Documentation record
Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 61 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS INC · UTICA, IN, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHAVANA, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 4 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Simplified, Net Ton
61 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
29 August 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7770445
2 December 2022
Deficiency Check · TPO Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7608284
1 September 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7548525
7 June 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7471082
10 May 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7447540
10 February 2022
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7394027
29 November 2021
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7358428
24 November 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7356953
22 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7292065
29 September 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7059060
22 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6758405
20 December 2018
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6600621
16 July 2018
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6484396
30 November 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6320482
18 July 2017
Industry Initiated Exam · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6211955
6 October 2016
Administrative Inspection · DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6033844
22 December 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5045081
6 March 2014
Deficiency Check · Administration · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4817304
24 March 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4565392
31 January 2013
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4527623
26 April 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4003292
4 November 2010
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3885442
15 June 2009
Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3500351
9 June 2009
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3525586
23 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3245685
9 April 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3181318
18 March 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3168433
9 December 2002
Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1719617
26 February 2001
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 287668
9 February 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 62589
6 January 1998
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 411554
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2021
Resolved
No evidence that the FDS was tested annually. Provide evidence that the FDS was tested in the past 12 months.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 27 September 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 September 2021
Resolved
3 first aid kits found on the 2nd deck had expired items within. Removed expired items and have at least 1 full first aid kit onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 27 September 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2021
Resolved
Monthly inspections were not being conducted on the portable and semi portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 27 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 September 2020
Resolved
Each towing vessel must have either a self priming power driven fixed or portable fire pump. During test of fire pump crew member had to open drain petcock on the pump located in engine room while turning the pump on and off to build suction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 20 October 2020
Resolution: Vessel acquired a portable fire pump meeting the regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2020
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line that supplies fuel directly to propulsion engines or generator prime movers, The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Both valves were located near the center of the engine room. Rectify NLT next scheduled drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 10 May 2022
Resolution: Reach rods added to existing tank valves.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 22 July 2019
Resolved
The officer in charge of a nav. watch must conduct a navigation assessment for intended route and record in the log; Master is conducting assessment but not properly recording items IAW 140.635. Provide proof of proper log keeping.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2019
Resolved 26 August 2019
Resolution: Master provided proof of updated logging procedures to satisfy requirement.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 22 July 2019
Resolved
The Master of a Towing Vessel must ensure that each crewmember participates in a fire drill at least once each month. Master was conducting fire drills monthly but not always on each vessel. MI educated crew on requirements and witnessed satisfactory fire drill.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 August 2019
Resolved 15 August 2019
Resolution: .
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2018
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation;
Vessel's port main engine was observed leaking coolant at water pump. Repair or replace water pump and/or gasket to ensure system integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2018
Resolution: Crew replaced water pump on Port Main engine. No leaks observed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 July 2018
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated; properly insulate exhaust manifolds on both generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: Crew installed lagging on all required surfaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2018
Resolved
The following systems must be equipped with gauges at the machinery location; Auxiliary generator engine RPM. Install tachometers on both generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: Crew installed tachs on both generators local control panels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2018
Resolved
Vessel is not equipped with alarm arrangements IAW Sub M. Install alarms IAW 46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: MI witnessed proper operation of all required alarms at operating station. Low L/o pressure and high h2o temp on both mains and both gens.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2018
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 September 2018
Resolution: Crew installed approved waterlights on bridgewing ring buoys.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 16 July 2018
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Vessel's First Aid kit had several expired items
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: Crew installed new first-aid kit
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 July 2018
Resolved
MI Noted excessive play on port inboard flanking rudder bushing; make repairs to remove excessive play from rudder post.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2018
Resolved 20 December 2018
Resolution: Received Objective evidence of repair
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 October 2016
Resolved
A number of employees were tested with Non-Dot tests. All new employees who were not given a DOT pre-employment test shall be re-tested using a DOT pre-employment test IAW with 46 CFR 16.210, when completing the Federal Custody Control Form the other block should be checked with a note stating the original test was not a DOT test.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 30 November 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 31 January 2013
Resolved
General manager of Shawneetown Harbor Service lacked proof of required supervisor EAP training.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2013
Resolved 14 February 2013
Resolution: Item cleared
Documentation
Issued 26 February 2001
Resolved
NO VESSEL LOG OF TESTS AND INSPECTIONS. 33 CFR 164.78 (B)
Condition: Unknown
Due 27 March 2001
Resolved 9 December 2002
Resolution: Vessel has Log onboard. No further action required.
Navigation
Issued 26 February 2001
Resolved
MISSING COMPASS OR SWING METER 33 CFR 164.72 (A) (4)
Condition: Unknown
Due 27 March 2001
Resolved 9 December 2002
Resolution: Vessel now has an installed magnetic compass. No further action required.
Navigation
Issued 6 January 1998
Resolved
CG LIGHT LIST AND NOTICE TO MARINERS WERE NOT ON THE VESSEL.
Condition: Unknown
Due 20 January 1998
Resolved 9 December 2002
Resolution: Current CG Light list onboard vessel. No further action required.