Records from 2007 to 2026. Most recent: inspection, 18 March 2026.
Documentation record
Registered dimensions (L × B × D)300.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,632 / net 1,632
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1632 - Simplified, Gross Ton
1632 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
18 March 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8328174
25 December 2025
Administrative Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8287252
1 December 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7834690
7 October 2022
MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7563630
9 December 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7365201
13 August 2020
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7031872
1 April 2020
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6935947
19 November 2019
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6858621
1 March 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6641616
25 February 2019
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6633269
19 December 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6596012
5 September 2017
Cargo Tank Internal · MTSA Verification · Internal Structural Exam · Examination of Repairs · Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6259635
6 December 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6051317
23 December 2015
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5786279
19 December 2015
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5785411
19 December 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5040424
27 December 2013
MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4779489
15 July 2013
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4653977
12 July 2013
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4653993
12 July 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4655416
16 October 2012
COI Inspection · Internal Structural Exam · Examination of Repairs · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4462646
1 March 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4254686
21 September 2011
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4151040
24 August 2010
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3825581
6 May 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3733170
17 September 2009
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3596636
15 October 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3345396
22 July 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3275991
18 May 2008
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3211268
27 August 2007
Cargo Tank Internal · MTSA Verification · COI Inspection · Internal Structural Exam · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3048300
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 February 2019
Resolved
Scantlings, material, and workmanship shall be at least equivalent to the requirements of ABS or other recognized classification society. Permanently repair 11' X 5' hull plating inset and all associated frame damage on starboard side #5 wing void tank. 46 CFR 32.60-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2019
Resolved 1 March 2019
Resolution: Recieved ABS survey report, ABS attended vessel, conducted satisfactory test of repairs. Provided report. 835 cleared.
Construction/Loadline › Hull › Hull Plating
Issued 12 July 2013
Resolved
Barge sustained damage to stern box resulting in the stern box being nearly full of water, leaving only about 1 foot of clearance in top of stern box. Issued 835 to barge informing them to fully discharge and then proceed to shipyard in COTP zone to affect repairs to the satisfaction of attending Marine Inspector.
Condition: Damaged By Earlier Event
Due 12 August 2013
Resolved 15 July 2013
Resolution: Attended barge and conducted visual inspection and witnessed testing using air/soap method of 18"x36" crop and renew on stern box. Inspected satisfactorily.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 August 2008
Resolved
Vessel resubmission is overdue. The TVRP must be amended to verify intended areas of operation/COTP zones, and identify contact information for border states before approval is granted.
Due 13 September 2008
Resolved 3 February 2009
Resolution: Vessel resubmission approved 2/3/09 with revisions received 1/28/2009. New vessel VRP expiration date 2/28/2014.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 27 August 2007
Resolved
This was a new construction project, VSL was issued 835 for not yet having their VRP fully approved. Approval letter should be issued by OCT3 2007. VSL is not to conduct cargo operations until approval letter is witnessed by Marine Inspector.
Condition: Unknown
Due 14 October 2007
Resolved 16 October 2007
Resolution: Vessel received approval letter for VRP from MSC.
Electrical › Electric Supply System (service) › Cable
Issued 27 August 2007
Resolved
The Electronic Ignition wiring Harness on the Cargo pump engine does not meet Class 1 Div 1 rating making it a explosion Hazard. Their is extension in place for this issue until 1AUG 08.
Condition: Unknown
Due 1 August 2008
Resolved 17 September 2009