FMT 3234 is a 2008 tank barge. The Coast Guard has recorded 21 inspections since 2008, most recently in October 2024, along with 5 deficiencies and 2 casualty investigations in 2019.

Records from 2008 to 2024. Most recent: inspection, 8 October 2024.

Built
2008
Last inspected
8 October 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

936063
Flag
UNITED STATES
—
Maury page id
psix-936063

Inspections, by type

…with no type recorded3
Years with a record 15 calendar years (2008–2024)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 6

Inspection history · 21

8 October 2024 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8016679
5 October 2023 Administrative Inspection · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7803944
19 November 2020 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7096104
5 December 2019 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6866730
11 November 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6867380
21 June 2019 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6727466
3 August 2018 COI Inspection · Damage Survey · MTSA Verification · Examination of Repairs · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6499764
29 November 2017 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6314229
1 December 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6050866
9 November 2015 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5758925
4 March 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5078038
14 July 2014 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4922367
21 November 2013 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4754545
9 October 2013 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4732904
9 October 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4733217
30 August 2013 MTSA Verification · Cargo Tank Internal · COI Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4640917
4 September 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4431865
20 September 2011 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4150141
16 April 2010 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3718167
5 August 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3551408
12 May 2008 Initial Construction-Excluding Oversight · Initial Certification · Cargo Tank Internal · Internal Structural Exam · Hull Examination · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3206396

Deficiency record · 5

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2020 Resolved
Each outlet and junction box must be suitable for the environment in which it is installed and be constructed to the appropriate NEMA or IEC standard. Alarm junction box is holed in two places and is no longer suitable for the environment in which it is installed. Replace junction box IAW original design.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 20 November 2020
Resolution: Alarm junction box was replaced in accordance with original design and a satisfactory test of alarm system was conducted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2020 Resolved
Each marine shipboard cable must meet all the requirements for construction and identification of either IEEE 1309, IEC 60092-353. or NPFC MIL-C-24640A or NPFC MIL-C-24643A, including the respective flammability tests contained therein. Armored cable entering alarm junction box is missing sheathing and insulation with exposed conductors visible. Replace IAW original vessel design and conduct a satisfactory test of alarm system following repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 20 November 2020
Resolution: Replaced IAW original vessel design and a satisfactory test of alarm system was conducted following repairs.
Deck/Cargo › Cargo Stowage › General
Issued 9 November 2015 Resolved
Overfill protection device required by 33 CFR 155.480 on segregated cargo tank (for waste products and not serviced by vessel's VCS) was inoperable, stem failed to rise and was stuck in cylinder. Segregated tank prohibited from use until operation of overfill device restored.
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 12 November 2015
Resolution: Vessel operator provided satisfactory evidence of new equipment installation.
Construction/Loadline › Hull › Side Shell
Issued 9 October 2013 Resolved
Effect permanent repairs of the starboard bow corner to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 10 December 2013
Resolved 21 November 2013
Resolution: Observed permanent repairs and air test of starboard bow corner.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 12 May 2008 Resolved
Vessel owner shall prove that cargo pump engine units are in complete compliance with 46 CFR 111.105-31(l).
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 10 September 2013
Resolution: Wire harness has been replaced with intrinsically safe wire harness, thus meeting 46 CFR 111.105-31(I).

Casualty record · 2

21 June 2019Routine · role: Involved in a Marine Casualty · activity 6727466
11 November 2019Routine · role: Involved in a Marine Casualty · activity 6867380
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.