Inspection history · 22
4 November 2025
COI Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8253210
5 December 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8043531
28 August 2024
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7995242
27 February 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7871142
18 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7794524
6 September 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7524951
27 September 2021
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7321349
22 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7292078
5 November 2020
Deficiency Check · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7076190
9 October 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6559147
2 May 2017
Administration · Industry Initiated Exam · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6160246
17 April 2014
Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4840447
26 April 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4003292
15 June 2009
Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3501391
22 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3244188
19 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3242715
9 December 2002
Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1719610
14 November 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 295547
4 March 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 415501
10 December 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 768858
9 October 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 205413
9 October 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 410085
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 November 2025
Resolved
Each lifebuoy on a towing vessel must be approved under approval series 160.050 or 160.150. Grab lines around body of life ring are frayed and need to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 January 2026
Resolution: They removed and replaced the starboard life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2025
Resolved
Machinery systems must be maintained to provide for safe operation. Solenoid on STBD MDE not securely mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 January 2026
Resolution: the solenoid is now secure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2025
Resolved
Machinery systems must be maintained to provide for safe operation. Flexible fuel line on STBD MDE making contact with governor linkage arm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 January 2026
Resolution: the hoses has been re-routed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2025
Resolved
Machinery and electrical systems must be maintained to provide for safe operation. PORT MDE governor linkage arm wired to arm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 January 2026
Resolution: the linkage was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 September 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Excessive movement from port aft rudder post.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2023
Resolution: Shipyard repaired and replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 September 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Port Gen audible alarm did not sound.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 19 September 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. No emergency lighting provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2023
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 18 September 2023
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. No list posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 September 2022
Resolved
Port MDE flywheel and pully cover was loose from a missing bolt. Make repairs to satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2022
Resolved 13 September 2022
Resolution: Replaced bolt.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 6 September 2022
Resolved
Vessels clean bilge water shaft packing drain box showed signs of a small sheen. Clean pump out catches to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2022
Resolved 13 September 2022
Resolution: Bilges were cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2022
Resolved
Vessel changed location of a portable fire extinguisher and left the old bracket empty on the upper deck port side of the engine room. Remove empty bracket or replace fire extinguisher.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2022
Resolved 13 September 2022
Resolution: Bracket was removed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2021
Resolved
No evidence that the FDS was tested annually. Provide evidence that the FDS was tested in the past 12 months.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 7 October 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 September 2021
Resolved
First aid kit found on the 2nd deck had expired items within. Removed expired items and have at least 1 full first aid kit onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 7 October 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2021
Resolved
Monthly inspections were not being conducted on the portable and semi portable fire extinguishers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 7 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 September 2021
Resolved
Missing flares onboard
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 7 October 2021
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 22 September 2021
Resolved
Radios on bridge did not operate on battery backup. Charge or replace battery so they function on battery backup.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 7 October 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 September 2021
Resolved
There was flame screen missing on the ventilation pipe for the bow fuel tank. Add screen as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 7 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 22 September 2021
Resolved
The port generator exhaust was leaking into the engine room space. Repair exhaust to prevent leakage into engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2021
Resolved 7 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 5 November 2020
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire ropes, chains, and bulwarks that provide strength and support equivalent to fixed rails. Approximately 6 feet of hand rail was missing form the vessels port side midship. Install new hand rail to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2020
Resolved 23 November 2020
Resolution: Replaced missing rails.
Documentation
Issued 4 March 1998
Resolved
33 C.F.R. 164.72 Pilot did not have radio license on his person.
Condition: Unknown
Due 4 April 1998
Resolved 1 May 1998
Documentation
Issued 4 March 1998
Resolved
33 C.F.R. 164.78 Vessel did not have the document: Record of Test and Inspection
Condition: Unknown
Due 4 May 1998
Resolved 1 May 1998
Engineering
Issued 4 March 1998
Resolved
COTP - FUEL TANK VENTS ARE IN NEED OF FLAME SCREENS.
Condition: Unknown
Due 4 May 1998
Resolved 1 May 1998
Engineering
Issued 4 March 1998
Resolved
COTP - MACHINERY GUARDS ARE NEEDED FOR SHAFTS OF MAIN ENGINE.
Condition: Unknown
Due 4 May 1998
Resolved 1 May 1998
Engineering
Issued 4 March 1998
Resolved
COTP - INSULATION IS NEEDED FOR EXHAUST LINES FOR MAIN ENGINES.
Condition: Unknown
Due 4 April 1998
Resolved 14 November 2001
Resolution: All exhaust insulated.
Engineering
Issued 4 March 1998
Resolved
COTP - COUPLING GUARDS ARE NEEDED FOR BOTH HYDROLIC PUMPS FOR STEERING.
Condition: Unknown
Due 4 May 1998
Resolved 1 May 1998
Electrical
Issued 4 March 1998
Resolved
COTP - BATTERIES NEED TO BE ENCLOSED.
Condition: Unknown
Due 4 April 1998
Resolved 1 May 1998
Engineering
Issued 4 March 1998
Resolved
COTP - INSULATION IS NEEDED FOR THE ELECTRICAL GENERATOR'S EXHAUST LINES.
Condition: Unknown
Due 4 April 1998
Resolved 1 May 1998
Navigation
Issued 4 March 1998
Resolved
COTP - STEERING PUMPS ARE LEAKING ABOUT THE PUMP HOUSING.
Condition: Unknown
Due 4 April 1998
Resolved 1 May 1998
Electrical
Issued 9 October 1997
Resolved
Vessels engine room is missing light and electrical box covers.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Construction/Loadline
Issued 9 October 1997
Resolved
The vessel had excess oil in the bilges.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Navigation
Issued 9 October 1997
Resolved
Vessels navigation lights were broken and had improper bulbs.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Navigation
Issued 9 October 1997
Resolved
Vessel did not have a bell.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Engineering
Issued 9 October 1997
Resolved
Vessel had no mesh covers on flame screens.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Navigation
Issued 9 October 1997
Resolved
Vessels steering ram motor leaking fluid.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Accommodation/Occupational Safety
Issued 9 October 1997
Resolved
Vessel had no marpol placard.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Fire Fighting
Issued 9 October 1997
Resolved
Vessel was missing a fire extinguisher in the pilot house.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Engineering
Issued 9 October 1997
Resolved
Vessel did not have an oil discharge placard.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Unknown
Issued 9 October 1997
Resolved
Vessel did not have the name and hailing port displayed on the stern of thevessel.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Documentation
Issued 9 October 1997
Resolved
Vessel did not have an FCC license.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Lifesaving
Issued 9 October 1997
Resolved
Vessel did not have any life jackets.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Navigation
Issued 9 October 1997
Resolved
Vessel did not have any charts onboard.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Navigation
Issued 9 October 1997
Resolved
Vessel did not have a magnetic compass or swing meter.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997
Unknown
Issued 9 October 1997
Resolved
Vessels operator unaware of marine casualty reporting requirements.
Condition: Unknown
Due 12 December 1997
Resolved 17 November 1997
Construction/Loadline
Issued 9 October 1997
Resolved
Vessel had excessive oil on decks.
Condition: Unknown
Due 12 December 1997
Resolved 15 December 1997