Records from 2009 to 2023. Most recent: inspection, 2 October 2023.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
2 October 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7801954
25 July 2023
Examination of Repairs · Drydock Exam · MTSA Verification · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7740547
7 April 2021
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7170430
7 April 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7171081
29 September 2020
Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7067485
19 November 2019
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6857445
11 October 2019
Deficiency Check · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6831192
26 November 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6631853
25 September 2018
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6560055
23 August 2018
COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6520407
15 November 2017
Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6303958
25 October 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6295369
28 October 2016
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6031137
26 October 2016
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6030210
3 May 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5868379
24 November 2015
Examination of Repairs · MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5772182
7 November 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5018251
19 July 2013
Deficiency Check · Cargo Tank Internal · Drydock Exam · MTSA Verification · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4655363
9 October 2012
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4459811
10 September 2012
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4435214
10 July 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4420150
13 March 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4262493
26 August 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4125028
23 June 2010
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3772534
16 February 2009
MTSA Verification · Hull Examination · Internal Structural Exam · Initial Certification · Initial Construction-Excluding Oversight · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3495767
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 November 2019
Resolved
Vessel reported to have water ingress into #4 port wing void. Fracture was discovered below rub rail on side shell. Vessel reps directed to make proper repairs to ABS standards.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2019
Resolved 19 November 2019
Resolution: Proper repairs had been made to damaged area. Air testing completed on #4 wing void to the satisfaction of attending Marine Inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 October 2019
Resolved
06199 - Cargo pump relief valve was not tested. Test cargo pump relief valve prior to discharge of cargo in the COTP zone of Lake Charles.
46CFR35.35-70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 12 October 2019
Resolution: Received report that the cargo pump relief valve was tested on 12OCT2019 by Industrial Pump Sales. See Documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2019
Resolved
99101 - Emergency procedures are not on board . Place emergency procedures on board.
33CFR155.1030(b)(9)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 15 October 2019
Resolution: Received objsective evidence that the emergency procedures were placed on board.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 30 November 2015
Resolved
Vessel found to have C1-D1 non-compliant engine installed in hazardous zone.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 3 May 2016
Resolution: Changed cargo authority for vessel to allow for carriage of Grade E cargos only.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 September 2012
Resolved
Replace all non-compatible gaskets with appropriate fiber gaskets on fuel tank hatch covers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 October 2012
Resolved 9 October 2012
Resolution: Gaskets replaced.
Deck/Cargo › Cargo Heating › General
Issued 10 September 2012
Resolved
Tighten bolted flange of thermal fluid heater piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2012
Resolved 10 September 2012
Resolution: Flange tightened, leaking stopped.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 September 2012
Resolved
Provide onboard, corrected and signed original copy of COI. Current COI onboard did not represent change in ownership.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 October 2012
Resolved 9 October 2012
Resolution: COI corrected and issued.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 September 2012
Resolved
Provide proper Vessel Response Plan approval letter for COTP Zone Ohio Valley and any other zones in which vessel plans to operate.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2012
Resolution: Received email with updated VRP letter.
Engineering › Fuel Oil Service System › Gauge
Issued 26 August 2011
Resolved
Repair fuel line leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2011
Resolved 29 August 2011
Resolution: The fuel line leak was repaired.