Records from 1995 to 2026. Most recent: inspection, 23 February 2026.
Documentation record
Registered dimensions (L × B × D)49.6 ft × 17.6 ft × 6.4 ft
Registered tonnagegross 41 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMATERIAL SERV CORP · LOCKPORT, IL, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHENDERSON, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
23 February 2026
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8314339
9 January 2025
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8048377
24 June 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7941236
18 June 2024
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7921390
24 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7900664
11 September 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7789299
15 May 2023
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7688664
2 March 2022
COI Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7399668
17 November 2021
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7353759
10 November 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7090002
26 April 2019
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6670806
24 October 2017
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6294776
17 December 2015
Industry Initiated Exam · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5791949
8 July 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4649989
29 November 2011
Industry Initiated Exam · Deficiency Check · Administration · MTSA Verification · DAPI Audit
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4198127
6 May 2009
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3469058
30 January 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2576136
2 November 2005
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2527794
20 September 2005
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2499998
9 September 2005
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2487933
21 May 2004
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2097992
1 July 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1639689
14 September 1998
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 12973
29 October 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 409536
13 June 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 755598
9 June 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 190966
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 May 2023
Resolved
They have flares onboard but they are the red parachute flares listed under 160.066/34/2. These do not meet the regs.
(b)Day and night visual distress signals. Hand-held red flare distress signals, approved under approval series 160.021 or 160.121, and hand-held rocket-propelled parachute red flares, approved under approval series 160.036 or 160.136, are acceptable as both day and night signals.
(c) Signals for day visual distress only. Floating orange smoke signals, approved under approval series 160.022, 160.122, or 160.157, and hand-held orange smoke distress signals, approved under approval series 160.037, are only acceptable as day signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 12 September 2023
Resolution: New Flares have been placed on board the ITV
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 May 2023
Resolved
They need to get an updated light list onboard, the last update portion of the light list for the area they operate in, is a copy from 2012.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 12 September 2023
Resolution: Placed a new copy of a light list on board the ITV
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2023
Resolved
Bilge alarm was only visual at operating station. Need to also be audible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 12 September 2023
Resolution: Bilge alram was audible and visual at operating station
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 March 2022
Resolved
Vessel does not have a stability letter or a statement of historical satisfactory service, in accordance with 46 CFR 144.300.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 16 March 2022
Resolution: Received a stability letter statement of historical satisfactory service, SAT
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 2 March 2022
Resolved
Ladder from aft maindeck to 2nd deck is not adequately secured to vsl (missing bracket on top left side). Provide proper securing device for ladder in accordance with 46 CFR 144.700.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 16 March 2022
Resolution: fastened the Ladder where it was missing support.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2022
Resolved
Ensure all Ring Life Bouy (RLB) on vessel are CG approved and have adequate retro-reflective tape. Also, bridge wing RLB missing floating electric light. Install floating light in accordance with 46CFR 141.360.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 16 March 2022
Resolution: added a Light with lanyard, and new reflective tape.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2022
Resolved
Portable and Semi-portable fire extiguishers must be inspected and logged each month in accordance with 46CFR 142.240. Ensure going forward monthly inspection are completed and logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 16 March 2022
Resolution: Company as added to thier Fire Drills that they sign and date all extinguishers during their monthly fire drills.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2022
Resolved
Semi-portable B-160 fire extiguisher on aft deck need to be properly secured to prevent it from shifting around.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 16 March 2022
Resolution: Installed a brace to secure B-160 fire extinguisher from shifting around.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2022
Resolved
Vessel was missing an adequate flammable storage locker and additional 40-B fire extinguisher nearby. 46CFR225
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 16 March 2022
Resolution: Company added a Flammable storage Box and mounted a 40-B fire extinguisher beside it.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 2 November 2005
Resolved
Provide proof that fire detection system is certified by a professional engineer or classification society as required under 46CFR 27.203 (g)
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2006
Resolved 30 January 2006
Fire Fighting › Fixed Fire Detection System › Approval
Issued 22 September 2005
Resolved
Provide proof that fire detection system is certified by a Professional Engineer or Classification Society as required under 46 CFR 27.203(g)
Condition: Unknown
Due 22 October 2005
Resolved 30 January 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 September 2005
Resolved
Recent copy of Coast Guard Light List needed on board as required under 33 CFR 164.72 (b)(1)
Condition: Unknown
Due 20 October 2005
Resolved 2 November 2005
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 20 September 2005
Resolved
Coast Guard Local Notice to Mariners needed on board as required under 33 CFR 164.72 (b)(2)
Condition: Unknown
Due 20 October 2005
Resolved 2 November 2005
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 September 2005
Resolved
Recent copy of Inland Nav.Rules needed on board as required under 33 CFR 88.05
Condition: Unknown
Due 20 October 2005
Resolved 2 November 2005
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 20 September 2005
Resolved
Proper amount of reflective material needed on Ring Buoy as required under 46 CFR 25.25-5(d)
Condition: Improper/Lack of Maintenance
Due 20 October 2005
Resolved 2 November 2005
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 20 September 2005
Resolved
Name of Vessel and Hailing Port needs to be displayed on stern as required under 46 CFR 67.123
Condition: Unknown
Due 20 October 2005
Resolved 2 November 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 September 2005
Resolved
Guards need to be placed over Port and Starboard engine tail shafts "Good Marine Practice"
Condition: Unknown
Due 20 October 2005
Resolved 2 November 2005