Records from 2008 to 2024. Most recent: inspection, 8 October 2024.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
8 October 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8016679
5 October 2023
Administrative Inspection · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7803944
19 November 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7096104
5 December 2019
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6866730
11 November 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6867380
21 June 2019
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6727466
3 August 2018
COI Inspection · Damage Survey · MTSA Verification · Examination of Repairs · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6499764
29 November 2017
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6314229
1 December 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6050866
9 November 2015
Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5758925
4 March 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5078038
14 July 2014
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4922367
21 November 2013
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4754545
9 October 2013
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4732904
9 October 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4733217
30 August 2013
MTSA Verification · Cargo Tank Internal · COI Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4640917
4 September 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4431865
20 September 2011
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4150141
16 April 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3718167
5 August 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3551408
12 May 2008
Initial Construction-Excluding Oversight · Initial Certification · Cargo Tank Internal · Internal Structural Exam · Hull Examination · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3206396
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2020
Resolved
Each outlet and junction box must be suitable for the environment in which it is installed and be constructed to the appropriate NEMA or IEC standard. Alarm junction box is holed in two places and is no longer suitable for the environment in which it is installed. Replace junction box IAW original design.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 20 November 2020
Resolution: Alarm junction box was replaced in accordance with original design and a satisfactory test of alarm system was conducted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2020
Resolved
Each marine shipboard cable must meet all the requirements for construction and identification of either IEEE 1309, IEC 60092-353. or NPFC MIL-C-24640A or NPFC MIL-C-24643A, including the respective flammability tests contained therein. Armored cable entering alarm junction box is missing sheathing and insulation with exposed conductors visible. Replace IAW original vessel design and conduct a satisfactory test of alarm system following repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 20 November 2020
Resolution: Replaced IAW original vessel design and a satisfactory test of alarm system was conducted following repairs.
Deck/Cargo › Cargo Stowage › General
Issued 9 November 2015
Resolved
Overfill protection device required by 33 CFR 155.480 on segregated cargo tank (for waste products and not serviced by vessel's VCS) was inoperable, stem failed to rise and was stuck in cylinder. Segregated tank prohibited from use until operation of overfill device restored.
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 12 November 2015
Resolution: Vessel operator provided satisfactory evidence of new equipment installation.
Construction/Loadline › Hull › Side Shell
Issued 9 October 2013
Resolved
Effect permanent repairs of the starboard bow corner to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 10 December 2013
Resolved 21 November 2013
Resolution: Observed permanent repairs and air test of starboard bow corner.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 12 May 2008
Resolved
Vessel owner shall prove that cargo pump engine units are in complete compliance with 46 CFR 111.105-31(l).
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 10 September 2013
Resolution: Wire harness has been replaced with intrinsically safe wire harness, thus meeting 46 CFR 111.105-31(I).