DOUBLE SKIN 550

DOUBLE SKIN 550 is a 2012 tank barge. The Coast Guard has recorded 44 inspections since 2011, most recently in June 2026, along with 28 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 2011 to 2026. Most recent: inspection, 3 June 2026.

Built
2012
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

1148072
Flag
UNITED STATES
Maury page id
psix-1148072

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspections, by type

…with no type recorded8
Years with a record 16 calendar years (2011–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)304.4 ft × 70.0 ft × 28.0 ft
Registered tonnagegross 4,361 / net 4,361
ITC dimensions (L × B × D)304.4 ft × 70.0 ft × 28.0 ft
ITC tonnagegross 4,814 / net 2,771
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4900 - Dead Weight, Ton
4361 - Regulatory (Subpart C or D), Gross Ton
4814 - Convention (Subpart B), Gross Ton
4361 - Regulatory (Subpart C or D), Net Ton
2771 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 6

Inspection history · 44

3 June 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8390358
18 February 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8312338
23 October 2025 In-Service Inspection · VRP Review
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8257573
27 May 2025 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8131845
25 February 2025 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8083570
6 May 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7905180
9 February 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7863120
25 June 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7723274
11 June 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7713048
27 April 2023 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676884
28 February 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7645073
12 October 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7575698
24 May 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7458088
13 May 2022 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7447796
9 February 2022 Cargo Tank Internal · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7393559
25 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7235953
22 January 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7129076
2 December 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105124
7 August 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105136
5 February 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6903083
29 November 2019 Examination of Repairs · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6864599
10 September 2019 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6808099
26 March 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6649891
23 March 2019 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6647648
19 October 2018 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6564221
19 December 2017 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6326395
24 August 2017 MARPOL Annex VI Survey · MARPOL Annex II Examination · MTSA Verification · COI Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6247672
10 August 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6235545
1 September 2016 MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5989239
16 May 2016 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5878771
2 December 2015 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5774586
24 November 2015 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5769750
27 October 2015 MARPOL Annex II Examination · Periodic Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5752151
12 August 2015 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5213643
14 July 2015 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5183842
8 April 2015 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5098855
28 January 2015 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5060728
30 October 2014 MARPOL Annex II Examination · MARPOL Annex VI Survey · MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5014395
28 August 2014 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4967536
22 July 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4946074
31 October 2013 Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex II Examination · MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4744029
25 August 2012 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4434702
24 August 2012 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4421051
7 July 2011 Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4152642

Deficiency record · 28

01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 7 November 2025 Resolved
If the Coast Guard determines that the plan meets the requirements of this section, the Coast Guard will issue an approval letter. The approval period for a plan expires 5 years after the approval date. 33 CFR 151.27 (a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2025
Resolution: Recieved email confirmation of submitted plan and verified SOPEP/SMPEP onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 November 2025 Resolved
The vessel owner or operator...must resubmit the entire plan to the Coast Guard for approval...whenever there is a change in the vessel owner or operator. 33 CFR 155.1070(b)(2)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2025
Resolution: Issued VRP Waiver
01 - Certificates & Documentation › 011 - Ships Certificates › Pollution Prevention by Noxious Liquid Sub in Bulk
Issued 6 May 2024 Resolved
Unless waived under § 153.491, to have a Certificate of Inspection or Certificate of Compliance endorsed to carry NLS cargo, a ship must have — A Procedures and Arrangements Manual meeting paragraph (b) of this section and approved. Vessel did not have a Procedures and Arrangements Manual onboard to conduct ANNEX II cargo listed on their Cargo Authority Attachment. Provide a copy of your Procedures and Arrangement Manual to the local OCMI prior to conducting ANNEX II cargo listed in the vessels CAA.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2024
Resolution: Vsl rep submitted copy of their P&A manual, cleared 01 deficiency
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 6 May 2024 Resolved
At each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. During cargo pump shutdown testing, the attending marine inspectors observed smoke coming out of the air intake system. Rectify STBD side cargo pump prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: Resolved, operator provided video evidence of satisfactory electric shutdown of stbd pump engine.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 6 May 2024 Resolved
Manned tank barges and tankships authorized to carry Grade A, B, C, or D liquids at any temperature, shall be provided with a combustible gas indicator suitable for determining the presence of explosive concentrations of the cargo carried. Observed portable gas detector, test gas, expired since February 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2024
Resolution: Vessel operator provided photographs of purchased portable test gas bottle.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 27 April 2023 Resolved
Each oil tanker of 150 gross tons and above shall maintain an Oil Record Book Part I (Machinery Space Operations). Vessel's Oil Record Book Part I was found with entries not in chronological order, missing pages that had been ripped out, the end date already input, and all entries prior to 03Jan2023 were missing (vessel reentred service under Rose Cay in May, 2023) This deficiency is for documenting purposes only; a Letter of Warning will subsequently be issued as an enforcement action. 33 CFR 151.25
Action required: 10 - Deficiency Rectified
Due 27 April 2023
Resolved 27 April 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 29 November 2019 Resolved
The vessel's Load Line Certificate is not endorsed to show the completion of an annual survey within the required time-frame. Vessel is restricted to a Lakes, Bays, Sounds route and shall not pass the Boundary Line until a valid Load Line Certificate is provided to and approved by the US Coast Guard.
Action required: 705 - Other - as specified
Resolved 13 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2019 Resolved
110V panel ground detection panel indicates a ground. 46 CFR 111.05-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2019
Resolved 25 November 2019
Resolution: Documentation was provided showing electrical work completed by certified electrician
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2019 Resolved
Mast can be lowered in to the haz zone. Mast head-light does not meet Class 1 Div1 standards. 46 CFR 110.105-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 25 November 2019
Resolution: Photos were provided that included instructions to secure power prior to lowering mast when entering the hazardous zone as a temporary solution. Permanent repair to be made at Drydock
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2019 Resolved
Vsl must have on board the number of lifebuoys directed in 46 CFR 199.271 and 46 CFR 199.70 Vsl did not meet the min requirement (03) 46 CFR 199.271
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 12 December 2019
Resolution: [name withheld] sent documentation on procuring and installing the new lifebuouys.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 23 March 2019 Resolved
A BARGE MUST HAVE ANCHORS IN ACCORDANCE WITH THIS PART. THE BARGE LOST AN ANCHOR WHILE IN THE VICINITY OF PERTH AMBOY ANCHORAGE. THE ANCHOR IS TO BE REPLACED PRIOR TO MOVEMENT FROM THE BERTH AT KMI STATEN ISLAND. 46CFR32.15-15
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 March 2019
Resolution: Vessel installed a new anchor and three shots of chain. ABS attended, verified installation, and satisfactorily tested the equipment. Clas report in documents.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 19 October 2018 Resolved
Electric installations on a vessels must ensure protection of passengers, crew, other persons, and vessel electrical hazards. 120 V electrical panel in machinery space had a ground caused by a steering light in the NL-100 panel on the accommodation space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2018
Resolved 20 November 2018
Resolution: 120v Ground cleared.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 19 December 2017 Resolved
Each emergency outfit shall be equipped with an SCBA. SCBAs are past due for hydrostatic test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 5 January 2018
Resolution: Received documentation indicating bottles on board had been replaced with fleet spares.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 24 August 2017 Resolved
The two bellows on the cargo pumps are not vapor tight.
Condition: Improper/Lack of Maintenance
Due 1 September 2017
Resolved 25 August 2017
Engineering › Fuel Oil Service System › Piping
Issued 24 August 2017 Resolved
Fix fuel oil injector leak on forward generator.
Condition: Improper/Lack of Maintenance
Due 1 September 2017
Resolved 24 August 2017
Resolution: Corrected on spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 August 2017 Resolved
Two float lights on the ring buoys had expired batteries.
Condition: Improper/Lack of Maintenance
Due 1 September 2017
Resolved 25 August 2017
Electrical › Electric Generation Source (service) › Generator
Issued 24 August 2017 Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor. Vessel must provide a means to test the overspeed on the generators.
Due 8 September 2017
Resolved 25 August 2017
Resolution: Tests conducted
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 2 December 2015 Resolved
Horn for High Level alarm is not working. Repair or provide new.
Action required: 705 - Other - as specified
Due 7 December 2015
Resolved 9 December 2015
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 27 October 2015 Resolved
All living spaces must have not less than two avenues of escape. The emergency escape in the crews accommodation was stuck shut and could not be opened from within the space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2015
Resolved 28 October 2015
Resolution: Item was corrected on spot by loosening escape from outside. Informed crew of importance of escape being able to quickly open it from the inside.
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 27 October 2015 Resolved
Each propulsion, power, lighting, or distribution system having a neutral bus or conductor must have the neutral grounded. If the voltage of a distribution system is less than 1000 volts, line to line, a tank vessel must not have a grounded distribution system. The dryer contains a floating neutral and therefore needs to be isolated via an individual transformer to meet the requirements.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 2 December 2015
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 27 October 2015 Resolved
Fixed pressure sensing device must be installed as close as practicable to the vessel vapor connection. Replace broken pressure gage on the aft/stbd side vapor line and verify calibration of all vapor line pressure gages.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 2 December 2015
Resolution: all new gauges were installed thruout barge
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 October 2015 Resolved
The EPIRB must be stowed in a float-free bracket. The float-free hydrostatic release is expired. Replace with valid unit.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 2 December 2015
Resolution: Hydro release now good thru Nov 2017
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 27 October 2015 Resolved
All machinery must be available and ready for testing at each periodic inspection. The genarator's low lube oil and overspeed shutdowns could not be tested at the time of inspection. USCG to witness completion of generator shutdowns.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 2 December 2015
Resolution: Tested generator shutdowns, low lube, high temp, and overspeed.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 27 October 2015 Resolved
Each tank barge must be equipped with a high level, overfill, and loss of power alarm. Alarms could not be tested at time of inspection due to cargo operations. USCG to witness test of all alarms.
Condition: Invalid
Due 30 November 2015
Resolved 2 December 2015
Resolution: Tested satisfactory
Engineering › Pressure Vessel › Relief Valve
Issued 27 October 2015 Resolved
All pressure vessels must be available and ready for testing at each periodic inspection. The air receiver could not be internally inspected and the relief valve was not tested at the time of inspection. USCG to witness internal inspection on PV as well as test of relief valve.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 2 December 2015
Resolution: internally inspected, SRV tested
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 27 October 2015 Resolved
The cargo tank safety relief valves shall be inspected at least once in every two years. During a periodic inspection all pressure vacuum valves shall be exercised. Due to cargo operations the PV valves could not be operated. USCG to witness operation of all PV valves.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 2 December 2015
Resolution: PV's tested satisfactory
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 31 October 2013 Resolved
MAWP stenciled on cargo hoses and piping is incorrect. Vessel must re-stencil hoses and piping with correct MAWP. 33 CFR 154.500(f)(1).
Action required: 705 - Other - as specified
Due 14 November 2013
Resolved 4 November 2013
Resolution: Vessel provided photo documentation that all cargo piping and cargo hoses had been properly senciled.
Construction/Loadline › Hull › Double Hull
Issued 24 August 2012 Resolved
Tug Kristen Grace was pushing new construction barge B NO 250 (double hull) empty barge. Tug pushed up waiting to pass traffic when vessel ran aground. Issued 835 to clear after the space has been gas freed and a inspector has inspected the space to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 25 August 2012
Resolution: Vessel DD, no damage, Coating 100% intact.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.