Inspection history · 48
28 February 2026
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8328692
23 February 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8314314
10 July 2025
Internal Structural Exam · MTSA Verification · Drydock Exam · Examination of Repairs · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8160635
19 April 2023
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7667953
28 May 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7575304
11 March 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7154515
29 May 2020
Administrative Inspection · COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6963345
20 September 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6816793
17 September 2019
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6789685
1 November 2018
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6569034
14 November 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6306407
25 October 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6295369
16 August 2017
Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6237581
2 August 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6234392
29 November 2016
Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6049962
6 October 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6018342
4 August 2015
COI Inspection · MTSA Verification · Examination of Repairs · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5200700
12 January 2015
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5052449
17 September 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4985642
15 September 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4984455
21 April 2014
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4840667
30 September 2013
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4720977
17 December 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4503487
14 December 2012
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4502324
8 December 2012
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4499802
8 December 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4501480
27 September 2012
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4451166
1 June 2012
Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4331298
1 March 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4254678
13 June 2011
MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4043390
29 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3881056
2 July 2010
MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3783229
28 January 2010
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3671671
12 January 2010
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3663361
13 July 2009
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3533374
28 April 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3467065
15 October 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3345389
18 June 2008
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3240580
24 May 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2938238
7 March 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2883978
3 February 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2866538
20 December 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2843705
27 September 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2787796
6 August 2006
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2739181
6 August 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2788024
5 May 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2642631
22 August 2005
Internal Structural Exam · Hull Examination · Cargo Tank Internal · MTSA Verification · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2441796
10 June 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2385963
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 November 2018
Resolved
Barge was authorized to carry 04 cargoes that required closed guaging, barge not equipped with closed guaging. Removed cargo authority for Ethylene glycol monoalkyl ethers, Ethylene glycol propyl ether, Ethyl methacrylate and 2-Ethyl-3 propylacrolein. Company to re-submit list of authorized cargoes to MSC for review and approval.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 26 November 2018
Resolution: Received updated CAA from CVC.
Electrical › Electric Generation Source (service) › Conductor
Issued 16 August 2017
Resolved
Revise electrical one line drawing to address the installation of a ground conductor between the barges, also show proof the 175 AMP breaker is not too large for a 99kw generator. 46 CFR 110.25-1, 46 CFR 111.05-3(d), 46 CFR 111.12-11(B), 46 CFR 111.107.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 23 January 2018
Resolution: Recieved approval from MSC Serial# E2-1800008 for electrical drawings.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 15 September 2014
Resolved
Prove proper operation of the 480v ground detection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2014
Resolved 17 September 2014
Engineering › Fuel Oil Service System › Filter
Issued 15 September 2014
Resolved
Install metallic bowl or flame impingment guard on plastic bowl of Racor filter assembly on the port cargo pump prime mover prior to off loading barge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2014
Stability › Watertight Integrity › General
Issued 15 September 2014
Resolved
renew hatch dog on the No. 7 starboard void forward hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2014
Resolved 17 September 2014
Construction/Loadline › Structures › Trunk
Issued 8 December 2012
Resolved
Monitor temp repair. Proceed to NUSTAR Texas City, to discharge cargo. Prior to loading proceed directly to Tubal Cane, Port Arthur, TX, to complete permanent repairs to leaking cargo tank top IWO #1 stbd trunk top, fwd face, 1 ft stbd corner, 1 inch above main deck.
Action required: 705 - Other - as specified
Resolved 14 December 2012
Resolution: Verified permament repair of the #1S Cargo Tank on forward end. Witnessed satisfactory air test of repair. Repair was a 18" x 3'' x 3/8" insert.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 August 2008
Resolved
Vessel resubmission is overdue. The TVRP must be amended to verify intended areas of operation/COTP zones, and identify contact information for border states before approval is granted.
Due 13 September 2008
Resolved 3 February 2009
Resolution: Vessel resubmission approved 2/3/09 with revisions received 1/28/2009. New vessel VRP expiration date 2/28/2014.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 27 September 2006
Resolved
Vessel is prohibited from operating the deck lighting system until proper documentation showing that the system meets the requirements for use in a Class I, Div. I Hazardous location.
Action required: 705 - Other - as specified
Due 26 December 2006
Resolved 20 December 2006
Resolution: Verified installation of intrinsically safe deck light switchs.