Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
25 November 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8039676
6 September 2023
COI Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7786269
30 October 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7087192
15 November 2019
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6862293
26 July 2018
COI Inspection · Cargo Tank Internal · MTSA Verification · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6491590
19 September 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6270805
5 October 2016
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6016474
15 January 2016
Deficiency Check · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798410
26 December 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5788280
26 December 2015
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5788352
6 November 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5758799
12 August 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5211790
26 September 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4991304
16 July 2013
Cargo Tank Internal · MTSA Verification · Examination of Repairs · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4640891
22 August 2012
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4416633
22 January 2012
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4230476
22 January 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4232995
22 September 2011
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4151660
20 September 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4150146
14 September 2010
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3799920
15 March 2010
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3696011
12 March 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3701266
5 August 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3551409
28 May 2008
Hull Examination · MTSA Verification · Initial Construction-Excluding Oversight · Initial Certification · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3247683
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 19 September 2017
Resolved
Renew cargo pump prime mover air filter housing prior to off load of cargo per 46 CFR 32.25-5
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2017
Resolution: item renewed
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 5 October 2016
Resolved
Vessel's P/V valve is not properly seating/sealing. Replace or prove propper operation prior to conducting cargo operations
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2016
Resolution: P/V valve was repaired and new vapor tightness cert provided.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 5 October 2016
Resolved
Provide proof of a valid COFR prior to conducting cargo operations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2016
Resolution: Owner provided proof of a valid COFR.
Construction/Loadline › Hull › Side Shell
Issued 26 December 2015
Resolved
The vessel is to proceed, empty, directly to FMT Shipyard in New Orleans, LA for gas freeing and permanent repairs to the Port Stern. The repairs are to be made to the satisfaction of the Attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2016
Resolved 19 January 2016
Resolution: Satisfactory repairs made to stbd stern quarter. Void space air tested to 2.0 psi. All welds and air test sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 20 September 2011
Resolved
Vessel unable to start prime mover. Unable to demonstrate proper operation of emergency shutdown. Must demonstrate proper operation of emergency shutdown prior to use of prime mover for cargo operations.
Due 20 October 2011
Resolved 22 September 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 May 2008
Resolved
Vessel owner shall prove that cargo pump engine units are in complete compliance with 46 CFR 111.105-31(l).
Action required: 705 - Other - as specified
Due 1 August 2008
Resolved 19 January 2016
Resolution: Cargo pump engine unit is in compliance with 46 CFR 111.105.31(l). Cargo Pump Inspected and operated satisfactorily.