Inspection history · 44
6 January 2026
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8290163
11 December 2024
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8046031
28 June 2024
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7916356
25 October 2023
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7810996
9 May 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7684682
8 December 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7606256
12 October 2021
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7331242
21 June 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7232094
21 October 2020
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7081457
2 September 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7066755
8 October 2019
Periodic Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6830383
20 November 2018
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6584001
30 May 2018
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6423408
19 April 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394531
9 April 2018
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6388891
5 April 2018
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6386001
30 December 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6330553
29 December 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6330786
26 October 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6294852
3 October 2016
Deficiency Check · Drydock Exam · COI Inspection · Internal Structural Exam · MTSA Verification · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6014447
13 November 2015
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5762770
19 February 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5071240
23 December 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5043430
28 October 2014
MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5013793
28 March 2014
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4824685
8 January 2014
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4778727
3 July 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4663240
20 November 2012
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4492994
13 November 2012
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4483670
13 November 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4487740
6 December 2011
Deficiency Check · Plan Review (Other than "T") · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4201592
2 December 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4200447
6 October 2011
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4154831
13 October 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3869314
10 June 2009
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3500548
18 December 2008
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3381721
10 April 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3181134
14 November 2007
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3098125
16 August 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3029768
1 February 2007
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2865667
4 January 2007
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2849920
14 December 2006
Administrative Inspection · Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2840289
22 November 2006
Initial Certification · MTSA Verification · Hull Examination · Internal Structural Exam · Cargo Tank Internal · Construction Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2827111
15 November 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2821369
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 January 2026
Resolved
Remote control for the means of stoppin machinery...fuel oil transfer pumps... must be test at each regular inspection...
Fwd starboard cargo pump e-stop did not shut pump down.
46 CFR 61.20-3(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 January 2026
Resolution: E-stop adjusted and lubricated. Consecutively stopped x3 w/ e-stop after adjustment
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 January 2026
Resolved
...all rotating machinery capable of injuring personnel must be provided with adequate covers or guards.
No fan guards present on ventilation fans of generator and thermo-fluid heater rooms.
46 CFR 58.01-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2026
Resolved 12 February 2026
Resolution: Received pictures of installed fan guards.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 January 2026
Resolved
At each inspection... and at such other times... the inspector must determine that all fire extinguishing equipment is in suitable condition.
Identified the generator room fire extinguisher had been discharged. Replace.
46 CFR 10-18(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2026
Resolved 16 January 2026
Resolution: Received confirm of replacement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 December 2024
Resolved
Tests and inspections of fired thermal fluid heater. Vessel was not prepared for thermal fluid heater inspection. Technical report is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 8 January 2025
Resolution: Operator provided Service report for Themal Fluid Heater.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2023
Resolved
Electric installations on vessels must ensure:
Protection of passengers, crew, other persons, and the
vessel from electrical hazards. Electrical junction box
under accommodation space on port side is not properly
secured and open. Rectify with in 7 days.
Action required: 705 - Other - as specified
Resolved 19 January 2023
Resolution: Electrical junction box properly secured.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 December 2022
Resolved
Semi-portable extinguishers must be fitted with a
suitable hose and nozzle, or other practicable means, so
that all portions of the space concerned can be
protected. Semi Portable extinguisher is located on the
aft section of the cargo deck and unable to reach the
fwd cargo deck. An additional Semi portable needs to be
added to fwd cargo deck, or additional hose needs to be
added so hose can reach all portions of the deck
(installed in accordance with manufacturer
specifications), or current semi-portable extinguisher
needs to be placed amidship if hose can be proven to
reach all sections of the cargo area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2022
Resolved
The owner, master, or person-in-charge of a tank vessel
must ensure that portable and semi-portable
extinguishers are inspected and maintained in accordance
with NFPA 10. Fire extinguisher was in its designated
bracket on the deck unsecured in the galley/office
space. Extinguisher needs to be mounted off the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2021
Resolved
The frame or support of each size III, IV, and V fire extinguisher required by table 34.50-10(a) must be welded or otherwise permanently attached to the deck.
The semi-portable extinguisher was not attached to the deck or bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 28 October 2021
Resolution: Received photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 October 2021
Resolved
Between sunset and sunrise, the lighting required by 33 CFR 154.570 and 155.790 must be provided during cargo operations.
01 decklight was out above the machinery space on the starboard side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 28 October 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 October 2020
Resolved
Vessel must have high and overfill alarms that activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled. The high level alarm light did not work.
Action required: 10 - Deficiency Rectified
Resolved 21 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020
Resolved
All tank vessels are subject to the regulations contained in subchapter J.
Hazardous Zone equipment must be approved as suitable for use in the specific hazardous atmosphere in which it is installed.
The forward life ring had a non-intrinsically safe light inside the hazardous zone.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 23 October 2020
Resolution: Operator provided picture of ring life buoy with non-intrinsically safe light relocated outside the hazardous zone.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2020
Resolved
Ring life buoys shall be approved under 160.150 of this part. The forward ring life buoy had deteriorated beckets (grab lines).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 23 October 2020
Resolution: Operator provided picture of ring life buoy with non-intrinsically safe light relocated outside the hazardous zone.
01 - Certificates & Documentation › 013 - Documents › Booklet for bulk cargo loading/unloading/stowage
Issued 8 October 2019
Resolved
Vessel did not have complete procedures meeting the content requirements in 46 CFR 155.750.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2019
Resolved
Aft lifebuoy was found with inadequate retro-reflective tape and deteriorated line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2019
Construction/Loadline › Structures › End Bulkhead
Issued 30 December 2017
Resolved
Vessel must make proper repiars with USCG oversight. Vessel must submit repair plan to the inspections division.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2017
Resolved 8 January 2018
Resolution: Vessel repair complete. Observed air test. All sat. Def cleared.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 14 October 2016
Resolved
All tank vsls, except unmanned barges, shall have efficient rails on deck. Lifelines were missing on the fwd section of the barge. Lower courses were missing along port side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 24 October 2016
Resolution: Received photos of life lines in place.
Construction/Loadline › Hull › Double Hull
Issued 28 October 2014
Resolved
Issued 15 Worklist Items from ISE to be corrected at next available dry dock on 31OCT16. Ref MISLE Activity 5013793.
Due 31 October 2016
Resolved 3 October 2016
Resolution: Attended vessel in Drydock, cleared all worklist items for credit drydock.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 8 January 2014
Resolved
Provide copy of documentation of satisfactory testing of cargo pump relief valve. 46 CFR 35.35-70(b)
Due 31 March 2014
Resolved 15 April 2014
Resolution: Received documentation of test.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 8 January 2014
Resolved
Demonstrate proper operation of loss of power for cargo tanks liquid overfill protection. 46 CFR 39.2007
Due 31 March 2014
Resolved 7 April 2014
Resolution: Attended vessel and witnessed proper operation.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 January 2014
Resolved
240v panel in crew quarters does not have ground detection after the transformer. Vessel will be required to submit plans to MSC for review.
Due 31 March 2014
Resolved 3 April 2014
Resolution: Verified proper installation of ground detection on panel.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 20 November 2012
Resolved
Vessel recently installed over speed protection on both generator sets. Operator was unable to demonstrate operation of the over speed device.
Action required: 705 - Other - as specified
Due 4 December 2012
Resolved 4 December 2012
Resolution: Received technicians report, over speed on both generators work properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 20 November 2012
Resolved
The yellow high level light on top of the thermal fluid heater house is inoperable. Repair.
Action required: 705 - Other - as specified
Due 4 December 2012
Resolved 4 December 2012
Resolution: Received picture and a receipt of the new bulb along with a statement from the vessel representative [name withheld] that the high level light located on the TFH house is operational.
Construction/Loadline › Structures › Deck Plating
Issued 13 November 2012
Resolved
VESSEL IS AUTHORIZED ONE (01) MOVEMENT TO GORDON'S TERMINAL TO OFFLOAD CURRENT CARGO. WHEN BARGE IS SUFFICIENTLY EMPTY, THE VESSEL MAY PROCEED TO CLEANING FACILITY TO CLEAN CARGO TANKS, THEN SHIPYARD TO REPAIR DAMAGE ON PORT SIDE SHELL / DECK IWO YOKOHAMA FENDER SLED (APPX #4 PORT VOID) PRIOR TO RE-ENTERING CARGO OPERATIONS.
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 November 2012
Resolution: Vessel repaired damage and witnessed by USCG.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 December 2011
Resolved
Vessel is permissively manned and required to have rails at least 39.5 inches high. Vessel is missing rails halfway up the starboard side from aft. Vessel rep stated that the rail gets in the way of the cargo hose connection. Vessel must reinstall rails. 46CFR32.02-10
Action required: 705 - Other - as specified
Due 6 January 2012
Resolved 6 January 2012
Resolution: Vessel provided photographic evidence displaying the installation of handrails up the starboard side.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 June 2009
Resolved
Make proper repairs to outboard hydraulic pump. Pump is to be placed out-of-service until inspected by attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 11 June 2009
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 February 2007
Resolved
The approved VRP for this T/B does not list zone approval for COTP NY. The VRP approval letter dtd 18 Dec 06 did not include COTP Zone NY. The POC at Harley Marine Service contacted the VRP program regarding the add zone COTP NY revisions received on 31 Jan 07. The revision is under review and will be completed within a 3-4 week period. (Reference VRP control #02409, correspondence log.)
Due 1 March 2007
Resolved 6 April 2007
Resolution: Add Zone revion was approved on 04/06/2007. Approval letter with COTP NYC on barge was verrified of 14 Nov 2007.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 4 January 2007
Resolved
Vessel Rep. could not provide proof of Combustible Gas Indicator or calibration equipment onboard vessel.
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 5 January 2007
Resolution: Vessel Rep. provided proof of purchase for the Combustible Gas Indicator.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 November 2006
Resolved
Provide proof of cargo pump engine wiring harness and alternator meeting 46 CFR 111.105-31(l) / N.E.C. class 1/division 1 as per USCG D8 (m) policy letter 02-2005 NLT 31 August, 2007.
Action required: 705 - Other - as specified
Due 31 August 2007
Resolved 24 August 2007
Resolution: Using guidance from MSC memorandum Cargo restrictions changed allowing only grade "D" cargos with a flashpoint of 140 degrees and higher, and grade "E" cargos. COI amended to reflect changes