MAURY USCG vessel records
← All vessels

RICHARDSON SEA

Built
2006
Last inspected
6 January 2026
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 6 January 2026
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 20 calendar years (2006–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL7245
850405
Flag
UNITED STATES
Maury page id
psix-850405

Documentation record

Registered dimensions (L × B × D)308.0 ft × 54.0 ft × 16.0 ft
Registered tonnagegross 2,235 / net 2,235
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2006
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg_nfv
DocumentationCase Pending · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2235 - Simplified, Gross Ton
2235 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 44 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LIGHTNING Towing Vessel · MISLE 1211246 · 9 May 2023 · activity 7684682ST ANDREWS Towing Vessel · MISLE 485714 · 29 December 2017 · activity 6330786MADDIE K Towing Vessel · MISLE 165701 · 13 November 2012 · activity 4487740HMS LIBERTY Towing Vessel · MISLE 164098 · 13 October 2010 · activity 3869314CHRESTENSEN SEA Tank Barge · MISLE 850406 · 13 October 2010 · activity 3869314

Inspection history · 44

6 January 2026 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8290163
11 December 2024 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8046031
28 June 2024 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7916356
25 October 2023 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7810996
9 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7684682
8 December 2022 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7606256
12 October 2021 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7331242
21 June 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7232094
21 October 2020 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7081457
2 September 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7066755
8 October 2019 Periodic Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6830383
20 November 2018 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6584001
30 May 2018 Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6423408
19 April 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394531
9 April 2018 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6388891
5 April 2018 Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6386001
30 December 2017 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6330553
29 December 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6330786
26 October 2017 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6294852
3 October 2016 Deficiency Check · Drydock Exam · COI Inspection · Internal Structural Exam · MTSA Verification · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6014447
13 November 2015 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5762770
19 February 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5071240
23 December 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5043430
28 October 2014 MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5013793
28 March 2014 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4824685
8 January 2014 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4778727
3 July 2013 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4663240
20 November 2012 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4492994
13 November 2012 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4483670
13 November 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4487740
6 December 2011 Deficiency Check · Plan Review (Other than "T") · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4201592
2 December 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4200447
6 October 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4154831
13 October 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3869314
10 June 2009 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3500548
18 December 2008 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3381721
10 April 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3181134
14 November 2007 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3098125
16 August 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3029768
1 February 2007 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2865667
4 January 2007 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2849920
14 December 2006 Administrative Inspection · Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2840289
22 November 2006 Initial Certification · MTSA Verification · Hull Examination · Internal Structural Exam · Cargo Tank Internal · Construction Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2827111
15 November 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2821369

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 January 2026 Resolved
Remote control for the means of stoppin machinery...fuel oil transfer pumps... must be test at each regular inspection... Fwd starboard cargo pump e-stop did not shut pump down. 46 CFR 61.20-3(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 January 2026
Resolution: E-stop adjusted and lubricated. Consecutively stopped x3 w/ e-stop after adjustment
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 January 2026 Resolved
...all rotating machinery capable of injuring personnel must be provided with adequate covers or guards. No fan guards present on ventilation fans of generator and thermo-fluid heater rooms. 46 CFR 58.01-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2026
Resolved 12 February 2026
Resolution: Received pictures of installed fan guards.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 January 2026 Resolved
At each inspection... and at such other times... the inspector must determine that all fire extinguishing equipment is in suitable condition. Identified the generator room fire extinguisher had been discharged. Replace. 46 CFR 10-18(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 16 January 2026
Resolution: Received confirm of replacement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 December 2024 Resolved
Tests and inspections of fired thermal fluid heater. Vessel was not prepared for thermal fluid heater inspection. Technical report is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 8 January 2025
Resolution: Operator provided Service report for Themal Fluid Heater.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2023 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Electrical junction box under accommodation space on port side is not properly secured and open. Rectify with in 7 days.
Action required: 705 - Other - as specified
Resolved 19 January 2023
Resolution: Electrical junction box properly secured.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 December 2022 Resolved
Semi-portable extinguishers must be fitted with a suitable hose and nozzle, or other practicable means, so that all portions of the space concerned can be protected. Semi Portable extinguisher is located on the aft section of the cargo deck and unable to reach the fwd cargo deck. An additional Semi portable needs to be added to fwd cargo deck, or additional hose needs to be added so hose can reach all portions of the deck (installed in accordance with manufacturer specifications), or current semi-portable extinguisher needs to be placed amidship if hose can be proven to reach all sections of the cargo area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2022 Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. Fire extinguisher was in its designated bracket on the deck unsecured in the galley/office space. Extinguisher needs to be mounted off the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2021 Resolved
The frame or support of each size III, IV, and V fire extinguisher required by table 34.50-10(a) must be welded or otherwise permanently attached to the deck. The semi-portable extinguisher was not attached to the deck or bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 28 October 2021
Resolution: Received photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 October 2021 Resolved
Between sunset and sunrise, the lighting required by 33 CFR 154.570 and 155.790 must be provided during cargo operations. 01 decklight was out above the machinery space on the starboard side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 28 October 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 October 2020 Resolved
Vessel must have high and overfill alarms that activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled. The high level alarm light did not work.
Action required: 10 - Deficiency Rectified
Resolved 21 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020 Resolved
All tank vessels are subject to the regulations contained in subchapter J. Hazardous Zone equipment must be approved as suitable for use in the specific hazardous atmosphere in which it is installed. The forward life ring had a non-intrinsically safe light inside the hazardous zone.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 23 October 2020
Resolution: Operator provided picture of ring life buoy with non-intrinsically safe light relocated outside the hazardous zone.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2020 Resolved
Ring life buoys shall be approved under 160.150 of this part. The forward ring life buoy had deteriorated beckets (grab lines).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 23 October 2020
Resolution: Operator provided picture of ring life buoy with non-intrinsically safe light relocated outside the hazardous zone.
01 - Certificates & Documentation › 013 - Documents › Booklet for bulk cargo loading/unloading/stowage
Issued 8 October 2019 Resolved
Vessel did not have complete procedures meeting the content requirements in 46 CFR 155.750.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2019 Resolved
Aft lifebuoy was found with inadequate retro-reflective tape and deteriorated line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
Construction/Loadline › Structures › End Bulkhead
Issued 30 December 2017 Resolved
Vessel must make proper repiars with USCG oversight. Vessel must submit repair plan to the inspections division.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2017
Resolved 8 January 2018
Resolution: Vessel repair complete. Observed air test. All sat. Def cleared.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 14 October 2016 Resolved
All tank vsls, except unmanned barges, shall have efficient rails on deck. Lifelines were missing on the fwd section of the barge. Lower courses were missing along port side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 24 October 2016
Resolution: Received photos of life lines in place.
Construction/Loadline › Hull › Double Hull
Issued 28 October 2014 Resolved
Issued 15 Worklist Items from ISE to be corrected at next available dry dock on 31OCT16. Ref MISLE Activity 5013793.
Due 31 October 2016
Resolved 3 October 2016
Resolution: Attended vessel in Drydock, cleared all worklist items for credit drydock.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 8 January 2014 Resolved
Provide copy of documentation of satisfactory testing of cargo pump relief valve. 46 CFR 35.35-70(b)
Due 31 March 2014
Resolved 15 April 2014
Resolution: Received documentation of test.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 8 January 2014 Resolved
Demonstrate proper operation of loss of power for cargo tanks liquid overfill protection. 46 CFR 39.2007
Due 31 March 2014
Resolved 7 April 2014
Resolution: Attended vessel and witnessed proper operation.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 January 2014 Resolved
240v panel in crew quarters does not have ground detection after the transformer. Vessel will be required to submit plans to MSC for review.
Due 31 March 2014
Resolved 3 April 2014
Resolution: Verified proper installation of ground detection on panel.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 20 November 2012 Resolved
Vessel recently installed over speed protection on both generator sets. Operator was unable to demonstrate operation of the over speed device.
Action required: 705 - Other - as specified
Due 4 December 2012
Resolved 4 December 2012
Resolution: Received technicians report, over speed on both generators work properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 20 November 2012 Resolved
The yellow high level light on top of the thermal fluid heater house is inoperable. Repair.
Action required: 705 - Other - as specified
Due 4 December 2012
Resolved 4 December 2012
Resolution: Received picture and a receipt of the new bulb along with a statement from the vessel representative [name withheld] that the high level light located on the TFH house is operational.
Construction/Loadline › Structures › Deck Plating
Issued 13 November 2012 Resolved
VESSEL IS AUTHORIZED ONE (01) MOVEMENT TO GORDON'S TERMINAL TO OFFLOAD CURRENT CARGO. WHEN BARGE IS SUFFICIENTLY EMPTY, THE VESSEL MAY PROCEED TO CLEANING FACILITY TO CLEAN CARGO TANKS, THEN SHIPYARD TO REPAIR DAMAGE ON PORT SIDE SHELL / DECK IWO YOKOHAMA FENDER SLED (APPX #4 PORT VOID) PRIOR TO RE-ENTERING CARGO OPERATIONS.
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 November 2012
Resolution: Vessel repaired damage and witnessed by USCG.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 December 2011 Resolved
Vessel is permissively manned and required to have rails at least 39.5 inches high. Vessel is missing rails halfway up the starboard side from aft. Vessel rep stated that the rail gets in the way of the cargo hose connection. Vessel must reinstall rails. 46CFR32.02-10
Action required: 705 - Other - as specified
Due 6 January 2012
Resolved 6 January 2012
Resolution: Vessel provided photographic evidence displaying the installation of handrails up the starboard side.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 June 2009 Resolved
Make proper repairs to outboard hydraulic pump. Pump is to be placed out-of-service until inspected by attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 11 June 2009
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 February 2007 Resolved
The approved VRP for this T/B does not list zone approval for COTP NY. The VRP approval letter dtd 18 Dec 06 did not include COTP Zone NY. The POC at Harley Marine Service contacted the VRP program regarding the add zone COTP NY revisions received on 31 Jan 07. The revision is under review and will be completed within a 3-4 week period. (Reference VRP control #02409, correspondence log.)
Due 1 March 2007
Resolved 6 April 2007
Resolution: Add Zone revion was approved on 04/06/2007. Approval letter with COTP NYC on barge was verrified of 14 Nov 2007.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 4 January 2007 Resolved
Vessel Rep. could not provide proof of Combustible Gas Indicator or calibration equipment onboard vessel.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 5 January 2007
Resolution: Vessel Rep. provided proof of purchase for the Combustible Gas Indicator.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 November 2006 Resolved
Provide proof of cargo pump engine wiring harness and alternator meeting 46 CFR 111.105-31(l) / N.E.C. class 1/division 1 as per USCG D8 (m) policy letter 02-2005 NLT 31 August, 2007.
Action required: 705 - Other - as specified
Due 31 August 2007
Resolved 24 August 2007
Resolution: Using guidance from MSC memorandum Cargo restrictions changed allowing only grade "D" cargos with a flashpoint of 140 degrees and higher, and grade "E" cargos. COI amended to reflect changes

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.