is at the max allowed in accordance with D8 barge and repair guide. Vessel will be due for its ISE and drydock in 2019.
Construction/Loadline › Hull › Side Shell
Issued 12 June 2017
Resolved
#1 port wing void has sideshell damage and damage to all associated internal framing. crop and renew to satisfaction of attending CG marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 31 July 2017
Resolution: Inspected satisfactory repairs.
Construction/Loadline › Hull › Hull Plating
Issued 10 December 2012
Resolved
Possible damage to hull plating - damage to side longs and floor frame and bulkhead in #1 Port wing tank. Proceed to Houston, TX for offload and proceed to nearest shipyard for repairs.
Action required: 705 - Other - as specified
Due 29 December 2012
Resolved 21 December 2012
Resolution: Repairs were made to #1 Port Wing Tank bilge knuckle and transition knuckle inserting new plate. See narrative.
Electrical › Electric Supply System (service) › Cable
Issued 28 November 2011
Resolved
Demonstrate sounding cable/wire that runs across top of barge through cargo area meets requirements for wiring located in a hazardous location or permanately remove from barge. § 111.105-3 General requirements. All electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE 45-1998 (incorporated by reference; see 46 CFR 110.10-1), and with either
Condition: Improper Installation
Due 30 November 2011
Resolved 30 November 2011
Resolution: Vessel personnel removed sounding cable/wire from the barge
Construction/Loadline › Hull › Double Hull
Issued 28 November 2011
Resolved
While conducting visual inspection of the #4 stbd void, cargo seepage was detected in the void near the forward most hatch. Properly assess area and report findings to cognizant OCMI within 30 days.
Due 30 December 2011
Resolved 2 December 2011
Resolution: Repaired pin hole cargo leak in #4 stbd void.