MAURY USCG vessel records Sign in
← All vessels

EVAN H

EVAN H is a 1997 towing vessel. The Coast Guard has recorded 31 inspections since 1998, most recently in August 2023, along with 19 deficiencies and 6 casualty investigations between 2008 and 2017.

Records from 1998 to 2023. Most recent: inspection, 29 August 2023.

Built
1997
Last inspected
29 August 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI4051
449552
Flag
UNITED STATES
368227470
Maury page id
psix-449552

Inspections, by type

…with no type recorded10
Years with a record 17 calendar years (1998–2023)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 61 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS INC · UTICA, IN, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHAVANA, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Simplified, Net Ton
61 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM6699MMSI 368227470 · active · compulsorily equipped · granted 13 November 2021, expires 13 November 2031
WDI4051MMSI 367694640 · cancelled · compulsorily equipped · granted 1 October 2015, cancelled 26 October 2021
WCX3003MMSI not assigned · expired · compulsorily equipped · granted 17 March 1997, cancelled 20 May 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 21

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MARY ELLEN JONES Towing Vessel · MISLE 88215 · 30 November 2017 · activity 6320482ING 5630 Freight Barge · MISLE 204978 · 22 December 2014 · activity 5045081KALEB DEAN Towing Vessel · MISLE 89339 · 26 April 2011 · activity 4003292MARGARET ANN Towing Vessel · MISLE 121803 · 26 April 2011 · activity 4003292LEO G. LUTGRING Towing Vessel · MISLE 160323 · 26 April 2011 · activity 4003292KILLIAN L. HUGER Towing Vessel · MISLE 167289 · 26 April 2011 · activity 4003292KIRBY 28000B Tank Barge · MISLE 41448 · 23 June 2008 · activity 3245685CITY OF LOUISVILLE Towing Vessel · MISLE 80114 · 23 June 2008 · activity 3245685MARTY B Towing Vessel · MISLE 205507 · 23 June 2008 · activity 3245685KIRBY 28078 Tank Barge · MISLE 810448 · 23 June 2008 · activity 3245685SD 13 Tank Barge · MISLE 45118 · 9 April 2008 · activity 3181318SD 15 Tank Barge · MISLE 45726 · 9 April 2008 · activity 3181318CAPT. KENNY CADY Towing Vessel · MISLE 75452 · 9 April 2008 · activity 3181318CHARLES SOUTHERN Towing Vessel · MISLE 95164 · 9 April 2008 · activity 3181318ACL 00582 Freight Barge · MISLE 29562 · 18 March 2008 · activity 3168433ACL 01540 Freight Barge · MISLE 29632 · 18 March 2008 · activity 3168433AIDEN WILLIAM Towing Vessel · MISLE 70086 · 18 March 2008 · activity 3168433KALEB DEAN Towing Vessel · MISLE 89339 · 18 March 2008 · activity 3168433HAL J PANNELL Towing Vessel · MISLE 206401 · 18 March 2008 · activity 3168433ACL 96033 Freight Barge · MISLE 441929 · 18 March 2008 · activity 3168433LYDIA MARIE Towing Vessel · MISLE 70767 · 9 February 1998 · activity 62589IN936429 Freight Barge · MISLE 387620 · 9 February 1998 · activity 62589

Inspection history · 31

29 August 2023 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7770445
2 December 2022 Deficiency Check · TPO Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7608284
1 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7548525
7 June 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7471082
10 May 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7447540
10 February 2022 Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7394027
29 November 2021 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7358428
24 November 2021 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7356953
22 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7292065
29 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7059060
22 July 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6758405
20 December 2018 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6600621
16 July 2018 Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6484396
30 November 2017 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6320482
18 July 2017 Industry Initiated Exam · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6211955
6 October 2016 Administrative Inspection · DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6033844
22 December 2014 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5045081
6 March 2014 Deficiency Check · Industry Initiated Exam · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4817304
24 March 2013 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4565392
31 January 2013 DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4527623
26 April 2011 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4003292
4 November 2010 DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3885442
15 June 2009 Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3500351
9 June 2009 DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3525586
23 June 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3245685
9 April 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3181318
18 March 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3168433
9 December 2002 Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1719617
26 February 2001 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 287668
9 February 1998 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 62589
6 January 1998 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 411554

Deficiency record · 19

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2021 Resolved
No evidence that the FDS was tested annually. Provide evidence that the FDS was tested in the past 12 months.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 27 September 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 September 2021 Resolved
3 first aid kits found on the 2nd deck had expired items within. Removed expired items and have at least 1 full first aid kit onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 27 September 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2021 Resolved
Monthly inspections were not being conducted on the portable and semi portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 27 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 September 2020 Resolved
Each towing vessel must have either a self priming power driven fixed or portable fire pump. During test of fire pump crew member had to open drain petcock on the pump located in engine room while turning the pump on and off to build suction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 20 October 2020
Resolution: Vessel acquired a portable fire pump meeting the regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2020 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line that supplies fuel directly to propulsion engines or generator prime movers, The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Both valves were located near the center of the engine room. Rectify NLT next scheduled drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 10 May 2022
Resolution: Reach rods added to existing tank valves.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 22 July 2019 Resolved
The officer in charge of a nav. watch must conduct a navigation assessment for intended route and record in the log; Master is conducting assessment but not properly recording items IAW 140.635. Provide proof of proper log keeping.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2019
Resolved 26 August 2019
Resolution: Master provided proof of updated logging procedures to satisfy requirement.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 22 July 2019 Resolved
The Master of a Towing Vessel must ensure that each crewmember participates in a fire drill at least once each month. Master was conducting fire drills monthly but not always on each vessel. MI educated crew on requirements and witnessed satisfactory fire drill.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 August 2019
Resolved 15 August 2019
Resolution: .
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2018 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation; Vessel's port main engine was observed leaking coolant at water pump. Repair or replace water pump and/or gasket to ensure system integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2018
Resolution: Crew replaced water pump on Port Main engine. No leaks observed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 July 2018 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated; properly insulate exhaust manifolds on both generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: Crew installed lagging on all required surfaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2018 Resolved
The following systems must be equipped with gauges at the machinery location; Auxiliary generator engine RPM. Install tachometers on both generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: Crew installed tachs on both generators local control panels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2018 Resolved
Vessel is not equipped with alarm arrangements IAW Sub M. Install alarms IAW 46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: MI witnessed proper operation of all required alarms at operating station. Low L/o pressure and high h2o temp on both mains and both gens.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2018 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 September 2018
Resolution: Crew installed approved waterlights on bridgewing ring buoys.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 16 July 2018 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Vessel's First Aid kit had several expired items
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: Crew installed new first-aid kit
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 July 2018 Resolved
MI Noted excessive play on port inboard flanking rudder bushing; make repairs to remove excessive play from rudder post.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2018
Resolved 20 December 2018
Resolution: Received Objective evidence of repair
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 October 2016 Resolved
A number of employees were tested with Non-Dot tests. All new employees who were not given a DOT pre-employment test shall be re-tested using a DOT pre-employment test IAW with 46 CFR 16.210, when completing the Federal Custody Control Form the other block should be checked with a note stating the original test was not a DOT test.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 30 November 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 31 January 2013 Resolved
General manager of Shawneetown Harbor Service lacked proof of required supervisor EAP training.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2013
Resolved 14 February 2013
Resolution: Item cleared
Documentation
Issued 26 February 2001 Resolved
NO VESSEL LOG OF TESTS AND INSPECTIONS. 33 CFR 164.78 (B)
Condition: Unknown
Due 27 March 2001
Resolved 9 December 2002
Resolution: Vessel has Log onboard. No further action required.
Navigation
Issued 26 February 2001 Resolved
MISSING COMPASS OR SWING METER 33 CFR 164.72 (A) (4)
Condition: Unknown
Due 27 March 2001
Resolved 9 December 2002
Resolution: Vessel now has an installed magnetic compass. No further action required.
Navigation
Issued 6 January 1998 Resolved
CG LIGHT LIST AND NOTICE TO MARINERS WERE NOT ON THE VESSEL.
Condition: Unknown
Due 20 January 1998
Resolved 9 December 2002
Resolution: Current CG Light list onboard vessel. No further action required.

Casualty record · 6

18 March 2008Routine · role: Sighted in Area · activity 3168433
9 April 2008Routine · role: Sighted in Area · activity 3181318
23 June 2008Routine · role: Transiting Vicinity of Primary Subject · at J.T. MYERS · activity 3245685
26 April 2011Significant Marine Casualty · role: Sighted in Area · serious marine incident, as classified · at SHAWNEETOWN BRIDGE · activity 4003292
24 March 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4565392
30 November 2017Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 6320482
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LINDA LOU (2008–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.