MAURY USCG vessel records
← All vessels

NALE

Built
2007
Last inspected
6 May 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 6 May 2025
…with no type recorded45
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2007–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

847732
Flag
UNITED STATES
Maury page id
psix-847732

Documentation record

Registered dimensions (L × B × D)349.9 ft × 78.0 ft × 30.0 ft
Registered tonnagegross 6,508 / net 4,163
ITC dimensions (L × B × D)349.9 ft × 78.0 ft × 30.0 ft
ITC tonnagegross 6,508 / net 4,163
BuilderZIDELL MARINE CORPORATION · PORTLAND, OR, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 16 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15775 - Dead Weight, Net Ton
4163 - Convention (Subpart B), Net Ton
6508 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 79 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NAKOLO Towing Vessel · MISLE 128649 · 30 May 2015 · activity 5144579NE'ENA Tank Barge · MISLE 720413 · 9 September 2014 · activity 4979261MEDITERRANEAN DAWN Towing Vessel · MISLE 140883 · 26 December 2012 · activity 4507518JIMMY SMITH Towing Vessel · MISLE 144924 · 9 August 2012 · activity 4407336TOLOA Towing Vessel · MISLE 336739 · 9 August 2012 · activity 4407336

Inspection history · 79

6 May 2025 Internal Structural Exam · Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8129997
19 July 2024 MARPOL Annex I Examination · COI Inspection · MARPOL Annex VI Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7953560
31 March 2024 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7888322
6 March 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7895886
22 June 2023 Annual Survey · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7714637
21 November 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7598732
8 November 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7592374
5 May 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7445684
8 February 2022 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7393873
11 October 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7331501
29 May 2020 MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6962815
11 May 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6951724
3 March 2020 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6916008
8 September 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6809667
25 July 2019 COI Inspection · Deficiency Check · MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6761160
24 July 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6761115
2 May 2019 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6675401
28 August 2018 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6525937
25 May 2018 Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6431760
4 April 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6386222
27 July 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6222975
12 April 2017 COI Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6121665
16 February 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084768
5 January 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6066069
13 June 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5906317
19 June 2015 Periodic Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5148969
30 May 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5144579
19 February 2015 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5067299
30 October 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5015952
9 September 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4979261
12 May 2014 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4857056
7 April 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4831172
27 November 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4760039
17 October 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4737092
16 October 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4735839
6 October 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4730522
15 August 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4686033
6 August 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4679393
26 December 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4507518
25 September 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4450165
9 August 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4407336
21 June 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4351651
16 May 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4313528
27 February 2012 Hull Examination · MARPOL Annex I Examination · Internal Structural Exam · COI Inspection · Re-Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4251899
25 January 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4231825
23 November 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4194747
12 October 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4166860
9 September 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4140299
24 August 2011 Administrative Inspection · Damage Survey · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4126176
5 August 2011 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4105243
28 July 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4097287
29 June 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4062278
29 December 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3917625
3 December 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3903936
18 November 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3894011
15 September 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3851365
28 July 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3808793
1 July 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3782775
24 June 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3775625
20 May 2010 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3742392
21 April 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3721815
12 March 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3694690
24 February 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3685419
27 January 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3671051
17 September 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3596920
27 August 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3578742
14 August 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3562189
10 June 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3501140
26 February 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3431825
10 December 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3377929
6 December 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3375772
3 December 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3373660
21 August 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3302375
3 August 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3290225
27 July 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3282566
26 February 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3154280
1 January 2008 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3123384
29 June 2007 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2981117
30 May 2007 MARPOL Annex I Examination · Initial Certification · Internal Structural Exam · Construction Oversight
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2787567

Deficiency record · 28

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 March 2024 Resolved
No extensive repairs to the hull shall be made without the knowledge of the Officer in Charge, Marine Inspection. There is a large inset and cracked weld on the aft port skeg. Complete permanent repairs to the satisfaction of the attending Marine Inspector. 46 CFR 31.10-25
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2024
Resolution: Witnessed satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 22 June 2023 Resolved
Shutoff valves shall be installed in the fuel supply lines, one as close to each tank as practicable, and one as close to each fuel pump as practicable. Valves shall be accessible at all times. Neither port nor starboard fuel shut off valves fully closed. Adjust valves to close fully. 46 CFR 56.50-75(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2023
Resolution: Shut of valves readjusted and operate properly.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 22 June 2023 Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. Identified inoperable overspeed device on the #2 generator. Repair the overspeed device on the #2 generator. 46 CFR 111.12-1(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2023
Resolution: Corrected overspeed on #2 generator.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 22 June 2023 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03–1), except as otherwise provided by this subchapter. For propulsion machinery spaces intended for centralized or unattended operations, alarms for abnormal conditions (pressure and temperature) of the cooling media and automatic safety system functions are to be provided. Identified inoperable high jacket water temperature alarm. Fix the high jacket water temp alarm. 46 CFR 58.05-1(a) ABS 4-6-5/7.7.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2023
Resolution: Jacket Water temperature alarm replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 June 2023 Resolved
Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided. Cargo Pump #2 gastight gland deteriorated beyond repair. Replace gastight gland. 46 CFR 32.50-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2023
Resolution: Gastight gland on teh #2 Cargo Pump replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 June 2023 Resolved
Each gasket must confirm to the design requirements of the applicable standards of table 56.60-1(b) of this part. Identified deteriorated gaskets on both aft rakes, port and starboard. Replace gasket material. 46 CFR 56.25-159 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2023
Resolution: Gaskets replaced on both rakes hatches.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2023 Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fire extinguishers had been serviced, as evidenced by their tags; however, the complement servicing records were not available during inspection. Provide current fire servicing records. 46 CFR 31.10-18
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2023
Resolution: Vessel rep provided fire servicing records.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2023 Resolved
The employer shall ensure that one or more persons in each type of operation conducted on the vessel which involves the handling of or potential exposure to benzene are monitored. The monitoring must be conducted so as to determine the representative personal exposure of all persons engaged in each particular operation involving benzene. Vessel failed to provide their benzene monitoring program during the inspection. Provide benzene monitoring program. 46 CFR 197.540(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2023
Resolution: Vessel rep provided their benzene monitoring program.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 February 2022 Resolved
No extensive repairs to the hull or machinery which affect the safety of a vessel shall be made without the knowledge of the Officer in Charge-Marine Inspection. #1, #2, & #3 bilge tripping brackets located at the rolled bilge strake between frames 45 & 46 in void 7 Port are tripped. Submit repair proposal to be reviewed & approved by attending USCG Marine Inspector. 46CFR31.10-25
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 9 February 2022
Resolution: Received repair proposal to leave brackets as no fractures were found once paint was removed.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Volatile organic compounds in tankers
Issued 11 October 2021 Resolved
Implement a VOC management plan approved by the Administration. The vessels Cargo Authority Attachment list "Oil, misc: Crude" as an authorized cargo, however the vessel does not have an approved VOC management plan. The vessel shall not carry crude oil as cargo until it has an approved and implemented VOC management plan. MARPOL VI/15.6
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 November 2021
Resolution: Sector Honolulu received verification of Approved VOC Management Plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 August 2019 Resolved
KIRBY OFFHSORE MARINE HAWAII LLC, the owner of the barge NALE (O.N. 1190335), and the operator KIRBY OFFSHORE MARINE, LLC failed to comply with a direction to terminate voyage, correct unsafe conditions, or make repairs on a vessel subjetct to inspection.
Action required: 705 - Other - as specified
Due 18 November 2019
Resolved 18 November 2019
Resolution: Resolved through civil penalty.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 25 July 2019 Resolved
Vapor collection (VCS) piping must be electrically bonded to the hull and must be electrically continuous. Vapor collection piping installation on the vessel is not electrically continuous. Install VCS electrical bonding between piping flanges and to hull. Vessel is restricted from conducting VCS operations until resolved.
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 11 May 2020
Resolution: An electrician tested the VCS piping for continuity. The results were uploaded to documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 25 July 2019 Resolved
A fixed pressure-sensing device must be installed as close as practicable to the vessel vapor connection on a tank barge with a vapor collection system. The pressure-sensing device must measure the pressure vacuum in the main vapor collection line and have a pressure indicator located where the cargo transfer is controlled. Starboard manifold is missing the fixed pressure-sensing device as close as practicable to the vessel vapor connection. Vessel is restricted from conducting VCS operations until resolved.
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 29 May 2020
Resolution: Pressure gauges were installed in proper location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2019 Resolved
All records required to be maintained by 46 CFR 197.570 must be made available upon request by to the Coast Guard. Operator failed to provide record of all benzene monitoring conducted in compliance with 46 CFR 197.540 for three years. Vessel is restricted from carrying liquid cargoes containing more than 0.5% benzene by volume. KIRBY OFFSHORE MARINE HAWAII LLC and KIRBY OFFSHORE MARINE, LLC failed to ensure compliance with requirements for benzene cargo as required by 46 CFR 197.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2019
Resolved 7 August 2019
Resolution: Operator provided benzene monitoring program, respiratory program, list of personnel enrolled in medical surveillance for benzene exposure, a contract for the company APEX to conduct benzene monitoring today while loading cargo.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 25 July 2019 Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. #2 SSDG is missing an adequate cover for the alternator belt. Install a belt cover in accordance with 46 CFR 58.01-20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 6 August 2019
Resolution: Adequate cover for the alternator belt on #2 SSDG installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 25 July 2019 Resolved
The applicable standards for construction of main and auxiliary machinery is established in ABS Steel Vessel Rules standards. The #1 and #5 cargo pump prime mover instrumentation panel are temporarily mounted. Permanently mount the instrumentation panels.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 6 August 2019
Resolution: The #1 and #5 cargo pump prime mover instrumentation panel are permanently mounted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 July 2019 Resolved
Machinery space ventilators in an exposed position on the free board or superstructure deck shall be capable of being secured weather tight. The Machinery house upper deck ventilation weather tight closures are missing dogs and hardware. Repair or replace the missing dogs and hardware.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 29 May 2020
Resolution: verified all hardware and dogs are installed for proper operation of closures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2019 Resolved
Diesel exhaust piping must conform to 46 CFR 58.10-10(a). The #1, #2, #3, #4, # 5 cargo pump prime mover exhaust overhead deck penetrations were found corroded/holed or have been repaired temporarily with an epoxy like substance. Submit a repair proposal to the cognizant OCMI to permanently repair the affected areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 29 May 2020
Resolution: All piping penetrations were replaced during yard period.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2019 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in 46 CFR 31.10-17(a) and (b) and your Certificate of Inspection must be endorsed. The vessel operator failed to request an inspection with the local U.S. Coast Guard OCMI as specified in 46 CFR 31.10-17(a) and (b). The vessel's Certificate of Inspection was last endorsed for an annual inspection on May 25, 2018. The Certificate of Inspection is no longer valid. Contact the nearest U.S. Coast Guard OCMI to schedule an inspection for certification as specified in 46 CFR 31.10-15.
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 25 July 2019
Resolution: Completed COI inspection. Issued Temp COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2019 Resolved
The vessel's "bunker light" caught fire and was destroyed. Replace the affected light in accordance with 46 CFR 110.01-3 and, to the satisfaction of the attending marine inspector, review system's wiring to insure it is intact and that there was no further damage to the system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2019
Resolved 7 May 2019
Resolution: Independent electrician and Class attended vessel. Vessel supplied pictures and tech reports attesting to the correction of the deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 12 April 2017 Resolved
1) Install gaskets in bulkhead penetrations for all cargo pump shafts.46 cfr 32.50-1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2017
Resolved 13 April 2017
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 12 April 2017 Resolved
2) Repair #2 starboard PV valve. 46CFR 32.55-25(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2017
Resolved 13 April 2017
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 12 April 2017 Resolved
3) Install flame screens on all void space vents. 46CFR 32.55-45
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 13 April 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 12 April 2017 Resolved
4) repair bravo light for transfers conducted between sunset + sunrise. Def cleared before inspectors departed. 33CFR155
Action required: 703 - Prior to bunkering operations
Due 21 April 2017
Resolved 13 April 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 12 April 2017 Resolved
5) Correct tank 4 crossover valve indicator. def corrected before inspectors departed.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 13 April 2017
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 7 April 2014 Resolved
Found Parker Hannifin Airpak 206-5, SAE J1402 hoses on all guages for cargo pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2014
Resolved 29 April 2014
Resolution: Company installed J1527 hoses but provided manufacturer info to show J1942 compliance.
Electrical › Electric Generation Source (service) › Generator
Issued 24 August 2011 Resolved
Prove proper operation of stbd generator prior to sailing to CG inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 August 2011
Resolved 25 August 2011
Deck/Cargo › Towing › Chocks
Issued 1 January 2008 Resolved
Repair (4) broken chocks on stern to the satisfaction of class and the attending USCG inspector by 31Jan2008.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2008
Resolved 7 February 2008

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.