MAURY USCG vessel records
← All vessels

DOUBLE SKIN 38

Built
2006
Last inspected
8 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 8 January 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2006–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

799522
Flag
UNITED STATES
Maury page id
psix-799522

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 16.0 ft
Registered tonnagegross 2,159 / net 2,159
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2006
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portBALTIMORE, MD
Endorsements, as the file codes themcw_un, reg_nfv
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2159 - Simplified, Gross Ton
2159 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 38 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 38

8 January 2026 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8285617
15 April 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8111398
29 March 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886690
11 June 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7713048
6 April 2023 MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7669989
26 April 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7438663
7 April 2022 MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7426300
12 April 2021 Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7173601
20 January 2021 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7119755
27 April 2020 Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6944511
4 February 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6900185
6 October 2019 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6829167
20 March 2019 MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645798
20 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395690
19 April 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394542
12 April 2017 MTSA Verification · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123217
2 February 2016 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5807201
30 March 2015 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5093393
9 March 2015 Annual Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5080591
12 August 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4952786
27 February 2014 MTSA Verification · Periodic Inspection · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4799988
16 October 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4465180
29 July 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4406994
21 March 2012 SIP Inspection/Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4270417
16 March 2012 Load Line/Change of Employment
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4265204
12 January 2010 SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3661962
28 July 2009 Damage Survey · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3535391
8 June 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3498226
30 April 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3535234
27 January 2009 Internal Structural Exam · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3400050
20 June 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3245367
8 April 2008 SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3179633
7 December 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3112818
8 May 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175993
23 January 2007 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2860026
12 July 2006 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175928
19 January 2006 Hull Examination · Internal Structural Exam · Initial Certification · Cargo Tank Internal
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2569258
6 January 2006 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2562152

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 January 2026 Resolved
... all rotating machinery capable of injuring personnel must be provided with adequate covers or guards. No fan guard present on ventilation fan in generator room. 46 CFR 58.01-20
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2026
Resolved 17 February 2026
Resolution: Vent guard installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2019 Resolved
Lifebuoys shall be fitted with a buoyant line and the lifebuoys shall be approved under series 160.150. The aft lifebuoy need to have the following repairs: new grab line, re-stenciled name and hailing port, and IMO reflective tape redone.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2019
Resolution: Notified from O/O that the lifebuoy line has been replaced, and the stenciling was redone.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 9 March 2015 Resolved
Ground was detected on the 440 volt ground detection panel. Identify the ground and restore to proper operation.
Action required: 705 - Other - as specified
Due 1 April 2015
Resolved 30 March 2015
Resolution: A ground is no longer present on the 440v ground detection panel.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 9 March 2015 Resolved
Complete ISE worklist items dated 09 MAR 2015.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 28 April 2017
Resolution: Cleared during drydock.
Engineering › Pressure Vessel › Piping
Issued 27 February 2014 Resolved
Machinery space pressure vessel must be hydrostatically tested to 1.25 times the maximum allowable working pressure and witnessed by the attending CG marine inspector NLT 28MAR2014.
Action required: 705 - Other - as specified
Due 28 March 2014
Resolved 21 March 2014
Resolution: Attended the vessel at the Vane Brothers Court street ship yard to witness a hydrostatic test of the pressure vessel located in the machinery space. Satisfactory test was conducted.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 June 2009 Resolved
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 February 2011
Resolution: Repaired to the satisfaction of attending CG marine inspector.
Construction/Loadline › Hull › Double Hull
Issued 27 January 2009 Resolved
Provide a repair proposal for areas noted during ISE by 28Feb09. See narrative for description of areas.
Action required: 705 - Other - as specified
Due 28 August 2009
Resolved 6 April 2009
Resolution: SDB has instituted a quarterly inspection of the DS 30 & 32 to determine the root cause of the cracking. At the end of a 6 month the result will be evaluated. It will be determined if immediate repair is needed or can it wait until next dry dock.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 19 January 2006 Resolved
Provide proof of cargo pump engine wiring harness and alternator meeting 46CFR111.105-31(l), NEC Class 1 Division 1 as per USCG D8(m) policy ltr 02-2005, NLT 31AUG06.
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 1 November 2009
Resolution: Reissued under activity 3624778.
Construction/Loadline › Structures › Deck Plating
Issued 19 January 2006 Resolved
Conduct NDT on welds were new towing bridal padeyes were installed on fwd deck.
Action required: 705 - Other - as specified
Due 19 February 2006
Resolved 20 January 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.