None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 December 2025
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2007–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9369409
WDE3893
870711
Flag
UNITED STATES
Maury page id
psix-870711

Documentation record

Registered dimensions (L × B × D)129.6 ft × 42.0 ft × 21.9 ft
Registered tonnagegross 465 / net 316
ITC dimensions (L × B × D)129.6 ft × 42.0 ft × 21.9 ft
ITC tonnagegross 1,052 / net 315
BuilderVT HALTER MARINE · ESCATAWPA, MS, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1052 - Convention (Subpart B), Gross Ton
465 - Regulatory (Subpart C or D), Gross Ton
315 - Convention (Subpart B), Net Ton
316 - Regulatory (Subpart C or D), Net Ton
820 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 74 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 74

5 December 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8278301
30 October 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8260967
14 February 2025 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8078031
13 February 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8079016
4 February 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8074650
3 February 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8080671
4 November 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8029526
12 December 2023 TPO Audit
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7909472
16 September 2023 ACP COI Oversight · Re-Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7678997
24 October 2022 ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7547313
21 September 2022 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7564359
4 June 2022 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7468143
15 May 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7451014
3 November 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7288704
25 August 2021 MTSA/ISPS Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7296684
19 October 2020 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7076958
10 September 2020 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7073800
17 October 2019 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6836316
28 June 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6741950
12 March 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6641310
5 March 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637367
28 June 2018 Administrative Inspection · Re-Inspection · ACP COI Oversight
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6458571
9 May 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6409840
19 October 2017 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6291686
18 November 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6045470
2 November 2016 MTSA/ISPS Verification · Administrative Inspection · ACP Periodic Oversight · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6033766
27 August 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5984421
27 August 2016 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5986602
21 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5982335
13 January 2016 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5800934
1 October 2015 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5887520
2 September 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5232965
2 September 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5233304
12 August 2015 MTSA/ISPS Verification · Drydock Exam · ACP Handover Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5197810
11 July 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5180434
10 July 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5180086
26 December 2014 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5048699
22 October 2014 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5004719
21 June 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4930506
16 June 2014 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4907008
2 July 2013 DAPI Audit · MTSA/ISPS Verification · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4640124
26 February 2013 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4539304
3 December 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4494930
19 October 2012 Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4468004
1 August 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4398199
1 August 2012 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4399888
1 August 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4400012
13 March 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4268500
5 December 2011 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4201574
24 October 2011 Administrative Inspection · MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4174877
30 June 2011 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4063127
24 May 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4020696
24 May 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4033020
1 March 2011 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3961018
18 January 2011 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3928191
23 November 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3900166
26 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3878723
2 August 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3828161
18 June 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3772500
21 January 2010 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3667571
18 August 2009 Annual Inspection · DAPI Audit · Administrative Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3568426
1 July 2009 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3520282
9 April 2009 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3449327
20 February 2009 In-Service Inspection · Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3421369
20 February 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3426274
22 December 2008 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3383668
2 November 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365990
29 August 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3456581
28 July 2008 DAPI Audit · MTSA Verification · Plan Review (Other than "T") · Construction Oversight · Initial Certification · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3282507
30 June 2008 Deadweight Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3254511
26 June 2008 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3248668
16 May 2008 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3208109
12 May 2008 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3204556
18 December 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3117651

Deficiency record · 21

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 February 2025 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessel reported air accumulation in the jacket water system on the starboard main engine due to high pressure in the charge air system. Engine rpm has to be reduced to avoid the issue. 74 SOLAS (2009), Ch. II-I, Reg 31.1
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2025
Resolved 9 February 2025
Resolution: Received satisfactory Preliminary Report from ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024 Resolved
Piping systems for ships and barges must be designed, constructed, and inspected in accordance with ASME B31.1 MI found significant corrosion on suction side of fire pump sea chest spool piece. Vessel to replace corroded section to the satisfaction of class.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 October 2022 Resolved
A Class Division Fire doors in the main vertical zone bulkheads, shall be self-closing. MI observed the “Up Wheel House” door did not latch when closed. 74SOLAS (04) II-2/9.4.1.1.4
Action required: 10 - Deficiency Rectified
Due 24 October 2022
Resolved 24 October 2022
Resolution: Readjusted Door to satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 October 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI observed the secondary Mast Light extinguished. 74 SOLAS I/11 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 2 November 2022
Resolution: Deficiency accepted by class and issued Finding Number 464.0.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 24 October 2022 Resolved
The angular position of the rudder shall: if the main steering gear is power-operated, be indicated on the navigation bridge. MI observed differences between the bridge rudder angle indicator and the steering gear room of 7 degrees. 74SOLAS (04) II-1/29.11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 2 November 2022
Resolution: Deficiency accepted by class and issued Finding Number 465.0.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2022 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Marine Inspector identified starboard main diesel engine shaft pouring water through the shaft seal in the engine room. 74 SOLAS (04) II-1/26-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2022
Resolved 2 November 2022
Resolution: Deficiency accepted by class and issued Finding Number 466.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2022 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI-1/1, or with applicable national standards of the Administration which provide an equivalent level of safety. Marine Inspector identified electrical cabling that had been cut at three junction boxes including one junction box with an open cable penetration located in the starboard side lower purifier room. 74 SOLAS (04) II-1/3-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2022
Resolved 2 November 2022
Resolution: Deficiency accepted by class and issued Finding Number 467.0.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 October 2022 Resolved
The means for securing and maintaining weather tightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions… During inspection of the aft steering compartment hatch and port side CO2 compartment watertight door the Marine Inspector identified potential gaps in the sealing surfaces. Crew conducted chalk test identifying areas that were not sealing. ICLL (66) 16(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2022
Resolved 2 November 2022
Resolution: Deficiency accepted by class and issued Finding Number 468.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2022 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI-1/1, or with applicable national standards of the Administration which provide an equivalent level of safety. Marine Inspector identified electrical cabling mounting brackets and hangers located in the aft steering compartment severely corroded and missing. 74 SOLAS (04) II-1/3-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2022
Resolved 2 November 2022
Resolution: Deficiency accepted by class and issued Finding Number 469.0.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2022 Resolved
Starboard Main Diesel Engine turbo failed while casting lines from pier. Repair and provide class report prior to departure. 70SOLAS20 I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Right and Left bank turbos replaced with OEM parts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2022 Resolved
Starboard Main Diesel Engine shut down while underway. Repair and provide class report prior to departure. 70SOLAS20 I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2022
Resolution: Satisfactory Tech and class report received.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 August 2018 Resolved
The onboard fixed fire monitor utilized for fire fighting onboard the assigned tank barge is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2018
Resolved 13 March 2019
Resolution: SECTOR NOLA CLEARED DEF - SEE DEF CLEARANCE DOCUMENT IN MISELE
Electrical › Electric Generation Source (service) › Generator
Issued 21 August 2016 Resolved
Generator shut down while underway. Repair/replace generator and provide class report to MI prior to departure from SECNOLA AOR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2016
Resolved 22 August 2016
Resolution: Received class report attesting to replacement and proper testing of new generator.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 2 September 2015 Resolved
Vessel reported continual stbd engine shutdown. Worked with engine manufacturer's rep to discover bad relay module. Replaced relay module and conducted satisfactory tests and operations. Awaiting Master's statement attesting to proper replacement and operation of stbd engine.
Due 2 September 2015
Resolved 2 September 2015
Resolution: Replaced relay module in stbd engine. All tests sat. Received master''s statement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 October 2014 Resolved
Provide Technician's report attesting to proper repair, satisfactory testing, and operation of engineroom CO2 system.
Due 29 October 2014
Resolved 29 October 2014
Resolution: Garba Electric tested with the Chief Engineer several times and the CO2 system operated consistently when tripped from both pressure switches. The engineroom ventilation was secured by either pressure switch tripping along with fuel valves and equipment
Fire Fighting › Grease Extraction Hood › General
Issued 22 October 2014 Resolved
Provide technician's report attesting to satisfactory operation of galley wet system.
Condition: Improper Installation
Due 29 October 2014
Resolved 29 October 2014
Resolution: City Fire visited the vessel in Tampa and certified the Galley range hood foam system and verified operation of the CO2 system for the engineroom. All systems have passed the annual inspection and received certification.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 26 February 2013 Resolved
Port Generator is inoperable due to a damaged head. Make repairs to the generator to the satisfaction of the attending classification society and Coast Guard. 46 CFR 111.10-3
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2013
Resolved 27 February 2013
Resolution: Power pack changed out and generator carried load.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 26 February 2013 Resolved
Raw water cooling line failed closed during operational test of port generator. Repair/replace to satisfaction of the attending class society and the Coast Guard. 46 CFR 111.10-3
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2013
Resolved 27 February 2013
Resolution: Valve replaced with new-in-kind.
Electrical › Electric Generation Source (service) › Generator
Issued 1 August 2012 Resolved
Repair and prove proper operation of ship's service generator. All repairs are to be completed prior to departing Port Everglades, Fl and to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2012
Resolution: Witnessed satisfactory operational testing of newly installed no.1 generator set in single and parallel modes. Witnessed low oil pressure, high jacket water temp and over-speed trip shut-downs required by attending ABS surveyor.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (air motor)
Issued 5 December 2011 Resolved
Vessels STBD MDE would not start. Crew found chaffed air return line from bendix on starter. Temp repair made by fab new air line frm copper tubing & threaded fittings. Make perm repairs with original as designed flex air lines. 46 CFR 58.05
Action required: 705 - Other - as specified
Due 13 December 2011
Resolved 7 December 2011
Resolution: New in kind airline installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 20 February 2009 Resolved
While conducting pre-departure checks on the engines (blow downs), the port engine experienced cooling water spraying from the cylinder A1; unknown cause. Vessel will replace cylinder heads as necessary and test port engines prior to departure from port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2009
Resolution: Wartsila tech reps and vessel engineers replaced (02) cylinders on the port engine: A1 & B1. Satisfactory tests were conducted and no discrepancies were noted.

Ownership record