MAURY USCG vessel records
← All vessels

SILVER CINDY

SILVER CINDY is a 2014 tank ship. The Coast Guard has recorded 23 inspections since 2017, most recently in June 2026, along with 3 deficiencies and 2 operational controls.

Records from 2017 to 2026. Most recent: inspection, 5 June 2026.

Built
2014
Last inspected
5 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9682368
1309421
Flag
MARSHALL ISLANDS
Maury page id
psix-1309421

Documentation record

Tonnage as PSIX records it49738 - Dead Weight, Metric Ton
29460 - Convention (Subpart B), Gross Ton
13632 - Convention (Subpart B), Net Ton
60300 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 23

5 June 2026 Administrative Inspection · COC-CHEM & TVE Annual
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8392629
5 April 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8343000
23 June 2025 COC-CHEM Renew · PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8161936
14 January 2025 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8063303
25 August 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7986058
11 June 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7713048
6 June 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704228
4 March 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7146812
10 March 2020 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6923853
9 March 2020 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6923123
6 March 2020 COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6922032
11 February 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6906724
10 February 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6910732
21 March 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6646727
16 March 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6643691
24 February 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6631402
22 February 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6621608
24 January 2018 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6340774
13 October 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6287091
29 July 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6224271
14 July 2017 MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6208884
14 June 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6175807
17 January 2017 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6033159

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 23 June 2025 Resolved
On all ships, within the machinery spaces, emergency escape breathing devices shall be situated ready for use at easily visible places, which can be reached quickly and easily at any time in the event of a fire. All engine room EEBDs exceed the 10-year shelf life as specified by the manufacturer. 74SOLAS(20)II-2/13.4.3.1 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 6 August 2025
Resolution: Objective evidence provided by vessel master.
Operations/Management › Pollution › Control of NOx
Issued 14 July 2017 Resolved
While ships are operating within an ECA, the sulphur content of fuel oil used on board ships shall not exceed the following limits: 0.10% on or after 1 January 2015. Attending PSCO confirmed that the vessel operated within the ECA with fuel exceeding 0.10% sulphur between July 10, 2017 and July 11, 2017. MARPOL VI/14.4 (10c)
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 14 July 2017
Resolution: Vessel provided PSCOs with a bunker receipt(showing that compliant MGO with a sulphur content of 0.0923 was delivered) and logs of the fuel changeover.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 June 2017 Resolved
SOLAS 14 / MARPOL ANNEX I/14.2 Any ship of 10,000 gross tonnage and above shall be with oil filtering equipment complying with paragraph 7 of this regulation. Oily water separating equipment is inoperative due to oil content meter unit failure.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2017
Resolved 15 June 2017
Resolution: CLASS REPORT CLEARED OWS DEFICIENCY

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.