MAURY USCG vessel records
← All vessels

KALEB DEAN

Built
1966
Last inspected
5 December 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 December 2024
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1986–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI4052
Flag
UNITED STATES
Maury page id
psix-89339

Documentation record

Registered dimensions (L × B × D)50.1 ft × 22.0 ft × 6.9 ft
Registered tonnagegross 69 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT, INC. · JEFFERSONVILLE, IN, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portOLD SHAWNEETOWN, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 4 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Net Ton
69 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 13 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

Inspection history · 24

5 December 2024 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8043518
28 August 2024 TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7995168
10 May 2024 Deficiency Check · TPO Audit · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7910179
27 February 2024 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7870818
11 September 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7789282
28 February 2023 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7643066
14 April 2022 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7412020
27 September 2021 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7321362
7 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7149456
16 June 2020 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6955170
26 April 2019 Administrative Inspection · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6670848
28 January 2018 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6347678
18 July 2017 Industry Initiated Exam · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6211949
5 November 2014 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5019685
21 May 2014 Deficiency Check · Administration · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4875852
26 April 2011 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4003292
22 December 2009 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3658180
24 November 2009 Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3639558
18 March 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3168433
19 November 2002 Uninspected Towing Vessel
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1708210
5 March 2002 Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1495577
15 March 2001 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 288222
21 April 2000 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 277141
26 March 1986 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 307779

Deficiency record · 11

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 July 2024 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS). Anchor light not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 29 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical panel missing blanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 29 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 July 2024 Resolved
The total relieving capacity of such relied valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10%. MAWP on air is 200 relief valve is 225.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 29 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 April 2022 Resolved
Firs Aid kit had expired medicine. 46CFR140.435
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 19 April 2023
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 April 2022 Resolved
Port MDE low oil alarm was not working properly, no audible alarm. 46CFR143.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 18 September 2023
Resolution: Ground was identified and repairs were made alarms tested SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 14 April 2022 Resolved
Vessel engine room was not clean, trash and oil filter in the bilge, water inside battery box. 46CFR140.205
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 19 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2021 Resolved
4 type 1 PFDs had flashlights that were not operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 26 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2021 Resolved
The stenciling on the ring buoy on the port side bridge wing was faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 26 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 April 2021 Resolved
Vessel did not have flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 27 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2021 Resolved
Emergency fuel shutoffs for the port MDE and both SSDG did not fully close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 26 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2021 Resolved
The fire hose for the portable fire pump had multiple leaks in it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 26 April 2021

Ownership record