MAG 573 is a 2007 tank barge. The Coast Guard has recorded 28 inspections since 2007, most recently in May 2026, along with 6 deficiencies and 2 casualty investigations between 2013 and 2016.
Records from 2007 to 2026. Most recent: inspection, 28 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)154.0 ft × 42.0 ft × 10.0 ft
Registered tonnagegross 543 / net 543
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC & C MARINE · BELLE CHASSE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it543 - Simplified, Gross Ton 543 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
Annual Inspection. Your Vessel must undergo an annual inspection within 3 months before or after each anniversary date.
Vessel missed required annual exam due 3 months before or after 26MAY2025.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 June 2026
Resolution: Conducted COI inspection and issued new COI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 June 2024Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. Observed annual inspections on both portable fire extinguishers has not been completed. Service fire extinguishers prior to conducting cargo operations. 46 CFR 31.10-18(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2024
Resolution: Received technician's report attesting to servicing of fire extinguishers.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 20 June 2024Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. Observed flange was missing permanent stud on VCS line. Install stud prior to conducting cargo operations. 46 CFR 39.2001(j).
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 July 2024
Resolution: Received Photographic evidence of installation of permanent stud.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 20 June 2024Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be (1) painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter (0.33 foot) and the width of the middle yellow band must be 0.8 meter (2.64 feet); and (2) Labeled with the word “VAPOR” painted in black letters at least 50.8 millimeters (2 inches) high. Inspectors observed entire VCS line painted in yellow. Repaint vapor line to match requirements above. 46 CFR 39.2001(h).
Action required: 705 - Other - as specified
Resolved 24 July 2024
Resolution: Received photographic evidence of properly painted vapor line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 June 2024Resolved
At each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation.
As incorporated by ABS 4-2-1-7.17 Required monitoring for engine’s fuel oil, lubricating oil, cooling water, starting air and exhaust gas systems are provided in the system requirements. Inspectors were unable to read electronic gauge to identify engine RPM, cooling water PSI or oil temperature. Install new engine monitoring display prior to conducting cargo operations. 46 CFR 61.20-3(a).
Action required: 705 - Other - as specified
Resolved 24 July 2024
Resolution: Received photgraphic evidence on new properly installed guage cluster.
Wiring Harness on Prime Mover is not intrinsically safe, explosion proof, or purged and pressurized for a Class I Div I area. Ref D8(dp) Policy Letter 02-2007 CH1. Barge is allowed to operate until Aug 08 per policy ltr.
Due 30 June 2011
Resolved 1 March 2011
Resolution: D8 issued letter to Settoon Towing, LLC dated 05NOV10 stating the Class I Div I compliance date has been postponed. This vessel must comply with the Class I Div I requirement by the first dry dock after 01NOV2011, but no later than 01NOV2015.
7 March 2016Routine · role: Involved in a Marine Casualty · activity 5830408
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SMI 573 (2013–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.